Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.124
Filtrar
1.
BMC Oral Health ; 24(1): 528, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702714

RESUMO

OBJECTIVES: To evaluate in the absence of teeth the variability of the mylohyoid line (ML), the microarchitecture of the adjacent bone, and whether the variable prominence/width of the ML is associated with the quality of the adjacent bone. METHODS: µCT scans of 28 human mandibles from anatomical specimens were analyzed. The following parameters were assessed in four edentulous areas (first and second premolar (PM), first, second, and third molar (M1/2/3)): ML width, cortical thickness (CtTh), average cortical- (Avg.Ct.BV/TV), and trabecular bone volume fraction (Avg.Tb.BV/TV). RESULTS: The ML width increased from the PM towards the M2 region, which also showed the highest variance (range: 0.4-10.2 mm). The CtTh showed a decrease in the M3 region, while Avg.Ct.BV/TV and Avg.Tb.BV/TV hardly differed among the regions. In the multivariable model on the effect of the various parameters on the ML width, only gender and tooth region were significant. Specifically, male specimens were associated with a wider ML width compared to female specimens and the M2 region was associated with a wider ML width compared to the other tooth regions. CONCLUSION: The ML width was not associated with the cortical and trabecular bone quality in the adjacent bone, while gender and tooth region had a significant effect. Specifically, the ML width was lower in female, but peaked in the M2 region with a median width of 3-4 mm. CLINICAL RELEVANCE: From a clinical point of view, it was confirmed that the ML is in general a highly variable structure, especially in the M2 region, but the ML width does not allow any conclusions on the bone quality. Altogether, this underlines the need for an individual and accurate diagnostic prior to any surgical intervention.


Assuntos
Mandíbula , Microtomografia por Raio-X , Humanos , Masculino , Feminino , Mandíbula/diagnóstico por imagem , Mandíbula/anatomia & histologia , Idoso , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/patologia , Processo Alveolar/anatomia & histologia , Pessoa de Meia-Idade , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/patologia
3.
J Dent ; 145: 104982, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38583644

RESUMO

OBJECTIVES: To report the implant survival rates, clinical, and radiographic status after a period of more than 5 years in the function of 4 inter-foraminal implants retaining mandibular overdentures (OVDs) in individuals with T2DM. METHODS: 78 completely edentulous participants with type 2 diabetic mellitus (T2DM) who had worn mandibular OVDs retained by 4 inter-foraminal implants for long-term functional life were selected for this study. The participants were divided into 2 groups according to glycosylated haemoglobin A1c (HbA1c) levels before implant placement: group I with an HbA1c value > 6.5 % (inadequately controlled T2DM), and group II with an HbA1c value ≤6.5 % (well-controlled T2DM). The inadequately controlled T2DM was further subdivided into 2 groups: Group IA with an HbA1c value > 6.5 % and ≤8 % (moderately controlled), and Group IB has an HbA1c value > 8 % (poorly controlled). Implant survival rate, plaque index (PI), bleeding on probing (BOP), probing depth (PD), and radiographic crestal bone level (CBL) around implants were measured. RESULTS: Among 312 implants, 6 failed, 4 in well-controlled diabetics, and 2 in inadequately controlled diabetics. The overall survival rate was 98.07 %. The mean PI in group Ι was 36.4 (group IA =37.76, group IB = 34.27), and in group ΙΙ it was 19. The mean BOP in group Ι was 45.5 (group IA =47.84, group IB = 41.76), and in group ΙΙ it was 22. The mean PD in group Ι was 4.1 (group IA =4.3, group IB = 3.85) and in group ΙΙ was 2.2. The mean radiographic CBL in group Ι was 3.4 (group IA =3.7, group IB = 2.9), and in group ΙΙ was 1.5. Group IA exhibited a significantly greater level of PI, BOP, PD, and CBL compared to group IB and group IΙ (P1=0.017, P2=0.001). CONCLUSIONS: Individuals with T2DM can benefit from 4 inter-foraminal implants retained mandibular OVDs, and their inability to maintain proper glucose control may not exclude implant success. CLINICAL SIGNIFICANCE: This study is a significant step toward improving knowledge of options available for treatment and anticipated outcomes for T2DM completely edentulous populations undergoing implant therapy.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Mandíbula , Humanos , Diabetes Mellitus Tipo 2/complicações , Masculino , Hemoglobinas Glicadas/análise , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Idoso , Resultado do Tratamento , Índice de Placa Dentária , Índice Periodontal , Perda do Osso Alveolar/diagnóstico por imagem , Prótese Total Inferior , Retenção de Dentadura , Falha de Restauração Dentária , Arcada Edêntula/diagnóstico por imagem
4.
J Dent ; 145: 105017, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38657725

RESUMO

OBJECTIVES: This observational study aimed to evaluate the accuracy of robotic computer-assisted implant surgery (r-CAIS) for full-arch immediate restoration and to analyse possible factors contributing to deviations. METHODS: Three edentulous patients (five arches) underwent r-CAIS. Osteotomies were performed using an autonomous robot under the surgeon's supervision, and implant placement was performed in a freehand or robotic manner. Prefabricated provisional prostheses were delivered immediately after surgery. Postoperative cone beam computed tomography scans were performed to assess the deviations between the planned and placed implants. Statistics were compared with deviations of s-CAIS outlined in a meta-analysis. RESULTS: A sum of 28 implants were used. The mean global coronal and apical deviations measured 0.91 ± 0.43 mm and 1.01 ± 0.45 mm, respectively, and the mean angular deviation measured 1.21 ± 1.24 º. The r-CAIS showed significantly better precision than the s-CAIS in full-arch cases (P < 0.001). The implants inserted using the robotic arm exhibited fewer deviations than those placed in the freehand manner. Eighty percent of prefabricated provisional prostheses were successfully delivered. CONCLUSIONS: Within the limitations of the present study, our data suggest that autonomous r-CAIS is a feasible approach for simultaneous immediate restoration in edentulous patients, showing better accuracy than s-CAIS. Further large-scale studies are necessary to verify the advantages and disadvantages of this novel technique and to explore possible factors that influence its accuracy. CLINICAL SIGNIFICANCE: Autonomous r-CAIS can provide clinically acceptable implant placement accuracy in edentulous patients, significantly surpassing s-CAIS. This level of accuracy may represent a viable therapeutic approach for simultaneous immediate full-arch restoration.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Masculino , Feminino , Cirurgia Assistida por Computador/métodos , Implantação Dentária Endóssea/métodos , Pessoa de Meia-Idade , Idoso , Carga Imediata em Implante Dentário/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Prótese Dentária Fixada por Implante , Arcada Edêntula/cirurgia , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/reabilitação , Osteotomia/métodos , Osteotomia/instrumentação , Resultado do Tratamento , Maxila/cirurgia , Maxila/diagnóstico por imagem
5.
Shanghai Kou Qiang Yi Xue ; 33(1): 90-96, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38583032

RESUMO

PURPOSE: To observe the long-term clinical effect of implants retained complete overdentures with Locator attachments. METHODS: A total of 48 patients with edentulous jaws treated with implants retained complete overdentures with Locator attachments were selected from the Outpatient Department of Peking University School and Hospital of Stomatology from 2016 to 2017. Among them, 21 patients underwent double-maxillary complete overdentures restoration and 27 patients underwent single-maxillary restoration. A total of 230 implants were implanted. The clinical observation indicators included the implant survival rate, peri-implant mucosal bleeding on probing(BOP), the change in the vertical height of alveolar bone absorption around the implants, overdenture base fracture rate, artificial tooth fall off and fracture rate and other complications. The change of the locator attachment retention force of the implant-supported overdentures was evaluated. SPSS 13.0 software package was used for data analysis. RESULTS: During the five-years clinical observation period, 5 implants fell off, 1 narrow dimeter implant in the anterior zone was broken, and 12 implants were lost to follow-up. The implant survival rate was 97.25%. One year after the restoration therapy finished, peri-implant mucosal bleeding on probing (BOP+) was detected in 48 (21.4%) implants. The average BI was 0.21±0.42, which was higher in the anterior zone than that in the posterior zone. The vertical alveolar bone absorption height around the implants was (0.21±0.35) mm, 2 implants-supported complete overdenture bases were broken. After 5 years of restoration, 163(76.89%) implants had peri-implant mucosal bleeding on probing(BOP+). The average BI was 1.00±0.70, and the vertical alveolar bone absorption height around the implants was (0.58±0.85) mm. There was no significant difference between males and females. There was no significant difference in the peri-implant mucosal bleeding index and the alveolar bone vertical absorption height between the anterior zone and the posterior zone(P>0.05). The mean BI of peri-implant mucosa and the vertical absorption height of peri-implant alveolar bone were significantly different between the 1-year observation period and the 5-year observation period respectively(P<0.01). There were 17(26.15%) cases with overdenture bases fracture, and the fracture rate of artificial teeth was 16.92%. Most of them occurred in the midline area of the anterior zone and the location of the overdenture base on the locator attachments. The average first replacement time of the locator attachment nylon retainer washer was 34.2±10.3 months. CONCLUSIONS: Implants retained complete overdentures with Locator attachments are effective in long term clinical observation. Complications are mainly found in peri-implant mucosal bleeding on probing and vertical alveolar bone absorption, and tended to increase gradually over time. The fracture of the implant retains complete overdenture bases and the fall off or fracture of the artificial teeth are the second serious complications. Overdenture base with metal frame at the location of the Locator abutment and the midline of the anterior area should be strengthened, and narrow diameter implants should be avoided as far as possible in the anterior zone.


Assuntos
Implantes Dentários , Arcada Edêntula , Masculino , Feminino , Humanos , Revestimento de Dentadura , Prótese Dentária Fixada por Implante/efeitos adversos , Retenção de Dentadura , Mandíbula/cirurgia , Implantes Dentários/efeitos adversos
6.
Trials ; 25(1): 267, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627819

RESUMO

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Idoso , Pessoa de Meia-Idade , Revestimento de Dentadura , Fluxo de Trabalho , Mandíbula/cirurgia , Satisfação do Paciente , Impressão Tridimensional , Prótese Dentária Fixada por Implante , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Int J Prosthodont ; 37(2): 153-156, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38648163

RESUMO

PURPOSE: To assess the effectiveness of converting a conventional mandibular denture (CMD) into a single-implant mandibular overdenture (SIMO). MATERIALS AND METHODS: Edentulous patients received a new CMD and were randomly assigned to the CMD or SIMO group. For SIMO patients, a midline early-loaded implant was inserted and incorporated into the CMD after 3 weeks. Patient satisfaction and oral health-related quality of life were assessed at baseline and up to 1 year. Regression models were constructed using Generalized Estimating Equation (GEE). RESULTS: After 12 months, 32 patients were assessed (CMD: n = 17; SIMO: n = 15). Significant improvement was observed for the SIMO group compared to baseline measures. CONCLUSIONS: SIMO may be considered an effective alternative for patients unsatisfied with their CMDs.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Total Inferior , Revestimento de Dentadura , Satisfação do Paciente , Qualidade de Vida , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Arcada Edêntula/reabilitação , Mandíbula , Carga Imediata em Implante Dentário
8.
J Prosthet Dent ; 131(5): 917.e1-917.e13, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38443244

RESUMO

STATEMENT OF PROBLEM: A consensus on the optimal approach to the placement of pterygoid implants is lacking. PURPOSE: The purpose of this finite element analysis study was to determine the optimal approach to the placement of pterygoid implants by comparing biomechanical behavior. MATERIAL AND METHODS: An edentulous and moderately atrophic maxilla with the anatomic structure of the pterygomaxillary region was constructed. Complete arch restorations with 4 standard anterior implants and pterygoid implants in 3 approaches were simulated: L70, long pterygoid implants (4.1×18 mm) inclined at 70 degrees relative to the Frankfort horizontal plane with anchorage in the pterygoid process; L45, long pterygoid implants (4.1×20 mm) inclined at 45 degrees with anchorage in the pterygoid process; and S45, shorter pterygoid implants (4.1×13 mm) inclined 45 degrees without apical anchorage. The L70, L45, and S45 groups were classified as D or S depending on the bone quality: D3 (dense trabecular bone) or D4 (sparse trabecular bone). A total of 6 finite element models were built. The bone failure theory, based on the von Mises theory, was used to judge yielding of the trabecular bone. The von Mises stress (σVM) distribution was measured in the cortical bone, the trabecular bone, and on the implant surface. Deformation (DF) distribution was obtained for the entire bone (DFB) and bone surrounding the pterygoid implant (DFP). RESULTS: L70 showed a lower maximum σVM value (maxσVM), more uniform σVM distribution in the cortical bone, trabecular bone, and on the implant surface and a lower maximum DFp value (maxDFp), especially in the D4 bone. The biomechanical behaviors were similar in L45 and S45 with no stress distribution in the pterygoid process. In the D4 bone, L70, L45, and S45 exceeded the limited stress of the bone failure theory by 50%, 130%, and 130%, while all values were under the limit in D3 bone. CONCLUSIONS: The approach of pterygoid implants inclined at 70 degrees relative to the Frankfort plane with anchorage in the pterygoid process was optimal, providing improved biomechanical behavior. Clinically, in the case of D4 bone, the inclined angulation of pterygoid implants should be 70 degrees to minimize the risk of failure.


Assuntos
Implantes Dentários , Análise de Elementos Finitos , Maxila , Humanos , Maxila/cirurgia , Fenômenos Biomecânicos , Implantação Dentária Endóssea/métodos , Osso Esfenoide/cirurgia , Imageamento Tridimensional/métodos , Análise do Estresse Dentário , Arcada Edêntula/cirurgia
9.
J Prosthet Dent ; 131(5): 904.e1-904.e10, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38472073

RESUMO

STATEMENT OF PROBLEM: Implant placement in the mandibular molar sites plays a crucial role in the restoration of edentulous mandibles. However, the evaluation of bone quantity before implant surgery using cone beam computed tomography (CBCT) is lacking. PURPOSE: The purpose of this clinical study was to evaluate CBCT images of edentulous patients to analyze the feasibility of implant placement in healed mandibular molar sites. MATERIAL AND METHODS: The CBCT data of 138 patients were analyzed in the sagittal plane for measurements of mandibular bone height (MBH), superior bone height (SBH), inferior bone height (IBH), buccal bone width (BBW), lingual bone width (LBW), and alveolar bone widths (ABWs). The edentulous sites were categorized according to the bone quantity and complexity of the implant surgery. Multivariate analysis of variance (MANOVA) was used to analyze the site, sex, and age-related variations. An independent t test was used to compare the difference of bone dimension in different sites and between sexes. One-way ANOVA followed by post hoc tests were used to analyze the difference between different age groups. Categorical variables were presented as number of events and percentages. The chi-squared test was used to compare categorical variables (α=.05). RESULTS: A total of 534 sites of interest were recorded, including 274 hemimandibles. A significant difference in BBW was found between the first and second molar sites. Men had higher MBH, SBH, IBH, and BBW than women. The distribution of implant surgical complexity in the conventional group was 63.5%, while the buccolingual tilted implant group accounted for 17.0%, and the complicated group accounted for 19.5%. Of the 274 hemimandibles, an implant could be placed directly at molar sites in 88% of situations. CONCLUSIONS: The BBW at the mandibular second molar site was greater than that at the first molar site. The amount of available bone in the SBH and BBW was greater in men than in women at the healed molar sites. Age did not significantly affect the complexity of the implant surgery. Implants can be placed directly in healed mandibular molar sites in most patients who require a complete arch mandibular implant-supported restoration.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Estudos de Viabilidade , Mandíbula , Dente Molar , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Masculino , Feminino , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Estudos Retrospectivos , Dente Molar/diagnóstico por imagem , Pessoa de Meia-Idade , Adulto , Idoso , Implantação Dentária Endóssea/métodos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Implantes Dentários
10.
J Dent ; 145: 104979, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38556193

RESUMO

OBJECTIVES: The aim of the present in vitro study was to evaluate the effect of a novel auxiliary geometric device (AGD) on the accuracy of full-arch scans captured with 3 different intraoral scanners (IOS). METHODS: An edentulous maxillary model with four internal connection implant replicas was scanned using 3 different IOS: iTero Element 5D (ITERO) (Align Technology, Tempe, AZ, USA), Trios 4 (TRIOS) (3Shape A/S, Copenhagen, Denmark), and Carestream 3700 (CS) (Carestream Dental, Atlanta, USA). Thirty-six scans were taken with each IOS, 18 with the AGD in place, and 18 without the AGD. A digital master model was created using an industrial optical scanner (ATOS compact Scan 5M, GOM GmbH, Braunschweig, Germany). The master and IOS models were aligned using the scan bodies as a reference area. A surface comparison was performed, and deviation labels were exported for each scan body to evaluate the linear and angular deviation. Total body, platform and angular deviations were measured. RESULTS: The use of AGD resulted in a statistically significant increase of angular deviation: 0.87° (SD=0.21) in the AGD group versus 0.64° (SD=0.46) in the no AGD group (p-value=0.005). The difference between the AGD and no AGD groups was not statistically significant for total body and platform deviation values (p-value=0.051 and 0.302 respectively). Using AGD, ITERO showed a statistically significant increase in angular deviation (mean difference=-0.46 µm, p-value=0.002) and a decrease in mean platform deviation (mean difference=63.19 µm, p-value<0.001). No statistically significant differences were found for the other IOS. CONCLUSIONS: The use of AGD did not add benefit on CS and TRIOS. On ITERO, there was an improvement in platform deviation, that was outweighed by the worsening of the angular deviation. CLINICAL SIGNIFICANCE: In vitro data suggest that intraoral scans can be successfully used in full-arch cases. The use of AGD has no additional benefit on CS and TRIOS. On ITERO there was an improvement in platform deviation that was outweighed by the worsening of the angular deviation. Translational application to clinical practice deserves further investigation, taking into account patient-related and anatomical variables.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Modelos Dentários , Humanos , Maxila/diagnóstico por imagem , Desenho Assistido por Computador , Imageamento Tridimensional/métodos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/reabilitação , Técnicas In Vitro , Arco Dental/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Planejamento de Prótese Dentária
11.
Int J Implant Dent ; 10(1): 12, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480586

RESUMO

PURPOSE: The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible. METHODS: From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up. RESULT: A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22). CONCLUSIONS: A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Seguimentos , Estudos Prospectivos , Revestimento de Dentadura , Qualidade de Vida , Arcada Edêntula/cirurgia , Mandíbula/cirurgia
12.
J Contemp Dent Pract ; 25(2): 141-147, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514411

RESUMO

AIM: To compare between the rehabilitation of atrophied maxilla with fixed prosthesis using two posterior zygomatic implants and two conventional anterior implants or four implants inserted according to the all-on-four concept regarding the patient quality of life and satisfaction after one year of prosthesis insertion. MATERIALS AND METHODS: Thirty-six patients with atrophic edentulous maxillae were randomized into two groups: Group I (rehabilitated with fixed prostheses supported by two zygomatic and two conventional implants in the anterior region) and group II (fixed prostheses on four implants in the anterior region following an all-on-four concept). One year after the placement of the definitive prostheses, patients completed oral health impact profile-14 and satisfaction questionnaires. RESULTS: All patients were satisfied regarding retention, stability, occlusion, comfort, cleaning, speaking, chewing, bolus quality, appearance, handling, prosthesis apart, and embarrassing, with no significant significance between two groups except satisfaction with surgical procedures and healing period. CONCLUSIONS: Using two distally tilted zygomatic implants or all-on-four concept to rehabilitate atrophied maxilla by fixed detachable prosthesis could be considered a promising functional and esthetic treatment option regarding the patient satisfaction. CLINICAL SIGNIFICANCE: Traditionally, treatment of maxillary atrophied ridges was done by bone grafting or sinus-lifting techniques; however, using all-on-four concept or zygomatic implants was a successful treatment as it has high success rates and highly satisfied by the patients. How to cite this article: Nagib MA, Ibrahim AM, Abdel-Rahman FH, et al. Evaluation of Quality of Life and Satisfaction with Fixed Prostheses on Zygomatic Implants vs All-on-Four Concept: A Randomized Clinical Study. J Contemp Dent Pract 2024;25(2):141-147.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Qualidade de Vida , Estética Dentária , Satisfação do Paciente , Prótese Dentária Fixada por Implante , Maxila/cirurgia , Implantação Dentária Endóssea/métodos , Arcada Edêntula/cirurgia , Arcada Edêntula/reabilitação , Seguimentos , Resultado do Tratamento
13.
J Oral Implantol ; 50(2): 104-110, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38353347

RESUMO

Accuracy is a necessity in implant impressions to fabricate accurately fitting implant-supported prostheses. This in vitro study aimed to explore the impact of the number of scan bodies on scanning quality by comparing scans of 2 vs 4 implants, and to determine if their accuracy and precision meets acceptable clinical threshold. Two mandibular edentulous models were used: one with 4-parallel implants (4-IM) and the other with 2-parallel implants (2-IM). Each model was scanned 10 times with an intraoral scanner, while reference scans were obtained with a high-precision laboratory scanner. The accuracy of test scans was evaluated by superimposing them onto reference scans and measuring 3D and angular deviations of the scan bodies. To assess the precision, the repeatability of the scans was analyzed by measuring the 3D SDs. Independent t test was used to compare angular deviations, the Mann-Whitney U test was used for 3D deviations and 3D SDs, and 1 sample t test was used for comparing means to the clinical threshold. Angular and 3D deviations were statistically not significant between the 2 groups (P = .054 and 0.143). 3D deviation values were higher than the 150-µm threshold for 2-IM (201 µm) and 4-IM (290 µm); angular deviation in 2-IM was 0.600 degrees and 0.885 degrees for 4-IM. There was no statistically significant difference in the precision of scans between the 2 groups. (P = .161). Although scanning quality improved when 2 scan bodies were used, the difference was not statistically significant. Moreover, full-arch implant scanning did not meet acceptable levels of accuracy and precision.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Humanos , Prótese Dentária Fixada por Implante , Mandíbula/diagnóstico por imagem , Imageamento Tridimensional , Técnicas In Vitro , Desenho Assistido por Computador , Arcada Edêntula/diagnóstico por imagem , Planejamento de Prótese Dentária , Modelos Dentários
14.
Clin Oral Implants Res ; 35(5): 560-572, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38421115

RESUMO

OBJECTIVES: The purpose of this in vitro study was to compare the trueness and precision of complete arch implant impressions using conventional impression, intraoral scanning with and without splinting, and stereophotogrammetry. MATERIALS AND METHODS: An edentulous model with six implants was used in this study. Four implant impression techniques were compared: the conventional impression (CI), intraoral scanning (IOS) without splinting, intraoral scanning with splinting (MIOS), and stereophotogrammetry (SPG). An industrial blue light scanner was used to generate the baseline scan from the model. The CI was captured with a laboratory scanner. The reference best-fit method was then applied in the computer-aided design (CAD) software to compute the three-dimensional, angular, and linear discrepancies among the four impression techniques. The root mean square (RMS) 3D discrepancies in trueness and precision between the four impression groups were analyzed with a Kruskal-Wallis test. Trueness and precision between single analogs were assessed using generalized estimating equations. RESULTS: Significant differences in the overall trueness (p = .017) and precision (p < .001) were observed across four impression groups. The SPG group exhibited significantly smaller RMS 3D deviations than the CI, IOS, and MIOS groups (p < .05), with no significant difference detected among the latter three groups (p > .05). CONCLUSIONS: Stereophotogrammetry showed superior trueness and precision, meeting misfit thresholds for implant-supported complete arch prostheses. Intraoral scanning, while accurate like conventional impressions, exhibited cross-arch angular and linear deviations. Adding a splint to the scan body did not improve intraoral scanning accuracy.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Fotogrametria , Fotogrametria/métodos , Humanos , Técnicas In Vitro , Modelos Dentários , Imageamento Tridimensional/métodos , Arcada Edêntula/diagnóstico por imagem , Implantes Dentários , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Planejamento de Prótese Dentária
15.
Esophagus ; 21(2): 120-130, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38376617

RESUMO

BACKGROUND: Poor oral health is an independent risk factor for upper-aerodigestive tract cancers, including esophageal cancer. Several studies have investigated short-term outcomes after esophagectomy and the impact of periodontal disease, but few have examined the impact of periodontal disease on long-term outcomes. The purpose of this study was to investigate the rate of periodontitis among esophagectomy patients and the prognostic value of periodontitis and its effect on prognosis after esophagectomy. METHODS: A total of 508 patients who underwent esophagectomy received oral health care from a dentist before cancer treatment at Akita University Hospital between January 2009 and December 2021. We assessed the presence and severity of the patients' periodontitis and divided them into no-periodontitis, mild periodontitis, severe periodontitis and edentulous jaw groups. We then assessed 10-year overall survival (OS) and disease-specific survival (DSS) and determined whether periodontitis was an independent prognostic factor affecting OS and DSS. RESULTS: We found that 101 (19.9%) patients had no periodontitis, 207 (40.8%) had mild periodontitis, 176 (34.6%) had severe periodontitis requiring tooth extraction, and 24 (4.7%) had edentulous jaw. Both OS and DSS were significantly poorer in the periodontitis than no-periodontitis group (p < 0.001). In detail, the edentulous jaw group had the poorest prognosis (p < 0.001). Multivariate analysis showed that periodontitis was an independent risk factor affecting OS and DSS. CONCLUSION: Esophageal cancer patients had a high prevalence of periodontitis. Moreover, the presence of periodontitis and severity of periodontitis are independent risk factors contributing to a poorer prognosis after esophagectomy.


Assuntos
Neoplasias Esofágicas , Arcada Edêntula , Periodontite , Humanos , Esofagectomia/efeitos adversos , Estadiamento de Neoplasias , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/cirurgia , Prognóstico , Periodontite/complicações , Periodontite/epidemiologia , Periodontite/cirurgia , Arcada Edêntula/cirurgia
16.
Clin Oral Investig ; 28(3): 160, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38378935

RESUMO

OBJECTIVES: Single denture rehabilitated patients have negative appraisals regarding oral function, mostly associated by stability and retention issues regarding mandibular prosthetics. Therefore, this study assessed patients' occlusal equilibration, muscle activity, and oral health-related quality of life (OHRQoL) receiving milled removable or fixed mandibular implant retained prostheses. MATERIALS AND METHODS: Twenty-two edentulous mandibular ridges patients were randomly distributed into two groups based on the definitive prosthesis received. Group I: Removable mandibular implant-supported overdenture, Group II: Implant retained fixed prosthesis. Occlusal equilibration was evaluated utilizing Occlusense, muscle activity via Electromyograph (EMG) at delivery, after one, and three months. The OHRQoL was evaluated by Oral Health Impact Profile questionnaire (OHIP-19) before delivery and after follow-ups. Data were collected, tabulated, and analyzed, utilizing independent t-test and One-way ANOVA followed Tukey`s post-hoc test. Significance level set at P ≤ 0.05. RESULTS: Groups I &II showed significant improvement in occlusal equilibration, muscle activity and OHRQoL. Group II demonstrated significantly higher improvement than group I in occlusal equilibration associated with muscle activity after 1 month, and in functional limitations domain in OHRQoL questionnaire after 3 months. CONCLUSION: Implant retained mandibular prosthesis showed improvement in occlusal equilibration, muscle activity, and OHRQoL regardless of prosthesis type employed. Fixed implant-supported prosthesis revealed better outcomes than removable mandibular implant-supported overdenture concerning occlusal equilibration, muscle activity, and OHRQoL regarding functional limitations. CLINICAL RELEVANCE: Implant retained mandibular prosthesis is one of best treatment options for single mandibular completely edentulous patients, as dental implants improved occlusal equilibration, muscle activity, and OHRQoL.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Mandíbula , Músculos , Ajuste Oclusal , Satisfação do Paciente , Qualidade de Vida
17.
J Dent ; 143: 104885, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38346663

RESUMO

OBJECTIVES: This article presents a novel complete-arch pillar system (CAPS) to register implant position and maxillomandibular relationship in one single visit for implant-supported fixed complete dental prostheses (IFCDPs). MATERIAL AND METHODS: The novel system presents a 3-unit toolset comprising intraoral scan bodies (ISBs), lateral pillar attachments (LPAs) and occlusal pillar attachments (OPAs). A 2-stage single visit workflow by an intraoral scanner (Trios 5) was introduced. The first stage "Screw-Scan-Done" was used to describe complete-arch intraoral implant scanning using LPAs. The second stage "Screw-Occlude-Done" involved virtual occlusal recording using OPAs. Two patients with one single edentulous arch were selected for this study. In the first patient, 6 bone level implants (Bone Level Tapered, Straumann) were placed in the edentulous maxilla at positions 12, 14, 16, 22, 24 and 26. In the second patient, 4 bone level implants (NobelActive CC, Nobel Biocare) were placed in the edentulous mandible at positions 32, 35, 42 and 45. A CAD-CAM procedure was initiated with the acquired IOS data to fabricate an interim IFCDP at the same day. Periapical radiographs were obtained of the implant-prosthetic connection of the definitive IFCDPs to verify the passive fit. Metrology software (Geomagic Qualify, 3D Systems - Matlab, Mathworks) was used to assess the implant analogs position in the 3D-printed casts used for fabricating the definitive IFCDPs. A quantitative occlusal relationship analysis was performed with IOS. RESULTS: Radiographic examination revealed no gaps at implant-prosthetic connection of the definitive IFCDPs. The 3D-printed casts showed an overall average distance deviation within the clinically acceptable range of errors of 150 µm. Quantitative occlusal relationship analysis with IOS showed well-distributed contacts. CONCLUSION: Within the limitations of this study, the following conclusions can be drawn: (1) A 3-unit toolset with ISBs, LPAs and OPAs allows to register the implant position and maxillomandibular relationship in one single visit; (2) the 2-stage clinical workflow with the CAPS system facilitates the IOS data acquisition for fabrication of an interim IFCDP at the same day; (3) a passive fit was demonstrated for the interim and the definitive IFCDPs. CLINICAL SIGNIFICANCE: The CAPS system can help clinicians to register the implant position and the maxillomandibular relationship in one single visit for the fabrication of an IFCDP.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/cirurgia , Imageamento Tridimensional , Técnica de Moldagem Odontológica
18.
J Long Term Eff Med Implants ; 34(2): 9-15, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38305366

RESUMO

Immediate function has become an accepted treatment modality for fixed restorations in completely edentulous jaws. The dental implants have gained immense popularity. A secure implant primary stability is positively associated with a successful implant integration and long term successful clinical outcome. The main aim of this study was to find the association between primary stability and bone density in implants placed in maxilla and mandible. A total of 1263 patients who had undergone implant placement from March 2020-March 2021 in Saveetha Dental College and Hospitals, Chennai, India were chosen for the study. The primary stability and bone density of these patients were collected from the hospital records. The collected data was compiled, reviewed, tabulated in Microsoft Excel sheet and entered in SPSS software for statistical analysis. In the present study, the patient aged between 28 and 37 years had undergone more implant placement (31%) with male predilection (53%). The most commonly associated primary stability was found to be 30-40 Ncm (51.37%) predominantly with D2 type of bone density (52.69%). A Chi-squared statistical test was done for primary stability and bone density and the P was found to be 0.00 (Chi-squared P < 0.05, statistically significant). The most predominant bone density was D2 associated with primary stability of 30-40 Ncm. The association between bone density and primary stability was found to be statistically significant. The present study shows a strong relationship between bone density and primary implant stability.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Masculino , Adulto , Estudos Retrospectivos , Prevalência , Arco Dental , Índia/epidemiologia , Arcada Edêntula/cirurgia , Mandíbula/cirurgia , Implantação Dentária Endóssea , Resultado do Tratamento , Planejamento de Prótese Dentária , Seguimentos
19.
BMC Oral Health ; 24(1): 138, 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38281916

RESUMO

Different characteristics of bars (cross-sectional shape, diameter, distal extension etc.) lead to different biomechanical behavior (retention and stress) with implants and peri-implant tissues.Aim: To evaluate the impact of implant-supported removable prostheses bar designs in fully edentulous arch (in the maxilla and/or mandibula), with 4 implants or more, on the peri-implant soft and hard tissues.Two reviewers searched for observational studies, RCT and in vitro studies, published on five main databases and three from the grey literature, without restrictions on November 2023.Of the 3049 selected articles, four met the inclusion criteria. Four RCT evaluated peri-implant health tissues in full edentulous arches with 4 or 6 implants rehabilitated with implant bar overdentures. One prospective study with 5 years follow-up evaluated the success/survival rate of implants and implant bar overdentures. Overall, 261 subjects were enrolled in our systematic review with 1176 implants. Overdentures' survival rate was 100%. There was a trend that plaque indices and gingival indices were low in all of the studies, however no statistical analysis was done due to the lack of information.Due to the lack of information in the included studies, we cannot confirm if bar characteristics affect the peri-implant tissues health.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Estudos Prospectivos , Prótese Dentária Fixada por Implante , Mandíbula , Revestimento de Dentadura , Retenção de Dentadura
20.
BMC Oral Health ; 24(1): 134, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38279099

RESUMO

The aim of the present study was to analyze and compare the angle deviation of two, four and six adjacent dental implants placed with and without straight parallel pins. MATERIALS AND METHODS: Two hundred and forty (240) dental implants were selected and randomly allocated into the following study groups: Two dental implants placed with straight parallel pins (Ref.: 144-100, BioHorizons, Birmingham, AL, USA) (n = 10) (2PP); Two dental implants placed without parallel pins (n = 10) (2withoutPP); Four dental implants placed with straight parallel pins hT(n = 10) (4PP); Four dental implants placed without parallel pins (n = 10) (4withoutPP); Six dental implants placed with straight parallel pins (n = 10) (6PP) and Six dental implants placed without parallel pins (n = 10) (6withoutPP). The dental implants randomly assigned to groups 2PP and 2withoutPP were placed into standardized polyurethane models of partially edentulous upper jaws in tooth positions 2.4 and 2.6, the dental implants randomly assigned to groups 4PP and 4withoutPP were placed into standardized polyurethane models of fully edentulous upper jaws in tooth positions 1.6, 1.4, 2.4 and 2.6, and the dental implants randomly assigned to groups 6PP and 6withoutPP were placed into standardized polyurethane models of fully edentulous upper jaws in tooth positions 1.6, 1.4, 1.2, 2.2, 2.4 and 2.6. Afterwards, postoperative CBCT scans and digital impressions were aligned in a 3D implant-planning software to compare the angle deviation (°) of two, four and six adjacent dental implants placed with and without straight parallel pins using the General Linear Model statistical analysis. RESULTS: Statistically significant differences were found between the angle deviation of 2 dental implants placed with straight parallel pins (p < 0.0001) and between the angle deviation of 4 dental implants placed with straight parallel pins (p = 0.0024); however, no statistically significant differences were found in the angle deviation of 6 dental implants placed with straight parallel pins (p = 0.9967). CONCLUSION: The use of a straight parallelization pin results in lower angle deviation between two and four adjacent dental implants; however, it is not effective for a larger number of dental implants.


Assuntos
Implantes Dentários , Arcada Edêntula , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea/métodos , Poliuretanos , Cirurgia Assistida por Computador/métodos , Imageamento Tridimensional , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...