Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.945
Filtrar
1.
Opt Lett ; 49(10): 2637-2640, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748124

RESUMO

Optical-resolution photoacoustic microscopy (OR-PAM) excels in precisely imaging a biological tissue based on absorption contrast. However, existing OR-PAMs are confined by fixed compromises between spatial resolution and field of view (FOV), preventing the integration of large FOV and local high-resolution within one system. Here, we present a non-telecentric OR-PAM (nTC-PAM) that empowers efficient adaptation of FOV and spatial resolution to match the multi-scale requirement of diverse biological imaging. Our method allows for a large-scale transformation in FOV and even surpassing the nominal FOV of the objective with minimal marginal degradation of the lateral resolution. We demonstrate the advantage of nTC-PAM through multi-scale imaging of the leaf phantom, mouse ear, and cortex. The results reveal that nTC-PAM can switch the FOV and spatial resolution to meet the requirements of different biological tissues, such as large-scale imaging of the whole cerebral cortex and high-resolution imaging of microvascular structures in local brain regions.


Assuntos
Microscopia , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Animais , Camundongos , Microscopia/métodos , Orelha/diagnóstico por imagem , Orelha/irrigação sanguínea , Imagens de Fantasmas
2.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732771

RESUMO

Human activity recognition (HAR) technology enables continuous behavior monitoring, which is particularly valuable in healthcare. This study investigates the viability of using an ear-worn motion sensor for classifying daily activities, including lying, sitting/standing, walking, ascending stairs, descending stairs, and running. Fifty healthy participants (between 20 and 47 years old) engaged in these activities while under monitoring. Various machine learning algorithms, ranging from interpretable shallow models to state-of-the-art deep learning approaches designed for HAR (i.e., DeepConvLSTM and ConvTransformer), were employed for classification. The results demonstrate the ear sensor's efficacy, with deep learning models achieving a 98% accuracy rate of classification. The obtained classification models are agnostic regarding which ear the sensor is worn and robust against moderate variations in sensor orientation (e.g., due to differences in auricle anatomy), meaning no initial calibration of the sensor orientation is required. The study underscores the ear's efficacy as a suitable site for monitoring human daily activity and suggests its potential for combining HAR with in-ear vital sign monitoring. This approach offers a practical method for comprehensive health monitoring by integrating sensors in a single anatomical location. This integration facilitates individualized health assessments, with potential applications in tele-monitoring, personalized health insights, and optimizing athletic training regimes.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Adulto Jovem , Atividades Humanas , Orelha/fisiologia , Algoritmos , Atividades Cotidianas , Aprendizado de Máquina , Aprendizado Profundo , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Movimento (Física) , Caminhada/fisiologia
3.
IEEE J Transl Eng Health Med ; 12: 448-456, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765887

RESUMO

OBJECTIVE: Sleep monitoring has extensively utilized electroencephalogram (EEG) data collected from the scalp, yielding very large data repositories and well-trained analysis models. Yet, this wealth of data is lacking for emerging, less intrusive modalities, such as ear-EEG. METHODS AND PROCEDURES: The current study seeks to harness the abundance of open-source scalp EEG datasets by applying models pre-trained on data, either directly or with minimal fine-tuning; this is achieved in the context of effective sleep analysis from ear-EEG data that was recorded using a single in-ear electrode, referenced to the ipsilateral mastoid, and developed in-house as described in our previous work. Unlike previous studies, our research uniquely focuses on an older cohort (17 subjects aged 65-83, mean age 71.8 years, some with health conditions), and employs LightGBM for transfer learning, diverging from previous deep learning approaches. RESULTS: Results show that the initial accuracy of the pre-trained model on ear-EEG was 70.1%, but fine-tuning the model with ear-EEG data improved its classification accuracy to 73.7%. The fine-tuned model exhibited a statistically significant improvement (p < 0.05, dependent t-test) for 10 out of the 13 participants, as reflected by an enhanced average Cohen's kappa score (a statistical measure of inter-rater agreement for categorical items) of 0.639, indicating a stronger agreement between automated and expert classifications of sleep stages. Comparative SHAP value analysis revealed a shift in feature importance for the N3 sleep stage, underscoring the effectiveness of the fine-tuning process. CONCLUSION: Our findings underscore the potential of fine-tuning pre-trained scalp EEG models on ear-EEG data to enhance classification accuracy, particularly within an older population and using feature-based methods for transfer learning. This approach presents a promising avenue for ear-EEG analysis in sleep studies, offering new insights into the applicability of transfer learning across different populations and computational techniques. CLINICAL IMPACT: An enhanced ear-EEG method could be pivotal in remote monitoring settings, allowing for continuous, non-invasive sleep quality assessment in elderly patients with conditions like dementia or sleep apnea.


Assuntos
Eletroencefalografia , Couro Cabeludo , Humanos , Eletroencefalografia/métodos , Idoso , Couro Cabeludo/fisiologia , Idoso de 80 Anos ou mais , Masculino , Feminino , Sono/fisiologia , Processamento de Sinais Assistido por Computador , Orelha/fisiologia , Aprendizado de Máquina , Polissonografia/métodos
4.
Eur Arch Otorhinolaryngol ; 281(6): 2849-2859, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38647685

RESUMO

PURPOSE: The indications of Vibrant Soundbridge (VSB) have been expanded to include patients with conductive and mixed hearing loss due to congenital aural atresia (CAA). However, the current evidence supporting the auditory outcomes of VSB is based mainly on case reports and retrospective chart reviews. Therefore, the present systematic review aims to summarize and critically appraise the current evidence regarding the safety and effectiveness of VSB in children and adult patients with CAA. METHODS: A systematic literature search retrieved studies that evaluated the outcomes of unilateral or bilateral implantation of VSB in patients with CAA. The bibliographic search was conducted in PubMed, Scopus, EBSCO, and Cochrane Central Register of Controlled Trials (CENTRAL) databases from January 2000 to December 2022. RESULTS: Twenty-seven studies were included in the present systematic review. Overall, the speech perception after VSB was good, with a mean word recognition score (WRS) score ranging from 60 to 96.7%. The mean postoperative speech recognition threshold (SRT) after implantation ranged from 20.8 to 50 dB. The effective gain was reported in 15 studies, ranging from 31.3 to 45.5 dB. In terms of user satisfaction with VSB, the included studies showed significant improvements in the patient-reported outcomes, such as the Speech Spatial and Qualities of Hearing scale and Glasgow Hearing Aid Benefit Profile. The VSB implantation was generally safe with low incidence of postoperative complications. CONCLUSION: VSB provides significant benefits to individuals with hearing loss owing to CAA, with very good subjective outcomes and a low risk of complications.


Assuntos
Orelha , Orelha/anormalidades , Humanos , Orelha/cirurgia , Anormalidades Congênitas/cirurgia , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/congênito , Percepção da Fala , Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia
5.
Mol Genet Genomic Med ; 12(4): e2441, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618928

RESUMO

BACKGROUND: Auriculocondylar syndrome (ARCND) is a rare congenital craniofacial developmental malformation syndrome of the first and second pharyngeal arches with external ear malformation at the junction between the lobe and helix, micromaxillary malformation, and mandibular condylar hypoplasia. Four subtypes of ARCND have been described so far, that is, ARCND1 (OMIM # 602483), ARCND2 (ARCND2A, OMIM # 614669; ARCND2B, OMIM # 620458), ARCND3 (OMIM # 615706), and ARCND4 (OMIM # 620457). METHODS: This study reports a case of ARCND2 resulting from a novel pathogenic variant in the PLCB4 gene, and summarizes PLCB4 gene mutation sites and phenotypes of ARCND2. RESULTS: The proband, a 5-day-old male neonate, was referred to our hospital for respiratory distress. Micrognathia, microstomia, distinctive question mark ears, as well as mandibular condyle hypoplasia were identified. Trio-based whole-exome sequencing identified a novel missense variant of NM_001377142.1:c.1928C>T (NP_001364071.1:p.Ser643Phe) in the PLCB4 gene, which was predicted to impair the local structural stability with a result that the protein function might be affected. From a review of the literature, only 36 patients with PLCB4 gene mutations were retrieved. CONCLUSION: As with other studies examining familial cases of ARCND2, incomplete penetrance and variable expressivity were observed within different families' heterozygous mutations in PLCB4 gene. Although, motor and intellectual development are in the normal range in the vast majority of patients with ARCND2, long-term follow-up and assessment are still required.


Assuntos
Otopatias , Orelha , Micrognatismo , Humanos , Recém-Nascido , Masculino , China , Orelha/anormalidades , Fosfolipase C beta , População do Leste Asiático
6.
ACS Sens ; 9(4): 2166-2175, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38625680

RESUMO

Relying on the strong optical absorption of hemoglobin to pulsed laser energy, photoacoustic microscopy provides morphological and functional information on microvasculature label-freely. Here, we propose speckle variance photoacoustic microscopy (SV-PAM), which harnesses intrinsic imaging contrast from temporal-varied photoacoustic signals of moving red blood cells in blood vessels, for recovering three-dimension hemodynamic images down to capillary-level resolution within the microcirculatory tissue beds in vivo. Calculating the speckle variance of consecutive photoacoustic B-scan frames acquired at the same lateral position enables accurate identification of blood perfusion and occlusion, which provides interpretations of dynamic blood flow in the microvasculature, in addition to the microvascular anatomic structures. We demonstrate high-resolution hemodynamic imaging of vascular occlusion and reperfusion in the microvasculature of mice ears in vivo. The results suggest that our SV-PAM is potentially invaluable for biomedical hemodynamic investigations, for example, imaging ischemic stroke and hemorrhagic stroke.


Assuntos
Microscopia , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Animais , Camundongos , Microscopia/métodos , Hemodinâmica/fisiologia , Orelha/irrigação sanguínea , Orelha/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Eritrócitos , Microcirculação
7.
Artigo em Chinês | MEDLINE | ID: mdl-38563168

RESUMO

Objective:This study analyzed the pure tone audiometry results of the affected ear and the contralateral ear of unilateral Meniere's disease to investigate the correlation of the hearing threshold of the contralateral ear and the hearing prognosis of unilateral Meniere's disease. Methods:In this study, the follow-up data of 135 patients with unilateral Meniere's disease in Beijing Tongren Hospital were used to analyze the pure tone audiometry results of the affected and contralateral ears at the first visit and 1 year later. Results:①At the first visit, there was no statistically significant difference between the mean hearing thresholds of the affected ear in the normal hearing group and the high-frequency hearing loss group of the contralateral ear(P>0.05). ②The range of improvement of hearing thresholds in the affected ear was greater in the contralateral ear normal hearing group than in the contralateral ear high-frequency hearing loss group. In the normal hearing group of the contralateral ear, the hearing thresholds of the affected ear at 0.25 kHz(P<0.01), 0.50 kHz(P<0.01), 1.00 kHz(P<0.01), and 2.00 kHz(P<0.05) were significantly improved; and in the high-frequency hearing loss group of the contralateral ear, the hearing thresholds at 0.25 kHz(P<0.01) hearing thresholds improved significantly, and there was no significant difference between the rest of the frequencies before and after treatment(P>0.05). A consistent pattern was observed in both higher and lower age groups. ③After 1 year of follow-up, the low and mid-frequency hearing of the affected ear improved. 0.25 kHz(P<0.01), 0.50 kHz(P<0.01), 1.00 kHz(P<0.01) hearing thresholds improved significantly; 8.00 kHz hearing thresholds decreased slightly(P<0.05). Conclusion:After standardized treatment, the results of 1-year follow-up suggested that the low-frequency hearing of MD patients could be improved, but the high-frequency hearing was slightly decreased. The hearing prognosis of the affected ear with normal hearing threshold of the contralateral ear may be better.


Assuntos
Doença de Meniere , Humanos , Doença de Meniere/diagnóstico , Perda Auditiva de Alta Frequência , Orelha , Audição , Audiometria de Tons Puros , Prognóstico
8.
Orphanet J Rare Dis ; 19(1): 152, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594752

RESUMO

BACKGROUND: Microtia is a congenital ear malformation that can occur as isolated microtia or as part of a syndrome. The etiology is currently poorly understood, although there is strong evidence that genetics has a role in the occurrence of microtia. This systematic review aimed to determine the genes involved and the abnormalities in microtia patients' head and neck regions. METHODS: We used seven search engines to search all known literature on the genetic and phenotypic variables associated with the development or outcome of microtia. The identified publications were screened and selected based on inclusion and exclusion criteria and assessed for methodological quality using the Joanna Briggs Institute (JBI) critical appraisal tools. We found 40 papers in this systematic review with phenotypic data in microtia involving 1459 patients and 30 articles containing genetic data involved in microtia. RESULT: The most common accompanying phenotype of all microtia patients was external ear canal atresia, while the most common head and neck abnormalities were the auricular, mental, and oral regions. The most common syndrome found was craniofacial microsomia syndrome. In the syndromic microtia group, the most common genes were TCOF1 (43.75%), SIX2 (4.69%), and HSPA9 (4.69%), while in the non-syndromic microtia group, the most frequently found gene was GSC exon 2 (25%), FANCB (16.67%), HOXA2 (8.33%), GSC exon 3 (8.33%), MARS1 (8.33%), and CDT1 (8.33%). CONCLUSIONS: Our systematic review shows some genes involved in the microtia development, including TCOF1, SIX2, HSPA9, GSC exon 2, FANCB, HOXA2, GSC exon 3, MARS1, and CDT1 genes. We also reveal a genotype-phenotype association in microtia. In addition, further studies with more complete and comprehensive data are needed, including patients with complete data on syndromes, phenotypes, and genotypes.


Assuntos
Microtia Congênita , Humanos , Microtia Congênita/genética , Proteínas de Homeodomínio/genética , Orelha/anormalidades , Fenótipo , Síndrome , Estudos de Associação Genética
9.
Mol Pharm ; 21(5): 2298-2314, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38527915

RESUMO

Hypertrophic scars (HS) still remain an urgent challenge in the medical community. Traditional Chinese medicine (TCM) has unique advantages in the treatment of HS. However, due to the natural barrier of the skin, it is difficult for the natural active components of TCM to more effectively penetrate the skin and exert therapeutic effects. Therefore, the development of an efficient drug delivery system to facilitate enhanced transdermal absorption of TCM becomes imperative for its clinical application. In this study, we designed a compound Salvia miltiorrhiza-Blumea balsamifera nanoemulsion gel (CSB-NEG) and investigated its therapeutic effects on rabbit HS models. The prescription of CSB-NEG was optimized by single-factor, pseudoternary phase diagram, and central composite design experiments. The results showed that the average particle size and PDI of the optimized CSB-NE were 46.0 ± 0.2 nm and 0.222 ± 0.004, respectively, and the encapsulation efficiency of total phenolic acid was 93.37 ± 2.56%. CSB-NEG demonstrated excellent stability and skin permeation in vitro and displayed a significantly enhanced ability to inhibit scar formation compared to the CSB physical mixture in vivo. After 3 weeks of CSB-NEG treatment, the scar appeared to be flat, pink, and flexible. Furthermore, this treatment also resulted in a decrease in the levels of the collagen I/III ratio and TGF-ß1 and Smad2 proteins while simultaneously promoting the growth and remodeling of microvessels. These findings suggest that CSB-NEG has the potential to effectively address the barrier properties of the skin and provide therapeutic benefits for HS, offering a new perspective for the prevention and treatment of HS.


Assuntos
Cicatriz Hipertrófica , Emulsões , Géis , Salvia miltiorrhiza , Absorção Cutânea , Coelhos , Animais , Cicatriz Hipertrófica/tratamento farmacológico , Salvia miltiorrhiza/química , Absorção Cutânea/efeitos dos fármacos , Emulsões/química , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/farmacologia , Modelos Animais de Doenças , Pele/efeitos dos fármacos , Pele/patologia , Pele/metabolismo , Administração Cutânea , Tamanho da Partícula , Masculino , Nanopartículas/química , Medicina Tradicional Chinesa/métodos , Orelha/patologia , Sistemas de Liberação de Medicamentos/métodos
10.
Vet Rec ; 194(6): e3993, 2024 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-38439116

RESUMO

BACKGROUND: Some prior evidence has suggested that lop-eared rabbits and those with brachycephalic skull conformations have a higher dental disease risk. This retrospective cohort study reports the frequency and conformational risk factors for primary-care veterinary diagnosis with dental disease in companion rabbits in the UK. METHODS: Anonymised VetCompass clinical records were manually reviewed to confirm dental disease cases. Risk factor analysis used multivariable binary logistic regression modelling. RESULTS: From 161,979 rabbits under primary veterinary care in 2019, the 1-year period prevalence of overall dental disease was 15.36% (95% confidence interval [CI]: 14.78-15.96). The prevalence of dental disease affecting incisors was 3.14% (95% CI: 2.87-3.44), and for cheek teeth it was 13.72% (95% CI: 13.17-14.29). Neither lop-eared conformation nor brachycephalic skull conformation was significantly associated with increased odds of dental disease. Dental disease odds increased as age increased and decreased as bodyweight increased. LIMITATIONS: This study retrospectively accessed clinical records, so breed names may sometimes be imprecise. CONCLUSION: The high overall prevalence of dental disease represents a major welfare concern for all companion rabbits, regardless of conformation. This information can be used to encourage regular routine dental assessment of rabbits of all conformations to promote earlier diagnosis, paying particular attention to older rabbits and those with low bodyweight.


Assuntos
Orelha , Doenças Estomatognáticas , Coelhos , Animais , Estudos Retrospectivos , Fatores de Risco , Doenças Estomatognáticas/veterinária , Reino Unido/epidemiologia
11.
S Afr J Commun Disord ; 71(1): e1-e8, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38426736

RESUMO

BACKGROUND:  Bone-conduction hearing devices (BCHD) can provide hearing solutions in settings where middle ear pathology is rife. OBJECTIVES:  Describe functional hearing outcomes and device use of children fitted with BCHD. METHOD:  Retrospective review of 79 children fitted with BCHD between January 2017 and May 2022. Outcomes included device use and subjective reports measured with the Parents' Evaluation of Aural/Oral Performance of Children (PEACH) and the Teachers' Evaluation of Aural/Oral Performance of Children (TEACH). Analysis of variance established association between mean data logging and type and degree of hearing loss. Thematic analyses were done for qualitative outcomes. RESULTS:  Average usage was 7.0 h/day (5.4 SD; range 0.1-24). PEACH ratings indicated 93.3% of children wore their BCHD 'always' or 'often', with 80% displaying Typical auditory performance at 1-month follow-up. TEACH ratings indicated 84.2% of children wore their BCHD 'always' or 'often', with 78.9% showing typical auditory behaviour. Increased usage was noted for conductive, mixed, moderate and severe hearing losses. There was a mean delay of 17.2 months (23.4 SD; range 0-90) between age of diagnosis and fitting. Thematic analyses identified two main themes: advantages and barriers to BCDH use. CONCLUSION:  Average device use fell short of the internationally recommended 10 h/day. Higher BCHD use was associated with higher functional listening performance scores. Long waiting times for medical or surgical intervention for conductive hearing losses can delay BCHD fitting.Contribution: Limited information is available to examine outcomes in children fitted with BCHD.


Assuntos
Auxiliares de Audição , Perda Auditiva , Criança , Humanos , África do Sul , Condução Óssea , Orelha , Perda Auditiva/diagnóstico , Perda Auditiva/terapia , Audição
13.
Sensors (Basel) ; 24(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38400384

RESUMO

EEG-enabled earbuds represent a promising frontier in brain activity monitoring beyond traditional laboratory testing. Their discrete form factor and proximity to the brain make them the ideal candidate for the first generation of discrete non-invasive brain-computer interfaces (BCIs). However, this new technology will require comprehensive characterization before we see widespread consumer and health-related usage. To address this need, we developed a validation toolkit that aims to facilitate and expand the assessment of ear-EEG devices. The first component of this toolkit is a desktop application ("EaR-P Lab") that controls several EEG validation paradigms. This application uses the Lab Streaming Layer (LSL) protocol, making it compatible with most current EEG systems. The second element of the toolkit introduces an adaptation of the phantom evaluation concept to the domain of ear-EEGs. Specifically, it utilizes 3D scans of the test subjects' ears to simulate typical EEG activity around and inside the ear, allowing for controlled assessment of different ear-EEG form factors and sensor configurations. Each of the EEG paradigms were validated using wet-electrode ear-EEG recordings and benchmarked against scalp-EEG measurements. The ear-EEG phantom was successful in acquiring performance metrics for hardware characterization, revealing differences in performance based on electrode location. This information was leveraged to optimize the electrode reference configuration, resulting in increased auditory steady-state response (ASSR) power. Through this work, an ear-EEG evaluation toolkit is made available with the intention to facilitate the systematic assessment of novel ear-EEG devices from hardware to neural signal acquisition.


Assuntos
Interfaces Cérebro-Computador , Dispositivos Eletrônicos Vestíveis , Humanos , Orelha , Encéfalo/fisiologia , Eletroencefalografia/métodos , Eletrodos
14.
Artigo em Chinês | MEDLINE | ID: mdl-38369790

RESUMO

Objective: This study aims to investigate the current application and the level of knowledge of intraoperative facial nerve monitoring among medical staff in China. Methods: A comprehensive online questionnaire was conducted among medical professionals across different regions in China from October 2022 to February 2023. The survey exclusively targeted departments specializing in otolaryngology, head and neck surgery, neurosurgery, and oral and maxillofacial surgery. The questionnaire covered various aspects including general information, intraoperative facial nerve monitoring practices, training history, indications for monitoring, parameters used during monitoring procedures, as well as factors influencing its implementation. Results: A total of 417 participants from 31 provincial, municipal, and autonomous regions were included. Intraoperative facial nerve monitoring was found to be implemented in 227 (54.4%,227/417) repondents of 53 institutions (24.9%, 53/213). The top three indications for implementing this technique were acoustic neuroma, parotid gland surgery, and modified middle ear surgery (mastoidectomy). Herein 81.1%(184/227) medical staff involved in intraoperative facial nerve monitoring had received relevant training, 57.3%(130/227)-92.1%(209/227) reported a lack of clear description regarding recording thresholds, stimulation currents/frequencies/wave widths. Conclusion: The majority of the institutions surveyed have not yet adopted intraoperative facial nerve monitoring. Furthermore, significant gaps concerning the procedure exist. It is imperative to establish standards or guidelines to promote its better development and application.


Assuntos
Traumatismos do Nervo Facial , Neuroma Acústico , Humanos , Nervo Facial/cirurgia , Nervo Facial/fisiologia , Monitorização Intraoperatória/métodos , Neuroma Acústico/cirurgia , Orelha , Inquéritos e Questionários , Traumatismos do Nervo Facial/prevenção & controle , Traumatismos do Nervo Facial/cirurgia , Eletromiografia/métodos
15.
Science ; 383(6682): 504-511, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38300999

RESUMO

Starting around 6 to 9 months of age, children begin acquiring their first words, linking spoken words to their visual counterparts. How much of this knowledge is learnable from sensory input with relatively generic learning mechanisms, and how much requires stronger inductive biases? Using longitudinal head-mounted camera recordings from one child aged 6 to 25 months, we trained a relatively generic neural network on 61 hours of correlated visual-linguistic data streams, learning feature-based representations and cross-modal associations. Our model acquires many word-referent mappings present in the child's everyday experience, enables zero-shot generalization to new visual referents, and aligns its visual and linguistic conceptual systems. These results show how critical aspects of grounded word meaning are learnable through joint representation and associative learning from one child's input.


Assuntos
Orelha , Olho , Desenvolvimento da Linguagem , Linguística , Aprendizado de Máquina Supervisionado , Criança , Humanos , Conhecimento , Redes Neurais de Computação , Gravação em Vídeo
16.
Trends Hear ; 28: 23312165231215916, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38284359

RESUMO

When presenting two competing speech stimuli, one to each ear, a right-ear advantage (REA) can often be observed, reflected in better speech recognition compared to the left ear. Considering the left-hemispheric dominance for language, the REA has been explained by superior contralateral pathways (structural models) and language-induced shifts of attention to the right (attentional models). There is some evidence that the REA becomes more pronounced, as cognitive load increases. Hence, it is interesting to investigate the REA in static (constant target talker) and dynamic (target changing pseudo-randomly) cocktail-party situations, as the latter is associated with a higher cognitive load than the former. Furthermore, previous research suggests an increasing REA, when listening becomes more perceptually challenging. The present study examined the REA by using virtual acoustics to simulate static and dynamic cocktail-party situations, with three spatially separated talkers uttering concurrent matrix sentences. Sentences were presented at low sound pressure levels or processed with a noise vocoder to increase perceptual load. Sixteen young normal-hearing adults participated in the study. The REA was assessed by means of word recognition scores and a detailed error analysis. Word recognition revealed a greater REA for the dynamic than for the static situations, compatible with the view that an increase in cognitive load results in a heightened REA. Also, the REA depended on the type of perceptual load, as indicated by a higher REA associated with vocoded compared to low-level stimuli. The results of the error analysis support both structural and attentional models of the REA.


Assuntos
Percepção da Fala , Adulto , Humanos , Estimulação Acústica , Orelha , Ruído
17.
Otol Neurotol ; 45(2): 169-175, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38206065

RESUMO

OBJECTIVES: We developed a novel keyhole surgery, named "percutaneous endoscopic ear surgery" (PEES), with the aim of further reducing the invasiveness of otologic surgery. We reported the cases we encountered and retrospectively analyzed the invasiveness of PEES. METHODS: We analyzed the ears of eight patients who underwent PEES for mastoid lesions that could not be manipulated with transcanal endoscopic ear surgery (TEES) at our hospital between July 2021 and November 2022. We performed PEES alone in three patients, including one case of type A (preauricular incision) and two cases of type B (retroauricular incision). The last five patients underwent combined endoscopic ear surgery, which is simultaneous PEES and TEES. In these cases, one patient underwent type A PEES, and four patients underwent type B PEES. RESULTS: PEES was performed in all patients without converting to conventional microscopic mastoidectomy. The mean length of skin incisions was 19.1 ± 4.5 mm, which was smaller than that in conventional mastoidectomy. In all cases, the average length of the major axis of the keyhole was <10 mm, indicating that sufficient minimally invasive surgery was achieved. The average depth from the keyhole to the deepest site was 21.6 ± 8.9 mm. There was no change in the mean hearing level before and after the surgery. CONCLUSION: PEES is a minimally invasive procedure for manipulating lesions in the mastoid. In addition, the combination of PEES and TEES is an ideal, minimally invasive procedure that can be used to treat all regions of the temporal bone.


Assuntos
Orelha , Endoscopia , Processo Mastoide , Procedimentos Cirúrgicos Minimamente Invasivos , Humanos , Processo Mastoide/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Retrospectivos , Osso Temporal , Orelha/cirurgia
18.
Sci Rep ; 14(1): 1418, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38228747

RESUMO

FLASH-radiotherapy may provide significant sparing of healthy tissue through ultra-high dose rates in protons, electrons, and x-rays while maintaining the tumor control. Key factors for the FLASH effect might be oxygen depletion, the immune system, and the irradiated blood volume, but none could be fully confirmed yet. Therefore, further investigations are necessary. We investigated the protective (tissue sparing) effect of FLASH in proton treatment using an in-vivo mouse ear model. The right ears of Balb/c mice were irradiated with 20 MeV protons at the ion microprobe SNAKE in Garching near Munich by using three dose rates (Conv = 0.06 Gy/s, Flash9 = 9.3 Gy/s and Flash930 = 930 Gy/s) at a total dose of 23 Gy or 33 Gy. The ear thickness, desquamation, and erythema combined in an inflammation score were measured for 180 days. The cytokines TGF-ß1, TNF-α, IL1α, and IL1ß were analyzed in the blood sampled in the first 4 weeks and at termination day. No differences in inflammation reactions were visible in the 23 Gy group for the different dose rates. In the 33 Gy group, the ear swelling and the inflammation score for Flash9 was reduced by (57 ± 12) % and (67 ± 17) % and for Flash930 by (40 ± 13) % and (50 ± 17) % compared to the Conv dose rate. No changes in the cytokines in the blood could be measured. However, an estimation of the irradiated blood volume demonstrates, that 100-times more blood is irradiated when using Conv compared to using Flash9 or Flash930. This indicates that blood might play a role in the underlying mechanisms in the protective effect of FLASH.


Assuntos
Neoplasias , Prótons , Animais , Camundongos , Orelha , Inflamação , Citocinas , Dosagem Radioterapêutica
19.
Ear Hear ; 45(3): 636-647, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38082489

RESUMO

OBJECTIVES: The objectives of the present study were to investigate the relationship between wideband absorbance (WBA) and air-bone gap (ABG) in children with a conductive hearing loss (CHL) due to otitis media with effusion (OME) and determine the accuracy of WBA to predict the magnitude of ABGs. DESIGN: This was a prospective, cross-sectional study involving a control group of 170 healthy ears from 130 children (mean age 7.7 years) and a CHL cohort of 181 ears from 176 children (mean age 5.9 years) with OME. The CHL cohort was divided into three groups: CHL1, CHL2, and CHL3 defined by mean ABG (averaged across 0.5 to 4 kHz) of 16 to 25 dB, 26 to 35 dB, and 36 to 45 dB, respectively. WBA was measured at frequencies from 0.25 to 8 kHz at ambient pressure. RESULTS: WBA was significantly reduced between 0.25 and 5 kHz for all CHL groups. The difference in WBA at 1 to 4 kHz between the control and CHL groups increased with increasing ABG. The predictive accuracy, as indicated by area under the receiver operating characteristic curve (AUROC) of WBA, increased with increasing ABG. The AUROC for WBA at 1.5 kHz was 0.86 for the CHL1, 0.91 for the CHL2, and 0.93 for the CHL3 group. The AUROCs for WBA averaged across 0.5 to 4 kHz were 0.88, 0.93, and 0.94 for the CHL1, CHL2, and CHL3 groups, respectively. Linear regression analyses showed significant negative correlations between WBA 0.5-4 k and ABG 0.5-4 k . The regression model (ABG 0.5-4 k = 31.83 - 24.08 × WBA 0.5-4 k ) showed that WBA 0.5-4 k predicted ABG 0.5-4 k with high accuracy. Comparison of predicted and actual WBA on a different group of subjects revealed that at an individual level, the model predicted ABG between 16 and 35 with greater precision. CONCLUSIONS: There were significant strong correlations between WBA and ABG such that WBA decreased with increasing ABG. WBA demonstrated good discrimination accuracy with AUROC exceeding 0.88 for the 0.5 to 4 kHz and 1 to 4 kHz frequency bands. The WBA test holds promise for determining the severity of CHL in children with OME.


Assuntos
Perda Auditiva Condutiva , Otite Média com Derrame , Criança , Humanos , Pré-Escolar , Perda Auditiva Condutiva/etiologia , Otite Média com Derrame/complicações , Estudos Transversais , Estudos Prospectivos , Orelha
20.
J Craniofac Surg ; 35(1): e88-e90, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37948616

RESUMO

The question mark ear is a rare abnormality characterized by a cleft between the helix and the earlobe, resulting in a protrusion of the upper part of the ear. The severity of this ear malformation can range from a minor notch in the helix to a complete separation of the helix and the earlobe. In this study, we present a case of a patient with a moderately severe right-sided unilateral question mark deformity. To address this issue, we utilized a novel technique that involves a combination of a Y-V flap with double opposing Z-plasty. Our clinical study demonstrates that using this technique for reconstructing the deformity yields excellent results in terms of the helical rim and fold contour, utilizing solely the local tissues.


Assuntos
Pavilhão Auricular , Otopatias , Orelha/anormalidades , Procedimentos de Cirurgia Plástica , Humanos , Retalhos Cirúrgicos/cirurgia , Pavilhão Auricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...