Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.968
Filtrar
1.
J Refract Surg ; 40(6): e354-e361, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848053

RESUMO

PURPOSE: To assess the predictive accuracy of new-generation online intraocular lens (IOL) power formulas in eyes with previous myopic laser refractive surgery (LRS) and to evaluate the influence of corneal asphericity on the predictive accuracy. METHODS: The authors retrospectively evaluated 52 patients (78 eyes) with a history of laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) who subsequently underwent cataract surgery. Refractive prediction errors were calculated for 12 no-history new online formulas: 8 formulas with post-LRS versions (Barrett True-K, EVO 2.0, Hoffer QST, and Pearl DGS) using keratometry and posterior/total keratometry measured by IOLMaster 700 and 4 formulas without post-LRS versions (Cooke K6 and Kane) using keratometry and total keratometry. The refractive prediction error, mean absolute error (MAE), and percentages of eyes with prediction errors of ±0.25, ±0.50, ±0.75, ±1.00, and ±1.50 diopters (D) were compared. RESULTS: The MAEs of the 12 formulas were significantly different (F = 83.66, P < .001). The MAEs ranged from 0.62 to 0.94 D and from 1.07 to 1.84 D in the formulas with and without post-LRS versions, respectively. The EVO formula produced the lowest MAE (0.60) and MedAE (0.47), followed by the Barrett True-K (0.69 and 0.50, respectively). Each percentage of eyes with refractive prediction error was also significantly different among the 12 formulas (P < .001). CONCLUSIONS: The EVO and Barrett True-K formulas demonstrate comparable performance to the other existing formulas in eyes with a history of myopic LASIK/PRK. Surgeons should use these formulas with post-LRS versions and input keratometric values whenever possible. [J Refract Surg. 2024;40(6):e354-e361.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Implante de Lente Intraocular , Lentes Intraoculares , Miopia , Óptica e Fotônica , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Feminino , Masculino , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Córnea/fisiopatologia , Reprodutibilidade dos Testes , Biometria/métodos , Facoemulsificação , Idoso
2.
J Refract Surg ; 40(6): e371-e380, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848054

RESUMO

PURPOSE: To report on the prospective evaluation of photorefractive keratectomy (PRK) in experienced ametropic naval aviators that led to the approval of refractive surgery for military pilots. METHODS: This was the first study evaluating refractive surgery in naval aviators. Return to flight status after PRK and clinical outcomes and subjective and objective flight performance were evaluated. RESULTS: A total of 785 U.S. naval aviators were enrolled in the study. Average preoperative refraction was -2.92 ± 1.73 diopters (D) (range: +5.25 to -9.13 D). By 6 months, 85.9% of eyes were within ±0.50 D and 96.4% were within ±1.00 D of emmetropia. 94.4% of eyes achieved 20/20 or better, 74.3% had 20/16 or better, and 45.2% had 20/12.5 or better uncorrected distance visual acuity (UDVA) at 6 months. A total of 78.5% of aviators met return-to-flight criteria by 4 weeks, 83.3% by 8 weeks, and 90.8% by 12 weeks following PRK. All aviators eventually returned to full flight status. Cumulative flight experience included logging more than 48,000 flight hours and 19,500 landings in the 6 months following PRK. Psychometric questionnaire results showed that 78% reported improved ability to detect other aircraft and 92% reported improved ability to land on an aircraft carrier (82% significantly improved) compared to wearing corrective lenses. No one felt their vision was worse in these dynamic environments. All aviators indicated they would undergo the procedure again and would recommend it to a fellow aviator. CONCLUSIONS: This prospective study in U.S. naval aviators determined PRK to be safe and effective in a unique patient population operating in a visually demanding and hazardous environment. The program continues to be enthusiastically supported by aviators and PRK is now allowed in all branches of the military and for National Aeronautics and Space Administration astronauts. [J Refract Surg. 2024;40(6):e371-e380.].


Assuntos
Lasers de Excimer , Militares , Miopia , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Ceratectomia Fotorrefrativa/métodos , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Adulto , Masculino , Estados Unidos , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Lasers de Excimer/uso terapêutico , Refração Ocular/fisiologia , Adulto Jovem , Pessoa de Meia-Idade , Medicina Aeroespacial , Resultado do Tratamento
3.
J Refract Surg ; 40(6): e362-e370, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38848058

RESUMO

PURPOSE: To identify potential risk factors that increase the likelihood of re-treatment following keratorefractive lenticule extraction (KLEx) for myopia and myopic astigmatism. METHODS: This was a retrospective study of patients with myopia and myopic astigmatism who underwent KLEx using the VisuMax 500 laser (Carl Zeiss Meditec) between April 2015 and December 2020. Patients were assigned to one of two groups: the control group and the re-treatment group (if they had additional refractive surgery within 2 years of the primary treatment). The effect of different preoperative, intraoperative, and postoperative parameters on the re-treatment rate was analyzed. RESULTS: Overall 1,822 eyes of 938 patients were analyzed. In total, 2.96% of eyes (n = 54) underwent re-treatment. The re-treated patients were more likely to be women and have high myopia, high astigmatism, steep corneas, higher ocular residual astigmatism, and residual myopic and/or astigmatic refractive error. In contrast, no significant correlation was found between re-treatment rate and age, chord µ, type of astigmatism, and corneal thickness. CONCLUSIONS: Factors associated with higher rates of retreatment after KLEx included female gender, manifest refractive high myopia (> -5.00 diopters [D]), astigmatism (> 2.00 D), spherical equivalent (> 6.00 D), ocular residual astigmatism, steeper corneas, and postoperative residual myopic and astigmatic refractive errors. This study may help to preoperatively detect patients at risk for re-treatment, improve preoperative patient counseling, and optimize patient selection to reduce future re-treatment rates. [J Refract Surg. 2024;40(6):e362-e370.].


Assuntos
Astigmatismo , Lasers de Excimer , Miopia , Refração Ocular , Reoperação , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Feminino , Adulto , Fatores de Risco , Miopia/cirurgia , Miopia/fisiopatologia , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Adulto Jovem , Substância Própria/cirurgia , Topografia da Córnea , Pessoa de Meia-Idade , Adolescente , Cirurgia da Córnea a Laser/métodos
4.
Am J Case Rep ; 25: e942853, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698617

RESUMO

BACKGROUND Pigmented purpuric dermatosis (PPD) is a rare disease that is poorly understood but thought to result from inflammation of the capillaries causing extravasation of erythrocytes into the soft tissue. There are a variety of potential causes, including medications, such as acetaminophen and aspirin, abnormal humoral immunity, and excessive exercise. Although benign, PPD can be bothersome to patients due to associated pruritus, weeping, and poor cosmetic results. Treatment of this lesion is difficult, with no standardized regimen and a tendency for relapse once treatment is discontinued. CASE REPORT This case reports on a 77-year-old man who presented to an outpatient dermatology clinic with bilateral lower extremity edema with associated weeping and erythema for 1 year. A biopsy was conducted and resulted as PPD. He began treatment with excimer laser therapy after conservative and topical treatment options failed, with resolution of symptoms without recurrence for approximately 1 year. CONCLUSIONS PPD is notoriously difficult to treat, and historic treatment options include topical corticosteroids, oral supplements, and immunomodulators, all of which come with a range of adverse effects. However, new literature supports the use of phototherapy to treat PPD, with varying results. Previously implemented options include but are not limited to phototherapy with psoralen plus ultraviolet A, narrow band ultraviolet B, advanced fluorescence technology pulsed light, and fractional non-ablative 1540-nm erbium: glass laser, each with varying degrees of success. This case discusses the successful treatment of recalcitrant PPD with excimer laser therapy and maintenance of remission for approximately 1 year.


Assuntos
Lasers de Excimer , Púrpura , Humanos , Masculino , Idoso , Púrpura/etiologia , Lasers de Excimer/uso terapêutico , Transtornos da Pigmentação/terapia
5.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717080

RESUMO

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Assuntos
Astigmatismo , Substância Própria , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Acuidade Visual/fisiologia , Estudos Retrospectivos , Adulto , Refração Ocular/fisiologia , Masculino , Feminino , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico , Topografia da Córnea , Seguimentos , Resultado do Tratamento , Cirurgia da Córnea a Laser/métodos
6.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717081

RESUMO

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Assuntos
Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Cirurgia Assistida por Computador , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual/fisiologia , Estudos Prospectivos , Refração Ocular/fisiologia , Adulto , Masculino , Feminino , Lasers de Excimer/uso terapêutico , Método Duplo-Cego , Miopia/cirurgia , Miopia/fisiopatologia , Adulto Jovem , Cirurgia Assistida por Computador/métodos , Pessoa de Meia-Idade , Córnea/cirurgia , Córnea/fisiopatologia , Seguimentos
7.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717083

RESUMO

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Assuntos
Aberrometria , Astigmatismo , Córnea , Substância Própria , Aberrações de Frente de Onda da Córnea , Densitometria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Feminino , Masculino , Lasers de Excimer/uso terapêutico , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
8.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717082

RESUMO

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Assuntos
Substância Própria , Topografia da Córnea , Epitélio Corneano , Hiperopia , Refração Ocular , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Estudos Prospectivos , Substância Própria/cirurgia , Substância Própria/patologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Epitélio Corneano/cirurgia , Epitélio Corneano/patologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Lasers de Excimer/uso terapêutico , Adulto Jovem , Aberrações de Frente de Onda da Córnea/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Oftalmopatias Hereditárias
9.
J Refract Surg ; 40(5): e279-e290, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717084

RESUMO

PURPOSE: To review the atypical development of Salzmann's nodular degeneration (SND) after two cases of laser in situ keratomileusis (LASIK) and one case of photorefractive keratomileusis (PRK), and to highlight the pathophysiology of SND and its treatment. METHODS: Three cases of SND (two following LASIK performed with microkeratomes and one following PRK) were reviewed and Pubmed.gov and internet searches were performed. RESULTS: SND is myofibroblast-generated fibrosis in the subepithelial space between the epithelium and Bowman's layer that develops years or decades after traumatic, surgical, infectious, or inflammatory injuries to the cornea in which the epithelial basement membrane is damaged in one or more locations and does not fully regenerate. It is hypothesized based on these cases, and the previous immunohistochemistry of other investigators, that myofibroblast precursors, such as fibrocytes or corneal fibroblasts, that enter the subepithelial space are driven to develop into myofibroblasts, which slowly proliferate and extend the fibrosis, by transforming growth factor-beta from epithelium and tears that passes through the defective epithelial basement membrane. These myofibroblasts and the disordered collagens, and other extracellular matrix components they produce, make up the subepithelial opacity characteristic of SND. Nodules are larger accumulations of myofibroblasts and disordered extracellular matrix. If the injury is associated with damage to the underlying Bowman's layer and stroma, as in LASIK flap generation, then the myofibroblasts and fibrosis can extend into Bowman's layer and the underlying anterior stroma. CONCLUSIONS: SND fibrosis often extends into Bowman's layer and the anterior stroma if there are associated Bowman's defects, such as incisions or lacerations. In the latter cases, SND frequently cannot be removed by simple scrape and peel, as typically performed for most common SND cases, but can be trimmed to remove the offending tissue. This condition is more accurately termed Salzmann's subepithelial fibrosis. [J Refract Surg. 2024;40(5):e279-e290.].


Assuntos
Epitélio Corneano , Fibrose , Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Humanos , Epitélio Corneano/patologia , Masculino , Lâmina Limitante Anterior/patologia , Adulto , Miopia/cirurgia , Miopia/fisiopatologia , Feminino , Doenças da Córnea/etiologia , Doenças da Córnea/cirurgia , Lasers de Excimer/uso terapêutico , Miofibroblastos/patologia , Pessoa de Meia-Idade
10.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717086

RESUMO

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Assuntos
Córnea , Elasticidade , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Humanos , Córnea/fisiopatologia , Córnea/cirurgia , Adulto , Feminino , Masculino , Fenômenos Biomecânicos , Lasers de Excimer/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto Jovem , Elasticidade/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Pressão Intraocular/fisiologia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
11.
Photodermatol Photoimmunol Photomed ; 40(3): e12972, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38752300

RESUMO

BACKGROUND: In previous studies, the 308-nm light-emitting diode (LED) has been proven safe and effective for treating vitiligo. However, direct comparisons between the 308-nm LED and 308-nm excimer lamp (308-nm MEL) for the treatment of vitiligo are lacking. OBJECTIVE: To compare the efficacy of the 308-nm LED and 308-nm MEL for treating nonsegmental stable vitiligo. PATIENTS AND METHODS: This randomized controlled trial was conducted between January 2018 and August 2023. Enrolled patients were randomly assigned to either the 308-nm LED or the 308-nm MEL groups, both receiving 16 treatment sessions. Adverse events that occurred during the treatment were documented. RESULTS: In total, 269 stable vitiligo patches from 174 patients completed the study. A total of 131 lesions were included in the 308-nm LED group, and 138 lesions were included in the 308-nm MEL group. After 16 treatment sessions, 38.17% of the vitiligo patches in the 308-nm LED group achieved repigmentation of at least 50% versus 38.41% in the 308-nm MEL group. The two devices exhibited similar results in terms of efficacy for a repigmentation of at least 50% (p = .968). The incidence of adverse effects with the two phototherapy devices was comparable (p = .522). CONCLUSIONS: Treatment of vitiligo with the 308-nm LED had a similar efficacy rate to the 308-nm MEL, and the incidence of adverse effects was comparable between the two devices.


Assuntos
Vitiligo , Humanos , Vitiligo/radioterapia , Vitiligo/terapia , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Adolescente , Lasers de Excimer/uso terapêutico , Lasers de Excimer/efeitos adversos , Adulto Jovem , Criança
12.
Curr Opin Ophthalmol ; 35(4): 278-283, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38700941

RESUMO

PURPOSE OF REVIEW: Laser keratorefractive surgery achieves excellent visual outcomes for refractive error correction. With femtosecond laser, small incision lenticule extraction (SMILE) is an increasingly viable alternative to laser-assisted in situ keratomileusis (LASIK). Comparative studies demonstrate similar efficacy and predictability between SMILE and LASIK, making it difficult for clinicians to choose which to use. This review thus compares femtosecond-LASIK (FS-LASK) and SMILE in various scenarios, to assist clinicians in deciding which refractive surgery procedure to recommend. RECENT FINDINGS: SMILE may be superior for highly myopic eyes due to a smaller decrease in functional optical zone. SMILE further induces less spherical aberration and less overall higher order aberrations in mesopic conditions. SMIILE also has less postoperative dry eye, making it suitable those with preexisting dry eye. For low to moderate myopic astigmatism correction, FS-LASIK has less undercorrection compared to SMILE. Lastly, SMILE has not yet received Food and Drug Administration or Conformité Européenne approval for hyperopic correction, rendering FS-LASIK the choice of procedure for hyperopic correction. SUMMARY: Both FS-LASIK and SMILE demonstrate good efficacy and predictability. Understanding specific clinical scenarios where one may be superior to the other will aid clinicians in choosing the most suitable procedure for personalized care.


Assuntos
Substância Própria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Miopia/fisiopatologia , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Microcirurgia/métodos
13.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741093

RESUMO

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Aberrações de Frente de Onda da Córnea , Miopia , Refração Ocular , Acuidade Visual , Humanos , Miopia/cirurgia , Miopia/fisiopatologia , Astigmatismo/fisiopatologia , Astigmatismo/etiologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Adulto Jovem , Refração Ocular/fisiologia , Substância Própria/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Complicações Pós-Operatórias , Topografia da Córnea , Adolescente
14.
Sci Rep ; 14(1): 11989, 2024 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796537

RESUMO

VISUMAX 800 was introduced to improve the patient experience and clinical outcomes of small incision lenticule extraction (SMILE). This was a retrospective, matched, and case-control study (1:2) controlled for preoperative central corneal thickness and refractive error that compared early refractive and visual outcomes after SMILE using VISUMAX 800 and VISUMAX 500 to treat myopia. We included 50 eyes that underwent the VISUMAX 800 SMILE and 100 eyes that underwent the VISUMAX 500 SMILE. SMILE using VISUMAX 800 was performed using the CentraLign aid for vertex centration. Cyclotorsion was controlled by an OcuLign assistant in the VISUMAX 800 group after corneal marking. Corneal higher-order aberrations (HOAs) were evaluated using a Pentacam 1 month after surgery. No differences were observed in the pre- and post-operative refractive and visual outcomes at 1 day, 1 month, and 6 months after surgery. VISUMAX 800 induced less total HOAs than VISUMAX 500 (P = 0.036). No statistically significant differences were observed in the amounts of induced spherical aberrations or vertical and horizontal comas. No differences were observed in the 1 month and 6 months refractive and visual outcomes between two SMILE procedures, except for VISUMAX 800, which resulted in lower postoperative total HOAs than VISUMAX 500.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Acuidade Visual , Humanos , Miopia/cirurgia , Feminino , Estudos Retrospectivos , Masculino , Estudos de Casos e Controles , Adulto , Resultado do Tratamento , Cirurgia da Córnea a Laser/métodos , Adulto Jovem , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico
15.
Transl Vis Sci Technol ; 13(5): 11, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38748408

RESUMO

Purpose: Computational models can help clinicians plan surgeries by accounting for factors such as mechanical imbalances or testing different surgical techniques beforehand. Different levels of modeling complexity are found in the literature, and it is still not clear what aspects should be included to obtain accurate results in finite-element (FE) corneal models. This work presents a methodology to narrow down minimal requirements of modeling features to report clinical data for a refractive intervention such as PRK. Methods: A pipeline to create FE models of a refractive surgery is presented: It tests different geometries, boundary conditions, loading, and mesh size on the optomechanical simulation output. The mechanical model for the corneal tissue accounts for the collagen fiber distribution in human corneas. Both mechanical and optical outcome are analyzed for the different models. Finally, the methodology is applied to five patient-specific models to ensure accuracy. Results: To simulate the postsurgical corneal optomechanics, our results suggest that the most precise outcome is obtained with patient-specific models with a 100 µm mesh size, sliding boundary condition at the limbus, and intraocular pressure enforced as a distributed load. Conclusions: A methodology for laser surgery simulation has been developed that is able to reproduce the optical target of the laser intervention while also analyzing the mechanical outcome. Translational Relevance: The lack of standardization in modeling refractive interventions leads to different simulation strategies, making difficult to compare them against other publications. This work establishes the standardization guidelines to be followed when performing optomechanical simulations of refractive interventions.


Assuntos
Simulação por Computador , Córnea , Análise de Elementos Finitos , Ceratectomia Fotorrefrativa , Humanos , Córnea/cirurgia , Córnea/fisiologia , Ceratectomia Fotorrefrativa/métodos , Simulação por Computador/normas , Lasers de Excimer/uso terapêutico , Modelos Biológicos
16.
J Refract Surg ; 40(4): e239-e244, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593260

RESUMO

PURPOSE: To explore changes in corneal epithelial thickness (CET) after femtosecond laser-assisted laser in situ keratomileusis in patients with high astigmatism. METHODS: CET was measured at every intersection of the concentric circles and specific axes using AngioVue optical coherence tomography (Angio-OCT) preoperatively and 1 month postoperatively. The average thickness of corneal central, paracentral, and peripheral regions was the mean of the points within the central 2, 2 to 5, and 5 to 7 mm areas, respectively. Correlation analysis was performed to investigate the association between CET along different axes and other preoperative and postoperative parameters. RESULTS: Forty-two eyes of 28 patients were included. CET along the astigmatic (K1) and perpendicular (K2) axes in the central and paracentral areas increased (P < .001), whereas that along the K2 axis decreased in the peripheral area 1 month postoperatively (P = .001). The amount of CET change in the peripheral area between the K1 and K2 axes was significantly different (P < .001). In the central area, the change in CET along the K2 axis was positively correlated with ablation depth (r = 0.315, P = .042) and negatively with refractive power after surgery (r = -0.347, P = .024). In the peripheral area, the changes in CET along both K1 and K2 axes were negatively correlated with ablation depth (r = -0.431, P = .004; r = -0.387, P = .011, respectively). CONCLUSIONS: Epithelial modeling differed between the different astigmatism axes after refractive surgery. The compensatory response of the corneal epithelium is more pronounced along the steeper axis. [J Refract Surg. 2024;40(4):e239-e244.].


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual , Astigmatismo/cirurgia , Miopia/cirurgia , Estudos Prospectivos , Lasers , Lasers de Excimer/uso terapêutico
17.
J Refract Surg ; 40(4): e245-e252, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593261

RESUMO

PURPOSE: To evaluate clinical outcomes and visual quality 12 months after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) performed with the Custom-Q algorithm for correction of myopia with or without astigmatism and compensate for age-related accommodation deficiency. METHODS: Patients who had Custom-Q FS-LASIK for myopia and myopic astigmatism with age-related accommodation deficiency were included in this retrospective study. Distance, intermediate, and near visual acuities, objective and subjective refractions, Q-factor, corneal higher order aberrations (HOAs), accommodation function, defocus curve, contrast sensitivity, and a subjective questionnaire assessing visual quality were evaluated 12 months postoperatively. RESULTS: Clinical data of 43 cases were analyzed. The mean age was 42.02 ± 1.85 years (range: 40 to 48 years). At the 12-month follow-up visit, there were 43 (100%), 42 (97%), and 33 (77%) patients who achieved a binocular uncorrected distance, intermediate, and near visual acuity, respectively, better than 20/20 separately. Defocus curves revealed better distance vision in the dominant eyes, and the nondominant eyes performed better at intermediate and near vergence (P < .001). The Q-value and corneal spherical aberration coefficient were more positive in the dominant eyes than those in the nondominant eyes (P < .001). The accommodative amplitude and relative accommodation improved binocularly (P < .001). The questionnaire demonstrated high patient satisfaction with near vision, and no one reported having severe visual disturbance. CONCLUSIONS: For myopic patients with age-related accommodation deficiency, the Custom-Q algorithm proved to be an effective way to achieve acceptable near vision without compromising distance vision. [J Refract Surg. 2024;40(4):e245-e252.].


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Adulto , Estudos Retrospectivos , Acuidade Visual , Córnea , Miopia/cirurgia , Astigmatismo/cirurgia , Lasers de Excimer/uso terapêutico , Refração Ocular , Resultado do Tratamento
18.
Sci Rep ; 14(1): 8732, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627567

RESUMO

We sought to evaluate the topographic risk factors for early myopic regression after small-incision lenticule extraction (SMILE). A retrospective case‒control study was conducted, and individuals who underwent SMILE surgery were enrolled. Among them, 406 and 14 eyes were categorized into the nonregression and regression groups, respectively. The preoperative and postoperative parameters in the two groups were collected, including spherical refraction (SE), axial length (AXL) and topographic data. A generalized linear model was adopted to analyze the difference in each parameter between the two groups. After 6 months, UCVA decreased in the regression group, and SE increased in the regression group (both P < 0.05). The increase in the CCT at the thinnest point (P = 0.044), flat corneal curvature (P = 0.012) and TCRP (P = 0.001) were significantly greater in the regression group. Regarding the risk factors for myopic regression, preoperative SE, preoperative sphere power, preoperative AXL, preoperative flat corneal curvature, preoperative SA, early postoperative SE, early postoperative sphere power, early postoperative AXL and early postoperative CCT difference were significantly greater in the regression group (all P < 0.05). The SE, sphere power, AXL, preoperative flat corneal curvature, preoperative SA, and postoperative CCT difference correlate with early myopic regression after SMILE.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Ferida Cirúrgica , Humanos , Córnea/cirurgia , Substância Própria/cirurgia , Acuidade Visual , Estudos Retrospectivos , Estudos de Casos e Controles , Cirurgia da Córnea a Laser/efeitos adversos , Lasers de Excimer/uso terapêutico , Refração Ocular , Miopia/cirurgia , Ferida Cirúrgica/cirurgia
19.
BMC Ophthalmol ; 24(1): 174, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627647

RESUMO

PURPOSE: To evaluate the long-term clinical outcomes of femtosecond thin-flap LASIK (femto-LASIK) for correction of refractive error after penetrating keratoplasty in keratoconus-affected eyes. SETTING: a private ophthalmology clinic. DESIGN: Prospective interventional case series. METHODS: This prospective interventional case series enrolled 22 eyes of 22 patients who underwent femto-LASIK for the management of post-penetrating keratoplasty ametropia. The refractive error, uncorrected (UDVA), and corrected (CDVA) distance visual acuities and vector analysis were reported in short-term and long-term period after surgery. RESULTS: The mean age was 32.7 ± 7.5 years (range, 23 to 47 years) at the surgery time. The average time between PK and femto-LASIK was 42.5 ± 31.7 months. The average follow-up duration after femto-LASIK was 81.2 ± 18.6 months. The mean preoperative UDVA significantly improved from 0.47 ± 0.15 logMAR to 0.35 ± 0.14 logMAR at 12 months (P = 0.048) and 0.4 ± 0.17 at final follow-up exam (P = 0.007). CDVA was 0.22 ± 0.1 at baseline which improved to 0.18 ± 0.15 and 0.15 ± 0.1 logMAR at 12 and 81 months, respectively. (Ps = 0.027, 0.014). The mean cylinder before surgery was - 5.04 ± 1.4D which significantly decreased to -1.5 ± 0.8 D at 12 months postoperatively. (P < 0.001). There was a significant increase in refractive astigmatism from 12 months to 81 months postoperatively (-3.1 ± 2.0, P = 0.002). At the final visit, the efficacy index was 0.83, and the safety index was 1.16. CONCLUSIONS: Despite the short-term outcome indicated that femo-LASIK was effective for correction of post-keratoplasty ametropia during short-term period, a notable regression in its effect was observed in the long-term follow-up. Therefore, the predictability of this technique might decrease in the long-term.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Erros de Refração , Humanos , Adulto , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratoplastia Penetrante/efeitos adversos , Estudos Prospectivos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
20.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600456

RESUMO

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Miopia , Humanos , Refração Ocular , Coma , Topografia da Córnea , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Astigmatismo/cirurgia , Substância Própria/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...