Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.386
Filtrar
1.
J. optom. (Internet) ; 17(3): [100497], jul.-sept2024. graf, tab
Artigo em Inglês | IBECS | ID: ibc-231871

RESUMO

Purpose: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. Methods: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. Results: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p = 0.012) and -0.11±0.12 D (YG, p = 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p = 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. Conclusion: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Idoso , Visão Ocular , Acuidade Visual , Fundo de Olho , Lentes de Contato , Testes Visuais
2.
J. optom. (Internet) ; 17(3): [100514], jul.-sept2024. tab
Artigo em Inglês | IBECS | ID: ibc-231876

RESUMO

Purpose: To analyze binocular vision of individuals aged 18 to 35 years diagnosed with keratoconus, utilizing spectacles and rigid gas-permeable (RGP) contact lenses. Research was led by the Universidad Autónoma de Aguascalientes, México and Fundación Universitaria del Área Andina Pereira, Colombia. Methods: A single center, prospective non-randomized, comparative, interventional, open-label study, in which the differences in binocular vision performance with both spectacles and RGP contact lenses was carried out from December 2018 to December 2019. Sampling was performed according to consecutive cases with keratoconus that met the inclusion criteria until the proposed sample size was reached. Results: Rigid gas-permeable (RGP) contact lenses notably enhanced distance and near visual acuity in keratoconus patients compared to spectacles. Visual alignment analysis shows exophoria at both distances and is slightly higher with RGP contact lenses. The difference was statistically significant (p<0.05), with 82.5 % presenting compensated phoria with spectacles and pnly 42.50% with RGP contact lenses. Stereoscopic vision improved while wearing RGP contact lenses (42.59 %), although accommodation and accommodative flexibility remained within normal ranges. Conclusions: Patients with keratoconus fitted with RGP contact lenses have improved binocular vision skills such as visual acuity, stereopsis, and accommodative flexibility. However, even when the vergence and motor system is decompensated with respect to normal ranges, the range between break and recovery points for both fusional reserves and the near point of convergence (NPC) improves with the use of RGP contact lenses, giving indications of an adaptive condition of the motor system from the medium to the long term.(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Ceratocone , Óculos , Lentes de Contato , Visão Binocular , Testes Visuais , Colômbia , México , Oftalmologia , Estudos Prospectivos
3.
J. optom. (Internet) ; 17(2): [100498], Abr-Jun, 2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231627

RESUMO

Objective: The high incidence of keratoconus has caused its management, etiology, and pathogenesis to be controversial topics in the ophthalmology field. This study aims to analyze the relationship between the different publications and authors through citation networks, as well as to identify the research areas and determine the most cited article. Methods: The search for publications was carried out through the Web of Science database, using the term “Keratoconus” between 1900 and December 2022. The Citation Network Explorer and CiteSpace software were used for the publication analysis. Results: 9,655 publications were found, with 124,379 citations generated on the network. The year with the highest number of publications was 2021. The most cited publication was “Keratoconus” by Rabinowitz, published in 1998. Cluster function gave five groups of research areas about keratoconus: corneal signs and parameters, cross-linking efficiency and effects, clinical factors, keratoplasty, and treatment. Conclusions: The citation network offers an objective and comprehensive analysis of the papers on keratoconus. (AU)


Assuntos
Transplante de Córnea , Ceratocone , Oftalmologia , Lentes de Contato
4.
Invest Ophthalmol Vis Sci ; 65(5): 4, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691089

RESUMO

Purpose: To investigate the adhesion of Acanthamoeba to scleral contact lens (ScCL) surface according to lens shape. Methods: Two strains of A. polyphaga (CDC:V062 and ATCC 30461) and one clinical Acanthamoeba isolate, were inoculated onto five contact lens (CL): one first-generation silicone hydrogel (SHCL; lotrafilcon B; adhesion control) containing plasma surface treatment; two ScCL (fluorosilicone acrylate) one containing surface treatment composed of plasma and the other containing plasma with Hydra-PEG, and two CL designed with a flat shape having the same material and surface treatments of the ScCL. Trophozoites that adhered to the lens's surfaces were counted by inverted optical light microscopy. Possible alterations of the lens surface that could predispose amoeba adhesion and Acanthamoeba attached to these lens surfaces were evaluated by scanning electron microscopy (SEM). Results: All strains revealed greater adhesion to the ScCL when compared with the flat lenses (P < 0.001). The clinical isolate and the ATCC 30461 had a higher adhesion (P < 0.001) when compared with the CDC:V062. A rough texture was observed on the surface of the lenses that have been examined by SEM. Also, SEM revealed that the isolates had a rounded appearance on the surface of the ScCL in contrast with an elongated appearance on the surface of the silicone hydrogel. Conclusions: The findings revealed that the curved shape of the ScCL favors amoeba adhesion.


Assuntos
Acanthamoeba , Microscopia Eletrônica de Varredura , Acanthamoeba/fisiologia , Acanthamoeba/ultraestrutura , Esclera , Humanos , Lentes de Contato Hidrofílicas/parasitologia , Adesão Celular/fisiologia , Lentes de Contato/parasitologia , Trofozoítos/ultraestrutura , Trofozoítos/fisiologia , Hidrogéis , Animais
5.
Sci Rep ; 14(1): 11727, 2024 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778161

RESUMO

The tear fluid is a readily accessible, potential source for biomarkers of disease and could be used to monitor the ocular response to contact lens (CL) wear or ophthalmic pathologies treated by therapeutic CLs. However, the tear fluid remains largely unexplored as a biomarker source for RNA-based molecular analyses. Using a rabbit model, this study sought to determine whether RNA could be collected from commercial CLs and whether the duration of CL wear would impact RNA recovery. The results were referenced to standardized strips of filtered paper (e.g., Shirmer Strips) placed in the inferior fornix. By performing total RNA isolation, precipitation, and amplification with commercial kits and RT-PCR methods, CLs were found to have no significant differences in RNA concentration and purity compared to Schirmer Strips. The study also identified genes that could be used to normalize RNA levels between tear samples. Of the potential control genes or housekeeping genes, GAPDH was the most stable. This study, which to our knowledge has never been done before, provides a methodology for the detection of RNA and gene expression changes from tear fluid that could be used to monitor or study eye diseases.


Assuntos
Lentes de Contato , RNA , Lágrimas , Lágrimas/metabolismo , Animais , Coelhos , RNA/isolamento & purificação , RNA/genética , RNA/análise
7.
Harefuah ; 163(5): 278-285, 2024 May.
Artigo em Hebraico | MEDLINE | ID: mdl-38734939

RESUMO

INTRODUCTION: The importance of myopia management lies in the desire to minimize the potential ocular risks that increase with high myopia. AIMS: To assess the decrease in myopia progression using topical low dose atropine combined with peripheral blur contact lenses (CL). METHODS: This retrospective review study included 25 children between the ages of 8.5 years to 14 years. The children all had a minimal increase in myopia of 0.75D during the year prior to treatment. The children were divided into two groups. The control group included 14 children who wore single-vision spectacles )SV) averaging 3.20±0.9D ranging from 1.5-5.3D. The study group included 11 children who wore dual-focus CL, with an average prescription of 3.4±0.7D ranging from 2.5 to 4.3D, for one year. At that point, when an additional myopia increase was observed, the children were additionally treated with topical 0.01% atropine for two years (CL+A0.01). RESULTS: There was an increase in myopia in the SV group of 1.12±0.52D, 1.08±0.56D and 0.96±0.53D in the first, second, and third years, respectively. The myopia increase in the CL+A0.01 group was 0.57±0.48D, 0.14±0.34D, and 0.17±0.29D in the first, second, and third years, respectively. CONCLUSIONS: Low-dose atropine combined with peripheral blur contact lenses was effective in decreasing myopia progression in this study. Additional, larger-scale studies are required in the future. DISCUSSION: This study found a significant decrease in myopia progression in the second and third years of treatment. The CL group showed less effectivity than the CL+A0.01 group.


Assuntos
Atropina , Lentes de Contato , Progressão da Doença , Miopia , Humanos , Atropina/administração & dosagem , Criança , Miopia/terapia , Miopia/fisiopatologia , Estudos Retrospectivos , Adolescente , Masculino , Feminino , Resultado do Tratamento , Midriáticos/administração & dosagem , Soluções Oftálmicas/administração & dosagem , Óculos
8.
Transl Vis Sci Technol ; 13(5): 12, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38758570

RESUMO

Purpose: To evaluate the visual performance in adolescents undergoing orthokeratology (OrthoK) treatment with two different optical zone diameters (OZDs). Methods: This randomized, double-masked, self-controlled prospective study was conducted at Tianjin Eye Hospital (Tianjin, China) in June 2022. Thirty-six eligible schoolchildren were enrolled and fitted with corneal refractive therapy lenses with two sizes of OZDs (5 mm [5OZ] and 6 mm [6OZ]). Each participant was randomized to wear the 5OZ in one eye and the 6OZ in the contralateral eye. Subjective visual quality was assessed using visual acuity, refraction, contrast sensitivity function, and visual symptoms, and the objective optical quality was assessed using ocular higher order aberrations (HOAs) and modulation transfer function (MTF). Results: Thirty-five myopic children completed a 1-month follow-up visit. The 5OZ lens induced significantly smaller treatment zone diameters than the 6OZ lens (P < 0.001). Subjective visual quality did not differ significantly between the two groups. Compared to baseline, aberrations of Z40, coma-like, spherical-like, and total HOAs in both groups increased significantly (P < 0.05). For the 3-mm pupils, spherical aberration in the 5OZ group was significantly higher than that in the 6OZ group (P < 0.05). The MTF value of the 6OZ group was significantly higher than that of 5OZ group for 0.3 and 1.5 cycles per degree for the 3-mm pupils (P = 0.006 and P = 0.026, respectively). However, HOAs or MTF did not differ significantly between the two groups for the 5-mm pupils. Conclusions: The difference induced by varying OZD was significant only in the smaller pupil condition. The selection of OZD in OrthoK designs in real-world patient management should be done while considering individual pupil size. Translational Relevance: This study revealed that the objective visual quality of small OZD lenses was only slightly affected for the small pupil size.


Assuntos
Miopia , Procedimentos Ortoceratológicos , Refração Ocular , Acuidade Visual , Humanos , Feminino , Procedimentos Ortoceratológicos/métodos , Masculino , Acuidade Visual/fisiologia , Estudos Prospectivos , Adolescente , Miopia/terapia , Miopia/fisiopatologia , Criança , Método Duplo-Cego , Refração Ocular/fisiologia , Sensibilidades de Contraste , Lentes de Contato
9.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742501

RESUMO

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Assuntos
Lentes de Contato , Ceratocone , Esclera , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Feminino , Masculino , Adulto , Esclera/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Topografia da Córnea , Próteses e Implantes , Adulto Jovem , Ajuste de Prótese/métodos , Adolescente , Substância Própria/cirurgia
10.
Biosens Bioelectron ; 257: 116284, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38657379

RESUMO

Smart contact lenses (SCLs) have been considered as novel wearable devices for out-of-hospital and self-monitoring applications. They are capable of non-invasively and continuously monitoring physiological signals in the eyes, including vital biophysical (e.g., intraocular of pressure, temperature, and electrophysiological signal) and biochemical signals (e.g., pH, glucose, protein, nitrite, lactic acid, and ions). Recent progress mainly focuses on the rational design of wearable SCLs for physiological signal monitoring, while also facilitating the treatment of various ocular diseases. It covers contact lens materials, fabrication technologies, and integration methods. We also highlight and discuss a critical comparison of SCLs with electrical, microfluidic, and optical signal outputs in health monitoring. Their advantages and disadvantages could help researchers to make decisions when developing SCLs with desired properties for physiological signal monitoring. These unique capabilities make SCLs promising diagnostic and therapeutic tools. Despite the extensive research in SCLs, new technologies are still in their early stages of development and there are a few challenges to be addressed before these SCLs technologies can be successfully commercialized particularly in the form of rigorous clinical trials.


Assuntos
Técnicas Biossensoriais , Lentes de Contato , Dispositivos Eletrônicos Vestíveis , Humanos , Técnicas Biossensoriais/instrumentação , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Desenho de Equipamento
11.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38578134

RESUMO

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Assuntos
Lentes de Contato , Óculos , Fixação Ocular , Presbiopia , Leitura , Refração Ocular , Acuidade Visual , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimentos Oculares/fisiologia , Fixação Ocular/fisiologia , Movimentos da Cabeça/fisiologia , Presbiopia/fisiopatologia , Presbiopia/terapia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Estudos Cross-Over , Estudos Prospectivos
12.
Nat Commun ; 15(1): 3588, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678013

RESUMO

Eye tracking techniques enable high-efficient, natural, and effortless human-machine interaction by detecting users' eye movements and decoding their attention and intentions. Here, a miniature, imperceptible, and biocompatible smart contact lens is proposed for in situ eye tracking and wireless eye-machine interaction. Employing the frequency encoding strategy, the chip-free and battery-free lens successes in detecting eye movement and closure. Using a time-sequential eye tracking algorithm, the lens has a great angular accuracy of <0.5°, which is even less than the vision range of central fovea. Multiple eye-machine interaction applications, such as eye-drawing, Gluttonous Snake game, web interaction, pan-tilt-zoom camera control, and robot vehicle control, are demonstrated on the eye movement model and in vivo rabbit. Furthermore, comprehensive biocompatibility tests are implemented, demonstrating low cytotoxicity and low eye irritation. Thus, the contact lens is expected to enrich approaches of eye tracking techniques and promote the development of human-machine interaction technology.


Assuntos
Algoritmos , Lentes de Contato , Movimentos Oculares , Tecnologia de Rastreamento Ocular , Movimentos Oculares/fisiologia , Animais , Humanos , Coelhos , Sistemas Homem-Máquina
14.
ACS Appl Mater Interfaces ; 16(17): 22522-22531, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651323

RESUMO

Flexible bioelectronic devices that can perform real-time and accurate intraocular pressure (IOP) monitoring in both clinical and home settings hold significant implications for the diagnosis and treatment of glaucoma, yet they face challenges due to the open physiological environment of the ocular. Herein, we develop an intelligent wireless measuring contact lens (WMCL) incorporating a dual inductor-capacitor-resistor (LCR) resonant system to achieve temperature self-compensation for quantitative IOP monitoring in different application environments. The WMCL utilizes a compact circuitry design, which enables the integration of low-frequency and high-frequency resonators within a single layer of a sensing circuit without causing visual impairment. Mechanically guided microscale 3D encapsulation strategy combined with flexible circuit printing techniques achieves the surface-adaptive fabrication of the WMCL. The specific design of frequency separation imparts distinct temperature response characteristics to the dual resonators, and the linear combination of the dual resonators can eliminate the impact of temperature variations on measurement accuracy. The WMCL demonstrates outstanding sensitivity and linearity in monitoring the IOP of porcine eyes in vitro while maintaining satisfactory measurement accuracy even with internal temperature variations exceeding 10 °C. Overcoming the impact of temperature variations on IOP monitoring from the system level, the WMCL showcases immense potential as the next generation of all-weather IOP monitoring devices.


Assuntos
Lentes de Contato , Pressão Intraocular , Temperatura , Tecnologia sem Fio , Pressão Intraocular/fisiologia , Tecnologia sem Fio/instrumentação , Animais , Suínos , Desenho de Equipamento , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Humanos
15.
Cont Lens Anterior Eye ; 47(3): 102173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38653594

RESUMO

PURPOSE: To investigate the short-term effect of scleral lens (SL) on corneal curvature and corneal oedema in Pellucid Marginal Degeneration (PMD) eyes. METHODS: Corneal anterior, posterior curvature and corneal thickness were measured in 14 eyes of 14 PMD participants with Schiempflug imaging at different corneal diameters and meridians at baseline and after 6 h of SL wear. RESULTS: There was a significant flattening (up to 0.26 mm) of the anterior corneal curvature noted in the inferotemporal quadrant (from 210 to 255 degree at 2 mm, 8 mm and 10 mm corneal diameter), inferonasal quadrant (from 285 to 345 degree at 6 mm and 8 mm corneal diameter), and inferiorly at 2 mm and 10 mm corneal diameter (p < 0.05). Similarly, posterior corneal curvature showed statistically significant steepening mostly in inferotemporal quadrants (from 195 to 255 degree from 4 mm to 8 mm corneal diameter) and inferonasally at 2 mm and 4 mm corneal diameter (p < 0.05). A statistically significant increase in the corneal thickness noted in different corneal diameters with corneal oedema ranging from 2.10 % to 4.00 % after 6 h of SL wear. A gradual increase in corneal oedema was noted form centre to periphery. The baseline central fluid reservoir thickness (FRT) was 341.07 ± 139.8 which reduced to 276.71 ± 114.32 µm after 6 h of lens wear. No significant correlation was noted between corneal oedema with different parameters like initial and final FRT, change in anterior and posterior corneal curvature, and lens thickness (p > 0.05). CONCLUSIONS: Short-term SL wear induced a clinically acceptable range of corneal oedema. A clinically significant flattening in anterior curvature and minimal steepening in posterior curvature were noted. Practitioners should be careful while measuring corneal parameters in PMD eyes wearing SL, as these alterations can provide false impression of disease progression.


Assuntos
Córnea , Edema da Córnea , Topografia da Córnea , Esclera , Humanos , Masculino , Feminino , Esclera/patologia , Córnea/patologia , Adulto , Edema da Córnea/etiologia , Edema da Córnea/fisiopatologia , Edema da Córnea/diagnóstico , Lentes de Contato , Distrofias Hereditárias da Córnea/fisiopatologia , Adulto Jovem , Pessoa de Meia-Idade , Acuidade Visual/fisiologia
16.
Biomacromolecules ; 25(5): 2728-2739, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38563621

RESUMO

Myopia is a global public health issue. Rigid contact lenses (RCLs) are an effective way to correct or control myopia. However, bioadhesion issues remain one of the significant obstacles limiting its clinical application. Although enhancing hydrophilicity through various surface treatments can mitigate this problem, the duration of effectiveness is short-lived and the processing involved is complex and costly. Herein, an antiadhesive RCLs material was designed via 8-armed methacrylate-POSS (8MA-POSS), and poly(ethylene glycol) methacrylate (PEGMA) copolymerization with 3-[tris(trimethylsiloxy)silyl] propyl methacrylate (TRIS). The POSS and PEG segments incorporated P(TRIS-co-PEGMA-co-8MA-POSS) (PTPM) material was obtained and their optical transparency, refractive index, resolution, hardness, surface charge, thermal features, and wettability were tested and optimized. The antibioadhesion activities, including protein, lipid, and bacteria, were evaluated as well. In vitro and in vivo results indicated that the optimized antibioadhesive PTPM materials present good biocompatibility and biosafety. Thus, such POSS and PEG segments containing material were a potential antibioadhesive RCL material option.


Assuntos
Lentes de Contato , Metacrilatos , Compostos de Organossilício , Polietilenoglicóis , Polietilenoglicóis/química , Metacrilatos/química , Animais , Compostos de Organossilício/química , Compostos de Organossilício/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Camundongos , Materiais Biocompatíveis/química , Humanos , Miopia/tratamento farmacológico
17.
Eye Contact Lens ; 50(6): 255-258, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38652487

RESUMO

OBJECTIVE: To evaluate the effects of rigid corneal lenses (RCL) in patients with keratoconus, based on eccentricity. METHODS: Eighty-four eyes from 84 patients were included in this retrospective comparative study. Based on the median value of eccentricity difference between the cornea and back surface of the RCL, the patients were divided into groups 1 (<0.08) and 2 (≥0.08). Visual acuity, refractive index, and corneal topography indices were compared before and three months after lens use. RESULTS: Visual acuity, astigmatism, refractive error, corneal curvature, and corneal thickness improved significantly in both groups. Apical power and anterior elevation improved significantly in group 1, with small differences in eccentricity, but not in group 2. Changes in apical power before and after lens use were significantly different between the two groups. CONCLUSION: The RCL was effective for the cornea of keratoconus, especially when the prescription was made with a small difference in eccentricity.


Assuntos
Lentes de Contato , Córnea , Topografia da Córnea , Ceratocone , Refração Ocular , Acuidade Visual , Humanos , Ceratocone/fisiopatologia , Ceratocone/terapia , Estudos Retrospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Adulto , Refração Ocular/fisiologia , Adulto Jovem , Córnea/patologia , Córnea/fisiopatologia , Adolescente , Astigmatismo/fisiopatologia , Astigmatismo/terapia , Pessoa de Meia-Idade
18.
In Vivo ; 38(3): 1229-1235, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38688617

RESUMO

BACKGROUND/AIM: Given the characteristics of Serratia marcescens (S. marcescens), this study aimed at investigating its presence in the hands and contact lens cases of orthokeratology wearers, along with the status of bacterial contamination. PATIENTS AND METHODS: The 39 patients received the questionnaires about the background of orthokeratology and hygiene habits. A total of 39 contact lens cases and 39 hand samples from the patients were collected at Show Chwan Memorial Hospital from June to August in 2020 and sent to National Chung Cheng University for DNA extraction and PCR identification. RESULTS: The results indicated a detection rate of 5.13% for S. marcescens in the contact lens cases and 12.82% in the hand samples. Additionally, 66.67% of contact lens case samples and 30.77% of hand samples found positive for 16s bacterial amplicons. The relationship between hand contamination and the duration of contact lens usage were revealed for both S. marcescens (p=0.021) and 16s bacterial amplicons (p=0.048). CONCLUSION: The results indicated that hand hygiene is more critical than focusing on contact lens hygiene when it comes to preventing S. marcescens infections. Nevertheless, both proper hand and contact lens hygiene practices can reduce the detection of bacterial eye pathogens, especially a common intestinal bacterium.


Assuntos
Infecções por Serratia , Serratia marcescens , Humanos , Serratia marcescens/isolamento & purificação , Serratia marcescens/genética , Masculino , Feminino , Infecções por Serratia/microbiologia , Infecções por Serratia/epidemiologia , Infecções por Serratia/diagnóstico , Procedimentos Ortoceratológicos/métodos , Lentes de Contato/microbiologia , Lentes de Contato/efeitos adversos , Criança , Adolescente , Higiene , Higiene das Mãos , Adulto , Mãos/microbiologia
19.
Medicine (Baltimore) ; 103(14): e37663, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579080

RESUMO

BACKGROUND: To report the nursing experience of a case of corneal contact lens wearer receiving the 2nd keratoplasty due to corneal ulcer and perforation caused by Pythium insidiosum infection. METHODS: A 30-year-old female patient had blurred vision after deep anterior lamellar keratoplasty for a right corneal ulcer. At the 5th week, the right eye appeared the symptoms, such as redness and pain. The anterior segment photography was performed on the eye, and the result showed that the epithelium was missing in the right eye lesion area, and a large number of longitudinal and transversal streaks were visible from the epithelium to the stroma, with fungus filaments to be discharged. Upon macro-genome sequencing of the corneal secretion, a P. insidiosum infection was observed. Then, the patient underwent the keratoplasty, and 3 weeks later, the corneal implant showed a tendency to dissolve, the sutures were partially loosened, and the eye was almost blind. Subsequently, the patient was admitted to our hospital and subject to the 2nd penetrating keratoplasty of the right eye (allograft). After surgery, linezolid and azithromycin injections were given through intravenous drip and local drip of the eye for anti-inflammation, and tacrolimus eye drops for antirejection. RESULTS: Postoperatively, the patient showed signs of recovery with slight corneal edema and visible pupil, leading to discharge with improved vision. The corneal implant was normal 1 week after surgery and the vision of the right eye was hand move/before eye at the 6th month of follow-up. Continuous care and removal of sutures 3 months post-surgery contributed to a successful outcome, with the patient achieving hand motion vision 6 months after the procedure. CONCLUSION: Corneal ulcer caused by P. insidiosum infection not only needs timely and effective keratoplasty intervention, but also requires perfect nursing measures.


Assuntos
Transplante de Córnea , Úlcera da Córnea , Pitiose , Adulto , Feminino , Humanos , Lentes de Contato , Córnea/cirurgia , Transplante de Córnea/métodos , Úlcera da Córnea/etiologia , Úlcera da Córnea/cirurgia , Ceratoplastia Penetrante , Pitiose/cirurgia , Pitiose/complicações , Pitiose/diagnóstico
20.
Turk J Ophthalmol ; 54(2): 103-107, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38645833

RESUMO

Facial burns involving the periorbital region may lead to cicatricial ectropion and lagophthalmos, causing severe exposure keratopathy and eventually blindness if uncorrected. In these patients, it is critical to provide aesthetic and functional surgical correction to protect the ocular surface from chronic desiccation in addition to visual rehabilitation. Conventional methods may not be sufficient to provide visual rehabilitation in complex cases. Scleral lenses can be a multipurpose alternative for these patients. Herein, we present the challenging case of a patient who developed cicatricial lagophthalmos and exposure keratopathy after facial transplantation due to gasoline burns and received a scleral contact lens for visual rehabilitation.


Assuntos
Lentes de Contato , Esclera , Humanos , Esclera/cirurgia , Transplante de Córnea/métodos , Acuidade Visual , Doença Crônica , Queimaduras Oculares/complicações , Queimaduras Oculares/cirurgia , Queimaduras Oculares/diagnóstico , Queimaduras Químicas/cirurgia , Queimaduras Químicas/complicações , Masculino , Doenças Palpebrais/cirurgia , Doenças Palpebrais/etiologia , Feminino , Lagoftalmia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...