Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.042
Filtrar
2.
Vestn Otorinolaringol ; 89(2): 10-14, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38805457

RESUMO

An explosion is a process that rapidly releases a huge amount of energy in the form of heat, kinetic energy, and high-pressure shock waves. Since the organ of hearing is most susceptible to pressure changes, damage to the sound-conducting or sound-receiving systems is inevitable in case of an explosive injury. This article examines the mechanism of formation of explosive injuries of the middle and inner ear in children and adolescents, the features of diagnosis and tactics of surgical reconstructive treatment of explosive ear injuries based on the data available in the scientific literature and their own experience.


Assuntos
Traumatismos por Explosões , Procedimentos Cirúrgicos Otológicos , Humanos , Traumatismos por Explosões/cirurgia , Traumatismos por Explosões/fisiopatologia , Criança , Procedimentos Cirúrgicos Otológicos/métodos , Procedimentos Cirúrgicos Otológicos/efeitos adversos , Adolescente , Procedimentos de Cirurgia Plástica/métodos , Orelha Média/cirurgia , Orelha Média/lesões , Orelha Média/fisiopatologia , Orelha Interna/lesões , Orelha Interna/cirurgia , Orelha Interna/fisiopatologia
3.
J Acoust Soc Am ; 155(4): 2769-2785, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38662609

RESUMO

Assuming plane waves, ear-canal acoustic quantities, collectively known as wideband acoustic immittance (WAI), are frequently used in research and in the clinic to assess the conductive status of the middle ear. Secondary applications include compensating for the ear-canal acoustics when delivering stimuli to the ear and measuring otoacoustic emissions. However, the ear canal is inherently non-uniform and terminated at an oblique angle by the conical-shaped tympanic membrane (TM), thus potentially confounding the ability of WAI quantities in characterizing the middle-ear status. This paper studies the isolated possible confounding effects of TM orientation and shape on characterizing the middle ear using WAI in human ears. That is, the non-uniform geometry of the ear canal is not considered except for that resulting from the TM orientation and shape. This is achieved using finite-element models of uniform ear canals terminated by both lumped-element and finite-element middle-ear models. In addition, the effects on stimulation and reverse-transmission quantities are investigated, including the physical significance of quantities seeking to approximate the sound pressure at the TM. The results show a relatively small effect of the TM orientation on WAI quantities, except for a distinct delay above 10 kHz, further affecting some stimulation and reverse-transmission quantities.


Assuntos
Meato Acústico Externo , Análise de Elementos Finitos , Pressão , Membrana Timpânica , Humanos , Membrana Timpânica/fisiologia , Meato Acústico Externo/fisiologia , Som , Acústica , Estimulação Acústica , Simulação por Computador , Modelos Anatômicos , Emissões Otoacústicas Espontâneas/fisiologia , Orelha Média/fisiologia , Testes de Impedância Acústica/métodos
5.
Artigo em Chinês | MEDLINE | ID: mdl-38563167

RESUMO

Objective:To study the characteristics of Mismatch negativity(MMN) in normal hearing patients of different ages, and to compare the MMN of normal hearing subjects at different ages to explore the differences in MMN between different ages. Methods:MMN test was performed on both ears using the classic Oddball mode. A frequency of 1 000 Hz(standard stimuli) and 2 000 Hz(deviant stimuli) was used to evoked the MMN. According to different age groups: the juvenile group(7-17 years old), the youth group(18-44 years old), the middle-aged group(45-59 years old), and the elderly group(60-75 years old), with 25 cases in each group. The MMN characteristics of normal hearing subjects in different age groups were analyzed statistically and the differences between groups were compared. All subjects underwent pure tone threshold test, tympanic reactance test and ABR test before MMN test. Results:MMN waveform could be elicited from both ears of 100 subjects. Among them, the average latency of the juvenile group was(159.70±20.34) ms while the average amplitude was(4.34±2.26) µV, For the youth group, the average latency was(166.01±28.67) ms and the average amplitude was(3.70±2.28) µV. Then in the middle-aged group, the average latency was(175.16±37.24) ms, meanwhile, the average amplitude was(2.69±0.84) µV. Finally, the elderly group has an average latency of(178.03±14.37) ms and an average amplitude of(2.11±0.70) µV. Therefore, there was no statistical difference in latency and amplitude between all groups(P>0.05), and there was no statistical difference in latency and amplitude between left and right ears among all subjects as a whole(P>0.05). However, when the left and right ears of all groups were compared, it was found that the latency between the left and right ears of the Juvenile group had statistical significance(P<0.05), and the amplitude difference was not statistically significant(P>0.05), while the latency and amplitude differences between the left and right ears of other groups had no statistical significance(P>0.05). There were also no significant differences in latency and amplitude between men and women(P>0.05). Conclusion:There was no statistically significant difference in the latency and amplitude of mismatched negative among normal hearing subjects of different ages, and no statistically significant difference in the MMN latency and amplitude between the left and right ears of subjects and between men and women. Therefore, the study inferred that the auditory cerebral cortex of subjects aged 7-75 years old maintained a stable state for a long time after maturity, and the latency and amplitude of mismatched negative waves were relatively stable. It is not affected by age, gender and ear side, and can stably reflect the auditory cortex function of the subjects. It has broad application prospects in clinical practice, and provides a reliable detection means for future research on the changes of the auditory cerebral cortex of patients, which is worthy of our further research and clinical promotion.


Assuntos
Córtex Auditivo , Audição , Masculino , Pessoa de Meia-Idade , Idoso , Adolescente , Humanos , Feminino , Criança , Adulto Jovem , Adulto , Audição/fisiologia , Orelha Média , Potenciais Evocados Auditivos/fisiologia , Estimulação Acústica
6.
Artigo em Chinês | MEDLINE | ID: mdl-38563177

RESUMO

Objective:To investigate the clinical features of patients with congenitally enlarged bony portions of the Eustachian tube(ET). Methods:The medical history, physical examination, hearing test, temporal bone high resolution computed tomography(HRCT) of six patients(nine ears) with congenitally enlarged bony portion of the ET were retrospectively analyzed. Results:Four patients were men and two were women. The minimum, maximum, and average ages were 5, 21, and(14.7±6.4) years, respectively. Three malformations were bilateral and three were left-sided. Three ears had conductive hearing loss(average bone and air conduction thresholds were 13.7 dB and 71.3 dB), three had mixed hearing loss(average bone and air conduction thresholds were 27.7 dB and 83.7 dB), and one had extremely severe sensorineural hearing loss. The average maximum length and width of the enlarged bony ET on temporal bone HRCT were(22.61±2.94) mm and(6.50±2.33) mm, respectively. The enlargement was combined with an external auditory canal malformation in six ears, narrow tympanic cavity in six, tympanic antrum malformation in five, ossicular chain malformation in seven, cochlear malformation in six, helicotrema malformation in three, vestibule widening in two, semicircular canal malformation in three, vestibular window malformation in six, facial nerve abnormality in five, internal auditory meatus malformation in two, low middle cranial fossa in eight, and severe internal carotid artery malformation in one. Conclusion:Bony ET enlargement is a rare congenital middle ear malformation which could combined with other ear malformations. Patients can have no ET dysfunction but different patterns of hearing loss. The defect is usually found unintentionally during imaging, and the HRCT of temporal bone is significant.


Assuntos
Surdez , Tuba Auditiva , Perda Auditiva Neurossensorial , Vestíbulo do Labirinto , Masculino , Humanos , Feminino , Tuba Auditiva/diagnóstico por imagem , Estudos Retrospectivos , Orelha Média/cirurgia , Perda Auditiva Neurossensorial/diagnóstico
7.
Nature ; 628(8008): 576-581, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38570677

RESUMO

The dual jaw joint of Morganucodon1,2 consists of the dentary-squamosal joint laterally and the articular-quadrate one medially. The articular-quadrate joint and its associated post-dentary bones constitute the precursor of the mammalian middle ear. Fossils documenting the transition from such a precursor to the mammalian middle ear are poor, resulting in inconsistent interpretations of this hallmark apparatus in the earliest stage of mammaliaform evolution1-5. Here we report mandibular middle ears from two Jurassic mammaliaforms: a new morganucodontan-like species and a pseudotribosphenic shuotheriid species6. The morganucodontan-like species shows many previously unknown post-dentary bone morphologies1,2 and exhibits features that suggest a loss of load-bearing function in its articular-quadrate joint. The middle ear of the shuotheriid approaches the mammalian condition in that it has features that are suitable for an exclusively auditory function, although the post-dentary bones are still attached to the dentary. With size reduction of the jaw-joint bones, the quadrate shifts medially at different degrees in relation to the articular in the two mammaliaforms. These changes provide evidence of a gradual loss of load-bearing function in the articular-quadrate jaw joint-a prerequisite for the detachment of the post-dentary bones from the dentary7-12 and the eventual breakdown of the Meckel's cartilage13-15 during the evolution of mammaliaforms.


Assuntos
Evolução Biológica , Orelha Média , Fósseis , Arcada Osseodentária , Mamíferos , Articulação Temporomandibular , Animais , Orelha Média/anatomia & histologia , Arcada Osseodentária/anatomia & histologia , Mamíferos/anatomia & histologia , Mamíferos/classificação , Mandíbula/anatomia & histologia , Articulação Temporomandibular/anatomia & histologia
9.
PLoS One ; 19(4): e0298535, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598472

RESUMO

Elephants have a unique auditory system that is larger than any other terrestrial mammal. To quantify the impact of larger middle ear (ME) structures, we measured 3D ossicular motion and ME sound transmission in cadaveric temporal bones from both African and Asian elephants in response to air-conducted (AC) tonal pressure stimuli presented in the ear canal (PEC). Results were compared to similar measurements in humans. Velocities of the umbo (VU) and stapes (VST) were measured using a 3D laser Doppler vibrometer in the 7-13,000 Hz frequency range, stapes velocity serving as a measure of energy entering the cochlea-a proxy for hearing sensitivity. Below the elephant ME resonance frequency of about 300 Hz, the magnitude of VU/PEC was an order of magnitude greater than in human, and the magnitude of VST/PEC was 5x greater. Phase of VST/PEC above ME resonance indicated that the group delay in elephant was approximately double that of human, which may be related to the unexpectedly high magnitudes at high frequencies. A boost in sound transmission across the incus long process and stapes near 9 kHz was also observed. We discuss factors that contribute to differences in sound transmission between these two large mammals.


Assuntos
Elefantes , Animais , Humanos , Orelha Média/fisiologia , Som , Estribo/fisiologia , Audição/fisiologia , Vibração
10.
Int J Pediatr Otorhinolaryngol ; 179: 111938, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38579403

RESUMO

INTRODUCTION: Endoscopic ossicular chain reconstruction (OCR) in adults has demonstrated equivalent outcomes to the traditional microscopic approach. Less data exist on endoscopic OCR outcomes in children, who have unique considerations including a smaller transcanal corridor and variable pathology. The purpose of this study was to investigate surgical and audiometric outcomes in children undergoing fully endoscopic and endoscopic-assisted OCR in both the short and long-term. METHODS: Retrospective review of all children (<17 years) who underwent endoscopic OCR at one tertiary care center between 2017 and 2021. Children undergoing primary and revision endoscopic OCR with either partial (PORP) and total ossicular reconstruction prostheses (TORP) were included. Children undergoing surgery for juvenile otosclerosis or congenital stapes fixation, or any child receiving a stapes prosthesis were excluded. Primary outcome measures were post-operative change in 4 frequency (500 Hz, 1, 2, 4 KHz) air conduction pure tone average (AC PTA) and change in air-bone gap (ABG). Secondary measures included need for readmission and/or revision surgery, complication rate, and surgery duration. RESULTS: Seventeen patients met inclusion criteria. Average age was 11.3 years (range, 5-17 years); 14 were male. A variety of fixed length, titanium total and partial prostheses were used. The most common prosthesis length was 2 mm (range 2-5 mm), and there were no intra- or perioperative complications. Mean long-term follow-up was 2.6 years. Most common pathology was congenital cholesteatoma (11/17, 64%), followed by chronic otitis media with tympanic membrane perforation (5/17, 29.4%), and extruded prosthesis (1/17, 5.9%). Intraoperatively, the most common finding was incus erosion (10/17, 58.8%), followed by malleus erosion (6/17, 35.3%), stapes erosion (4/17, 23.5%), and stapes absence (4/17, 23.5%). Eight children (47%) were reconstructed with PORPs, and 9 children (52.9%) were reconstructed with TORPs. Average ABG improved from 36.8 dB preoperatively to 19.9 dB postoperatively in the short-term and remained stable at 19.5 dB in the long-term. Average short-term ABG improvement was 4.2 dB for PORPs and 18 dB for TORPs. In the long-term, average ABG improved by 2.3 dB in PORPs and 13.4 dB in TORPs. PORPs had higher rates of ABG closure and lower AC PTAs than TORPs in the long-term. DISCUSSION: Endoscopic ossiculoplasty is a viable option in children presenting with ossicular erosion from various causes. Audiometric improvement following endoscopic partial and total ossicular reconstruction remains stable over time, with a preference towards partial in the long-term, and mirrors published outcomes for microscopic surgery.


Assuntos
Prótese Ossicular , Substituição Ossicular , Adulto , Humanos , Masculino , Criança , Feminino , Titânio , Implantação de Prótese , Orelha Média , Estudos Retrospectivos , Resultado do Tratamento
11.
BMC Med Educ ; 24(1): 451, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658934

RESUMO

BACKGROUND: In otosurgical training, cadaveric temporal bones are primarily used to provide a realistic tactile experience. However, using cadaveric temporal bones is challenging due to their limited availability, high cost, and potential for infection. Utilizing current three-dimensional (3D) technologies could overcome the limitations associated with cadaveric bones. This study focused on how a 3D-printed middle ear model can be used in otosurgical training. METHODS: A cadaveric temporal bone was imaged using microcomputed tomography (micro-CT) to generate a 3D model of the middle ear. The final model was printed from transparent photopolymers using a laser-based 3D printer (vat photopolymerization), yielding a 3D-printed phantom of the external ear canal and middle ear. The feasibility of this phantom for otosurgical training was evaluated through an ossiculoplasty simulation involving ten otosurgeons and ten otolaryngology-head and neck surgery (ORL-HNS) residents. The participants were tasked with drilling, scooping, and placing a 3D-printed partial ossicular replacement prosthesis (PORP). Following the simulation, a questionnaire was used to collect the participants' opinions and feedback. RESULTS: A transparent photopolymer was deemed suitable for both the middle ear phantom and PORP. The printing procedure was precise, and the anatomical landmarks were recognizable. Based on the evaluations, the phantom had realistic maneuverability, although the haptic feedback during drilling and scooping received some criticism from ORL-HNS residents. Both otosurgeons and ORL-HNS residents were optimistic about the application of these 3D-printed models as training tools. CONCLUSIONS: The 3D-printed middle ear phantom and PORP used in this study can be used for low-threshold training in the future. The integration of 3D-printed models in conventional otosurgical training holds significant promise.


Assuntos
Cadáver , Orelha Média , Modelos Anatômicos , Impressão Tridimensional , Osso Temporal , Humanos , Orelha Média/cirurgia , Osso Temporal/cirurgia , Osso Temporal/diagnóstico por imagem , Prótese Ossicular , Otolaringologia/educação , Microtomografia por Raio-X , Treinamento por Simulação , Procedimentos Cirúrgicos Otológicos/educação , Procedimentos Cirúrgicos Otológicos/instrumentação , Internato e Residência
12.
Open Vet J ; 14(3): 895-901, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38682133

RESUMO

Background: Radiographic examination of the middle ear in French bulldogs can be challenging due to their small ear cavity and thick walls. Quantifying opacity on radiographic images is required to determine normal or abnormal results. Aim: To quantify the radiographic opacity of the middle ear in French bulldogs and create a threshold for objective diagnosis. Methods: A study was conducted on 32 French Bulldogs using radiographic images. Significant difference tests were performed on the ears of patients with unilateral and bilateral middle ear filling on computed tomography. A threshold was established for detecting left-right asymmetry in the same individuals. In addition, comparisons were made between the filling and nonfilling middle ear groups to establish a threshold of pixel values that could determine single middle ear filling and nonfilling for different patient images. Results: Significant differences were observed in the left-right difference in max, left-right difference in max-ave, and left-right ratio of max-ave between unilateral and bilateral filling groups. The max-ave left-right ratio had the highest area under the curve value with a cutoff of 1.077% and 92.3% sensitivity. The item that showed a significant difference between middle ear groups with and without filling was corrected for nasopharyngeal pixel values with a cutoff of 1.028% and 85% sensitivity. Conclusion: Pixel value ratios in the middle ear region can detect asymmetries in ear densities. The max value in the region compared to the same image's nasopharyngeal region can determine the filling. Combining individual ear evaluations and symmetry improves accuracy.


Assuntos
Orelha Média , Orelha Média/diagnóstico por imagem , Masculino , Feminino , Animais , Cães , Tomografia Computadorizada por Raios X/veterinária , Doenças do Cão/diagnóstico por imagem
13.
Otolaryngol Head Neck Surg ; 170(6): 1544-1554, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38667630

RESUMO

OBJECTIVE: Convolutional neural networks (CNNs) have revolutionized medical image segmentation in recent years. This scoping review aimed to carry out a comprehensive review of the literature describing automated image segmentation of the middle ear using CNNs from computed tomography (CT) scans. DATA SOURCES: A comprehensive literature search, generated jointly with a medical librarian, was performed on Medline, Embase, Scopus, Web of Science, and Cochrane, using Medical Subject Heading terms and keywords. Databases were searched from inception to July 2023. Reference lists of included papers were also screened. REVIEW METHODS: Ten studies were included for analysis, which contained a total of 866 scans which were used in model training/testing. Thirteen different architectures were described to perform automated segmentation. The best Dice similarity coefficient (DSC) for the entire ossicular chain was 0.87 using ResNet. The highest DSC for any structure was the incus using 3D-V-Net at 0.93. The most difficult structure to segment was the stapes, with the highest DSC of 0.84 using 3D-V-Net. CONCLUSIONS: Numerous architectures have demonstrated good performance in segmenting the middle ear using CNNs. To overcome some of the difficulties in segmenting the stapes, we recommend the development of an architecture trained on cone beam CTs to provide improved spatial resolution to assist with delineating the smallest ossicle. IMPLICATIONS FOR PRACTICE: This has clinical applications for preoperative planning, diagnosis, and simulation.


Assuntos
Aprendizado Profundo , Orelha Média , Tomografia Computadorizada por Raios X , Humanos , Orelha Média/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos
14.
Sci Rep ; 14(1): 7046, 2024 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528064

RESUMO

One factor for the lacking integration of the middle ear stapes footplate prosthesis or the missing healing of stapes footplate fractures could be the known osteogenic inactivity. In contrast, it was recently demonstrated that titanium prostheses with an applied collagen matrix and immobilised growth factors stimulate osteoblastic activation and differentiation on the stapes footplate. Regarding those findings, the aim of this study was to evaluate the potential of bone regeneration including bone remodeling in the middle ear. Ten one-year-old female merino sheep underwent a middle ear surgery without implantation of middle ear prostheses or any other component for activating bone formation. Post-operatively, four fluorochromes (tetracycline, alizarin complexion, calcein green and xylenol orange) were administered by subcutaneous injection at different time points after surgery (1 day: tetracycline, 7 days: alizarin, 14 days: calcein, 28 days: xylenol). After 12 weeks, the temporal bones including the lateral skull base were extracted and histologically analyzed. Fluorescence microscopy analysis of the entire stapes with the oval niche, but in particular stapes footplate and the Crura stapedis revealed evidence of new bone formation. Calcein was detected in all and xylenol in 60% of the animals. In contrast, tetracycline and alizarin could only be verified in two animals. The authors were able to demonstrate the osseoregenerative potential of the middle ear, in particular of the stapes footplate, using fluorescence sequence labelling.


Assuntos
Antraquinonas , Fluoresceínas , Corantes Fluorescentes , Osteogênese , Xilenos , Ovinos , Feminino , Animais , Orelha Média/fisiologia , Tetraciclinas
15.
J Mech Behav Biomed Mater ; 153: 106478, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38493562

RESUMO

This study aims to introduce a novel non-invasive method for rapid material characterization of middle-ear structures, taking into consideration the invaluable insights provided by the mechanical properties of ear tissues. Valuable insights into various ear pathologies can be gleaned from the mechanical properties of ear tissues, yet conventional techniques for assessing these properties often entail invasive procedures that preclude their use on living patients. In this study, in the first step, we developed machine-learning models of the middle ear to predict its responses with a significantly lower computational cost in comparison to finite-element models. Leveraging findings from prior research, we focused on the most influential model parameters: the Young's modulus and thickness of the tympanic membrane and the Young's modulus of the stapedial annular ligament. The eXtreme Gradient Boosting (XGBoost) method was implemented for creating the machine-learning models. Subsequently, we combined the created machine-learning models with Bayesian optimization (BoTorch) for fast and efficient estimation of the Young's moduli of the tympanic membrane and the stapedial annular ligament. We demonstrate that the resultant surrogate models can fairly represent the vibrational responses of the umbo, stapes footplate, and vibration patterns of the tympanic membrane at most frequencies. Also, our proposed material characterization approach successfully estimated the Young's moduli of the tympanic membrane and stapedial annular ligament (separately and simultaneously) with values of mean absolute percentage error of less than 7%. The remarkable accuracy achieved through the proposed material characterization method underscores its potential for eventual clinical applications of estimating mechanical properties of the middle-ear structures for diagnostic purposes.


Assuntos
Orelha Média , Membrana Timpânica , Humanos , Teorema de Bayes , Orelha Média/fisiologia , Vibração , Módulo de Elasticidade , Análise de Elementos Finitos
16.
Vestn Otorinolaringol ; 89(1): 32-36, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38506023

RESUMO

Nowadays, the incidence of tuberculosis remains high all over the world, despite the vaccination, medical support, social policy. The main reasons for this are the high level of migration, the prevalence of bad habits, the prevalence of immunodeficiency conditions, the formation of resistance to antimicrobial drugs, the tendency to refuse vaccination. At the same time, great difficulties arise in the diagnosis of extrapulmonary forms of infection. The purpose of this publication is to remind about the peculiarities of the course and diagnosis of tuberculous otitis media. According to the literature, the main characteristic features of tuberculous of the middle ear are prolonged suppuration without pronounced pain syndrome, inefficiency of standard antibacterial therapy, the anamnestic data about contacts or violation of the vaccination schedule, multiple perforations and a pronounced granulation process during otoscopy, a pronounced destructive process in the temporal bone during X-ray examination. The article presents a clinical case of the development of tuberculous otitis media in a young child with delayed diagnostics and the development of mastoiditis with required emergency surgical treatment. Verification of the etiology of the disease and the specific treatment carried out made it possible to achieve complete relief of ear symptoms, restoration of the tympanic membrane and ventilation of the middle ear.


Assuntos
Mastoidite , Otite Média , Tuberculose , Criança , Pré-Escolar , Humanos , Otite Média/terapia , Tuberculose/diagnóstico , Tuberculose/epidemiologia , Mastoidite/diagnóstico , Orelha Média , Osso Temporal
17.
Int Tinnitus J ; 27(2): 146-153, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38507628

RESUMO

Opacification in the middle ear and mastoid region can stem from a wide range of factors. In terms of diagnostic imaging, CT is the primary tool due to its exceptional spatial resolution, particularly for examining the temporal bone and ossicles. MRI complements this by offering detailed soft tissue lesion characterization and assessing involvement in the inner ear and cranial nerves. This study focuses on inflammatory causes of opacification in the middle ear and mastoid, with an emphasis on the utility of CT and MRI. This comprehensive review aimed to provide a practical framework for considering potential differential diagnoses.


Assuntos
Orelha Média , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Orelha Média/diagnóstico por imagem , Orelha Média/patologia , Osso Temporal/diagnóstico por imagem , Osso Temporal/patologia , Processo Mastoide/diagnóstico por imagem , Processo Mastoide/patologia , Imageamento por Ressonância Magnética/métodos
18.
BMJ Case Rep ; 17(3)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490712

RESUMO

An obliterated Eustachian tube (ET) is a rare occurrence that can lead to chronic otitis media (OM) and aural fullness even with treatment. Our study presents a review of the literature on methods of stenting the ET. We additionally present a case of a man with mucoepidermoid carcinoma of the ET who underwent a radical nasal pharyngectomy with reconstruction and adjuvant radiation, and who had symptoms of intolerable otorrhea after tympanostomy tube placement to treat aural fullness and mucoid OM. We used a novel method of stenting the ET using a transnasal lighted guidewire catheter and steroid eluting stents placed along the entire medial ET. Previously described methods in the literature were unable to be used due to the complex middle ear anatomy filled with granulation tissue and the lack of a visible nasopharyngeal ET ostium available for straightforward placement of the stent. The procedure was successful, and postoperatively, the patient experienced decreased otorrhea.


Assuntos
Otopatias , Tuba Auditiva , Otite Média , Masculino , Humanos , Tuba Auditiva/cirurgia , Tuba Auditiva/patologia , Orelha Média , Otopatias/patologia , Stents , Catéteres , Ventilação da Orelha Média
19.
Otol Neurotol ; 45(5): 549-551, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38530353

RESUMO

OBJECTIVE: To present a method for repair of the stapedial and tensor tympani tendons in a patient with hyperacusis after a tendon lysis procedure. PATIENTS: A 71-year-old professional musician who presented to clinic with debilitating hyperacusis following a tensor tympani and stapedial tendon lysis procedure to treat middle ear myoclonus. INTERVENTIONS: A novel procedure for reapproximation of the tensor tympani and stapedial tendons into their native insertion points using periosteal grafts and nitinol wire. MAIN OUTCOMES MEASURES: Stapedial reflex measurements, uncomfortable loudness level, and subjective patient experience. RESULTS: Postoperatively, the patient had objective improvement in hyperacusis with return of acoustic reflexes in the affected ear and durable improvements in their frequency-specific uncomfortable loudness levels. CONCLUSIONS: This case describes the debilitating complication of hyperacusis following tendon lysis and highlights the importance of maximizing behavioral and medical measures prior to undergoing surgical intervention for middle ear myoclonus.


Assuntos
Hiperacusia , Mioclonia , Tensor de Tímpano , Humanos , Idoso , Hiperacusia/cirurgia , Tensor de Tímpano/cirurgia , Mioclonia/etiologia , Mioclonia/cirurgia , Complicações Pós-Operatórias/etiologia , Masculino , Orelha Média/cirurgia , Tendões/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Resultado do Tratamento
20.
Otol Neurotol ; 45(4): e333-e336, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38478411

RESUMO

OBJECTIVE: Tophaceous lesions of the middle ear from calcium pyrophosphate deposition disease (CPPD, or pseudogout) and gout are infrequently reported. Recognizing its characteristic findings will allow clinicians to accurately narrow the differential diagnosis of bony-appearing middle ear lesions and improve management. PATIENTS: Two consecutive cases of tophaceous middle ear lesions presenting to a tertiary care center between January 2021 and December 2021. Neither with previous rheumatologic history. INTERVENTIONS: Surgical excision of tophaceous middle ear lesions. MAIN OUTCOME MEASURE: Improvements in facial weakness and conductive hearing loss. RESULTS: The first case was a 66-year-old gentleman with progressive conductive loss, ipsilateral progressive facial weakness over years, and an opaque, irregular-appearing tympanic membrane anterior to the malleus found to have CPPD on surgical pathology, with immediate postoperative improvement of facial function. The second was a 75-year-old gentleman with progressive conductive loss and similar appearing tympanic membrane as case 1, previously diagnosed with tympanosclerosis, found to have gout on surgical pathology. In both cases, the CT showed a heterogenous, bony-appearing lesion in the middle ear, and both tophaceous lesions were a of gritty, chalky consistency intraoperatively. CONCLUSION: Tophaceous lesions of the middle ear are rare but have similar findings. Notably, the tympanic membrane can appear opaque and irregular, and the CT demonstrates a radiopaque, heterogeneous appearance. Facial weakness is an unusual finding. Specimens of suspected tophi must be sent to pathology without formalin for accurate diagnosis.


Assuntos
Condrocalcinose , Paralisia Facial , Gota , Masculino , Humanos , Idoso , Orelha Média/diagnóstico por imagem , Orelha Média/cirurgia , Orelha Média/patologia , Membrana Timpânica/patologia , Gota/diagnóstico , Gota/patologia , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/diagnóstico , Paralisia Facial/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...