Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.922
Filtrar
1.
Int J Implant Dent ; 10(1): 29, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839621

RESUMO

PURPOSE: This study evaluated the implant stability, volumetric changes, and patient-reported outcome measures (PROMs) of hydroxyapatite (HA) nano-coated sandblasted/acid-etched (SLA) implants compared to uncoated SLA implants. METHODS: Forty patients were recruited and randomly allocated to HA nano-coated SLA group (test, n = 20) and uncoated SLA group (control, n = 20) using single-blinded/block randomization. Implants were immediately placed in maxillary posterior region using a digital surgical guide. Insertion torque and implant stability quotient (ISQ) were measured at implant surgery and 1, 2, 3, and 4 months postoperatively. Intraoral scans, PROMs and soft tissue inflammation data were collected, and multivariable linear regression analysis of ISQ was performed. RESULTS: In total, 48 implants (test; n = 24, control; n = 24) in 37 patients (test; n = 19, control; n = 18) were analyzed. Despite no significant between-group difference at surgery, the test group showed higher ISQ values than the control group at 2 (76.53 ± 4.17 vs. 71.32 ± 4.79, p < 0.01), 3 (77.45 ± 4.41 vs. 73.85 ± 4.69, p < 0.05), and 4 months (79.08 ± 2.96 vs. 73.43 ± 3.52, p < 0.0001) postoperatively. There were no significant differences in linear and volumetric changes, PROMs, and soft tissue inflammation analysis between two groups. The ISQ at implant surgery was influenced by age and diabetes mellitus (DM) at the implant level and DM and predicted total bone-to-implant contact area at the patient level. CONCLUSION: HA nano-coated SLA implants promoted favorable immediate implants stability during early osseointegration phase compared to uncoated SLA implants, but displayed similar dimensional changes, PROMs, and soft tissue inflammation outcomes. TRIAL REGISTRATION: Clinical Research Information Service (CRIS), KCT0006364. Registered 21 July 2021, https://cris.nih.go.kr/cris/search/detailSearch.do?seq=24221&search_page=L .


Assuntos
Durapatita , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Método Simples-Cego , Implantes Dentários , Carga Imediata em Implante Dentário/métodos , Adulto , Materiais Revestidos Biocompatíveis/química , Condicionamento Ácido do Dente , Idoso , Medidas de Resultados Relatados pelo Paciente , Osseointegração , Propriedades de Superfície
2.
PLoS One ; 19(6): e0301618, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38843277

RESUMO

Periprosthetic tissue inflammation is a challenging complication arising in joint replacement surgeries, which is often caused by wear debris from polyethylene (PE) components. In this study, we examined the potential biological effects of grafting a [2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide (MEDSAH) polymer onto the surface of PE through a solvent-evaporation technique. J774A.1 macrophage-like cells and primary cultured mouse osteoblasts were treated with PE powder with or without the MEDSAH coating. MEDSAH grafting on PE substantially reduced the expression of pro-inflammatory cytokines and other mediators in primary cultured mouse osteoblasts, but did not significantly impact macrophage-mediated inflammation. Our findings suggest that a MEDSAH coating on PE-based materials has potential utility in mitigating periprosthetic tissue inflammation and osteolysis and preventing aseptic loosening in total joint replacements. Further research, including large-scale clinical trials and biomechanical analyses, is needed to assess the long-term performance and clinical implications of MEDSAH-coated PE-based materials in total joint arthroplasty.


Assuntos
Inflamação , Osteoblastos , Polietileno , Animais , Camundongos , Inflamação/patologia , Osteoblastos/metabolismo , Osteoblastos/efeitos dos fármacos , Macrófagos/metabolismo , Linhagem Celular , Citocinas/metabolismo , Osteólise/etiologia , Osteólise/patologia , Materiais Revestidos Biocompatíveis/química , Metacrilatos/química , Artroplastia de Substituição/efeitos adversos
3.
Trials ; 25(1): 370, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38851710

RESUMO

BACKGROUND: Endovascular therapy has become established as a first-line therapy in most arterial regions. However, open vascular surgery (endarterectomy) remains the treatment of choice for common femoral artery (CFA) lesions. The aim of this study is to investigate the acute and mid-term results of directional atherectomy plus drug-coated balloon (DCB) in comparison to endarterectomy in treatment of de novo arteriosclerotic CFA lesions. METHODS: This prospective, randomized, multicenter non-inferiority study will enroll 306 participants with symptomatic (Rutherford category 1 to 5) de novo stenosis of the CFA including the bifurcation. Patients eligible for both treatment groups could be included in this 1:1 randomized trial. Primary efficacy endpoint is patency of the target lesion at 12 months defined as restenosis < 50% without the need of clinically driven target lesion revascularization (cdTLR). Primary safety endpoint is a combined endpoint including death, myocardial infarction, major or minor amputation of the target limb, and peri-procedural complications at 30 days. Secondary endpoints include primary patency of the target lesion at 6 and 24 months, secondary patency, cdTLR 6, 12, and 24 months, change in ankle-brachial index, and Rutherford-Becker class at 6, 12, and 24 months. Limb salvage, change in quality of life measured by Walking Impairment Questionnaire, and major adverse events including death, myocardial infarction, and minor or major amputation of the target limb will be determined at 6, 12, 24, and 36 months. DISCUSSION: Endovascular treatment of CFA lesions is still a matter of debate. Few studies compared modern endovascular therapy methods against the so-called gold standard surgical endarterectomy so far. Based on recent positive results, this study aims to confirm non-inferiority of a "leaving nothing behind" endovascular approach combining directional atherectomy and DCB compared to surgical therapy. TRIAL REGISTRATION: ClinicalTrials.gov NCT02517827.


Assuntos
Endarterectomia , Artéria Femoral , Doença Arterial Periférica , Grau de Desobstrução Vascular , Humanos , Artéria Femoral/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Doença Arterial Periférica/terapia , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/fisiopatologia , Fatores de Tempo , Endarterectomia/efeitos adversos , Endarterectomia/métodos , Aterectomia/efeitos adversos , Aterectomia/métodos , Estudos Multicêntricos como Assunto , Estudos de Equivalência como Asunto , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Angioplastia com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Salvamento de Membro , Qualidade de Vida , Dispositivos de Acesso Vascular , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Med Sci Monit ; 30: e944255, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38843112

RESUMO

Orthodontic treatments, while essential for achieving optimal oral health, present challenges in infection control due to the propensity for bacterial adhesion and biofilm formation on orthodontic appliances. Silver-coated orthodontic materials have emerged as a promising solution, leveraging the potent antimicrobial properties of silver nanoparticles (AgNPs). Antibacterial coatings are used in orthodontics to prevent the formation of bacterial biofilms. This systematic review evaluated the literature on antimicrobial silver coatings on fixed orthodontic appliances, including archwires, brackets, and microimplants. Two evaluators, working independently, rigorously conducted a comprehensive search of various databases, including PubMed, PubMed Central, Embase, Scopus and Web of Science. This systematic review comprehensively examined in vitro studies investigating the antimicrobial efficacy of silver-coated orthodontic archwires, brackets, and microimplants. The review registered in PROSPERO CRD42024509189 synthesized findings from 18 diverse studies, revealing consistent and significant reductions in bacterial adhesion, biofilm formation, and colony counts with the incorporation of AgNPs. Key studies demonstrated the effectiveness of silver-coated archwires and brackets against common oral bacteria, such as Streptococcus mutans and Staphylococcus aureus. Microimplants coated with AgNPs also exhibited notable antimicrobial activity against a range of microorganisms. The systematic review revealed potential mechanisms underlying these antimicrobial effects, highlighted implications for infection prevention in orthodontic practice, and suggested future research avenues. Despite some study heterogeneity and limitations, the collective evidence supports the potential of silver-coated orthodontic materials in mitigating bacterial complications, emphasizing their relevance in advancing infection control measures in orthodontics.


Assuntos
Biofilmes , Nanopartículas Metálicas , Braquetes Ortodônticos , Prata , Prata/farmacologia , Humanos , Biofilmes/efeitos dos fármacos , Braquetes Ortodônticos/microbiologia , Fios Ortodônticos/microbiologia , Aparelhos Ortodônticos Fixos , Anti-Infecciosos/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Antibacterianos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Aderência Bacteriana/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos
5.
Carbohydr Polym ; 339: 122288, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38823936

RESUMO

This paper reports on biofunctionalisation of a poly(lactic acid) (PLA) film by surface activation through cold plasma treatment followed by coating with a chitosan-gelatin xerogel. The UV cross-linking of the xerogel precursor was simultaneously performed with the fixation onto the PLA support. This has a strong effect on surface properties, in terms of wettability, surface free energy, morphology and micromechanical features. The hydrophilic - hydrophobic character of the surface, determined by contact angle measurements, was tuned along the process, passing from moderate hydrophobic PLA to enhanced hydrophilic plasma activated surface, which favors coating adhesion, then to moderate hydrophobic chitosan-gelatin coating. The coating has a Lewis amphoteric surface, with a porous xerogel-like morphology, as revealed by scanning electron microscopy images. By riboflavin mediated UV cross-linking the chitosan-gelatin coating becomes high adhesive and with a more pronounced plasticity, as shown by AFM force-distance spectroscopy. Thus prepared surface-coated PLA supports were successfully tested for growth of dermal fibroblasts, which are known for their induction potential of chondrogenic cells, which is very important in cartilage tissue engineering.


Assuntos
Quitosana , Fibroblastos , Gelatina , Poliésteres , Quitosana/química , Gelatina/química , Poliésteres/química , Fibroblastos/efeitos dos fármacos , Fibroblastos/citologia , Humanos , Propriedades de Superfície , Géis/química , Raios Ultravioleta , Gases em Plasma/química , Interações Hidrofóbicas e Hidrofílicas , Materiais Revestidos Biocompatíveis/química , Reagentes de Ligações Cruzadas/química , Molhabilidade
6.
Biointerphases ; 19(3)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38836787

RESUMO

Titanium (Ti) is widely utilized as an implant material; nonetheless, its integration with bone tissue faces limitations due to a patient's comorbidities. To address this challenge, we employed a strategic approach involving the growth of thin films by spin-coating and surface functionalization with etidronate (ETI), alendronate (ALE), and risedronate (RIS). Our methodology involved coating of Ti cp IV disks with thin films of TiO2, hydroxyapatite (HA), and their combinations (1:1 and 1:2 v/v), followed by surface functionalization with ETI, ALE, and RIS. Bisphosphonate-doped films were evaluated in terms of surface morphology and physical-chemical properties by techniques such as electron microscopy, confocal microscopy, and x-ray photoelectron spectroscopy. The antibacterial potential of bisphosphonates alone or functionalized onto the Ti surface was tested against Staphylococcus aureus biofilms. Primary human bone mesenchymal stem cells were used to determine in vitro cell metabolism and mineralization. Although RIS alone did not demonstrate any antibacterial effect as verified by minimum inhibitory concentration assay, when Ti surfaces were functionalized with RIS, partial inhibition of Staphylococcus aureus growth was noted, probably because of the physical-chemical surface properties. Furthermore, samples comprising TiO2/HA (1:1 and 1:2 v/v) showcased an enhancement in the metabolism of nondifferentiated cells and can potentially enhance the differentiation of osteoblastic precursors. All samples demonstrated cell viability higher than 80%. Addition of hydroxyapatite and presence of bisphosphonates increase the metabolic activity and the mineralization of human bone mesenchymal cells. While these findings hold promise, it is necessary to conduct further studies to evaluate the system's performance in vivo and ensure its long-term safety. This research marks a significant stride toward optimizing the efficacy of titanium implants through tailored surface modifications.


Assuntos
Antibacterianos , Difosfonatos , Células-Tronco Mesenquimais , Testes de Sensibilidade Microbiana , Staphylococcus aureus , Propriedades de Superfície , Titânio , Titânio/química , Titânio/farmacologia , Humanos , Antibacterianos/farmacologia , Antibacterianos/química , Staphylococcus aureus/efeitos dos fármacos , Difosfonatos/química , Difosfonatos/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Células Cultivadas , Durapatita/química , Durapatita/farmacologia
7.
Int J Nanomedicine ; 19: 5011-5020, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38832337

RESUMO

Purpose: Atomic layer deposition (ALD) is a method that can deposit zirconia uniformly on an atomic basis. The effect of deposited zirconia on titanium implants using ALD was evaluated in vivo. Methods: Machined titanium implants (MTIs) were used as the Control. MTIs treated by sandblasting with large grit and acid etching (SA) and MTIs deposited with zirconia using ALD are referred to as Groups S and Z, respectively. Twelve implants were prepared for each group. Six rabbits were used as experimental animals. To evaluate the osteogenesis and osteocyte aspects around the implants, radiological and histological analyses were performed. The bone-to-implant contact (BIC) ratio was measured and statistically analyzed to evaluate the osseointegration capabilities. Results: In the micro-CT analysis, more radiopaque bone tissues were observed around the implants in Groups S and Z. Histological observation found that Groups S and Z had more and denser mature bone tissues around the implants in the cortical bone area. Many new and mature bone tissues were also observed in the medullary cavity area. For the BIC ratio, Groups S and Z were significantly higher than the Control in the cortical bone area (P < 0.017), but there was no significant difference between Groups S and Z. Conclusion: MTIs deposited with zirconia using ALD (Group Z) radiologically and histologically showed more mature bone formation and activated osteocytes compared with MTIs (Control). Group Z also had a significantly higher BIC ratio than the Control. Within the limitations of this study, depositing zirconia on the surface of MTIs using ALD can improve osseointegration in vivo.


Assuntos
Osseointegração , Titânio , Zircônio , Animais , Zircônio/química , Zircônio/farmacologia , Coelhos , Titânio/química , Titânio/farmacologia , Osseointegração/efeitos dos fármacos , Propriedades de Superfície , Microtomografia por Raio-X , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Interface Osso-Implante , Osteogênese/efeitos dos fármacos , Implantes Dentários , Próteses e Implantes
8.
JACC Cardiovasc Interv ; 17(9): 1134-1144, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38749594

RESUMO

BACKGROUND: Limited comparative data exist on different interventional strategies for endovascular revascularization of complex femoropopliteal interventions. OBJECTIVES: In this study, the authors aimed to compare a stent-avoiding (SA) vs a stent-preferred (SP) strategy, promoting optimal lesion preparation and the use of drug-eluting technologies in both arms. METHODS: Within a prospective, multicenter, pilot study, 120 patients with symptomatic complex femoropopliteal lesions (Rutherford classification 2-4, mean lesion length 187.7 ± 78.3 mm, 79.2% total occlusions) were randomly assigned in a 1:1 fashion to endovascular treatment with either paclitaxel-coated balloons or polymer-coated, paclitaxel-eluting stents. Lesion preparation including the use of devices for plaque modification and/or removal was at the operators' discretion in both treatment arms. RESULTS: In the SA group, lesion preparation was more frequently performed (71.7% SA [43/60] vs 51.7% [31/60] SP; P = 0.038) with a high provisional stenting rate (48.3% [29/60]). At the 12-month follow-up, primary patency was 78.2% (43/55) in the SA group and 78.6% (44/56) in the SP group (P = 1.0; relative risk: 0.995; 95% CI: 0.818-1.210). Freedom from major adverse events was determined in 93.1% (54/58) in the SA group and in 94.9% (56/59) in the SP group (P = 0.717; relative risk: 0.981; 95% CI: 0.895-1.075), with all adverse events attributable to clinically driven target lesion revascularization. CONCLUSIONS: Both endovascular strategies promoting lesion preparation before the use of drug-eluting devices suggest promising efficacy and safety results in complex femoropopliteal procedures with a high proportion of total occlusions through 12 months. Ongoing follow-up will show whether different results emerge over time. (Best Endovascular Strategy for Complex Lesions of the Superficial Femoral Artery [BEST-SFA]; NCT03776799).


Assuntos
Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Artéria Femoral , Paclitaxel , Doença Arterial Periférica , Artéria Poplítea , Desenho de Prótese , Grau de Desobstrução Vascular , Humanos , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Masculino , Feminino , Idoso , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Paclitaxel/administração & dosagem , Fatores de Tempo , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Projetos Piloto , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Fatores de Risco , Idoso de 80 Anos ou mais , Dispositivos de Acesso Vascular
10.
ACS Appl Mater Interfaces ; 16(19): 24274-24294, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38699930

RESUMO

In the field of bone tissue engineering, recently developed Zn alloy scaffolds are considered potential candidates for biodegradable implants for bone regeneration and defect reconstruction. However, the clinical success of these alloys is limited due to their insufficient surface bioactivities. Further, the higher concentration of Zn2+ produced during degradation promotes antibacterial activity, but deteriorates osteogenic properties. This study fabricated an Azadirachta indica (neem)-assisted brushite-hydroxyapatite (HAp) coating on the recently developed Zn-2Cu-0.5Mg alloy to tackle the above dilemma. The microstructure, degradation behavior, antibacterial activity, and hemocompatibility, along with in vitro and in vivo cytocompatibility of the coated alloys, are systematically investigated. Microstructural analysis reveals flower-like morphology with uniformly grown flakes for neem-assisted deposition. The neem-assisted deposition significantly improves the adhesion strength from 12.7 to 18.8 MPa, enhancing the mechanical integrity. The potentiodynamic polarization study shows that the neem-assisted deposition decreases the degradation rate, with the lowest degradation rate of 0.027 mm/yr for the ZHN2 sample. In addition, the biomineralization process shows the apatite formation on the deposited coating after 21 days of immersion. In vitro cytotoxicity assay exhibits the maximum cell viability of 117% for neem-assisted coated alloy in 30% extract after 5d and the improved cytocompatibility which is due to the controlled release of Zn2+ ions. Meanwhile, neem-assisted coated alloy increases the ZOI by 32 and 24% for Gram-positive and Gram-negative bacteria, respectively. Acceptable hemolysis (<5%) and anticoagulation parameters demonstrate a promising hemocompatibility of the coated alloy. In vivo implantation illustrates a slight inflammatory response and vascularization after 2 weeks of subcutaneous implantation, and neo-bone formation in the defect areas of the rat femur. Micro-CT and histology studies demonstrate better osseointegration with satisfactory biosafety response for the neem-assisted coated alloy as compared to that without neem-assisted deposition. Hence, this neem-assisted brushite-Hap coating strategy elucidates a new perspective on the surface modification of biodegradable implants for the treatment of bone defects.


Assuntos
Ligas , Fosfatos de Cálcio , Materiais Revestidos Biocompatíveis , Zinco , Ligas/química , Ligas/farmacologia , Zinco/química , Zinco/farmacologia , Animais , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Fosfatos de Cálcio/química , Fosfatos de Cálcio/farmacologia , Antibacterianos/química , Antibacterianos/farmacologia , Humanos , Durapatita/química , Durapatita/farmacologia , Teste de Materiais , Camundongos , Química Verde , Implantes Absorvíveis
11.
ACS Appl Mater Interfaces ; 16(19): 24321-24340, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38700914

RESUMO

In current clinical practices related to orthopedics, dental, and cardiovascular surgeries, a number of biomaterial coatings, such as hydroxyapatite (HAp), diamond-like carbon (DLC), have been used in combination with metallic substrates (stainless steel, Ti6Al4V alloy, etc.). Although SiBCN coatings are widely explored in material science for diverse applications, their potential remains largely unexplored for biomedical applications. With this motivation, the present work reports the development of SiBxCyNzOm coatings on a Ti6Al4V substrate, employing a reactive radiofrequency (RF) magnetron sputtering technique. Three different coating compositions (Si0.27B0.10C0.31N0.07O0.24, Si0.23B0.06C0.21N0.22O0.27, and Si0.20B0.05C0.19N0.20O0.35) were obtained using a Si2BC2N target and varying nitrogen flow rates. The hydrophilic properties of the as-synthesized coatings were rationalized in terms of an increase in the number of oxygen-containing functional groups (OH and NO) on the surface, as probed using XPS and FTIR analyses. Furthermore, the cellular monoculture of SVEC4-10 endothelial cells and L929 fibroblasts established good cytocompatibility. More importantly, the coculture system of SVEC4-10 and L929, in the absence of growth factors, demonstrated clear cellular phenotypical changes, with extensive sprouting leading to tube-like morphologies on the coating surfaces, when stimulated using a customized cell stimulator (StimuCell) with 1.15 V/cm direct current (DC) electric field strength for 1 h. In addition, the hemocompatibility assessment using human blood samples revealed clinically acceptable hemolysis, less erythrocyte adhesion, shorter plasma recalcification, and reduced risk for thrombosis on the SiBxCyNzOm coatings, when compared to uncoated Ti6Al4V. Taken together, the present study unambiguously establishes excellent cytocompatibility, hemocompatibility, and defines the preangiogenic properties of SiBxCyNzOm bioceramic coatings for potential biomedical applications.


Assuntos
Ligas , Materiais Revestidos Biocompatíveis , Teste de Materiais , Titânio , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Ligas/química , Ligas/farmacologia , Titânio/química , Titânio/farmacologia , Humanos , Animais , Camundongos , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/citologia , Linhagem Celular , Propriedades de Superfície , Fibroblastos/efeitos dos fármacos , Fibroblastos/citologia , Neovascularização Fisiológica/efeitos dos fármacos
12.
Clin Oral Investig ; 28(6): 323, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38761310

RESUMO

OBJECTIVES: White spot lesions are the most common iatrogenic effect observed during orthodontic treatment. This study aimed to compare the surface characteristics and antibacterial action of uncoated and coated orthodontic brackets. MATERIALS AND METHODS: Sixty commercially available stainless steel brackets were coated with TiO2 nanotubes and methacryloyloxyethylphosphorylcholine. The sample was divided into Group 1: uncoated orthodontic brackets, Group 2: Stainless steel brackets with TiO2 nanotubes coating, Group 3: Stainless steel brackets with methacryloyloxyethylphosphorylcholine coating, and Group 4: Stainless steel brackets with TiO2 nanotubes combined with methacryloyloxyethylphosphorylcholine coating. Surface characterization was assessed using atomic force microscopy and scanning electron microscopy. Streptococcus mutans was selected to test the antibacterial ability of the orthodontic brackets, total bacterial adhesion and bacterial viability were assessed. The brackets were subjected to scanning electron microscopy to detect the presence of biofilm. RESULTS: The surface roughness was the greatest in Group 1 and least in Group 2 followed by Group 4 and Group 3 coated brackets. The optical density values were highest in Group 1 and lowest in Group 4. Comparison of colony counts revealed high counts in Group 1 and low counts in Group 4. A positive correlation between surface roughness and colony counts was obtained, however, was not statistically significant. CONCLUSIONS: The coated orthodontic brackets exhibited less surface roughness than the uncoated orthodontic brackets. Group 4 coated orthodontic brackets showed the best antibacterial properties. CLINICAL RELEVANCE: Coated orthodontic brackets prevent adhesion of streptococcus mutans and reduces plaque accumulation around the brackets thereby preventing formation of white spot lesions during orthodontic treatment.


Assuntos
Antibacterianos , Aderência Bacteriana , Microscopia Eletrônica de Varredura , Nanotubos , Braquetes Ortodônticos , Fosforilcolina , Streptococcus mutans , Propriedades de Superfície , Titânio , Titânio/química , Fosforilcolina/análogos & derivados , Fosforilcolina/farmacologia , Fosforilcolina/química , Streptococcus mutans/efeitos dos fármacos , Antibacterianos/farmacologia , Nanotubos/química , Aderência Bacteriana/efeitos dos fármacos , Microscopia de Força Atômica , Teste de Materiais , Aço Inoxidável/química , Metacrilatos/farmacologia , Metacrilatos/química , Biofilmes/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química
13.
Biomed Mater ; 19(4)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38740037

RESUMO

The purpose of this study was to construct a rutin-controlled release system on the surface of Ti substrates and investigate its effects on osteogenesis and osseointegration on the surface of implants. The base layer, polyethylenimine (PEI), was immobilised on a titanium substrate. Then, hyaluronic acid (HA)/chitosan (CS)-rutin (RT) multilayer films were assembled on the PEI using layer-by-layer (LBL) assembly technology. We used scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and contact angle measurements to examine all Ti samples. The drug release test of rutin was also carried out to detect the slow-release performance. The osteogenic abilities of the samples were evaluated by experiments on an osteoporosis rat model and MC3T3-E1 cells. The results (SEM, FTIR and contact angle measurements) all confirmed that the PEI substrate layer and HA/CS-RT multilayer film were effectively immobilised on titanium. The drug release test revealed that a rutin controlled release mechanism had been successfully established. Furthermore, thein vitrodata revealed that osteoblasts on the coated titanium matrix had greater adhesion, proliferation, and differentiation capacity than the osteoblasts on the pure titanium surface. When MC3T3-E1 cells were exposed to H2O2-induced oxidative stressin vitro, cell-based tests revealed great tolerance and increased osteogenic potential on HA/CS-RT substrates. We also found that the HA/CS-RT coating significantly increased the new bone mass around the implant. The LBL-deposited HA/CS-RT multilayer coating on the titanium base surface established an excellent rutin-controlled release system, which significantly improved osseointegration and promoted osteogenesis under oxidative stress conditions, suggesting a new implant therapy strategy for patients with osteoporosis.


Assuntos
Materiais Revestidos Biocompatíveis , Ácido Hialurônico , Osseointegração , Osteoblastos , Osteogênese , Osteoporose , Próteses e Implantes , Rutina , Propriedades de Superfície , Titânio , Animais , Titânio/química , Rutina/química , Rutina/farmacologia , Osteogênese/efeitos dos fármacos , Ratos , Osteoporose/tratamento farmacológico , Camundongos , Osteoblastos/efeitos dos fármacos , Osteoblastos/citologia , Osteoblastos/metabolismo , Osseointegração/efeitos dos fármacos , Ácido Hialurônico/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Oxirredução , Quitosana/química , Feminino , Ratos Sprague-Dawley , Adesão Celular/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Diferenciação Celular/efeitos dos fármacos , Microscopia Eletrônica de Varredura , Proliferação de Células/efeitos dos fármacos , Polietilenoimina/química , Células 3T3 , Estresse Oxidativo/efeitos dos fármacos , Nanopartículas em Multicamadas
14.
Circ Cardiovasc Interv ; 17(5): e013302, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771909

RESUMO

Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant. Presently, in-stent restenosis is the condition with the most robust evidence supporting the use of DCBs. DCBs provide improved long-term vessel patency compared with conventional balloon angioplasty and may be comparable to drug-eluting stents without the need for an additional stent layer, supporting their use as a first-line therapy for in-stent restenosis. Beyond the treatment of in-stent restenosis, DCBs provide an additional tool for de novo lesions for a strategy that avoids a permanent metal scaffold, which may be especially useful for the management of technically challenging anatomies such as small vessels and bifurcations. DCBs might also be advantageous for patients with high bleeding risk due to the decreased necessity for extended antiplatelet therapy, and in patients with diabetes and patients with diffuse disease to minimize long-stented segments. Further studies are crucial to confirm these broader applications for DCBs and to further validate safety and efficacy.


Assuntos
Angioplastia Coronária com Balão , Cateteres Cardíacos , Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana , Reestenose Coronária , Humanos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Resultado do Tratamento , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Fatores de Risco , Grau de Desobstrução Vascular , Stents Farmacológicos
15.
Int J Nanomedicine ; 19: 4515-4531, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803996

RESUMO

Introduction: There is an ongoing need for improved healing response and expedited osseointegration on the Ti implants in acetabular fracture sites. To achieve adequate bonding and mechanical stability between the implant surface and the acetabular fracture, a new coating technology must be developed to promote bone integration and prevent bacterial growth. Methods: A cylindrical Ti substrate mounted on a rotating specimen holder was used to implant Ca2+, P2+, and Sr2+ ions at energies of 100 KeV, 75 KeV and 180 KeV, respectively, using a low-energy accelerator to synthesize strontium-substituted hydroxyapatite at varying conditions. Ag2+ ions of energy 100 KeV were subsequently implanted on the as-formed surface at the near-surface region to provide anti-bacterial properties to the as-formed specimen. Results: The properties of the as-formed ion-implanted specimen were compared with the SrHA-Ag synthesized specimens by cathodic deposition and low-temperature high-speed collision technique. The adhesion strength of the ion-implanted specimen was 43 ± 2.3 MPa, which is well above the ASTM standard for Ca-P coating on Ti. Live/dead cell analysis showed higher osteoblast activity on the ion-implanted specimen than the other two. Ag in the SrHA implanted Ti by ion implantation process showed superior antibacterial activity. Discussion: In the ion implantation technique, nano-topography patterned surfaces are not concealed after implantation, and their efficacy in interacting with the osteoblasts is retained. Although all three studies examined the antibacterial effects of Ag2+ ions and the ability to promote bone tissue formation by MC3T3-E1 cells on SrHA-Ag/Ti surfaces, ion implantation techniques demonstrated superior ability. The synthesized specimen can be used as an effective implant in acetabular fracture sites based on their mechanical and biological properties.


Assuntos
Acetábulo , Antibacterianos , Prata , Estrôncio , Titânio , Titânio/química , Titânio/farmacologia , Prata/química , Prata/farmacologia , Estrôncio/química , Estrôncio/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Acetábulo/lesões , Animais , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Osseointegração/efeitos dos fármacos , Camundongos , Propriedades de Superfície , Fraturas Ósseas/terapia , Durapatita/química , Durapatita/farmacologia , Osteoblastos/efeitos dos fármacos , Hidroxiapatitas/química , Hidroxiapatitas/farmacologia , Próteses e Implantes , Íons/química , Íons/farmacologia , Humanos , Linhagem Celular
16.
Langmuir ; 40(21): 10957-10965, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38752656

RESUMO

Zwitterionic coatings provide a promising antifouling strategy against biofouling adhesion. Quaternary ammonium cationic polymers can effectively kill bacteria on the surface, owing to their positive charges. This strategy can avoid the release of toxic biocides, which is highly desirable for constructing coatings for biomedical devices. The present work aims to develop a facile method by covalently grafting zwitterionic and cationic copolymers containing aldehydes to the remaining amine groups of self-polymerized dopamine. Reversible addition-fragmentation chain transfer polymerization was used to copolymerize either zwitterionic 2-methacryloyloxyethyl phosphorylcholine monomer (MPC) or cationic 2-(methacryloyloxy)ethyl trimethylammonium monomer (META) with 4-formyl phenyl methacrylate monomer (FPMA), and the formed copolymers poly(MPC-st-FPMA) and poly(META-st-FPMA) are denoted as MPF and MTF, respectively. MPF and MTF copolymers were then covalently grafted onto the amino groups of polydopamine-coated surfaces. PDA/MPF/MTF-coated surfaces exhibited antibacterial and antifouling properties against S. aureus, E. coli, and bovine serum albumin protein. In addition, they showed excellent viability of normal human lung fibroblast cells MRC-5. We expect the facile surface modification strategy discussed here to be applicable to medical device manufacturing.


Assuntos
Antibacterianos , Polímeros , Staphylococcus aureus , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Polímeros/química , Polímeros/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Animais , Incrustação Biológica/prevenção & controle , Escherichia coli/efeitos dos fármacos , Bivalves/química , Propriedades de Superfície , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Fosforilcolina/análogos & derivados , Fosforilcolina/química , Fosforilcolina/farmacologia , Soroalbumina Bovina/química , Humanos , Metacrilatos/química , Metacrilatos/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Indóis
17.
Eur Rev Med Pharmacol Sci ; 28(9): 3391-3402, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766802

RESUMO

OBJECTIVE: Although pure titanium (PT) and its alloys exhibit excellent mechanical properties, they lack biological activity as implants. The purpose of this study was to improve the biological activity of titanium implants through surface modification. MATERIALS AND METHODS: Titanium was processed into titanium discs, where the titanium discs served as anodes and stainless steel served as cathodes, and a copper- and cobalt-doped porous coating [pure titanium model (PTM)] was prepared on the surface of titanium via plasma electrolytic oxidation. The surface characteristics of the coating were evaluated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and profilometry. The corrosion resistance of PTM was evaluated with an electrochemical workstation. The biocompatibility and bioactivity of coated bone marrow mesenchymal stem cells (BMSCs) were evaluated through in vitro cell experiments. RESULTS: A copper- and cobalt-doped porous coating was successfully prepared on the surface of titanium, and the doping of copper and cobalt did not change the surface topography of the coating. The porous coating increased the surface roughness of titanium and improved its resistance to corrosion. In addition, the porous coating doped with copper and cobalt promoted the adhesion and spreading of BMSCs. CONCLUSIONS: A porous coating doped with copper and cobalt was prepared on the surface of titanium through plasma electrolytic oxidation. The coating not only improved the roughness and corrosion resistance of titanium but also exhibited good biological activity.


Assuntos
Materiais Revestidos Biocompatíveis , Cobalto , Cobre , Células-Tronco Mesenquimais , Propriedades de Superfície , Titânio , Titânio/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Cobre/química , Porosidade , Cobalto/química , Animais , Corrosão , Teste de Materiais , Células Cultivadas , Próteses e Implantes
18.
Khirurgiia (Mosk) ; (5): 86-94, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38785243

RESUMO

OBJECTIVE: The purpose of the study was to evaluate the results of using fluoropolymer-coated mesh during intraperitoneal onlay mesh hernia repair in patients with primary ventral hernias. MATERIAL AND METHODS: The multicenter, non-randomized, controlled clinical study included 88 patients of both sexes who were operated on using a laparoscopic approach using the IPOM technique for a primary ventral hernia. The duration of observation ranged from 3 to 12 months. In the main group, 48 patients received fluoropolymer-coated meshes (Ftorex). A comparison was made with a retrospective group of 40 patients who were treated with anti-adhesive collagen-coated meshes (Parietene composite, Parietex Composite, Symbotex). RESULTS: The number of early and late postoperative complications in the groups did not have significant differences, at the same time, their number was lower in the group of patients in whom fluoropolymer-coated meshes were used. Most of the complications corresponded to Clavien-Dindo class I and II and did not pose a significant threat to health. There were no recurrences of hernias observed in patients included in the study. There were slightly more adhesions in the fluoropolymer-coated mesh group (35.4% vs. 25.0% in the collagen-coated mesh group). The quality of life of patients in the study groups did not differ. CONCLUSION: In laparoscopic IPOM hernia repair fluoropolymer-coated meshes are not inferior in effectiveness and safety to traditionally used collagen-coated meshes and can be recommended for use in patients with primary ventral hernias.


Assuntos
Hérnia Ventral , Herniorrafia , Laparoscopia , Complicações Pós-Operatórias , Telas Cirúrgicas , Humanos , Hérnia Ventral/cirurgia , Masculino , Feminino , Laparoscopia/métodos , Pessoa de Meia-Idade , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Herniorrafia/instrumentação , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Aderências Teciduais/prevenção & controle , Adulto , Materiais Revestidos Biocompatíveis , Resultado do Tratamento , Idoso , Estudos Retrospectivos , Polímeros de Fluorcarboneto , Federação Russa
19.
Int J Mol Sci ; 25(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38791360

RESUMO

Overly fast corrosion degradation of biodegradable magnesium alloys has been a major problem over the last several years. The development of protective coatings by using biocompatible, biodegradable, and non-toxic material such as chitosan ensures a reduction in the rate of corrosion of Mg alloys in simulated body fluids. In this study, chitosan/TiO2 nanocomposite coating was used for the first time to hinder the corrosion rate of Mg19Zn1Ca alloy in Hank's solution. The main goal of this research is to investigate and explain the corrosion degradation mechanism of Mg19Zn1Ca alloy coated by nanocomposite chitosan-based coating. The chemical composition, structural analyses, and corrosion tests were used to evaluate the protective properties of the chitosan/TiO2 coating deposited on the Mg19Zn1Ca substrate. The chitosan/TiO2 coating slows down the corrosion rate of the magnesium alloy by more than threefold (3.6 times). The interaction of TiO2 (NPs) with the hydroxy and amine groups present in the chitosan molecule cause their uniform distribution in the chitosan matrix. The chitosan/TiO2 coating limits the contact of the substrate with Hank's solution.


Assuntos
Ligas , Quitosana , Materiais Revestidos Biocompatíveis , Magnésio , Titânio , Quitosana/química , Titânio/química , Ligas/química , Corrosão , Magnésio/química , Materiais Revestidos Biocompatíveis/química , Zinco/química , Teste de Materiais , Cálcio/química , Nanocompostos/química
20.
Biomaterials ; 309: 122602, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38768544

RESUMO

Endotracheal Tubes (ETTs) maintain and secure a patent airway; however, prolonged intubation often results in unintended injury to the mucosal epithelium and inflammatory sequelae which complicate recovery. ETT design and materials used have yet to adapt to address intubation associated complications. In this study, a composite coating of electrospun polycaprolactone (PCL) fibers embedded in a four-arm polyethylene glycol acrylate matrix (4APEGA) is developed to transform the ETT from a mechanical device to a dual-purpose device capable of delivering multiple therapeutics while preserving coating integrity. Further, the composite coating system (PCL-4APEGA) is capable of sustained delivery of dexamethasone from the PCL phase and small interfering RNA (siRNA) containing polyplexes from the 4APEGA phase. The siRNA is released rapidly and targets smad3 for immediate reduction in pro-fibrotic transforming growth factor-beta 1 (TGFϐ1) signaling in the upper airway mucosa as well as suppressing long-term sequelae in inflammation from prolonged intubation. A bioreactor was used to study mucosal adhesion to the composite PCL-4APEGA coated ETTs and investigate continued mucus secretory function in ex vivo epithelial samples. The addition of the 4APEGA coating and siRNA delivery to the dexamethasone delivery was then evaluated in a swine model of intubation injury and observed to restore mechanical function of the vocal folds and maintain epithelial thickness when observed over 14 days of intubation. This study demonstrated that increase in surface lubrication paired with surface stiffness reduction significantly decreased fibrotic behavior while reducing epithelial adhesion and abrasion.


Assuntos
Dexametasona , Sistemas de Liberação de Medicamentos , Intubação Intratraqueal , RNA Interferente Pequeno , Animais , Dexametasona/farmacologia , Materiais Revestidos Biocompatíveis/química , Poliésteres/química , Suínos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...