Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.921
Filtrar
1.
Carbohydr Polym ; 339: 122288, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38823936

RESUMO

This paper reports on biofunctionalisation of a poly(lactic acid) (PLA) film by surface activation through cold plasma treatment followed by coating with a chitosan-gelatin xerogel. The UV cross-linking of the xerogel precursor was simultaneously performed with the fixation onto the PLA support. This has a strong effect on surface properties, in terms of wettability, surface free energy, morphology and micromechanical features. The hydrophilic - hydrophobic character of the surface, determined by contact angle measurements, was tuned along the process, passing from moderate hydrophobic PLA to enhanced hydrophilic plasma activated surface, which favors coating adhesion, then to moderate hydrophobic chitosan-gelatin coating. The coating has a Lewis amphoteric surface, with a porous xerogel-like morphology, as revealed by scanning electron microscopy images. By riboflavin mediated UV cross-linking the chitosan-gelatin coating becomes high adhesive and with a more pronounced plasticity, as shown by AFM force-distance spectroscopy. Thus prepared surface-coated PLA supports were successfully tested for growth of dermal fibroblasts, which are known for their induction potential of chondrogenic cells, which is very important in cartilage tissue engineering.


Assuntos
Quitosana , Fibroblastos , Gelatina , Poliésteres , Quitosana/química , Gelatina/química , Poliésteres/química , Fibroblastos/efeitos dos fármacos , Fibroblastos/citologia , Humanos , Propriedades de Superfície , Géis/química , Raios Ultravioleta , Gases em Plasma/química , Interações Hidrofóbicas e Hidrofílicas , Materiais Revestidos Biocompatíveis/química , Reagentes de Ligações Cruzadas/química , Molhabilidade
2.
Biointerphases ; 19(3)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38836787

RESUMO

Titanium (Ti) is widely utilized as an implant material; nonetheless, its integration with bone tissue faces limitations due to a patient's comorbidities. To address this challenge, we employed a strategic approach involving the growth of thin films by spin-coating and surface functionalization with etidronate (ETI), alendronate (ALE), and risedronate (RIS). Our methodology involved coating of Ti cp IV disks with thin films of TiO2, hydroxyapatite (HA), and their combinations (1:1 and 1:2 v/v), followed by surface functionalization with ETI, ALE, and RIS. Bisphosphonate-doped films were evaluated in terms of surface morphology and physical-chemical properties by techniques such as electron microscopy, confocal microscopy, and x-ray photoelectron spectroscopy. The antibacterial potential of bisphosphonates alone or functionalized onto the Ti surface was tested against Staphylococcus aureus biofilms. Primary human bone mesenchymal stem cells were used to determine in vitro cell metabolism and mineralization. Although RIS alone did not demonstrate any antibacterial effect as verified by minimum inhibitory concentration assay, when Ti surfaces were functionalized with RIS, partial inhibition of Staphylococcus aureus growth was noted, probably because of the physical-chemical surface properties. Furthermore, samples comprising TiO2/HA (1:1 and 1:2 v/v) showcased an enhancement in the metabolism of nondifferentiated cells and can potentially enhance the differentiation of osteoblastic precursors. All samples demonstrated cell viability higher than 80%. Addition of hydroxyapatite and presence of bisphosphonates increase the metabolic activity and the mineralization of human bone mesenchymal cells. While these findings hold promise, it is necessary to conduct further studies to evaluate the system's performance in vivo and ensure its long-term safety. This research marks a significant stride toward optimizing the efficacy of titanium implants through tailored surface modifications.


Assuntos
Antibacterianos , Difosfonatos , Células-Tronco Mesenquimais , Testes de Sensibilidade Microbiana , Staphylococcus aureus , Propriedades de Superfície , Titânio , Titânio/química , Titânio/farmacologia , Humanos , Antibacterianos/farmacologia , Antibacterianos/química , Staphylococcus aureus/efeitos dos fármacos , Difosfonatos/química , Difosfonatos/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Células Cultivadas , Durapatita/química , Durapatita/farmacologia
3.
Med Sci Monit ; 30: e944255, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38843112

RESUMO

Orthodontic treatments, while essential for achieving optimal oral health, present challenges in infection control due to the propensity for bacterial adhesion and biofilm formation on orthodontic appliances. Silver-coated orthodontic materials have emerged as a promising solution, leveraging the potent antimicrobial properties of silver nanoparticles (AgNPs). Antibacterial coatings are used in orthodontics to prevent the formation of bacterial biofilms. This systematic review evaluated the literature on antimicrobial silver coatings on fixed orthodontic appliances, including archwires, brackets, and microimplants. Two evaluators, working independently, rigorously conducted a comprehensive search of various databases, including PubMed, PubMed Central, Embase, Scopus and Web of Science. This systematic review comprehensively examined in vitro studies investigating the antimicrobial efficacy of silver-coated orthodontic archwires, brackets, and microimplants. The review registered in PROSPERO CRD42024509189 synthesized findings from 18 diverse studies, revealing consistent and significant reductions in bacterial adhesion, biofilm formation, and colony counts with the incorporation of AgNPs. Key studies demonstrated the effectiveness of silver-coated archwires and brackets against common oral bacteria, such as Streptococcus mutans and Staphylococcus aureus. Microimplants coated with AgNPs also exhibited notable antimicrobial activity against a range of microorganisms. The systematic review revealed potential mechanisms underlying these antimicrobial effects, highlighted implications for infection prevention in orthodontic practice, and suggested future research avenues. Despite some study heterogeneity and limitations, the collective evidence supports the potential of silver-coated orthodontic materials in mitigating bacterial complications, emphasizing their relevance in advancing infection control measures in orthodontics.


Assuntos
Biofilmes , Nanopartículas Metálicas , Braquetes Ortodônticos , Prata , Prata/farmacologia , Humanos , Biofilmes/efeitos dos fármacos , Braquetes Ortodônticos/microbiologia , Fios Ortodônticos/microbiologia , Aparelhos Ortodônticos Fixos , Anti-Infecciosos/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Antibacterianos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Aderência Bacteriana/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos
4.
PLoS One ; 19(6): e0301618, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38843277

RESUMO

Periprosthetic tissue inflammation is a challenging complication arising in joint replacement surgeries, which is often caused by wear debris from polyethylene (PE) components. In this study, we examined the potential biological effects of grafting a [2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide (MEDSAH) polymer onto the surface of PE through a solvent-evaporation technique. J774A.1 macrophage-like cells and primary cultured mouse osteoblasts were treated with PE powder with or without the MEDSAH coating. MEDSAH grafting on PE substantially reduced the expression of pro-inflammatory cytokines and other mediators in primary cultured mouse osteoblasts, but did not significantly impact macrophage-mediated inflammation. Our findings suggest that a MEDSAH coating on PE-based materials has potential utility in mitigating periprosthetic tissue inflammation and osteolysis and preventing aseptic loosening in total joint replacements. Further research, including large-scale clinical trials and biomechanical analyses, is needed to assess the long-term performance and clinical implications of MEDSAH-coated PE-based materials in total joint arthroplasty.


Assuntos
Inflamação , Osteoblastos , Polietileno , Animais , Camundongos , Inflamação/patologia , Osteoblastos/metabolismo , Osteoblastos/efeitos dos fármacos , Macrófagos/metabolismo , Linhagem Celular , Citocinas/metabolismo , Osteólise/etiologia , Osteólise/patologia , Materiais Revestidos Biocompatíveis/química , Metacrilatos/química , Artroplastia de Substituição/efeitos adversos
5.
Int J Implant Dent ; 10(1): 29, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839621

RESUMO

PURPOSE: This study evaluated the implant stability, volumetric changes, and patient-reported outcome measures (PROMs) of hydroxyapatite (HA) nano-coated sandblasted/acid-etched (SLA) implants compared to uncoated SLA implants. METHODS: Forty patients were recruited and randomly allocated to HA nano-coated SLA group (test, n = 20) and uncoated SLA group (control, n = 20) using single-blinded/block randomization. Implants were immediately placed in maxillary posterior region using a digital surgical guide. Insertion torque and implant stability quotient (ISQ) were measured at implant surgery and 1, 2, 3, and 4 months postoperatively. Intraoral scans, PROMs and soft tissue inflammation data were collected, and multivariable linear regression analysis of ISQ was performed. RESULTS: In total, 48 implants (test; n = 24, control; n = 24) in 37 patients (test; n = 19, control; n = 18) were analyzed. Despite no significant between-group difference at surgery, the test group showed higher ISQ values than the control group at 2 (76.53 ± 4.17 vs. 71.32 ± 4.79, p < 0.01), 3 (77.45 ± 4.41 vs. 73.85 ± 4.69, p < 0.05), and 4 months (79.08 ± 2.96 vs. 73.43 ± 3.52, p < 0.0001) postoperatively. There were no significant differences in linear and volumetric changes, PROMs, and soft tissue inflammation analysis between two groups. The ISQ at implant surgery was influenced by age and diabetes mellitus (DM) at the implant level and DM and predicted total bone-to-implant contact area at the patient level. CONCLUSION: HA nano-coated SLA implants promoted favorable immediate implants stability during early osseointegration phase compared to uncoated SLA implants, but displayed similar dimensional changes, PROMs, and soft tissue inflammation outcomes. TRIAL REGISTRATION: Clinical Research Information Service (CRIS), KCT0006364. Registered 21 July 2021, https://cris.nih.go.kr/cris/search/detailSearch.do?seq=24221&search_page=L .


Assuntos
Durapatita , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Método Simples-Cego , Implantes Dentários , Carga Imediata em Implante Dentário/métodos , Adulto , Materiais Revestidos Biocompatíveis/química , Condicionamento Ácido do Dente , Idoso , Medidas de Resultados Relatados pelo Paciente , Osseointegração , Propriedades de Superfície
6.
Int J Nanomedicine ; 19: 5011-5020, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38832337

RESUMO

Purpose: Atomic layer deposition (ALD) is a method that can deposit zirconia uniformly on an atomic basis. The effect of deposited zirconia on titanium implants using ALD was evaluated in vivo. Methods: Machined titanium implants (MTIs) were used as the Control. MTIs treated by sandblasting with large grit and acid etching (SA) and MTIs deposited with zirconia using ALD are referred to as Groups S and Z, respectively. Twelve implants were prepared for each group. Six rabbits were used as experimental animals. To evaluate the osteogenesis and osteocyte aspects around the implants, radiological and histological analyses were performed. The bone-to-implant contact (BIC) ratio was measured and statistically analyzed to evaluate the osseointegration capabilities. Results: In the micro-CT analysis, more radiopaque bone tissues were observed around the implants in Groups S and Z. Histological observation found that Groups S and Z had more and denser mature bone tissues around the implants in the cortical bone area. Many new and mature bone tissues were also observed in the medullary cavity area. For the BIC ratio, Groups S and Z were significantly higher than the Control in the cortical bone area (P < 0.017), but there was no significant difference between Groups S and Z. Conclusion: MTIs deposited with zirconia using ALD (Group Z) radiologically and histologically showed more mature bone formation and activated osteocytes compared with MTIs (Control). Group Z also had a significantly higher BIC ratio than the Control. Within the limitations of this study, depositing zirconia on the surface of MTIs using ALD can improve osseointegration in vivo.


Assuntos
Osseointegração , Titânio , Zircônio , Animais , Zircônio/química , Zircônio/farmacologia , Coelhos , Titânio/química , Titânio/farmacologia , Osseointegração/efeitos dos fármacos , Propriedades de Superfície , Microtomografia por Raio-X , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Interface Osso-Implante , Osteogênese/efeitos dos fármacos , Implantes Dentários , Próteses e Implantes
7.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38725023

RESUMO

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Assuntos
Espectroscopia Dielétrica , Teste de Materiais , Fios Ortodônticos , Saliva Artificial , Aço Inoxidável , Zinco , Corrosão , Aço Inoxidável/química , Zinco/química , Saliva Artificial/química , Ligas Dentárias/química , Materiais Revestidos Biocompatíveis/química , Fluoretos/química , Concentração de Íons de Hidrogênio , Humanos , Propriedades de Superfície , Potenciometria
8.
Int J Nanomedicine ; 19: 4515-4531, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803996

RESUMO

Introduction: There is an ongoing need for improved healing response and expedited osseointegration on the Ti implants in acetabular fracture sites. To achieve adequate bonding and mechanical stability between the implant surface and the acetabular fracture, a new coating technology must be developed to promote bone integration and prevent bacterial growth. Methods: A cylindrical Ti substrate mounted on a rotating specimen holder was used to implant Ca2+, P2+, and Sr2+ ions at energies of 100 KeV, 75 KeV and 180 KeV, respectively, using a low-energy accelerator to synthesize strontium-substituted hydroxyapatite at varying conditions. Ag2+ ions of energy 100 KeV were subsequently implanted on the as-formed surface at the near-surface region to provide anti-bacterial properties to the as-formed specimen. Results: The properties of the as-formed ion-implanted specimen were compared with the SrHA-Ag synthesized specimens by cathodic deposition and low-temperature high-speed collision technique. The adhesion strength of the ion-implanted specimen was 43 ± 2.3 MPa, which is well above the ASTM standard for Ca-P coating on Ti. Live/dead cell analysis showed higher osteoblast activity on the ion-implanted specimen than the other two. Ag in the SrHA implanted Ti by ion implantation process showed superior antibacterial activity. Discussion: In the ion implantation technique, nano-topography patterned surfaces are not concealed after implantation, and their efficacy in interacting with the osteoblasts is retained. Although all three studies examined the antibacterial effects of Ag2+ ions and the ability to promote bone tissue formation by MC3T3-E1 cells on SrHA-Ag/Ti surfaces, ion implantation techniques demonstrated superior ability. The synthesized specimen can be used as an effective implant in acetabular fracture sites based on their mechanical and biological properties.


Assuntos
Acetábulo , Antibacterianos , Prata , Estrôncio , Titânio , Titânio/química , Titânio/farmacologia , Prata/química , Prata/farmacologia , Estrôncio/química , Estrôncio/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Acetábulo/lesões , Animais , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Osseointegração/efeitos dos fármacos , Camundongos , Propriedades de Superfície , Fraturas Ósseas/terapia , Durapatita/química , Durapatita/farmacologia , Osteoblastos/efeitos dos fármacos , Hidroxiapatitas/química , Hidroxiapatitas/farmacologia , Próteses e Implantes , Íons/química , Íons/farmacologia , Humanos , Linhagem Celular
9.
JACC Cardiovasc Interv ; 17(9): 1134-1144, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38749594

RESUMO

BACKGROUND: Limited comparative data exist on different interventional strategies for endovascular revascularization of complex femoropopliteal interventions. OBJECTIVES: In this study, the authors aimed to compare a stent-avoiding (SA) vs a stent-preferred (SP) strategy, promoting optimal lesion preparation and the use of drug-eluting technologies in both arms. METHODS: Within a prospective, multicenter, pilot study, 120 patients with symptomatic complex femoropopliteal lesions (Rutherford classification 2-4, mean lesion length 187.7 ± 78.3 mm, 79.2% total occlusions) were randomly assigned in a 1:1 fashion to endovascular treatment with either paclitaxel-coated balloons or polymer-coated, paclitaxel-eluting stents. Lesion preparation including the use of devices for plaque modification and/or removal was at the operators' discretion in both treatment arms. RESULTS: In the SA group, lesion preparation was more frequently performed (71.7% SA [43/60] vs 51.7% [31/60] SP; P = 0.038) with a high provisional stenting rate (48.3% [29/60]). At the 12-month follow-up, primary patency was 78.2% (43/55) in the SA group and 78.6% (44/56) in the SP group (P = 1.0; relative risk: 0.995; 95% CI: 0.818-1.210). Freedom from major adverse events was determined in 93.1% (54/58) in the SA group and in 94.9% (56/59) in the SP group (P = 0.717; relative risk: 0.981; 95% CI: 0.895-1.075), with all adverse events attributable to clinically driven target lesion revascularization. CONCLUSIONS: Both endovascular strategies promoting lesion preparation before the use of drug-eluting devices suggest promising efficacy and safety results in complex femoropopliteal procedures with a high proportion of total occlusions through 12 months. Ongoing follow-up will show whether different results emerge over time. (Best Endovascular Strategy for Complex Lesions of the Superficial Femoral Artery [BEST-SFA]; NCT03776799).


Assuntos
Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Artéria Femoral , Paclitaxel , Doença Arterial Periférica , Artéria Poplítea , Desenho de Prótese , Grau de Desobstrução Vascular , Humanos , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Masculino , Feminino , Idoso , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Paclitaxel/administração & dosagem , Fatores de Tempo , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Projetos Piloto , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Fatores de Risco , Idoso de 80 Anos ou mais , Dispositivos de Acesso Vascular
11.
Eur Rev Med Pharmacol Sci ; 28(9): 3391-3402, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766802

RESUMO

OBJECTIVE: Although pure titanium (PT) and its alloys exhibit excellent mechanical properties, they lack biological activity as implants. The purpose of this study was to improve the biological activity of titanium implants through surface modification. MATERIALS AND METHODS: Titanium was processed into titanium discs, where the titanium discs served as anodes and stainless steel served as cathodes, and a copper- and cobalt-doped porous coating [pure titanium model (PTM)] was prepared on the surface of titanium via plasma electrolytic oxidation. The surface characteristics of the coating were evaluated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and profilometry. The corrosion resistance of PTM was evaluated with an electrochemical workstation. The biocompatibility and bioactivity of coated bone marrow mesenchymal stem cells (BMSCs) were evaluated through in vitro cell experiments. RESULTS: A copper- and cobalt-doped porous coating was successfully prepared on the surface of titanium, and the doping of copper and cobalt did not change the surface topography of the coating. The porous coating increased the surface roughness of titanium and improved its resistance to corrosion. In addition, the porous coating doped with copper and cobalt promoted the adhesion and spreading of BMSCs. CONCLUSIONS: A porous coating doped with copper and cobalt was prepared on the surface of titanium through plasma electrolytic oxidation. The coating not only improved the roughness and corrosion resistance of titanium but also exhibited good biological activity.


Assuntos
Materiais Revestidos Biocompatíveis , Cobalto , Cobre , Células-Tronco Mesenquimais , Propriedades de Superfície , Titânio , Titânio/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Cobre/química , Porosidade , Cobalto/química , Animais , Corrosão , Teste de Materiais , Células Cultivadas , Próteses e Implantes
12.
J Dent ; 145: 105033, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38697505

RESUMO

OBJECTIVES: This study aimed to enhance gingival fibroblast function and to achieve antibacterial activity around the implant abutment by using a zinc (Zn)-containing bioactive glass (BG) coating. METHODS: 45S5 BG containing 0, 5, and 10 wt.% Zn were coated on zirconia disks. The release of silica and Zn ions in physiological saline and their antibacterial effects were measured. The effects of BG coatings on human gingival fibroblasts (hGFs) were assessed using cytotoxicity assays and by analyzing the gene expression of various genes related to antioxidant enzymes, wound healing, and fibrosis. RESULTS: BG coatings are capable of continuous degradation and simultaneous ion release. The antibacterial effect of BG coatings increased with the addition of Zn, while the cytotoxicity remained unchanged compared to the group without coatings. BG coating enhances the expression of angiogenesis genes, while the Zn-containing BG enhances the expression of antioxidant genes at an early time point. BG coating enhances the expression of collagen genes at later time points. CONCLUSIONS: The antibacterial effect of BG improved with the increase in Zn concentration, without inducing cytotoxicity. BG coating enhances the expression of angiogenesis genes, and Zn-containing BG enhances the expression of antioxidant genes at an early time point. BG coating enhances the expression of collagen genes at later time points. CLINICAL SIGNIFICANCE: Adding 10 wt% Zn to BG could enhance the environment around implant abutments by providing antibacterial, antioxidant, and anti-fibrotic effects, having potential for clinical use.


Assuntos
Antibacterianos , Cerâmica , Dente Suporte , Fibroblastos , Gengiva , Vidro , Propriedades de Superfície , Zinco , Zircônio , Zircônio/farmacologia , Zircônio/química , Humanos , Zinco/farmacologia , Fibroblastos/efeitos dos fármacos , Antibacterianos/farmacologia , Gengiva/citologia , Gengiva/efeitos dos fármacos , Vidro/química , Cerâmica/farmacologia , Cerâmica/química , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química , Antioxidantes/farmacologia , Teste de Materiais , Colágeno , Cicatrização/efeitos dos fármacos , Materiais Dentários/farmacologia , Materiais Dentários/química , Células Cultivadas
13.
ACS Appl Bio Mater ; 7(5): 3283-3294, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38727030

RESUMO

Medical implants are constantly facing the risk of bacterial infections, especially infections caused by multidrug resistant bacteria. To mitigate this problem, gold nanoparticles with alkyl bromide moieties (Au NPs-Br) on the surfaces were prepared. Xenon light irradiation triggered the plasmon effect of Au NPs-Br to induce free radical graft polymerization of 2-(dimethylamino)ethyl methacrylate (DMAEMA), leading to the formation of poly(DMAEMA) brush-grafted Au NPs (Au NPs-g-PDM). The Au NPs-g-PDM nanocomposites were conjugated with phytic acid (PA) via electrostatic interaction and van der Waals interaction. The as-formed aggregates were deposited on the titanium (Ti) substrates to form the PA/Au NPs-g-PDM (PAP) hybrid coatings through surface adherence of PA and the gravitational effect. Synergistic bactericidal effects of contact-killing caused by the cationic PDM brushes, and local heating generated by the Au NPs under near-infrared irradiation, conferred strong antibacterial effects on the PAP-deposited Ti (Ti-PAP) substrates. The synergistic bactericidal effects reduced the threshold temperature required for the photothermal sterilization, which in turn minimized the secondary damage to the implant site. The Ti-PAP substrates exhibited 97.34% and 99.97% antibacterial and antiadhesive efficacy, respectively, against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli), compared to the control under in vitro antimicrobial assays. Furthermore, the as-constructed Ti-PAP surface exhibited a 99.42% reduction in the inoculated S. aureus under in vivo assays. In addition, the PAP coatings exhibited good biocompatibility in the hemolysis and cytotoxicity assays as well as in the subcutaneous implantation of rats.


Assuntos
Antibacterianos , Escherichia coli , Ouro , Teste de Materiais , Nanopartículas Metálicas , Testes de Sensibilidade Microbiana , Tamanho da Partícula , Ácido Fítico , Staphylococcus aureus , Ouro/química , Ouro/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Nanopartículas Metálicas/química , Ácido Fítico/química , Ácido Fítico/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Animais , Propriedades de Superfície , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Cátions/química , Cátions/farmacologia , Polímeros/química , Polímeros/farmacologia , Titânio/química , Titânio/farmacologia
14.
ACS Appl Mater Interfaces ; 16(19): 24421-24430, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38690964

RESUMO

Periprosthetic infections caused by Staphylococcus aureus (S. aureus) pose unique challenges in orthopedic surgeries, in part due to the bacterium's capacity to invade surrounding bone tissues besides forming recalcitrant biofilms on implant surfaces. We previously developed prophylactic implant coatings for the on-demand release of vancomycin, triggered by the cleavage of an oligonucleotide (Oligo) linker by micrococcal nuclease (MN) secreted by the Gram-positive bacterium, to eradicate S. aureus surrounding the implant in vitro and in vivo. Building upon this coating platform, here we explore the feasibility of extending the on-demand release to ampicillin, a broad-spectrum aminopenicillin ß-lactam antibiotic that is more effective than vancomycin in killing Gram-negative bacteria that may accompany S. aureus infections. The amino group of ampicillin was successfully conjugated to the carboxyl end of an MN-sensitive Oligo covalently integrated in a polymethacrylate hydrogel coating applied to titanium alloy pins. The resultant Oligo-Ampicillin hydrogel coating released the ß-lactam in the presence of S. aureus and successfully cleared nearby S. aureus in vitro. When the Oligo-Ampicillin-coated pin was delivered to a rat femoral canal inoculated with 1000 cfu S. aureus, it prevented periprosthetic infection with timely on-demand drug release. The clearance of the bacteria from the pin surface as well as surrounding tissue persisted over 3 months, with no local or systemic toxicity observed with the coating. The negatively charged Oligo fragment attached to ampicillin upon cleavage from the coating did diminish the antibiotic's potency against S. aureus and Escherichia coli (E. coli) to varying degrees, likely due to electrostatic repulsion by the anionic surfaces of the bacteria. Although the on-demand release of the ß-lactam led to adequate killing of S. aureus but not E. coli in the presence of a mixture of the bacteria, strong inhibition of the colonization of the remaining E. coli on hydrogel coating was observed. These findings will inspire considerations of alternative broad-spectrum antibiotics, optimized drug conjugation, and Oligo linker engineering for more effective protection against polymicrobial periprosthetic infections.


Assuntos
Ampicilina , Antibacterianos , Materiais Revestidos Biocompatíveis , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Staphylococcus aureus , Animais , Staphylococcus aureus/efeitos dos fármacos , Ampicilina/química , Ampicilina/farmacologia , Ratos , Antibacterianos/química , Antibacterianos/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Infecções Estafilocócicas/prevenção & controle , Infecções Estafilocócicas/tratamento farmacológico , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/microbiologia , Ratos Sprague-Dawley , Testes de Sensibilidade Microbiana , Liberação Controlada de Fármacos , Próteses e Implantes
15.
Circ Cardiovasc Interv ; 17(5): e013302, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771909

RESUMO

Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant. Presently, in-stent restenosis is the condition with the most robust evidence supporting the use of DCBs. DCBs provide improved long-term vessel patency compared with conventional balloon angioplasty and may be comparable to drug-eluting stents without the need for an additional stent layer, supporting their use as a first-line therapy for in-stent restenosis. Beyond the treatment of in-stent restenosis, DCBs provide an additional tool for de novo lesions for a strategy that avoids a permanent metal scaffold, which may be especially useful for the management of technically challenging anatomies such as small vessels and bifurcations. DCBs might also be advantageous for patients with high bleeding risk due to the decreased necessity for extended antiplatelet therapy, and in patients with diabetes and patients with diffuse disease to minimize long-stented segments. Further studies are crucial to confirm these broader applications for DCBs and to further validate safety and efficacy.


Assuntos
Angioplastia Coronária com Balão , Cateteres Cardíacos , Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana , Reestenose Coronária , Humanos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Resultado do Tratamento , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Fatores de Risco , Grau de Desobstrução Vascular , Stents Farmacológicos
16.
Khirurgiia (Mosk) ; (5): 86-94, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38785243

RESUMO

OBJECTIVE: The purpose of the study was to evaluate the results of using fluoropolymer-coated mesh during intraperitoneal onlay mesh hernia repair in patients with primary ventral hernias. MATERIAL AND METHODS: The multicenter, non-randomized, controlled clinical study included 88 patients of both sexes who were operated on using a laparoscopic approach using the IPOM technique for a primary ventral hernia. The duration of observation ranged from 3 to 12 months. In the main group, 48 patients received fluoropolymer-coated meshes (Ftorex). A comparison was made with a retrospective group of 40 patients who were treated with anti-adhesive collagen-coated meshes (Parietene composite, Parietex Composite, Symbotex). RESULTS: The number of early and late postoperative complications in the groups did not have significant differences, at the same time, their number was lower in the group of patients in whom fluoropolymer-coated meshes were used. Most of the complications corresponded to Clavien-Dindo class I and II and did not pose a significant threat to health. There were no recurrences of hernias observed in patients included in the study. There were slightly more adhesions in the fluoropolymer-coated mesh group (35.4% vs. 25.0% in the collagen-coated mesh group). The quality of life of patients in the study groups did not differ. CONCLUSION: In laparoscopic IPOM hernia repair fluoropolymer-coated meshes are not inferior in effectiveness and safety to traditionally used collagen-coated meshes and can be recommended for use in patients with primary ventral hernias.


Assuntos
Hérnia Ventral , Herniorrafia , Laparoscopia , Complicações Pós-Operatórias , Telas Cirúrgicas , Humanos , Hérnia Ventral/cirurgia , Masculino , Feminino , Laparoscopia/métodos , Pessoa de Meia-Idade , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Herniorrafia/instrumentação , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Aderências Teciduais/prevenção & controle , Adulto , Materiais Revestidos Biocompatíveis , Resultado do Tratamento , Idoso , Estudos Retrospectivos , Polímeros de Fluorcarboneto , Federação Russa
17.
ACS Appl Bio Mater ; 7(5): 2872-2886, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38721671

RESUMO

Antimicrobial coatings provide protection against microbes colonization on surfaces. This can prevent the stabilization and proliferation of microorganisms. The ever-increasing levels of microbial resistance to antimicrobials are urging the development of alternative types of compounds that are potent across broad spectra of microorganisms and target different pathways. This will help to slow down the development of resistance and ideally halt it. The development of composite antimicrobial coatings (CACs) that can host and protect various antimicrobial agents and release them on demand is an approach to address this urgent need. In this work, new CACs based on microsized hybrids of calcium carbonate (CaCO3) and silver nanoparticles (AgNPs) were designed using a drop-casting technique. Polyvinylpyrrolidone and mucin were used as additives. The CaCO3/AgNPs hybrids contributed to endowing colloidal stability to the AgNPs and controlling their release, thereby ensuring the antibacterial activity of the coatings. Moreover, the additives PVP and mucin served as a matrix to (i) control the distribution of the hybrids, (ii) ensure mechanical integrity, and (iii) prevent the undesired release of AgNPs. Scanning electron microscopy (SEM), X-ray diffraction (XRD), and Fourier transform infrared (FTIR) techniques were used to characterize the 15 µm thick CAC. The antibacterial activity was determined against Escherichia coli, methicillin-resistant Staphylococcus aureus (MRSA), and Pseudomonas aeruginosa, three bacteria responsible for many healthcare infections. Antibacterial performance of the hybrids was demonstrated at concentrations between 15 and 30 µg/cm2. Unloaded CaCO3 also presented bactericidal properties against MRSA. In vitro cytotoxicity tests demonstrated that the hybrids at bactericidal concentrations did not affect human dermal fibroblasts and human mesenchymal stem cell viability. In conclusion, this work presents a simple approach for the design and testing of advanced multicomponent and functional antimicrobial coatings that can protect active agents and release them on demand.


Assuntos
Antibacterianos , Carbonato de Cálcio , Teste de Materiais , Nanopartículas Metálicas , Testes de Sensibilidade Microbiana , Tamanho da Partícula , Prata , Carbonato de Cálcio/química , Carbonato de Cálcio/farmacologia , Prata/química , Prata/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Nanopartículas Metálicas/química , Humanos , Sobrevivência Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Escherichia coli/efeitos dos fármacos , Propriedades de Superfície , Staphylococcus aureus/efeitos dos fármacos
18.
Biomed Mater ; 19(4)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38740051

RESUMO

Infectious diseases severely threaten human health, and traditional treatment techniques face multiple limitations. As an important component of immune cells, macrophages display unique biological properties, such as biocompatibility, immunocompatibility, targeting specificity, and immunoregulatory activity, and play a critical role in protecting the body against infections. The macrophage membrane-coated nanoparticles not only maintain the functions of the inner nanoparticles but also inherit the characteristics of macrophages, making them excellent tools for improving drug delivery and therapeutic implications in infectious diseases (IDs). In this review, we describe the characteristics and functions of macrophage membrane-coated nanoparticles and their advantages and challenges in ID therapy. We first summarize the pathological features of IDs, providing insight into how to fight them. Next, we focus on the classification, characteristics, and preparation of macrophage membrane-coated nanoparticles. Finally, we comprehensively describe the progress of macrophage membrane-coated nanoparticles in combating IDs, including drug delivery, inhibition and killing of pathogens, and immune modulation. At the end of this review, a look forward to the challenges of this aspect is presented.


Assuntos
Membrana Celular , Doenças Transmissíveis , Sistemas de Liberação de Medicamentos , Macrófagos , Nanopartículas , Humanos , Nanopartículas/química , Macrófagos/metabolismo , Animais , Doenças Transmissíveis/tratamento farmacológico , Membrana Celular/metabolismo , Materiais Revestidos Biocompatíveis/química
19.
J Biomed Mater Res B Appl Biomater ; 112(6): e35433, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38817048

RESUMO

Ex vivo tissue engineering is an effective therapeutic approach for the treatment of severe cartilage diseases that require tissue replenishment or replacement. This strategy demands scaffolds that are durable enough for long-term cell culture to form artificial tissue. Additionally, such scaffolds must be biocompatible to prevent the transplanted matrix from taking a toll on the patient's body. From the viewpoint of structure and bio-absorbability, a ß-tricalcium phosphate (ß-TCP) fiber scaffold (ßTFS) is expected to serve as a good scaffold for tissue engineering. However, the fragility and high solubility of ß-TCP fibers make this matrix unsuitable for long-term cell culture. To solve this problem, we developed an alginate-coated ß-TCP fiber scaffold (ßTFS-Alg). To assess cell proliferation and differentiation in the presence of ßTFS-Alg, we characterized ATDC5 cells, a chondrocyte-like cell line, when grown in this matrix. We found that alginate coated the surface of ßTFS fiber and suppressed the elution of Ca2+ from ß-TCP fibers. Due to the decreased solubility of ßTFS-Alg compared with ß-TCP, the former provided an improved scaffold for long-term cell culture. Additionally, we observed superior cell proliferation and upregulation of chondrogenesis marker genes in ATDC5 cells cultured in ßTFS-Alg. These results suggest that ßTFS-Alg is suitable for application in tissue culture.


Assuntos
Alginatos , Fosfatos de Cálcio , Alicerces Teciduais , Fosfatos de Cálcio/química , Fosfatos de Cálcio/farmacologia , Alginatos/química , Alicerces Teciduais/química , Proliferação de Células , Camundongos , Ácido Glucurônico/química , Animais , Ácidos Hexurônicos/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Linhagem Celular , Condrócitos/citologia , Condrócitos/metabolismo , Engenharia Tecidual , Teste de Materiais , Diferenciação Celular , Humanos , Técnicas de Cultura de Células
20.
Int J Mol Sci ; 25(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38791360

RESUMO

Overly fast corrosion degradation of biodegradable magnesium alloys has been a major problem over the last several years. The development of protective coatings by using biocompatible, biodegradable, and non-toxic material such as chitosan ensures a reduction in the rate of corrosion of Mg alloys in simulated body fluids. In this study, chitosan/TiO2 nanocomposite coating was used for the first time to hinder the corrosion rate of Mg19Zn1Ca alloy in Hank's solution. The main goal of this research is to investigate and explain the corrosion degradation mechanism of Mg19Zn1Ca alloy coated by nanocomposite chitosan-based coating. The chemical composition, structural analyses, and corrosion tests were used to evaluate the protective properties of the chitosan/TiO2 coating deposited on the Mg19Zn1Ca substrate. The chitosan/TiO2 coating slows down the corrosion rate of the magnesium alloy by more than threefold (3.6 times). The interaction of TiO2 (NPs) with the hydroxy and amine groups present in the chitosan molecule cause their uniform distribution in the chitosan matrix. The chitosan/TiO2 coating limits the contact of the substrate with Hank's solution.


Assuntos
Ligas , Quitosana , Materiais Revestidos Biocompatíveis , Magnésio , Titânio , Quitosana/química , Titânio/química , Ligas/química , Corrosão , Magnésio/química , Materiais Revestidos Biocompatíveis/química , Zinco/química , Teste de Materiais , Cálcio/química , Nanocompostos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...