1.
Artigo em Inglês | MEDLINE | ID: mdl-38839349

RESUMO

T-tubes and airway stents are commonly used but have limited effectiveness and frequent complications. A 50-year-old male patient presented with severe tracheal stenosis, affecting an 8.7 cm length of the airway. We employed an innovative approach known as external suspension fixation of tracheal stent using robotic assistance. This method involves surgically attaching the stent to the exterior of the trachea to provide support and stabilize the softened or collapsed tracheal segments. We designed a C-shaped nickel-titanium alloy exterior stent and successfully fixed it using robotic assistance. This intervention effectively restored tracheal function and led to a favorable postoperative recovery. The technique does not affect tracheal membrane function or airway mucociliary clearance. It could potentially be considered as a new option for treating long-segment benign tracheal softening or collapse.


Assuntos
Níquel , Desenho de Prótese , Procedimentos Cirúrgicos Robóticos , Stents , Titânio , Estenose Traqueal , Humanos , Masculino , Pessoa de Meia-Idade , Estenose Traqueal/cirurgia , Estenose Traqueal/diagnóstico por imagem , Estenose Traqueal/etiologia , Estenose Traqueal/fisiopatologia , Resultado do Tratamento , Ligas
2.
J Long Term Eff Med Implants ; 34(4): 83-94, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38842236

RESUMO

Powder-mixed electrical discharge machining (PMEDM) enhances the effectiveness of the electric discharge machining process. It has been used on the Mg alloy AZ91D to address biodegradation concerns in implants. By combining nano-conductive powder particles with the dielectric fluid, PMEDM creates a functional surface. Process parameters like pulse on time, pulse off time, peak current, and powder concentration are examined to optimize material removal rate (MRR), surface roughness (SR), and white layer thickness (WLT). The optimization of input parameters was completed using the Taguchi L9 technique and further analyzed using ANOVA technique that illustrates Ton and pulse-off time as more significant process parameters for powder mixed electric discharge machining as compared with electric potential and peak current. The optimal surface roughness value is found to be 2.215 µm at 3A pulse current and 15 µs Toff time which suggest the material to be suitable for implants.


Assuntos
Implantes Absorvíveis , Ligas , Magnésio , Propriedades de Superfície , Magnésio/química , Teste de Materiais , Pós
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 257-263, 2024 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-38863090

RESUMO

The treatment of bone defects caused by fractures or bone tissue lesions has always been a difficult problem in the field of orthopedics. Implantation of high-performance titanium alloy prosthesis is an effective method to treat bone defects. 3D printing technology can produce low-modulus titanium alloy implants with porous structures, providing a better solution to the above problems. This technology is convenient to design and has a huge advantage in making orthopedic implants. The article used electron beam melting in 3D printing technology to create two samples of Ti-6Al-4V prosthesis, including solid structural pelvic prosthesis and porous structural pelvic prosthesis. The mechanical properties of the prosthesis showed that the yield and tensile strengths of the rod tensile specimen were 894 MPa and 956 MPa, respectively, and the compressive modulus and compressive strength of the porous pelvic prosthesis were 55 GPa and 65.2 MPa, respectively. The results of the L929 cytotoxicity assay and the MC3T3-E1 cell adhesion assay demonstrated good biocompatibility of the prosthetic samples. New Zealand white rabbits were used to prepare the femoral joint cavity defect models and two pelvic prostheses were implanted. A microscopic CT scan 4 weeks after implantation showed that the bone defect caused by the drill had healed and that the porous structure of the pelvic prosthesis formed a new trabecular structure within the hole. In conclusion, the 3D printed Ti-6Al-4V pelvic prosthesis has excellent mechanical properties, biocompatibility, and the ability to promote new bone growth.


Assuntos
Ligas , Materiais Biocompatíveis , Teste de Materiais , Impressão Tridimensional , Titânio , Animais , Coelhos , Próteses e Implantes , Camundongos , Desenho de Prótese , Porosidade , Ossos Pélvicos , Pelve
4.
J Environ Manage ; 362: 121302, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38824896

RESUMO

Two industrial solid wastes, Ti-bearing blast furnace slag (TBFS) and diamond wire saw silicon waste (DWSSW), contain large amounts of Ti and Si, and their accumulation wastes resources and intensifies environmental pollution. In the present study, DWSSW was used as the silicon source to reduce titanium oxide in TBFS by electromagnetic induction smelting, and meanwhile Na3AlF6 was added as a flux to improve the recycling of the wastes. Ti and Si of the two wastes were simultaneously recovered in the form of alloy. The effects of different addition amount of Na3AlF6 flux in the mixture of DWSSW and TBFS on chemical composition, viscosity, basicity and structure of slag were investigated. The dissolution behavior of SiO2 in Na3AlF6 flux was theoretically deduced and experimentally verification. The optimized recovery rate of Ti and Si were obtained, and the research realizes the efficient recycling of DWSSW and TBFS simultaneously.


Assuntos
Ligas , Reciclagem , Silício , Titânio , Titânio/química , Silício/química , Ligas/química , Diamante/química , Resíduos Industriais/análise
5.
Int J Pediatr Otorhinolaryngol ; 181: 111994, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38823367

RESUMO

OBJECTIVE: Utilizing a novel histopathological scoring system and subglottic stenosis (SGS) rabbit model, we aimed to compare degrees of inflammation and severity of narrowing in the subglottis between two minimally invasive therapeutic modalities: endoscopic balloon dilation (EBD) alone versus EBD with placement of a bioabsorbable ultra-high ductility magnesium (UHD-Mg) alloy stent. METHODS: SGS was induced endoscopically via microsuspension laryngoscopy in 23 New Zealand white rabbits. The control group (n = 11) underwent EBD alone, the study arm (n = 12) underwent EBD with implantation of bioabsorbable UHD-Mg alloy stents. Rabbits were euthanized at 2-, 3-, and 6-weeks after SGS induction, coinciding with wound healing stages. Using Optical Coherence Tomography (OCT), cross-sectional areas of airways were compared to calculate the mean percentage of intraluminal area at sequential time points. A novel histopathological scoring system was used to analyze frozen sections of laryngotracheal complexes. The degree of inflammation was quantified by scoring changes in inflammatory cell infiltration, epithelial ulceration/metaplasia, subepithelial edema/fibrosis, and capillary number/dilation. Univariate analysis was utilized to analyze these markers. RESULTS: We found rabbits implanted with the bioabsorbable UHD-Mg alloy stent had statistically significantly higher scores in categories of hyperplastic change (stents vs controls: 1.48 vs 0.46 p < 0.001), squamous metaplasia (22 vs 5 p < 0.001), and neutrophils/fibrin in lumen (31 vs 8, p < 0.001). Rabbits who received EBD alone had higher scores of subepithelial edema and fibrosis (2.70 vs 3.49, p < 0.0256). The stented rabbits demonstrated significantly increased mean percent stenosis by intraluminal mean area compared to controls at 2 weeks (88.56 vs 58.98, p = 0.032), however at all other time points there was no significant difference between intraluminal subglottic stenosis by mean percent stenosis area. DISCUSSION: Rabbits with SGS treated with UHD-Mg alloy stents demonstrated histopathologic findings suggestive of lower levels of tracheal fibrosis. This could indicate a reduced tendency towards the development of stenosis when compared to EBD alone. There was not a difference in luminal size between stent and non-stented rabbits at the six-week end point. Histologically, however, overall the use of bioabsorbable UHD-Mg alloy stenting elicited a greater tissue response at the level of the superficial mucosa rather than fibrosis of the lamina propria seen in the stented rabbits. This suggests more favorable healing and less of a tendency towards fibrosis and stenosis even though there may not be a benefit from a luminal size standpoint during this early healing period. Compared to known complications of currently available non-bioabsorbable metal or silicone-based stents, this proof-of-concept investigation highlights the potential use of a novel biodegradable UHD-Mg stent as a therapeutic modality for pediatric SGS.


Assuntos
Implantes Absorvíveis , Ligas , Modelos Animais de Doenças , Laringoscopia , Laringoestenose , Magnésio , Stents , Animais , Coelhos , Laringoestenose/patologia , Laringoestenose/terapia , Inflamação/patologia , Dilatação/instrumentação , Índice de Gravidade de Doença
6.
Int J Nanomedicine ; 19: 5245-5267, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855732

RESUMO

The development of metallic joint prostheses has been ongoing for more than a century alongside advancements in hip and knee arthroplasty. Among the materials utilized, the Cobalt-Chromium-Molybdenum (Co-Cr-Mo) and Titanium-Aluminum-Vanadium (Ti-Al-V) alloys are predominant in joint prosthesis construction, predominantly due to their commendable biocompatibility, mechanical strength, and corrosion resistance. Nonetheless, over time, the physical wear, electrochemical corrosion, and inflammation induced by these alloys that occur post-implantation can cause the release of various metallic components. The released metals can then flow and metabolize in vivo, subsequently causing potential local or systemic harm. This review first details joint prosthesis development and acknowledges the release of prosthetic metals. Second, we outline the metallic concentration, biodistribution, and elimination pathways of the released prosthetic metals. Lastly, we discuss the possible organ, cellular, critical biomolecules, and significant signaling pathway toxicities and adverse effects that arise from exposure to these metals.


Assuntos
Metais , Humanos , Animais , Metais/química , Metais/farmacocinética , Próteses Articulares Metal-Metal/efeitos adversos , Distribuição Tecidual , Titânio/química , Titânio/farmacocinética , Titânio/toxicidade , Titânio/efeitos adversos , Prótese Articular/efeitos adversos , Desenho de Prótese , Ligas/farmacocinética , Ligas/química , Ligas/toxicidade
7.
ACS Appl Bio Mater ; 7(6): 3900-3914, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38840339

RESUMO

The poor clinical performance of titanium and its alloy implants is mainly attributed to their lack of antibacterial ability and poor osseointegration. The key and challenge lie in how to enhance their osteoinductivity while imparting antibacterial capability. In this study, a titanium oxide metasurface with light-responsive behavior was constructed on the surface of titanium alloy using an alkaline-acid bidirectional hydrothermal method. The effects of the acid type, acid concentration, hydrothermal time, hydrothermal temperature, and subsequent heat treatments on the optical behavior of the metasurface were systematically investigated with a focus on exploring the influence of the metasurface and photodynamic reaction on the osteogenic activity of osteoblasts. Results show that the type of acid and heat treatment significantly affect the light absorption of the titanium alloy surface, with HCl and post-heat-treatment favoring redshift in the light absorption. Under 808 nm near-infrared (NIR) irradiation for 10 min, in vitro antibacterial experiments demonstrate that the antibacterial rate of the metasurface titanium alloy against Staphylococcus aureus and Escherichia coli were 96.87% and 99.27%, respectively. In vitro cell experiments demonstrate that the nanostructure facilitates cell adhesion, proliferation, differentiation, and expression of osteogenic-related genes. Surprisingly, the nanostructure promoted the expression of relevant osteogenic genes of MC3T3-E1 under 808 nm NIR irradiation. This study provides a method for the surface modification of titanium alloy implants.


Assuntos
Ligas , Antibacterianos , Materiais Biocompatíveis , Escherichia coli , Raios Infravermelhos , Teste de Materiais , Nanoestruturas , Staphylococcus aureus , Propriedades de Superfície , Titânio , Titânio/química , Titânio/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Staphylococcus aureus/efeitos dos fármacos , Ligas/química , Ligas/farmacologia , Escherichia coli/efeitos dos fármacos , Nanoestruturas/química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Testes de Sensibilidade Microbiana , Tamanho da Partícula , Animais , Camundongos , Osteogênese/efeitos dos fármacos , Osteoblastos/efeitos dos fármacos , Osteoblastos/citologia , Proliferação de Células/efeitos dos fármacos , Osseointegração/efeitos dos fármacos
8.
J Appl Biomater Funct Mater ; 22: 22808000231214359, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38702952

RESUMO

Exploring high strength materials with a higher concentration of reinforcements in the alloy proves to be a challenging task. This research has explored magnesium-based composites (AZ31B alloy) with tungsten carbide reinforcements, enhancing strength for medical joint replacements via league championship optimisation. The primary objective is to enhance medical joint replacement biomaterials employing magnesium-based composites, emphasising the AZ31B alloy with tungsten carbide reinforcements. The stir casting method is utilised in the manufacture of magnesium matrix composites (MMCs), including varied percentages of tungsten carbide (WC). The mechanical characteristics, such as micro-hardness, tensile strength, and yield strength, have been assessed and compared with computational simulations. The wear studies have been carried out to analyse the tribological behaviour of the composites. Additionally, this study investigates the prediction of stress and the distribution of forces inside bone and joint structures, therefore offering significant contributions to the field of biomedical research. This research contemplates the use of magnesium-based MMCs for the discovery of biomaterials suitable for medical joint replacement. The study focuses on the magnesium alloy AZ31B, with particles ranging in size from 40 to 60 microns used as the matrix material. Moreover, the outcomes have revealed that when combined with MMCs based on AZ31B-magnesium matrix, the WC particle emerges as highly effective reinforcements for the fabrication of lightweight, high-strength biomedical composites. This study uses the league championship optimisation (LCO) approach to identify critical variables impacting the synthesis of Mg MMCs from an AZ31B-based magnesium alloy. The scanning electron microscopy (SEM) images are meticulously analysed to depict the dispersion of WC particulates and the interface among the magnesium (Mg) matrix and WC reinforcement. The SEM analysis has explored the mechanisms underlying particle pull-out, the characteristics of inter-particle zones, and the influence of the AZ31B matrix on the enhancement of the mechanical characteristics of the composites. The application of finite element analysis (FEA) is being used in order to make predictions regarding the distribution of stress and the interactions of forces within the model of the hip joint. This study has compared the physico-mechanical and tribological characteristics of WC to distinct combinations of 0%, 5%, 10% and 15%, and its impact on the performance improvements. SEM analysis has confirmed the findings' improved strength and hardness, particularly when 10%-15% of WC was incorporated. Following the incorporation of 10% of WC particles within Mg-alloy matrix, the outcomes of the study has exhibited enhanced strength and hardness, which furthermore has been evident by utilising SEM analysis. Using ANSYS, structural deformation and stress levels are predicted, along with strength characteristics such as additional hardness of 71 HRC, tensile strength of 140-150 MPa, and yield strength closer to 100-110 MPa. The simulations yield significant insights into the behaviour of the joint under various loading conditions, thus enhancing the study's significance in biomedical environments.


Assuntos
Ligas , Magnésio , Teste de Materiais , Ligas/química , Magnésio/química , Compostos de Tungstênio/química , Materiais Biocompatíveis/química , Humanos , Resistência à Tração , Articulação do Quadril
9.
PLoS One ; 19(5): e0302729, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38743667

RESUMO

The constitutive model and modulus parameter equivalence of shape memory alloy composites (SMAC) serve as the foundation for the structural dynamic modeling of composite materials, which has a direct impact on the dynamic characteristics and modeling accuracy of SMAC. This article proposes a homogenization method for SMA composites considering interfacial phases, models the interface stress transfer of three-phase cylinders physically, and derives the axial and shear stresses of SMA fiber phase, interfacial phase, and matrix phase mathematically. The homogenization method and stress expression were then used to determine the macroscopic effective modulus of SMAC as well as the stress characteristics of the fiber phase and interface phase of SMA. The findings demonstrate the significance of volume fraction and tensile pre-strain in stress transfer between the fiber phase and interface phase at high temperatures. The maximum axial stress in the fiber phase is 705.05 MPa when the SMA is fully austenitic and the pre-strain increases to 5%. At 10% volume fraction of SMA, the fiber phase's maximum axial stress can reach 1000 MPa. Ultimately, an experimental verification of the theoretical calculation method's accuracy for the effective modulus of SMAC lays the groundwork for the dynamic modeling of SMAC structures.


Assuntos
Ligas , Estresse Mecânico , Resistência à Tração , Ligas/química , Teste de Materiais/métodos , Módulo de Elasticidade , Materiais Inteligentes/química , Modelos Teóricos
10.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241257169, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38769768

RESUMO

Background: The purpose of this study was to investigate the effect of 3D-printed technology to repair glenoid bone defect on shoulder joint stability. Methods: The shoulder joints of 25 male cadavers were tested. The 3D-printed glenoid pad was designed and fabricated. The specimens were divided into 5 groups. Group A: no bone defect and the structure of the glenoid labrum and joint capsule was intact; Group B: Anterior inferior bone defect of the shoulder glenoid; Group C: a pad with a width of 2 mm was installed; Group D: a pad with a width of 4 mm was installed; Group E: a pad with a width of 6 mm was installed. This study measured the distance the humeral head moved forward at the time of glenohumeral dislocation and the maximum load required to dislocate the shoulder. Results: The shoulder joint stability and humerus displacement was significantly lower in groups B and C compared with group A (p < .05). Compared with group A, the stability of the shoulder joint of group D was significantly improved (p < .05). However, there was no significant difference in humerus displacement between groups D and A (p > .05). In addition, compared with group A, shoulder joint stability was significantly increased and humerus displacement was significantly decreased in group E (p < .05). Conclusion: The 3D-printed technology can be used to make the shoulder glenoid pad to perfectly restore the geometric shape of the shoulder glenoid articular surface. Moreover, the 3D-printed pad is 2 mm larger than the normal glenoid width to restore the initial stability of the shoulder joint.


Assuntos
Ligas , Cadáver , Impressão Tridimensional , Articulação do Ombro , Titânio , Humanos , Masculino , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Fenômenos Biomecânicos , Instabilidade Articular/cirurgia , Instabilidade Articular/fisiopatologia , Cavidade Glenoide/cirurgia , Desenho de Prótese
11.
J Biomed Mater Res B Appl Biomater ; 112(6): e35415, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38773744

RESUMO

This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1-15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5-5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.


Assuntos
Ligas , Durapatita , Teste de Materiais , Titânio , Zircônio , Zircônio/química , Durapatita/química , Ligas/química , Titânio/química , Entropia , Nióbio/química , Materiais Biocompatíveis/química
12.
J Orthop Surg Res ; 19(1): 304, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769535

RESUMO

BACKGROUND: Periprosthetic joint infection is a serious complication following joint replacement. The development of bacterial biofilms bestows antibiotic resistance and restricts treatment via implant retention surgery. Electromagnetic induction heating is a novel technique for antibacterial treatment of metallic surfaces that has demonstrated in-vitro efficacy. Previous studies have always employed stationary, non-portable devices. This study aims to assess the in-vitro efficacy of induction-heating disinfection of metallic surfaces using a new Portable Disinfection System based on Induction Heating. METHODS: Mature biofilms of three bacterial species: S. epidermidis ATCC 35,984, S. aureus ATCC 25,923, E. coli ATCC 25,922, were grown on 18 × 2 mm cylindrical coupons of Titanium-Aluminium-Vanadium (Ti6Al4V) or Cobalt-chromium-molybdenum (CoCrMo) alloys. Study intervention was induction-heating of the coupon surface up to 70ºC for 210s, performed using the Portable Disinfection System (PDSIH). Temperature was monitored using thermographic imaging. For each bacterial strain and each metallic alloy, experiments and controls were conducted in triplicate. Bacterial load was quantified through scraping and drop plate techniques. Data were evaluated using non-parametric Mann-Whitney U test for 2 group comparison. Statistical significance was fixed at p ≤ 0.05. RESULTS: All bacterial strains showed a statistically significant reduction of CFU per surface area in both materials. Bacterial load reduction amounted to 0.507 and 0.602 Log10 CFU/mL for S. aureus on Ti6Al4V and CoCrMo respectively, 5.937 and 3.500 Log10 CFU/mL for E. coli, and 1.222 and 0.372 Log10 CFU/mL for S. epidermidis. CONCLUSIONS: Electromagnetic induction heating using PDSIH is efficacious to reduce mature biofilms of S aureus, E coli and S epidermidis growing on metallic surfaces of Ti6Al4V and CoCrMo alloys.


Assuntos
Ligas , Biofilmes , Desinfecção , Escherichia coli , Infecções Relacionadas à Prótese , Staphylococcus aureus , Titânio , Biofilmes/efeitos dos fármacos , Desinfecção/métodos , Escherichia coli/crescimento & desenvolvimento , Staphylococcus aureus/efeitos dos fármacos , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/microbiologia , Staphylococcus epidermidis/efeitos dos fármacos , Prótese Articular/microbiologia , Artroplastia de Substituição/instrumentação , Artroplastia de Substituição/métodos , Calefação/instrumentação , Calefação/métodos , Humanos , Fenômenos Eletromagnéticos , Vitálio
13.
BMC Oral Health ; 24(1): 564, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38745154

RESUMO

BACKGROUND: Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting clinical progress and outcome. Numerous studies have confirmed the correlation between alloy corrosion and raised surface roughness, which has a direct impact on the working characteristics of orthodontic archwires. METHODS: Thirty nickel-titanium (NiTi) orthodontic archwires were utilized in this study. Patients were randomly selected and allocated into three groups according to the randomization plan; (The control group): subjects practiced regular oral hygiene; (The fluoride group): subjects used fluoride for intensive prophylaxis; (The chlorhexidine group): subjects used chlorhexidine. Representative samples were evaluated by SEM, and then SEM images with high resolution were examined using Image J software to determine the surface roughness and obtain the results for further statistical analysis. RESULTS: Our findings indicated a significant difference was found between the three groups regarding the anterior and posterior parts between the control and the two other groups and a non-significant difference between NaF and CHX groups. Overall, the p-value for group comparisons was 0.000 for both parts, indicating a highly significant difference especially between the control and NaF groups. CONCLUSION: Mouthwashes containing sodium fluoride demonstrated more significant surface alterations than the control and CHX groups and should be prescribed in accordance with orthodontic materials to reduce side effects.


Assuntos
Ligas , Clorexidina , Ligas Dentárias , Microscopia Eletrônica de Varredura , Níquel , Fios Ortodônticos , Fluoreto de Sódio , Propriedades de Superfície , Humanos , Fluoreto de Sódio/uso terapêutico , Clorexidina/uso terapêutico , Corrosão , Ligas Dentárias/química , Níquel/química , Titânio/química , Cariostáticos/uso terapêutico , Cariostáticos/química , Masculino , Feminino , Adulto Jovem , Antissépticos Bucais/uso terapêutico , Antissépticos Bucais/química , Processamento de Imagem Assistida por Computador/métodos , Adolescente , Adulto , Higiene Bucal
14.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 535-541, 2024 May 15.
Artigo em Chinês | MEDLINE | ID: mdl-38752238

RESUMO

Objective: To evaluate the effectiveness of using titanium alloy trabecular bone three-dimensional (3D) printed artificial vertebral body in treating cervical ossification of the posterior longitudinal ligament (OPLL). Methods: A retrospective analysis was conducted on clinical data from 45 patients with cervical OPLL admitted between September 2019 and August 2021 and meeting the selection criteria. All patients underwent anterior cervical corpectomy and decompression, interbody bone graft fusion, and titanium plate internal fixation. During operation, 21 patients in the study group received titanium alloy trabecular bone 3D printed artificial vertebral bodies, while 24 patients in the control group received titanium cages. There was no significant difference in baseline data such as gender, age, disease duration, affected segments, or preoperative pain visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), vertebral height, and C 2-7Cobb angle ( P>0.05). Operation time, intraoperative blood loss, and occurrence of complications were recorded for both groups. Preoperatively and at 3 and 12 months postoperatively, the functionality and symptom relief were assessed using JOA scores, VAS scores, and NDI evaluations. The vertebral height and C 2-7 Cobb angle were detected by imaging examinations and the implant subsidence and intervertebral fusion were observed. Results: The operation time and incidence of complications were significantly lower in the study group than in the control group ( P<0.05), while the difference in intraoperative blood loss between the two groups was not significant ( P>0.05). All patients were followed up 12-18 months, with the follow-up time of (14.28±4.34) months in the study group and (15.23±3.54) months in the control group, showing no significant difference ( t=0.809, P=0.423). The JOA score, VAS score, and NDI of the two groups improved after operation, and further improved at 12 months compared to 3 months, with significant differences ( P<0.05). At each time point, the study group exhibited significantly higher JOA scores and improvement rate compared to the control group ( P<0.05); but there was no significantly difference in VAS score and NDI between the two groups ( P>0.05). Imaging re-examination showed that the vertebral height and C 2-7Cobb angle of the two groups significantly increased at 3 and 12 months after operation ( P<0.05), and there was no significant difference between 3 and 12 months after operation ( P>0.05). At each time point, the vertebral height and C 2-7Cobb angle of the study group were significantly higher than those of the control group ( P<0.05), and the implant subsidence rate was significantly lower than that of the control group ( P<0.05). However, there was no significant difference in intervertebral fusion rate between the two groups ( P>0.05). Conclusion: Compared to traditional titanium cages, the use of titanium alloy trabecular bone 3D-printed artificial vertebral bodies for treating cervical OPLL results in shorter operative time, fewer postoperative complications, and lower implant subsidence rates, making it superior in vertebral reconstruction.


Assuntos
Ligas , Vértebras Cervicais , Ossificação do Ligamento Longitudinal Posterior , Impressão Tridimensional , Fusão Vertebral , Titânio , Humanos , Ossificação do Ligamento Longitudinal Posterior/cirurgia , Vértebras Cervicais/cirurgia , Estudos Retrospectivos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Descompressão Cirúrgica/métodos , Osso Esponjoso , Resultado do Tratamento , Corpo Vertebral/cirurgia , Feminino , Masculino , Placas Ósseas , Pessoa de Meia-Idade
15.
ACS Appl Mater Interfaces ; 16(19): 24274-24294, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38699930

RESUMO

In the field of bone tissue engineering, recently developed Zn alloy scaffolds are considered potential candidates for biodegradable implants for bone regeneration and defect reconstruction. However, the clinical success of these alloys is limited due to their insufficient surface bioactivities. Further, the higher concentration of Zn2+ produced during degradation promotes antibacterial activity, but deteriorates osteogenic properties. This study fabricated an Azadirachta indica (neem)-assisted brushite-hydroxyapatite (HAp) coating on the recently developed Zn-2Cu-0.5Mg alloy to tackle the above dilemma. The microstructure, degradation behavior, antibacterial activity, and hemocompatibility, along with in vitro and in vivo cytocompatibility of the coated alloys, are systematically investigated. Microstructural analysis reveals flower-like morphology with uniformly grown flakes for neem-assisted deposition. The neem-assisted deposition significantly improves the adhesion strength from 12.7 to 18.8 MPa, enhancing the mechanical integrity. The potentiodynamic polarization study shows that the neem-assisted deposition decreases the degradation rate, with the lowest degradation rate of 0.027 mm/yr for the ZHN2 sample. In addition, the biomineralization process shows the apatite formation on the deposited coating after 21 days of immersion. In vitro cytotoxicity assay exhibits the maximum cell viability of 117% for neem-assisted coated alloy in 30% extract after 5d and the improved cytocompatibility which is due to the controlled release of Zn2+ ions. Meanwhile, neem-assisted coated alloy increases the ZOI by 32 and 24% for Gram-positive and Gram-negative bacteria, respectively. Acceptable hemolysis (<5%) and anticoagulation parameters demonstrate a promising hemocompatibility of the coated alloy. In vivo implantation illustrates a slight inflammatory response and vascularization after 2 weeks of subcutaneous implantation, and neo-bone formation in the defect areas of the rat femur. Micro-CT and histology studies demonstrate better osseointegration with satisfactory biosafety response for the neem-assisted coated alloy as compared to that without neem-assisted deposition. Hence, this neem-assisted brushite-Hap coating strategy elucidates a new perspective on the surface modification of biodegradable implants for the treatment of bone defects.


Assuntos
Ligas , Fosfatos de Cálcio , Materiais Revestidos Biocompatíveis , Zinco , Ligas/química , Ligas/farmacologia , Zinco/química , Zinco/farmacologia , Animais , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Fosfatos de Cálcio/química , Fosfatos de Cálcio/farmacologia , Antibacterianos/química , Antibacterianos/farmacologia , Humanos , Durapatita/química , Durapatita/farmacologia , Teste de Materiais , Camundongos , Química Verde , Implantes Absorvíveis
16.
ACS Appl Mater Interfaces ; 16(19): 24321-24340, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38700914

RESUMO

In current clinical practices related to orthopedics, dental, and cardiovascular surgeries, a number of biomaterial coatings, such as hydroxyapatite (HAp), diamond-like carbon (DLC), have been used in combination with metallic substrates (stainless steel, Ti6Al4V alloy, etc.). Although SiBCN coatings are widely explored in material science for diverse applications, their potential remains largely unexplored for biomedical applications. With this motivation, the present work reports the development of SiBxCyNzOm coatings on a Ti6Al4V substrate, employing a reactive radiofrequency (RF) magnetron sputtering technique. Three different coating compositions (Si0.27B0.10C0.31N0.07O0.24, Si0.23B0.06C0.21N0.22O0.27, and Si0.20B0.05C0.19N0.20O0.35) were obtained using a Si2BC2N target and varying nitrogen flow rates. The hydrophilic properties of the as-synthesized coatings were rationalized in terms of an increase in the number of oxygen-containing functional groups (OH and NO) on the surface, as probed using XPS and FTIR analyses. Furthermore, the cellular monoculture of SVEC4-10 endothelial cells and L929 fibroblasts established good cytocompatibility. More importantly, the coculture system of SVEC4-10 and L929, in the absence of growth factors, demonstrated clear cellular phenotypical changes, with extensive sprouting leading to tube-like morphologies on the coating surfaces, when stimulated using a customized cell stimulator (StimuCell) with 1.15 V/cm direct current (DC) electric field strength for 1 h. In addition, the hemocompatibility assessment using human blood samples revealed clinically acceptable hemolysis, less erythrocyte adhesion, shorter plasma recalcification, and reduced risk for thrombosis on the SiBxCyNzOm coatings, when compared to uncoated Ti6Al4V. Taken together, the present study unambiguously establishes excellent cytocompatibility, hemocompatibility, and defines the preangiogenic properties of SiBxCyNzOm bioceramic coatings for potential biomedical applications.


Assuntos
Ligas , Materiais Revestidos Biocompatíveis , Teste de Materiais , Titânio , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Ligas/química , Ligas/farmacologia , Titânio/química , Titânio/farmacologia , Humanos , Animais , Camundongos , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/citologia , Linhagem Celular , Propriedades de Superfície , Fibroblastos/efeitos dos fármacos , Fibroblastos/citologia , Neovascularização Fisiológica/efeitos dos fármacos
17.
BMC Surg ; 24(1): 169, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811965

RESUMO

BACKGROUND: Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS: An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS: With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS: Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.


Assuntos
Ligas , Benzofenonas , Análise de Elementos Finitos , Cetonas , Vértebras Lombares , Polietilenoglicóis , Polímeros , Fusão Vertebral , Titânio , Humanos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Materiais Biocompatíveis
18.
Sci Rep ; 14(1): 11748, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783056

RESUMO

The present study aimed to evaluate the outcomes of percutaneous treatment of aortic coarctation using self-expandable uncovered Nitinol stents. We conducted a retrospective clinical data review of all patients with aortic coarctation and treated with self-expandable uncovered Nitinol stents at our institution between 2009 and 2019. The gradient pressure across the coarctation site was measured using aortography. Follow-up echocardiography and computed tomography angiography were performed to assess possible stent complications. A total of 127 stents were successfully implanted in 125 patients (64.8% males) with a mean age of 35.36 ± 11.9 years. The gradient across the coarctation site decreased significantly from 67.48 ± 14.79 to 5.04 ± 3.01 mmHg (P < 0.001) after self-expandable stent implantation. Systolic blood pressure (SBP) decreased significantly from 175.53 ± 15.99 to 147.22 ± 12.83 mmHg (P < 0.001) after self-expandable stenting. There were no major technical or clinical complications, including balloon rupture, aneurysmal formation, infection, secondary stent migration, thrombosis, death during the procedure, and in-hospital mortality. On a mean follow-up of 48 ± 23.6 months (12-120 months), the gradient [from 59.43 ± 15.42 to 3.72 ± 1.38 mmHg (P < 0.001)] and SBP [from 175.53 ± 15.99 to 127.99 ± 7.82 mmHg (P < 0.001)] decreased significantly. There was no mortality, aneurysmal formation in the stent site, dislocation, or aortic re-stenosis requiring intervention during mid-term follow-up. Treatment of aortic coarctation using a self-expandable uncovered nitinol stent is safe and effective with promising mid-term outcomes.


Assuntos
Coartação Aórtica , Humanos , Coartação Aórtica/cirurgia , Coartação Aórtica/terapia , Masculino , Feminino , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Pessoa de Meia-Idade , Stents Metálicos Autoexpansíveis/efeitos adversos , Ligas , Stents/efeitos adversos , Angiografia por Tomografia Computadorizada , Adulto Jovem , Seguimentos
19.
ACS Sens ; 9(5): 2395-2401, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38722860

RESUMO

PdNi alloy thin films demonstrate exceptional hydrogen sensing performance and exhibit significant potential for application in surface acoustic wave (SAW) hydrogen sensors. However, the long-term stability of SAW H2 sensors utilizing PdNi films as catalysts experiences a substantial decrease during operation. In this paper, X-ray photoelectron spectroscopy (XPS) is employed to investigate the failure mechanisms of PdNi thin films under operational conditions. The XPS analysis reveals that the formation of PdO species on PdNi thin films plays a crucial role in the failure of hydrogen sensing. Additionally, density functional theory (DFT) calculations indicate that hydrogen atoms encounter a diffusion energy barrier during the penetration process from the PdNiOx surface to the subsurface region. The identification of PdNi film failure mechanisms through XPS and DFT offers valuable insights into the development of gas sensors with enhanced long-term stability. Guided by these mechanisms, we propose a method to restore the hydrogen sensing response time and magnitude to a certain extent by reducing the partially oxidized surface of the PdNi alloy under a hydrogen atmosphere at 70 °C, thereby restoring Pd to its metallic state with zero valence.


Assuntos
Hidrogênio , Níquel , Oxirredução , Paládio , Som , Hidrogênio/química , Paládio/química , Níquel/química , Propriedades de Superfície , Teoria da Densidade Funcional , Espectroscopia Fotoeletrônica , Ligas/química
20.
Int J Mol Sci ; 25(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38791360

RESUMO

Overly fast corrosion degradation of biodegradable magnesium alloys has been a major problem over the last several years. The development of protective coatings by using biocompatible, biodegradable, and non-toxic material such as chitosan ensures a reduction in the rate of corrosion of Mg alloys in simulated body fluids. In this study, chitosan/TiO2 nanocomposite coating was used for the first time to hinder the corrosion rate of Mg19Zn1Ca alloy in Hank's solution. The main goal of this research is to investigate and explain the corrosion degradation mechanism of Mg19Zn1Ca alloy coated by nanocomposite chitosan-based coating. The chemical composition, structural analyses, and corrosion tests were used to evaluate the protective properties of the chitosan/TiO2 coating deposited on the Mg19Zn1Ca substrate. The chitosan/TiO2 coating slows down the corrosion rate of the magnesium alloy by more than threefold (3.6 times). The interaction of TiO2 (NPs) with the hydroxy and amine groups present in the chitosan molecule cause their uniform distribution in the chitosan matrix. The chitosan/TiO2 coating limits the contact of the substrate with Hank's solution.


Assuntos
Ligas , Quitosana , Materiais Revestidos Biocompatíveis , Magnésio , Titânio , Quitosana/química , Titânio/química , Ligas/química , Corrosão , Magnésio/química , Materiais Revestidos Biocompatíveis/química , Zinco/química , Teste de Materiais , Cálcio/química , Nanocompostos/química