Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.605
Filtrar
1.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38722122

RESUMO

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Ecocardiografia Transesofagiana , Monitorização Intraoperatória , Criança , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Monitorização Intraoperatória/métodos
2.
J Cardiothorac Surg ; 19(1): 301, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38812010

RESUMO

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital anomaly characterized by the presence of four cusps instead of the usual three. It is estimated to occur in less than 0.05% of the population, with Type A (four equal-sized leaflets) accounting for roughly 30% of QAV subtypes. Based on limited clinical series, the usual presentation is progressive aortic valve regurgitation (AR) with symptoms occurring in the fourth to sixth decade of life. Severe aortic valve stenosis (AS) and acute AR are very uncommon. CASE PRESENTATION: We describe two cases of Type A QAV in patients who remained asymptomatic until their seventies with very uncommon presentations: one with severe AS and one with acute, severe AR and flail leaflet. In Case A, a 72-year-old patient with history of moderate AS presents to clinic with progressive exertional dyspnea. During work-up for transcatheter vs. surgical replacement pre-operative computed tomography angiogram (CTA) reveals a quadricuspid aortic valve with severe AS, and the patient undergoes surgical aortic valve replacement. Pre-discharge transthoracic echocardiography (TTE) shows good prosthetic valve function with no gradient or regurgitation. In Case B, a 76-year-old patient is intubated upon arrival to the hospital for acute desaturation, found to have wide open AR on catheterization, and transferred for emergent intervention. Intraoperative TEE reveals QAV with flail leaflet and severe AR. Repair is considered but deferred ultimately due to emergent nature. Post-operative TTE demonstrates good prosthetic valve function with no regurgitation and normal biventricular function. CONCLUSIONS: QAV can present as progressive severe AS and acute AR, with symptoms first occurring in the seventh decade of life. The optimal treatment for QAV remains uncertain. Although aortic valve repair or transcatheter option may be feasible in some patients, aortic valve replacement remains a tenable option.


Assuntos
Valva Aórtica , Humanos , Idoso , Valva Aórtica/anormalidades , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Masculino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca
3.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38722121

RESUMO

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Assuntos
Valva Aórtica , Ecocardiografia Transesofagiana , Humanos , Feminino , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia
4.
Am J Cardiol ; 221: 102-109, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636623

RESUMO

Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a nonuniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy, and outcomes of infolding during Medtronic Evolut TAVI (Minneapolis, MN, US). Between January 2018 and March 2022, all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into 2 groups; periprocedural characteristics and 30-day outcomes were compared. A total of 1,470 patients were included; 23 infolding cases (1.6%) were detected. Preprocedural imaging showed larger aortic anatomy and greater calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%, p <0.001). Short-term follow-up showed greater all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%, p <0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%, p = 0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of great native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or postdilation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Incidência , Idoso , Falha de Prótese , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia
5.
Physiol Meas ; 45(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38599228

RESUMO

Objective.Significant aortic regurgitation is a common complication following left ventricular assist device (LVAD) intervention, and existing studies have not attempted to monitor regurgitation signals and undertake preventive measures during full support. Regurgitation is an adverse event that can lead to inadequate left ventricular unloading, insufficient peripheral perfusion, and repeated episodes of heart failure. Moreover, regurgitation occurring during full support due to pump position offset cannot be directly controlled through control algorithms. Therefore, accurate estimation of regurgitation during percutaneous left ventricular assist device (PLVAD) full support is critical for clinical management and patient safety.Approach.An estimation system based on the regurgitation model is built in this paper, and the unscented Kalman filter estimator (UKF) is introduced as an estimation approach. Three offset degrees and three heart failure states are considered in the investigation. Using the mock circulatory loop experimental platform, compare the regurgitation estimated by the UKF algorithm with the actual measured regurgitation; the errors are analyzed using standard confidence intervals of ±2 SDs, and the effectiveness of the mentioned algorithms is thus assessed. The generalization ability of the proposed algorithm is verified by setting different heart failure conditions and different rotational speeds. The root mean square error and correlation coefficient between the estimated and actual values are quantified and the statistical significance of accuracy differences in estimation is illustrated using one-way analysis of variance (One-Way ANOVA), which in turn assessed the accuracy and stability of the UKF algorithm.Main results.The research findings demonstrate that the regurgitation estimation system based on the regurgitation model and UKF can relatively accurately estimate the regurgitation status of patients during PLVAD full support, but the effect of myocardial contractility on the estimation accuracy still needs to be taken into account.Significance.The proposed estimation method in this study provides essential reference information for clinical practitioners, enabling them to promptly manage potential complications arising from regurgitation. By sensitively detecting LVAD adverse events, valuable insights into the performance and reliability of the LVAD device can be obtained, offering crucial feedback and data support for device improvement and optimization.


Assuntos
Algoritmos , Insuficiência da Valva Aórtica , Coração Auxiliar , Insuficiência da Valva Aórtica/fisiopatologia , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Fatores de Tempo , Modelos Cardiovasculares
6.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577923

RESUMO

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Assuntos
Dissecção Aórtica , Insuficiência da Valva Aórtica , Valva Aórtica , Implante de Prótese Vascular , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Pessoa de Meia-Idade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Desenho de Prótese , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aortografia
7.
Khirurgiia (Mosk) ; (4): 141-145, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634595

RESUMO

Aortic root remodeling using the Florida sleeve technique was proposed as a simpler alternative to classical reconstructive interventions in patients with aortic root aneurysm without aortic insufficiency. We present a 10-year result of valve-sparing surgical treatment using the Florida sleeve technique in a patient with connective tissue dysplasia and aortic root aneurysm.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Raiz da Aorta , Insuficiência da Valva Aórtica , Doenças do Tecido Conjuntivo , Humanos , Valva Aórtica/cirurgia , Resultado do Tratamento , Insuficiência da Valva Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Tecido Conjuntivo
8.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616249

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Assuntos
Insuficiência da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Remoção de Dispositivo
10.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577931

RESUMO

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Espanha , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38608189

RESUMO

OBJECTIVES: Repair of the bicuspid aortic valve (BAV) has evolved in the past 25 years. The aim of this study was to review and analyse the long-term durability of isolated BAV repair with particular focus on commissural orientation (CO). METHODS: All patients who underwent BAV repair for severe aortic regurgitation between October 1998 and December 2022 were included. The study group consists of all patients operated after 2009, i.e. since CO modification. The control group includes patients who were operated before 2009. CO was classified as symmetric, asymmetric and very asymmetric. RESULTS: Overall, 594 adult patients (93% male; mean age 42 years) were included. At 15 years, survival was 94.8% [standard deviation (SD): 2.2]; freedom from reoperation was 86.8% (SD: 2.3). Freedom from aortic insufficiency ≥II was 70.8% (SD: 4.7) at 15 years. Modification of CO by sinus plication was performed in 200 (33.7%) instances. Using competing risks analysis, the absence of effective height measurement (P = 0.018), very asymmetric CO (P = 0.028), the presence of calcification (P < 0.001), the use of pericardial patch (P < 0.001), the use of subcommissural sutures (P < 0.001) and preoperative endocarditis (P = 0.005) were identified as independent predictors for reoperation. Follow-up was 97% complete (4228 patient-years); mean follow-up was 7 years (SD: 5). CONCLUSIONS: Isolated BAV repair leads to good survival and durability in all morphologic types if cusp repair is guided by effective height, suture annuloplasty is performed, and CO is modified using sinus plication in asymmetrical valves. Very asymmetrical valves may should be treated with a lower threshold for replacement.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Humanos , Masculino , Doença da Válvula Aórtica Bicúspide/cirurgia , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Adulto , Feminino , Insuficiência da Valva Aórtica/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Reoperação/estatística & dados numéricos , Doenças das Valvas Cardíacas/cirurgia , Adulto Jovem , Seguimentos
12.
J Am Heart Assoc ; 13(9): e032532, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38686861

RESUMO

BACKGROUND: This study was performed to determine cusp causes of aortic regurgitation in patients with tricuspid aortic valves without significant aortic dilatation and define cusp pathologies amenable to surgical repair (aortic valve repair [AVr]) versus aortic valve replacement. METHODS AND RESULTS: We retrospectively reviewed surgical reports of consecutive adults with tricuspid aortic valves undergoing surgery for clinically significant aortic regurgitation within a prospective registry from January 2005 to September 2019. Valvular mechanisms were determined by systematic in vivo intraoperative quantification methods. Of 516 patients, 287 (56%) underwent repair (AVr; mean±SD age, 59.9±12.4 years; 81% men) and 229 (44%) underwent replacement (aortic valve replacement; mean±SD age, 62.8±13.8 years [P=0.01 compared to AVr]; 67% men). A single valvular mechanism was present in 454 patients (88%), with cusp prolapse (46%), retraction (24%), and perforation (18%) being the most common. Prolapse involved the right cusp in 86% of cases and was more frequent in men (P<0.001). Two-dimensional transesophageal echocardiography accuracy for predicting mechanisms was 73% to 82% for the right cusp, 55% to 61% for the noncoronary cusp, and 0% for the left-coronary cusp. Cusp prolapse, younger age, and larger patient size were associated with successful AVr (all P<0.03), whereas retraction, perforation, older age, and concomitant mitral repair were associated with aortic valve replacement (all P<0.03). CONCLUSIONS: Right cusp prolapse is the most frequent single valvular mechanism in patients with tricuspid aortic valve aortic regurgitation, followed by cusp retraction and perforation. The accuracy of 2-dimensional transesophageal echocardiography is limited for left and noncoronary cusp mechanistic assessment. Prolapse is associated with successful AVr, whereas retraction and perforation are associated with aortic valve replacement. With systematic intraoperative quantification methods and current surgical techniques, more than half of tricuspid aortic valve aortic regurgitation cases may be successfully repaired.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Idoso , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Resultado do Tratamento , Sistema de Registros , Anuloplastia da Valva Cardíaca/métodos
13.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38565982

RESUMO

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Assuntos
Estenose da Valva Aórtica , Aprendizado Profundo , Impressão Tridimensional , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Stents , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem
14.
Am J Cardiol ; 220: 49-55, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38580038

RESUMO

On July 31, 2023, the Trifecta valve was withdrawn from the market after concerns regarding early (≤5 years) structural valve deterioration (SVD), mainly as aortic regurgitation (AR). Our aim was to determine the timing, mechanism, and impact of bioprosthetic SVD in patients who underwent redo aortic valve replacement (redo-AVR) with either redo-SAVR or valve-in-valve transcatheter aortic valve replacement (TAVR) using Trifecta versus other bioprosthetic valves. Patients who underwent redo-AVR for SVD at our institution were categorized into 2 groups based on the valve type: Trifecta versus non-Trifecta. Multivariate Cox proportional hazard model and Kaplan-Meier curves were used to compare mortality. A total of 171 patients were included; 58 (34%) had previous SAVR with a Trifecta valve and 113 (66%) with non-Trifecta valve. A total of 103 patients (60%) underwent valve-in-valve TAVR and 68 redo-SAVR (40%). The age, gender, and Society of Thoracic Surgeons score were similar between Trifecta and non-Trifecta groups. In patients with bioprosthetic valves requiring redo-AVR, Trifecta valves had an earlier onset of greater than moderate AR (4.5 vs 11.9 years, p <0.001) and earlier time to redo-AVR (5.5 vs 12 years, p <0.001). AR was more common as the mechanism of SVD in Trifecta versus non-Trifecta valves (55.2% vs 30.1%, p = 0.006). All-cause adjusted mortality from index SAVR was higher in the Trifecta than in non-Trifecta group (hazard ratio 4.1, 95% confidence interval 1.5 to 11.5, p = 0.007). In conclusion, compared with non-Trifecta valves, Trifecta valves exhibit early SVD primarily as AR and progress rapidly to significant SVD requiring redo-AVR. Mortality is significantly higher with Trifecta than in non-Trifecta valves, potentially impacting the results of SAVR versus TAVR studies.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Falha de Prótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/mortalidade , Masculino , Feminino , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Fatores de Tempo , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos
16.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38686682

RESUMO

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Ecocardiografia Transesofagiana , Cardiopatias Congênitas , Achados Incidentais , Humanos , Feminino , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Valor Preditivo dos Testes , Implante de Prótese de Valva Cardíaca , Ecocardiografia Doppler em Cores
17.
Inn Med (Heidelb) ; 65(5): 431-438, 2024 May.
Artigo em Alemão | MEDLINE | ID: mdl-38635087

RESUMO

The pathophysiology of aortic valve diseases is of predominantly degenerative nature, characterized by calcific aortic valve stenosis, which is associated with a reduction in prognosis. The prevalence of aortic valve insufficiency also increases with advancing age. Timely causal treatment is crucial in the management of aortic valve diseases. Following the indication for intervention, the heart team plays a central role in evaluating the results and making therapeutic decisions that consider the patient's preferences. In the assessment of treatment options, considerations regarding the long-term perspective are particularly crucial, especially in younger patients. The most common therapeutic approach for aortic valve diseases is the introduction of a new valve prosthesis. In the majority of cases, this is now achieved through catheter-based implantation of a bioprosthetic heart valve, known as transcatheter aortic valve implantation (TAVI). Open surgical aortic valve replacement (AVR) is favored in younger patients with low surgical risk or in the case that TAVI is not feasible. In AVR, both biological and the longest-lasting mechanical prosthesis types are used. Surgical repair techniques are primarily applied in cases of aortic valve regurgitation. Notably, TAVI, as well as surgical procedures for the treatment of aortic valve diseases, have undergone significant advancements in recent years, including expanded indications for TAVI and, on the surgical side, in particular the development of minimally invasive surgical techniques.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Próteses Valvulares Cardíacas , Valvopatia Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Estenose da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Bioprótese
18.
Echocardiography ; 41(4): e15817, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38648213

RESUMO

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital disease. The clinical characteristics of this disease remain unclear except for those in relatively young patients reported from tertiary referral hospitals. The aim of this study was to determine the clinical features of QAV in a regional population. METHODS AND RESULTS: We retrospectively investigated 25 340 consecutive patients over middle age (median age, 73 (IQR 65-80) years; range, 45-102 years) who underwent transthoracic echocardiography (TTE) at our institute during the period from April 2008 to December 2023. Eight (0.032%) of the patients (median age, 65 years; range, 47-91 years) were diagnosed with QAV. Six patients suffered from aortic regurgitation (AR), and one patient had mild aortic stenosis at the time of QAV diagnosis. Two patients who had severe AR at referral underwent aortic valve surgery. The severity of AR in the other patients was moderate or less. During a median follow-up period of 27 months (range, 1-171 months), none of the patients other than above two patients had cardiac events. One patient died from a non-cardiac cause at 94 years of age. CONCLUSIONS: Patients diagnosed with QAV after middle age, who do not exhibit severe valve insufficiency at the time of diagnosis, may not experience worse clinical outcomes. However, further research is required for a better understanding of the long-term outcomes.


Assuntos
Valva Aórtica , Ecocardiografia , Humanos , Feminino , Masculino , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Ecocardiografia/métodos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Seguimentos
19.
Cardiovasc Pathol ; 71: 107648, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38649123

RESUMO

This case report presents a 20-year-old male patient initially diagnosed with infective endocarditis, later correctly identified as Behçet's syndrome. The patient's complex clinical presentation, including chest pain, aortic dilation, severe aortic regurgitation, and aortic root abscess, posed significant diagnostic and therapeutic challenges. Despite initial misdiagnosis and treatment difficulties, the patient's condition significantly improved with appropriate immunosuppressive therapy, underscoring the potential for successful management of this complex condition. This case serves as a valuable reminder of the diagnostic challenges posed by Behçet's syndrome and the importance of considering this condition in patients presenting with symptoms suggestive of infective endocarditis.


Assuntos
Síndrome de Behçet , Erros de Diagnóstico , Imunossupressores , Humanos , Síndrome de Behçet/diagnóstico , Síndrome de Behçet/tratamento farmacológico , Masculino , Adulto Jovem , Imunossupressores/uso terapêutico , Endocardite/diagnóstico , Endocardite/terapia , Endocardite/tratamento farmacológico , Resultado do Tratamento , Diagnóstico Diferencial , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Valor Preditivo dos Testes
20.
Int J Cardiol ; 408: 132084, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38653434

RESUMO

BACKGROUND: In congenital aortic valve disease, quantifying aortic regurgitation (AR) varies by the measurement site. Our study aimed to identify the optimal site for AR assessment using 2D and 4D MR flow measurements, with a focus on vortices. METHODS: We retrospectively analysed 31 patients with congenital aortic valve disease, performing 2D and 4D MR flow measurements at the aortic valve, sinotubular junction (STJ), ascending aorta (AAo), and using midpulmonary artery measurements as a reference. We assessed percentage AR and net forward volumes, calculated linear correlations, and plotted Bland-Altman plots. Net forward flow at all aortic sites were correlated with the main pulmonary artery. Differences in AR between 2D and 4D flows were linked to vortices detected by 4D streamlines. RESULTS: The best agreement in % AR between 2D and 4D flows was at the aortic valve (mean difference 4D2D -2.9%, limits of agreement 8.7% to -14.3%; r2 = 0.7). Correlations weakened at STJ and AAo. Vortices in the ascending aorta led to AR overestimation in 2D measurements. Net forward flow at the aortic valve by 4D flow correlated closer with main pulmonary artery than did 2D flow. (Mean difference for 2D and 4D MR flow 7.5 ml and 4.2 ml, respectively). CONCLUSIONS: For congenital aortic valve disease, the most accurate AR quantification occurs at the aortic valve using 2D and 4D MR flow. Notably, vortices in the ascending aorta can result in AR overestimation with 2D MR flow.


Assuntos
Insuficiência da Valva Aórtica , Humanos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estudos Retrospectivos , Feminino , Masculino , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Valva Aórtica/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Pessoa de Meia-Idade , Adolescente , Adulto Jovem , Criança , Valvopatia Aórtica/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...