1.
Vestn Oftalmol ; 140(2): 34-39, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742496

RESUMO

PURPOSE: This study evaluates the accuracy of modern intraocular lens (IOL) calculation formulas using axial length (AL) data obtained by ultrasound biometry (UBM) compared to the third-generation SRK/T calculator. MATERIAL AND METHODS: The study included 230 patients (267 eyes) with severe lens opacities that prevented optical biometry, who underwent phacoemulsification (PE) with IOL implantation. IOL power calculation according to the SRK/T formula was based on AL and anterior chamber depth obtained by UBM (Tomey Biometer Al-100) and keratometry on the Topcon KR 8800 autorefractometer. To adapt AL for new generation calculators - Barrett Universal II (BUII), Hill RBF ver. 3.0 (RBF), Kane and Ladas Super Formula (LSF) - the retinal thickness (0.20 mm) was added to the axial length determined by UBM, and then the optical power of the artificial lens was calculated. The mean error and its modulus value were used as criteria for the accuracy of IOL calculation. RESULTS: A significant difference (p=0.008) in the mean IOL calculation error was found between the formulas. Pairwise analysis revealed differences between SRK/T (-0.32±0.58 D) and other formulas - BUII (-0.16±0.52 D; p=0.014), RBF (-0.17±0.51 D; p=0.024), Kane (-0.17±0.52 D; p=0.029), but not with the LSF calculator (-0.19±0.53 D; p=0.071). No significant differences between the formulas were found in terms of mean error modulus (p=0.238). New generation calculators showed a more frequent success in hitting target refraction (within ±1.00 D in more than 95% of cases) than the SRK/T formula (86%). CONCLUSION: The proposed method of adding 0.20 mm to the AL determined by UBM allows using this parameter in modern IOL calculation formulas and improving the refractive results of PE, especially in eyes with non-standard anterior segment structure.


Assuntos
Biometria , Lentes Intraoculares , Facoemulsificação , Refração Ocular , Humanos , Biometria/métodos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Refração Ocular/fisiologia , Facoemulsificação/métodos , Comprimento Axial do Olho/diagnóstico por imagem , Implante de Lente Intraocular/métodos , Catarata/fisiopatologia , Catarata/diagnóstico , Óptica e Fotônica/métodos , Microscopia Acústica/métodos
2.
Vestn Oftalmol ; 140(2): 24-32, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742495

RESUMO

PURPOSE: This study was conducted to develop a new optimized phacoemulsification technique for Morgagnian cataract taking into account the anatomical and topographic parameters of the lens nucleus. MATERIAL AND METHODS: A working classification of Morgagnian cataract was developed based on the size of the nucleus: if the edge of the nucleus is visualized at the upper edge of the pupil or between the upper edge and the middle of the pupil, it was classified as an initial stage of Morgagnian cataract with a large nucleus; if the upper edge of the nucleus is visualized in the middle of the pupil and below, it was classified as an advanced stage of Morgagnian cataract with a small nucleus. The first group included six patients who underwent surgery using the scaffold technique with removal of the whole small nucleus into the anterior chamber. The second group included 11 patients who underwent surgery using the scaffold technique with removal of the last fragment of the nucleus into the anterior chamber. RESULTS: The use of the scaffold technique with removal of the nucleus into the anterior chamber helped reduce the number of intraoperative complications to 16.7% in the first group, compared to 27.3% in the second group, and the percentage of endothelial cell loss to 10.1% in the first group, compared to 10.7% in the second group. CONCLUSIONS: The anatomical and topographic features of the lens and the anterior segment of the eye in Morgagnian cataract with a small nucleus allow for preliminary implantation of an intraocular lens into the capsular bag to protect the posterior capsule during phacoemulsification of the nucleus with minimal mechanical, hydrodynamic and acoustic damage to the surrounding structures of the eye.


Assuntos
Catarata , Facoemulsificação , Humanos , Facoemulsificação/métodos , Catarata/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Acuidade Visual , Núcleo do Cristalino/cirurgia , Núcleo do Cristalino/patologia , Complicações Intraoperatórias/prevenção & controle , Complicações Intraoperatórias/etiologia
3.
BMC Ophthalmol ; 24(1): 212, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750496

RESUMO

BACKGROUND: To evaluate differences in log MAR best-corrected visual acuity (BCVA) improvement and postoperative central foveal thickness (CFT) and choroidal thickness (CT) changes between conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS) for high-myopia cataracts. METHODS: This was a retrospective and observational study. One hundred and two eyes of 102 patients with high-myopia cataracts were examined. CPS was performed in 54 eyes, and FLACS was performed in 48 eyes. All eyes underwent logMAR BCVA, CFT and CT of three different sectors preoperatively and one week and six months postoperatively. RESULTS: The logMAR BCVA improved significantly after surgery in both groups (both P < 0.001), but no difference was observed in BCVA improvement between the groups (P = 0.554). Moreover, no significant differences were reflected in the changes in CFT, nasal 1 mm CT or temporal 1 mm CT between the two groups, and only subfoveal choroidal thickness (SFCT) in the CPS group decreased significantly compared with that in the FLACS group at any postoperative time (P = 0.003 and 0.026). AL, preoperative logMAR BCVA, and CT of the three regions exhibited a notable correlation with postoperative BCVA (all P < 0.05) according to univariate logistic regression analysis. However, only the AL, preoperative logMAR BCVA and SFCT remained significant in the multivariate model. Postoperative logMAR BCVA revealed a positive correlation with AL and preoperative logMAR BCVA but a negative correlation with SFCT. CONCLUSIONS: FLACS was not superior to CPS in improving BCVA but had less impact on SFCT in the treatment of high-myopia cataracts. Eyes with a longer AL, worse preoperative logMAR BCVA and thinner SFCT had a high risk of worse postoperative BCVA.


Assuntos
Catarata , Terapia a Laser , Facoemulsificação , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Estudos Retrospectivos , Feminino , Masculino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Idoso , Terapia a Laser/métodos , Catarata/complicações , Catarata/fisiopatologia , Tomografia de Coerência Óptica/métodos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Extração de Catarata/métodos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Corioide/diagnóstico por imagem , Resultado do Tratamento
4.
Int Ophthalmol ; 44(1): 211, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696090

RESUMO

PURPOSE: To evaluate the effects of sodium hyaluronate drops on dry eye parameters and corneal epithelial thickness following cataract surgery. METHODS: The study included 84 patients who underwent uncomplicated phacoemulsification. In Group A, 0.15% sodium hyaluronate drops were added to the postoperative antibiotic/anti-inflammatory treatment. In Group B, only antibiotic/anti-inflammatory treatment was applied. Preoperatively and at 1 week and 1 month postoperatively, all the patients were evaluated in respect of tear break-up time (TBUT), the Schirmer test under anesthesia, the corneal fluorescein staining (CFS) score, mean central corneal thickness (CCT) and mean central corneal epithelial thickness (CCET), and the two groups were compared. RESULTS: A statistically significant difference was determined between the two groups at postoperative 1 month in respect of TBUT, Schirmer test, CFS score, and CCET (p < 0.01). In Group A, a statistically significant increase was determined in the TBUT and Schirmer values at 1 month postoperatively (p < 0.01, p = 0.01, respectively) and in Group B, these values were decreased compared to preoperatively (p < 0.01). The CCET was determined to be significantly thinner in Group B 1 month postoperatively (p < 0.01). A significant increase in CCT was observed in both groups at postoperative 1 week (p < 0.01) and preoperative values were reached at 1 month postoperatively. CONCLUSION: In the patient group using sodium hyaluronate, significant differences were determined in all dry eye parameters and CCET. The use of hyaluronate sodium drops after cataract surgery was seen to improve dry eye parameters and contribute to a healthy ocular surface by ensuring continuity of the corneal epithelium.


Assuntos
Síndromes do Olho Seco , Epitélio Corneano , Ácido Hialurônico , Soluções Oftálmicas , Facoemulsificação , Humanos , Ácido Hialurônico/administração & dosagem , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/diagnóstico , Feminino , Masculino , Idoso , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Pessoa de Meia-Idade , Soluções Oftálmicas/administração & dosagem , Facoemulsificação/métodos , Viscossuplementos/administração & dosagem , Estudos Prospectivos , Lágrimas/metabolismo , Complicações Pós-Operatórias/prevenção & controle , Extração de Catarata/métodos
5.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717085

RESUMO

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Assuntos
Pressão Intraocular , Implante de Lente Intraocular , Facoemulsificação , Acuidade Visual , Humanos , Estudos Prospectivos , Pressão Intraocular/fisiologia , Masculino , Feminino , Idoso , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Endotélio Corneano/patologia , Contagem de Células , Período Pós-Operatório , Tomografia de Coerência Óptica , Hidrodinâmica , Câmara Anterior , Período Intraoperatório
6.
BMC Ophthalmol ; 24(1): 206, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711059

RESUMO

PURPOSE: The main objective is to quantify the lens nuclear opacity using spectral-domain optical coherence tomography (SD-OCT) and to evaluate its association with Lens Opacities Classification System III (LOCS-III) system, lens thickness (LT), and surgical parameters. The secondary objective is to assess the diagnostic model performance for hard nuclear cataract. METHODS: This study included 70 eyes of 57 adults with cataract, with 49 (70%) and 21 (30%) in training and validation cohort, respectively. Correlations of the average nuclear density (AND) /maximum nuclear density (MND) with LOCS-III scores, LT, and surgical parameters were analyzed. Univariate and multivariate logistic regression analysis, receiver operating characteristic curves and calibration curves were performed for the diagnostic of hard nuclear cataract. RESULTS: The pre-operative uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), mean axial length (AL), and LT were 1.20 ± 0.47 log MAR, 15.50 ± 2.87 mmHg, 27.34 ± 3.77 mm and 4.32 ± 0.45 mm, respectively. The average nuclear opalescence (NO) and nuclear colour (NC) scores were 3.61 ± 0.94 and 3.50 ± 0.91 (ranging from 1.00 to 6.90), respectively. The average AND and MND were 137.94 ± 17.01 and 230.01 ± 8.91, respectively. NC and NO scores both significantly correlated with the AND (rNC = 0.733, p = 0.000; rNO = 0.755, p = 0.000) and MND (rNC = 0.643, p = 0.000; rNO = 0.634, p = 0.000). In the training cohort, the area under the curve (AUC) of the model was 0.769 (P < 0.001, 95%CI 0.620-0.919), which had a good degree of differentiation (Fig. 2a). The calibration curve showed good agreement between predicted and actual probability. CONCLUSION: The nuclear density measurement on SD-OCT images can serve as an objective and reliable indicator for quantifying nuclear density.


Assuntos
Catarata , Núcleo do Cristalino , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Catarata/diagnóstico , Idoso , Pessoa de Meia-Idade , Núcleo do Cristalino/patologia , Núcleo do Cristalino/diagnóstico por imagem , Acuidade Visual/fisiologia , Curva ROC , Estudos Retrospectivos , Facoemulsificação , Idoso de 80 Anos ou mais , Adulto , Cristalino/diagnóstico por imagem , Cristalino/patologia
7.
Ulster Med J ; 93(1): 12-17, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38707980

RESUMO

Background: The practice of immediate sequential bilateral cataract surgery (ISBCS) was more widely adopted in the UK during the COVID-19 pandemic, in response to limited surgical capacity and the risk of nosocomial infection. This study reports on a single site experience of ISBCS in Northern Ireland. Methods: Data was collected prospectively between 17th November 2020 and 30th November 2021. The ISBCS surgical protocol, recommended by RCOphth and UKISCRS, was followed. Primary outcomes measures were: postoperative visual acuity (VA), refractive prediction accuracy, intraoperative and postoperative complications. Results: Of 41 patients scheduled, 39 patients completed ISBCS and two patients underwent unilateral surgery (n=80 eyes). Mean age at the time of surgery was 71.6 years (standard deviation (SD) ±11.8 years). Median preoperative VA was 0.8 logMAR (range: PL to 0.2 logMAR). Seventeen (20.9%) eyes were highly myopic and 9 (11.1%) eyes were highly hypermetropic. Median cumulative dissipated phacoemulsification energy was 15.7 sec (range: 1.8 sec to 83.4 sec). Median case time was 10.4 min (range: 4.3 min to 37.1 min).One eye (1.3%) developed iritis secondary to a retained tiny cortical fragment. Four eyes (5.0%, n=3 patients) developed cystoid macular oedema, with full resolution. On wide field imaging, an asymptomatic unilateral peripheral suprachoroidal haemorrhage was noted in two highly myopic patients (axial lengths of 27.01mm and 25.05mm respectively). The posterior pole was spared, and both resolved spontaneously without any visual impairment. Conclusions: In our initial experience, ISBCS was found to be a safe approach to cataract surgery. Our patient cohort included eyes with dense cataracts and high ametropia. Further studies are required to assess patient reported outcome measures and the possible economic benefits of ISBCS in our local population.


Assuntos
COVID-19 , Extração de Catarata , Acuidade Visual , Humanos , COVID-19/epidemiologia , Idoso , Masculino , Feminino , Extração de Catarata/métodos , Pessoa de Meia-Idade , Irlanda do Norte/epidemiologia , Estudos Prospectivos , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , SARS-CoV-2 , Facoemulsificação/métodos , Facoemulsificação/efeitos adversos , Pandemias
8.
Vestn Oftalmol ; 140(2. Vyp. 2): 123-128, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739141

RESUMO

Effective and atraumatic removal of a soft lens nucleus requires different surgical techniques compared to phacoemulsification of a dense nucleus. PURPOSE: This study was conducted to develop a non-ultrasound technique for emulsification of a soft lens nucleus. MATERIAL AND METHODS: Fifty-seven patients (57 eyes) underwent surgery. In 23 cases, early or immature cataracts were detected, and in 34 cases, lens removal was performed for refractive purposes in high myopia and complex myopic astigmatism. Phacoemulsifier Centurion Vision System (Alcon Laboratories, Inc., USA) was used for the surgery. Aspiration of soft lens nucleus was done using a rotational technique. The following aspects were evaluated in the course of the surgery: the volume of the required irrigation solution, and the frequency needing to involve ultrasound for complete emulsification of the lens nucleus. Intraoperative and postoperative complications were also assessed. RESULTS: The surgery was uneventful in all cases. There were no violations of the integrity of capsulorhexis edge. The need for short pulses of minimal power ultrasound during the removal of the soft lens using this technique arose only in 11 (19.3%) cases. The effective ultrasound time was less than 1 second. The required volume of irrigation solution was 33.0 (24.0; 43.0) ml, which does not differ significantly from that in ultrasonic phacoemulsification. CONCLUSIONS: The use of modern phacoemulsifiers providing a high vacuum level allows successful removal of a soft lens without using ultrasound, which prevents its negative impact on the ocular tissues. The use of adequate surgical techniques, including the optimal direction of rotation of the lens nucleus in the rotational technique, improves the efficiency of soft lens nucleus removal.


Assuntos
Facoemulsificação , Humanos , Masculino , Feminino , Facoemulsificação/métodos , Pessoa de Meia-Idade , Catarata , Resultado do Tratamento , Núcleo do Cristalino/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Idoso
9.
Vestn Oftalmol ; 140(2. Vyp. 2): 129-135, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739142

RESUMO

The influence of various patterns of preliminary femtosecond laser-assisted fragmentation of the lens nucleus on the energy and hydrodynamic parameters of phacoemulsification remains insufficiently studied. PURPOSE: This study evaluates the influence of various patterns of preliminary femtosecond laser-assisted fragmentation of the lens nucleus on the energy, hydrodynamic parameters of phacoemulsification, and the degree of corneal endothelial cell loss. MATERIAL AND METHODS: Hybrid phacoemulsification was performed in 336 patients (336 eyes) with grade IV immature cataract according to the Buratto classification in three age-matched groups. Group 1 included 103 patients (103 eyes) who underwent hybrid phacoemulsification with preliminary femtosecond laser-assisted fragmentation of the nucleus with a «pizza¼ pattern (division of the nucleus with 10 radial cuts). Group 2 included 112 patients (112 eyes) who underwent femtosecond laser-assisted fragmentation of the nucleus with a «cylinders¼ pattern (division of the nucleus with 8 radial cuts in combination with 5 circular cuts). Group 3 included 121 patients (121 eyes) who underwent femtosecond laser-assisted fragmentation of the nucleus with a «grid¼ pattern (division of the nucleus with 8 radial cuts in combination with multiple mutually perpendicular cuts in the central zone in the form of a grid with a 0.5 mm cell). Effective ultrasound time and the volume of irrigation solution for emulsification of the lens nucleus fragments were determined during the operation. The loss of corneal endothelial cells was assessed 3 months after surgery. RESULTS: The minimum effective ultrasound time was noted after using the "grid" pattern - 4.05 (2.88; 4.74) s, which was significantly less than with the "cylinders" pattern - 4.97 (3.78; 5.88) s and the "pizza" pattern - 6.15 (4.52; 7.75) s (p<0.05). The effective ultrasound time when using the "cylinders" pattern was significantly less than with the "pizza" pattern (p<0.05). The volume of irrigation solution used for emulsification of the lens nucleus fragments was significantly less in the "grid" pattern - 41.5 (33.5; 49.5) ml compared to the "cylinders" patterns 58.5 (51.0; 66.0), p<0.05 and "pizza" pattern 75.0 (66.0; 83.5), p<0.01. The volume of irrigation solution when using the "cylinders" pattern was significantly less than when using the "pizza" pattern (p<0.05). The loss of corneal endothelial cells after using the "grid" pattern was 8.82 (7.59; 9.87)%, which was significantly less than after the "cylinders" patterns - 9.97 (8.81; 10.83)%, p<0.05 and "pizza" - 11.70 (10.62; 12.97)%, p<0.05. At the same time, the loss of endothelial cells after using the "cylinders" pattern was significantly less than after the "pizza" pattern (p<0.05). CONCLUSIONS: The choice of the optimal pattern of preliminary femtosecond laser-assisted fragmentation of the lens nucleus provides a significant decrease in the energy and hydrodynamic parameters of phacoemulsification and, accordingly, the loss of corneal endothelial cells.


Assuntos
Catarata , Hidrodinâmica , Terapia a Laser , Núcleo do Cristalino , Facoemulsificação , Humanos , Facoemulsificação/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Núcleo do Cristalino/cirurgia , Catarata/diagnóstico , Terapia a Laser/métodos , Resultado do Tratamento , Idoso , Acuidade Visual
10.
Vestn Oftalmol ; 140(2. Vyp. 2): 109-115, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739139

RESUMO

Fragmentation and aspiration of soft cataracts require different surgical techniques and approaches compared to the removal of dense nuclei, including when using a femtosecond laser. PURPOSE: This study was conducted to develop a non-ultrasound technique for aspiration of a soft lens nucleus after its preliminary femtosecond laser-assisted fragmentation. MATERIAL AND METHODS: The study included 63 patients (63 eyes) aged 23 to 40 years who underwent surgery. In 27 cases, early or immature cataract was observed, and in 36 cases, cataract removal was performed for refractive purposes in high myopia and complex myopic astigmatism. The VICTUS femtosecond laser surgical system (Technolas Perfect Vision GmbH, Germany) was used for preliminary fragmentation of the lens nucleus. Surgeries were performed using the Centurion Vision System phacoemulsifier (Alcon Laboratories, Inc., USA). The volume of the required irrigation solution was evaluated during the surgery. Intraoperative and postoperative complications were assessed. RESULTS: The surgery was performed without complications in all cases. Capsulorhexis edge was completely preserved along its entire circumference. The study showed the fundamental possibility of aspirating a cataract with a nucleus of grade I-II density without low-frequency ultrasound after preliminary femtosecond laser-assisted fragmentation of the nucleus with a "grid" pattern, which ensures minimal fragment size in the central zone of the nucleus. The volume of irrigation solution required for aspiration of the nucleus was 36.0 (27.0; 44.0) ml, which does not significantly differ from the volume of solution during ultrasound phacoemulsification of a nucleus of such density. CONCLUSIONS: Femtosecond laser-assisted fragmentation of the lens nucleus with a "grid" pattern and phacoemulsifier systems with a high vacuum level allow effective aspiration of a soft lens without using low-frequency ultrasound.


Assuntos
Facoemulsificação , Humanos , Adulto , Masculino , Feminino , Facoemulsificação/métodos , Terapia a Laser/métodos , Catarata , Resultado do Tratamento , Núcleo do Cristalino/cirurgia , Sucção/métodos , Acuidade Visual
11.
BMC Ophthalmol ; 24(1): 210, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741065

RESUMO

BACKGROUND: Parry-Romberg syndrome (PRS) is a rare progressive degenerative disorder of unknown etiology. Here we report a rare case of PRS combined with lens subluxation in Eye and ENT hospital of Fudan University, Shanghai. To our knowledge, it is the first reported case of PRS combined with lens subluxation that has been managed surgically with phacoemulsification and CTR placement and IOL implantation in Shanghai. CASE PRESENTATION: A 60-year-old woman was referred for "right visual blur for 2 years" and had persistent right facial paralysis of unknown etiology since the age 12. She had right facial muscle atrophy and paralysis. Eye examination also showed the right eyelid pseudoptosis, enophthalmos, age-related cataract combined with lens subluxation existed in the right eye. The patient was diagnosed as age-related cataract and lens subluxation in the right eye and progressive hemifacial atrophy (Parry-Romberg syndrome). We conducted a combined phacoemulsification, IOL and CTR implantation and pupilloplasty surgery for the patient under general anesthesia and the postoperative UCVA was 20/30 and remained for 1 year's follow up. CONCLUSIONS: Here we reported a rare case of PHA combined with lens subluxation in China. After appropriate eye surgery, the patient achieved satisfying vision result in the right eye.


Assuntos
Hemiatrofia Facial , Subluxação do Cristalino , Facoemulsificação , Humanos , Feminino , Hemiatrofia Facial/complicações , Hemiatrofia Facial/diagnóstico , Hemiatrofia Facial/cirurgia , Pessoa de Meia-Idade , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/etiologia , Implante de Lente Intraocular , Acuidade Visual/fisiologia
12.
PLoS One ; 19(4): e0300148, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38593138

RESUMO

PURPOSE: To assess the association between vitreous hyper-reflective dots (VHD) and the macular thickness changes following uneventful phacoemulsification. METHODS: In this prospective cohort study optical coherence tomography (OCT) examinations were performed preoperatively and 1 week, 1 month and 3 months postoperatively in patients undergoing cataract surgery. OCT images were analyzed for retinal central subfield thickness (CST) and preretinal VHDs. Surgeries were recorded for the assessment of lens fragments in the space of Berger. RESULTS: 111 eyes of 97 patient were enrolled of whom 69 (62.2%) were female. VHDs were seen in 25 eyes (22.5%) at week 1; in 21 eyes (18.9%) at month 1 and in 3 eyes (2.7%) at month 3. In all eyes with VHDs retro-capsular lens fragments were visible immediately after phacoemulsification. The number of VHDs significantly decreased over the postoperative period. There was a moderate correlation between the number of VHDs and CST at 1 month (r = 0.426, p<0.001). In eyes with VHD the CST averaged 238.8±17.6 µm (214-266) at 1 week; 276.1±63.5 µm (231-481) at 1 month and 285.1±122.3 µm (227-785) at 3 months. In eyes with no detectable VHDs CST averaged 235.9±23.3 µm (192-311) at 1 week; 240.1±21.6 µm (200-288) at 1 month and 242.2±21.3 µm (205-289) at 3 months. Although the differences among the assessment points were relatively low, there was a significant difference in general (p<0.001, Friedman test). CONCLUSION: In conclusion, VHDs seem to cause macular thickening throughout the postoperative course. The origin of VHDs is still unknown; however, they presumably represent lens fragments that provoke subclinical inflammation.


Assuntos
Extração de Catarata , Catarata , Edema Macular , Facoemulsificação , Humanos , Feminino , Masculino , Edema Macular/etiologia , Estudos Prospectivos , Extração de Catarata/efeitos adversos , Retina , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Catarata/diagnóstico por imagem , Catarata/complicações
13.
Zhonghua Yi Xue Za Zhi ; 104(16): 1391-1396, 2024 Apr 23.
Artigo em Chinês | MEDLINE | ID: mdl-38644289

RESUMO

Objective: To explore the effects of different types of intraocular lens (IOL) implantation on patient's visual quality and function after phacoemulsification. Methods: The clinical data of patients with monocular cataract who underwent phacoemulsification in the Department of Ophthalmology, People's Hospital Affiliated to Shandong First Medical University between December 2021 and May 2023 were retrospectively analyzed. According to the types of IOL, the patients were divided into monofocal group, bifocal group and depth of focus extension group. Three months later, uncorrected distance visual acuity (UCDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), best corrected intermediate visual acuity (BCIVA), uncorrected near visual acuity (UCNVA) and best corrected near visual acuity (BCNVA) were detected. Contrast sensitivity and total wavefront aberration were measured by visual function analyzer. Satisfaction with visual quality was evaluated by hospital-made satisfaction questionnaire. Results: A total of 92 patients were included, with 31 males and 61 females, and their age was (61.8±5.2) years. There were 43, 28 and 21 cases in monofocal group, bifocal group and depth of focus extension group, respectively. No statistically significant difference was found in clinical baseline data among the three groups. UCIVA, UCDVA, BCIVA and BCDVA in depth of focus extension group were 1.01±0.13, 0.92±0.18, 1.21±0.19 and 1.20±0.23, respectively, which were higher than those in monofocal group (0.62±0.12, 0.74±0.13, 1.02±0.17, 1.07±0.19, respectively) and bifocal group (0.67±0.15, 0.78±0.14, 1.01±0.16, 1.01±0.18, respectively), while absolute value of spherical equivalent [(-0.42±0.07) D] was lower than that in the other two groups [ (-0.49±0.05) D and (-0.45±0.08) D] (both P<0.05). UCNVA and BCNVA in bifocal group were 0.91±0.18 and 1.25±0.18, which were higher than those in depth of focus extension group (0.63±0.24 and 1.19±0.17) (both P<0.05). There were no significant differences in contrast sensitivity among the three groups under day vision or between monofocal group and bifocal group under night vision (all P>0.05), but the contrast sensitivity was higher in depth of focus extension group under night vision (3.0, 6.0, 12.0 c/d) than other two groups (all P<0.05). The score of ocular discomfort was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). The score of visual interference in bifocal group was lower than that in monofocal group and depth of focus extension group (both P<0.05). The scores of subjective feeling in bifocal group and depth of focus extension group were higher than that in monofocal group (both P<0.05). The reading score was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). There was no significant difference in total low-order aberration among the three groups (P=0.472). The total aberration and higher-order aberration [(0.74±0.35) µm and (0.41±0.12) µm] were the highest in monofocal group, followed by bifocal group [(0.61±0.21) µm and (0.22±0.09) µm] and depth of focus extension group [(0.46±0.13) µm and (0.06±0.09) µm] (all P<0.05). Conclusions: IOL implantation with depth of focus extension can enhance visual range, night vision and contrast sensitivity, and thus effectively improve postoperative visual quality and function in cataract patients. The bifocal IOL can better improve the patient's UCNVA and BCNVA, resulting in high satisfaction with visual quality.


Assuntos
Catarata , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Acuidade Visual , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidades de Contraste , Satisfação do Paciente , Inquéritos e Questionários
14.
Transl Vis Sci Technol ; 13(4): 11, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38578634

RESUMO

Background: The purpose of this study was to explore the protective effect of a shape memory polymeric shield on corneal endothelium during phacoemulsification in rabbits. Methods: Poly-(glycerol dodecanedioate) (PGD) with a transition temperature of 24.416°C was prepared to make a shape memory shield with a thickness of 100 µm, an arc length of 14 mm, and a radius of curvature of 8.8 mm. In the control group, a phaco-tip with bevel-down was used to simulate injury to the corneal endothelium by phacoemulsification in rabbits. In the experimental group, the pre-cooled and curled shape memory shield was injected into and removed from the anterior chamber before and after phaco-power release. Anterior segment optical coherence tomography (AS-OCT), confocal microscope, trypan blue/alizarin red staining, and scanning electron microscope were performed to measure endothelial damage after surgery. Results: One day postoperatively, the lost cell ratio of the control group and the experimental group were 28.08 ± 5.21% and 3.50 ± 1.43%, respectively (P < 0.0001), the damaged cell ratios were 11.83 ± 2.30% and 2.55 ± 0.52%, respectively (P < 0.0001), and the central corneal thicknesses (CCT) were 406.75 ± 16.74 µm and 340. 5 ±13.48 µm, respectively (P < 0.0001). Seven days postoperatively, the endothelial cell density (ECD) of the control group and the experimental group were 1674 ± 285/mm2 and 2561 ± 554/mm2, respectively (P < 0.05). The above differences were all statistically significant. Conclusions: This PGD based shape memory shield has a protective effect on corneal endothelium during phacoemulsification. It reduces postoperative corneal edema and ECD decrease in the short term after surgery. Translational Relevance: The shape memory PGD "shield" in this study may have a use in certain human patients with vulnerable corneas of low endothelial cell count or shallow anterior chambers.


Assuntos
Endotélio Corneano , Facoemulsificação , Animais , Humanos , Coelhos , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Córnea , Câmara Anterior
16.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658894

RESUMO

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Assuntos
Terapia a Laser , Lentes Intraoculares Multifocais , Facoemulsificação , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Terapia a Laser/métodos , Idoso , Refração Ocular/fisiologia , Implante de Lente Intraocular/métodos , Pseudofacia/fisiopatologia , Resultado do Tratamento , Desenho de Prótese , Extração de Catarata/métodos , Seguimentos
17.
BMC Ophthalmol ; 24(1): 198, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671381

RESUMO

BACKGROUND: Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). METHODS: This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. RESULTS: There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). CONCLUSIONS: Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. TRIAL REGISTRATION: This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).


Assuntos
Lentes Intraoculares , Acuidade Visual , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Facoemulsificação , Refração Ocular/fisiologia , Implante de Lente Intraocular , Desenho de Prótese , Período Pós-Operatório , Pseudofacia/fisiopatologia , Óptica e Fotônica