Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.964
Filtrar
1.
J Bodyw Mov Ther ; 39: 531-535, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876680

RESUMO

Body composition is a fundamental component of physical fitness related to the performance of Sitting volleyball (SV) players. Also, establishing the best method for evaluating the body composition of these para-athletes would be highly necessary for this field. The purpose of this study was (1) to describe the body composition of male and female highly trained SV players, (2) to compare the values obtained from this population by two different methods and (3) to establish validity on one of these methods. Thirteen Brazilian SV national team players (five males and eight females) participated in this study. The air-displacement plethysmography (ADP) method as the criterion assessment and the skinfolds (SF) method were conducted for each player. Results showed that there were no significant differences between the values of all players, which ADP and SF measured for body fat percentage (BF%) and body density (BD) (p > 0.05). We found significantly different values between male and female players for BF% by SF (p = 0.04) and BD by SF (p = 0.04). A high degree of reliability was found between ADP and SF measures for BF% and BD. There were statistically significant positive correlations between BF% and BD in all values for both methods (p < 0.01). This pilot study suggests that considering the magnitude of space, expense, and other limitations related to the ADP method against the SF method, we recommend using the SF method, which is a valid, viable and reliable method for measuring body composition in elite SV players.


Assuntos
Composição Corporal , Pletismografia , Dobras Cutâneas , Voleibol , Humanos , Masculino , Feminino , Voleibol/fisiologia , Projetos Piloto , Composição Corporal/fisiologia , Adulto Jovem , Pletismografia/métodos , Reprodutibilidade dos Testes , Adulto , Postura Sentada
2.
Res Vet Sci ; 175: 105320, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38838512

RESUMO

The aim of this prospective clinical study was to evaluate the efficacy of the Surgical Pleth Index (SPI), a validated nociception monitor in human anaesthesia, in dogs. The technology uses a plethysmographic signal from a specific pulse oximetry probe to analyse pulse wave amplitudes and heartbeat intervals. Twenty-six healthy dogs anaesthetised for castration were included. SPI, invasive mean arterial pressure (MAP) and heart rate (HR) were continuously monitored. The occurrence or resolution of a haemodynamic reaction (HDR), defined as a > 20% increase in HR and/or MAP, was assessed at predefined times: cutaneous incision, testicles' exteriorization, cutaneous suture, and fentanyl administration. Following nociceptive events, the dogs presenting a HDR showed a significant 8% and 10% increase in SPI at 3 and 5 min respectively, whereas after fentanyl administration, a 13% and 16% significant decrease in SPI were noted. Receiver operating characteristic curves analysis indicated a moderate performance for the dynamic variations of SPI over 1 min to predict a HDR (AUC: 0.68, threshold value: +15%) or its resolution after fentanyl administration (AUC of 0.72, threshold value: -15%) within 3 min. The SPI varied according to perioperative nociceptive events and analgesic treatment; however, its performance to anticipate a HDR was limited with high specificity but low sensivity. Refinement of the algorithm to specifically accommodate for the canine species may be warranted. Further studies are required to evaluate the influence of other factors on the performance of this index.


Assuntos
Nociceptividade , Orquiectomia , Animais , Cães , Masculino , Nociceptividade/efeitos dos fármacos , Estudos Prospectivos , Orquiectomia/veterinária , Fentanila/administração & dosagem , Fentanila/farmacologia , Pletismografia/veterinária , Frequência Cardíaca/efeitos dos fármacos , Oximetria/veterinária , Monitorização Fisiológica/veterinária , Monitorização Fisiológica/métodos
3.
Expert Rev Respir Med ; 18(3-4): 227-236, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38829281

RESUMO

BACKGROUND: Thoraco-abdominal asynchrony (TAA) is usually assessed by respiratory inductance plethysmography. The main parameter used for its assessment is the calculation of the phase angle based on Lissajous plots. However, there are some mathematical limitations to its use. RESEARCH DESIGN AND METHODS: Sequences of five breaths were selected from a) normal subjects, b) COPD patients, both at rest and during exercise, and c) patients with obstructive apnea syndrome. Automated analysis was performed calculating phase angle, loop rotation (clockwise or counterclockwise), global phase delay and loop area. TAA severity was estimated quantitatively and in subgroups. RESULTS: 2290 cycles were analyzed (55% clockwise rotation). Phase angle ranged from -86.90 to + 88.4 degrees, while global phase delay ranged from -179.75 to + 178.54. Despite a good correlation with global phase delay (p < 0.01, ANOVA test), phase angle and loop area were not able to correctly classify breaths with severe deviation and paradoxical movements (p=ns, Bonferroni post hoc test). CONCLUSIONS: Global phase delay covers the whole spectrum of TAA situations in a single value. It may be a relevant parameter for diagnosis and follow-up of clinical conditions leading to TAA. CLINICAL TRIAL REGISTRATION: The trial from which the traces were obtained was registered at ClinicalTrials.gov ;(identifier: NCT04597606).


Assuntos
Pletismografia , Doença Pulmonar Obstrutiva Crônica , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Abdome/fisiopatologia , Pletismografia/métodos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Respiração , Mecânica Respiratória/fisiologia
4.
Nutrients ; 16(12)2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38931164

RESUMO

The quality-initiative analysis of weekly duplicate PEAPOD® body composition measurements was conducted from clinical practice (January to September 2021) on preterm and term infants without respiratory support. Statistical analysis, including regression analysis, Bland-Altman plots and cv-root-mean-square tests, was performed. A total of 188 duplicate (376 individual) measurements were collected from 119 infants (88 preterm, 31 term). The median absolute difference between duplicates was 31.5 g for fat-free mass (FFM). Linear correlation analysis showed R2 = 0.97 for FFM. The absolute differences in FFM and fat mass did not significantly correlate with increasing age. The %FFM differed (p = 0.02) across body weight groups of 1 kg < BW ≤ 2 kg (1.8%; IQR: 0.8, 3.6) and BW > 3 kg (0.9%; IQR: 0.3, 2.1). The median absolute differences were 1 g (IQR: 0.4, 3.1) for body weight and 5.6 mL (IQR: 2.1, 11.8) for body volume. Body volume estimation is charged with a constant absolute error, which is the main factor for differences between repeated body composition assessments. This error becomes more prominent in infants with lower body weights. Nevertheless, reproducibility of weekly PEAPOD testing is sufficient to monitor body compartment changes, offering a foundation for nutritional decisions in both preterm and term infants.


Assuntos
Composição Corporal , Recém-Nascido Prematuro , Pletismografia , Humanos , Recém-Nascido , Reprodutibilidade dos Testes , Masculino , Feminino , Pletismografia/métodos , Lactente , Peso Corporal
5.
Physiol Meas ; 45(5)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38749433

RESUMO

Objective.Intra-esophageal pressure (Pes) measurement is the recommended gold standard to quantify respiratory effort during sleep, but used to limited extent in clinical practice due to multiple practical drawbacks. Respiratory inductance plethysmography belts (RIP) in conjunction with oronasal airflow are the accepted substitute in polysomnographic systems (PSG) thanks to a better usability, although they are partial views on tidal volume and flow rather than true respiratory effort and are often used without calibration. In their place, the pressure variations measured non-invasively at the suprasternal notch (SSP) may provide a better measure of effort. However, this type of sensor has been validated only for respiratory events in the context of obstructive sleep apnea syndrome (OSA). We aim to provide an extensive verification of the suprasternal pressure signal against RIP belts and Pes, covering both normal breathing and respiratory events.Approach.We simultaneously acquired suprasternal (207) and esophageal pressure (20) signals along with RIP belts during a clinical PSG of 207 participants. In each signal, we detected breaths with a custom algorithm, and evaluated the SSP in terms of detection quality, breathing rate estimation, and similarity of breathing patterns against RIP and Pes. Additionally, we examined how the SSP signal may diverge from RIP and Pes in presence of respiratory events scored by a sleep technician.Main results.The SSP signal proved to be a reliable substitute for both esophageal pressure (Pes) and respiratory inductance plethysmography (RIP) in terms of breath detection, with sensitivity and positive predictive value exceeding 75%, and low error in breathing rate estimation. The SSP was also consistent with Pes (correlation of 0.72, similarity 80.8%) in patterns of increasing pressure amplitude that are common in OSA.Significance.This work provides a quantitative analysis of suprasternal pressure sensors for respiratory effort measurements.


Assuntos
Pressão , Sono , Humanos , Masculino , Sono/fisiologia , Feminino , Adulto , Pletismografia , Processamento de Sinais Assistido por Computador , Respiração , Esterno/fisiologia , Pessoa de Meia-Idade , Polissonografia , Adulto Jovem
6.
Turk J Med Sci ; 54(1): 115-120, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38812625

RESUMO

Background/aim: We aimed to search the relationship between the preoperative PVI (pleth variability index) and intraoperative respiratory parameters to reveal whether PVI can be used as a prediction tool in bariatric surgery. Materials and methods: Forty patients undergoing bariatric surgery were included. Noninvasive pleth variability index measured via finger probe before induction of general anesthesia. Following intubation each patient was ventilated in controlled mode. Intraoperative blood pressure, peak airway pressure, end-tidal CO2, SpO2, PEEP, and FiO2 were recorded every 5 min for the first 10 min and then every 10 min until extubation. Steroid and bronchodilator requirements were recorded. Results: The systolic pressure-PVI, oxygen saturation-PVI relationship was statistically significant (p = 0.03, p = 0.013). A relationship was found between pleth variability index and peak airway pressure (p = 0.002). No correlation was detected between end-tidal CO2 and pleth variability index. The relationship between steroid, bronchodilator use, and PVI was significant (p = 0.05, p = 0.01). A positive correlation between PEEP and PVI was detected at varying time points. A positive correlation was found between FiO2-PVI. Conclusion: A relationship was found between PVI and intraoperative peak airway pressures, oxygen saturation, PEEP, bronchodilatator, and steroid usage. This result may be inspiring to conduct larger studies addressing the issue of predicting intraoperative respiratory problems in bariatric surgeries.


Assuntos
Cirurgia Bariátrica , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Complicações Intraoperatórias/diagnóstico , Pletismografia/métodos
7.
Respir Physiol Neurobiol ; 326: 104278, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38735425

RESUMO

OBJECTIVES: We investigated the effect of inspiratory muscle training (IMT) on inspiratory muscle strength, functional capacity and respiratory muscle kinematics during exercise in healthy older adults. METHODS: 24 adults were randomised into an IMT or SHAM-IMT group. Both groups performed 30 breaths, twice daily, for 8 weeks, at intensities of ∼50 % maximal inspiratory pressure (PImax; IMT) or <15 % PImax (SHAM-IMT). Measurements of PImax, breathing discomfort during a bout of IMT, six-minute walk distance, physical activity levels, and balance were assessed pre- and post-intervention. Respiratory muscle kinematics were assessed via optoelectronic plethysmography (OEP) during constant work rate cycling. RESULTS: PImax was significantly improved (by 20.0±11.9 cmH2O; p=0.001) in the IMT group only. Breathing discomfort ratings during IMT significantly decreased (from 3.5±0.9-1.7±0.8). Daily sedentary time was decreased (by 28.0±39.8 min; p=0.042), and reactive balance significantly improved (by 1.2±0.8; p<0.001) in the IMT group only. OEP measures showed a significantly greater contribution of the pulmonary and abdominal rib cage compartments to total tidal volume expansion post-IMT. CONCLUSIONS: IMT significantly improves inspiratory muscle strength and breathing discomfort in this population. IMT induces greater rib cage expansion and diaphragm descent during exercise, thereby suggesting a less restrictive effect on thoracic expansion and increased diaphragmatic power generation.


Assuntos
Exercícios Respiratórios , Músculos Respiratórios , Humanos , Masculino , Feminino , Idoso , Exercícios Respiratórios/métodos , Músculos Respiratórios/fisiologia , Pessoa de Meia-Idade , Força Muscular/fisiologia , Exercício Físico/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Inalação/fisiologia , Fenômenos Biomecânicos/fisiologia , Pletismografia
8.
Sensors (Basel) ; 24(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38733031

RESUMO

This study aimed to propose a portable and intelligent rehabilitation evaluation system for digital stroke-patient rehabilitation assessment. Specifically, the study designed and developed a fusion device capable of emitting red, green, and infrared lights simultaneously for photoplethysmography (PPG) acquisition. Leveraging the different penetration depths and tissue reflection characteristics of these light wavelengths, the device can provide richer and more comprehensive physiological information. Furthermore, a Multi-Channel Convolutional Neural Network-Long Short-Term Memory-Attention (MCNN-LSTM-Attention) evaluation model was developed. This model, constructed based on multiple convolutional channels, facilitates the feature extraction and fusion of collected multi-modality data. Additionally, it incorporated an attention mechanism module capable of dynamically adjusting the importance weights of input information, thereby enhancing the accuracy of rehabilitation assessment. To validate the effectiveness of the proposed system, sixteen volunteers were recruited for clinical data collection and validation, comprising eight stroke patients and eight healthy subjects. Experimental results demonstrated the system's promising performance metrics (accuracy: 0.9125, precision: 0.8980, recall: 0.8970, F1 score: 0.8949, and loss function: 0.1261). This rehabilitation evaluation system holds the potential for stroke diagnosis and identification, laying a solid foundation for wearable-based stroke risk assessment and stroke rehabilitation assistance.


Assuntos
Redes Neurais de Computação , Fotopletismografia , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Reabilitação do Acidente Vascular Cerebral/instrumentação , Reabilitação do Acidente Vascular Cerebral/métodos , Fotopletismografia/métodos , Fotopletismografia/instrumentação , Acidente Vascular Cerebral/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Pletismografia/métodos , Pletismografia/instrumentação , Desenho de Equipamento , Dispositivos Eletrônicos Vestíveis , Algoritmos
9.
Mayo Clin Proc ; 99(6): 902-912, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38661596

RESUMO

OBJECTIVE: To evaluate mortality outcomes by varying degrees of reduced calf muscle pump (CMP) ejection fraction (EF). PATIENTS AND METHODS: Consecutive adult patients who underwent venous air plethysmography testing at the Mayo Clinic Gonda Vascular Laboratory (January 1, 2012, through December 31, 2022) were divided into groups based on CMP EF for the assessment of all-cause mortality. Other venous physiology included measures of valvular incompetence and clinical venous disease (CEAP [clinical presentation, etiology, anatomy, and pathophysiology] score). Mortality rates were calculated using the Kaplan-Meier method. RESULTS: During the study, 5913 patients met the inclusion criteria. During 2.84-year median follow-up, there were 431 deaths. Mortality rates increased with decreasing CMP EF. Compared with EF of 50% or higher, the hazard ratios (95% CIs) for mortality were as follows: EF of 40% to 49%, 1.4 (1.0 to 2.0); EF of 30% to 39%, 1.6 (1.2 to 2.4); EF of 20% to 29%, 1.7 (1.2 to 2.4); EF of 10% to 19%, 2.4 (1.7 to 3.3) (log-rank P≤.001). Although measures of venous valvular incompetence did not independently predict outcomes, venous disease severity assessed by CEAP score was predictive. After adjusting for several clinical covariates, both CMP EF and clinical venous disease severity assessed by CEAP score remained independent predictors of mortality. CONCLUSION: Mortality rates are higher in patients with reduced CMP EF and seem to increase with each 10% decrement in CMP EF. The mortality mechanism does not seem to be impacted by venous valvular incompetence and may represent variables intrinsic to muscular physiology.


Assuntos
Perna (Membro) , Músculo Esquelético , Volume Sistólico , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Músculo Esquelético/fisiopatologia , Perna (Membro)/irrigação sanguínea , Idoso , Adulto , Pletismografia , Insuficiência Venosa/fisiopatologia , Insuficiência Venosa/mortalidade , Estudos Retrospectivos , Causas de Morte
10.
J Vasc Surg Venous Lymphat Disord ; 12(4): 101861, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38428501

RESUMO

BACKGROUND: Column interruption duration (CID) is a noninvasive surrogate for venous refill time (VFT), a parameter used in ambulatory venous pressure measurement. CID is more accurate than invasive VFT measurement because it avoids errors involved with indirect access of the deep system through the dorsal foot vein. The aim of this retrospective single center study is to analyze the clinical usefulness of CID in assessment of chronic venous disease (CVD). METHODS: A total of 1551 limbs (777 patients) were referred with CVD symptoms over a 5-year period (2018-2023); CID, air plethysmography, and duplex reflux data were analyzed. Of these limbs, 679 had supine venous pressure data as well. The pathology was categorized as obstruction if supine peripheral venous pressure was >11 mm Hg and as reflux if duplex reflux time in superficial or deep veins was >1 second. CID was measured via Doppler monitoring of flow in the great saphenous vein (GSV) and one of the paired posterior tibial (PT) veins near the ankle in the erect posture. The calf is emptied by rapid inflation cuff. CID is the time interval in seconds when cephalad venous flow in great saphenous vein and posterior tibial veins reappear after calf ejection. A CID <20 seconds in either vein is abnormal similar to the threshold used in VFT measurement. RESULTS: Thirty-two percent of the limbs had obstruction, 17% had reflux, and 37% had a combination; 14% had neither. Higher clinical-etiology-anatomy-pathophysiology (CEAP) clinical classes (C4-6) were prevalent in 44% of pure reflux, significantly less (P < .0001) than in pure obstruction (73%) or obstruction plus reflux subsets (72%), partly reflecting distribution of pathology. There is a progressive increase in supine venous pressure and abnormal CID (P < .0001 and P < .0001, respectively) in successive CEAP clinical class. No such correlation between CEAP and any of the reflux severity grading methods (reflux segment score, Venous Filling Index, and Kistner axial grading) was observed. Abnormal CID (55%) was more prevalent in higher CEAP classes (>4) (P < .0001) than in lesser clinical classes (0-2) or limbs with neither obstruction nor reflux (P < .01). CONCLUSIONS: Obstruction seems to be a more dominant pathology in clinical progression among CEAP clinical classes than reflux. CID is abnormal in both obstructive and refluxive pathologies and may represent a common end pathway for similar clinical manifestations (eg, ulcer). These data suggest a useful role for CID measurement in clinical assessment of limbs with CVD.


Assuntos
Pletismografia , Insuficiência Venosa , Humanos , Estudos Retrospectivos , Doença Crônica , Feminino , Masculino , Pessoa de Meia-Idade , Pressão Venosa , Insuficiência Venosa/fisiopatologia , Insuficiência Venosa/diagnóstico por imagem , Fatores de Tempo , Adulto , Idoso , Ultrassonografia Doppler Dupla , Valor Preditivo dos Testes , Veia Safena/fisiopatologia , Veia Safena/diagnóstico por imagem , Monitorização Ambulatorial da Pressão Arterial , Reprodutibilidade dos Testes
11.
J Vasc Surg Venous Lymphat Disord ; 12(4): 101869, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38460817

RESUMO

OBJECTIVE: Reduced calf muscle pump function (CPF) is an independent risk factor for venous thromboembolism and mortality. We aimed to evaluate the relationship between handgrip strength (HGS) and CPF. METHODS: Patients referred to the Gonda Vascular Laboratory for noninvasive venous studies were identified and consented. Patients underwent standard venous air plethysmography protocol. CPF (ejection fraction) was measured in each lower extremity of ambulatory patients by comparing refill volume after ankle flexes and passive refill volumes. The cutoff for reduced CPF (rCPF) was defined as an ejection fraction of <45%. Maximum HGS bilaterally was obtained (three trials per hand) using a dynamometer. HGS and CPF were compared (right hand to calf, left hand to calf) and the correlation between the measures was evaluated. RESULTS: 115 patients (mean age, 59.2 ± 17.4 years; 67 females, mean body mass index, 30.83 ± 6.46) were consented and assessed for HGS and CPF. rCPF was observed in 53 right legs (46%) and 67 left legs (58%). CPF was reduced bilaterally in 45 (39%) and unilaterally in 30 (26%) patients. HGS was reduced bilaterally in 74 (64.3%), unilaterally in 23 (20%), and normal in 18 (15.7%) patients. Comparing each hand/calf pair, no significant correlations were seen between HGS and CPF. The Spearman's rank correlation coefficients test yielded values of 0.16 for the right side and 0.10 for the left side. CONCLUSIONS: There is no significant correlation between HGS and CPF, demonstrating that HGS measurements are not an acceptable surrogate for rCPF, indicating different pathophysiological mechanisms for each process.


Assuntos
Força da Mão , Perna (Membro) , Músculo Esquelético , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Perna (Membro)/irrigação sanguínea , Pletismografia , Volume Sistólico , Valor Preditivo dos Testes , Fatores de Risco
12.
Am J Vet Res ; 85(6)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38503051

RESUMO

OBJECTIVE: To compare the accuracy of doppler ultrasound (DOP) and pulse oximeter plethysmography (POP) in the measurement of systolic arterial pressure (SAP) to invasive blood pressure (IBP) in anesthetized dogs. ANIMALS: 40 client-owned healthy dogs > 10 kg. METHODS: Dogs were anesthetized for surgical procedures in dorsal recumbency. Invasive blood pressure was measured from a dorsal pedal artery. DOP and POP device probes were placed over the median caudal artery with a flow-occluding cuff for noninvasive blood pressure measurement. Systolic arterial pressure measured by DOP, loss of pulse oximeter plethysmograph (POPL), and return of pulse oximeter plethysmograph (POPR) were compared to SAP measured by IBP. A linear mixed model was used to determine correlation. Bland-Altman analyses were performed to determine bias, SD, and limits of agreement. The accuracy of DOP and POP was compared to IBP across different tensive states. RESULTS: Conditional R2 values for DOP, POPL, and POPR versus IBP were 0.92, 0.85, and 0.87, respectively (all P < .001). The biases for DOP, POPL, and POPR compared to IBP were +7.6 ± 13.1, +3.9 ± 14.4, and +8.6 ± 15.2 mm Hg (bias ± SD), respectively. Limits of agreement (lower, upper) were (-18.1, +33.3), (-24.3, +32.1), and (-21.2, +38.4) mm Hg for DOP, POPL, and POPR, respectively. DOP and POP overestimated SAP during hypotension (SAP < 90 mm Hg), DOP to a lesser magnitude. CLINICAL RELEVANCE: DOP measured from the median caudal artery may be acceptable for SAP measurement in dorsally recumbent, healthy anesthetized dogs > 10 kg. POP was determined an unacceptable method.


Assuntos
Anestesia , Determinação da Pressão Arterial , Oximetria , Pletismografia , Ultrassonografia Doppler , Animais , Cães , Oximetria/veterinária , Ultrassonografia Doppler/veterinária , Pletismografia/veterinária , Pletismografia/métodos , Masculino , Determinação da Pressão Arterial/veterinária , Determinação da Pressão Arterial/métodos , Anestesia/veterinária , Feminino , Pressão Arterial , Artérias
13.
Comp Med ; 74(2): 81-91, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514175

RESUMO

Plethysmography is employed in nonhuman primates (NHPs) to calculate respiratory minute volume and determine the exposure time required to deliver an aerosol at the target dose. Anesthetic drugs can impact breathing parameters like steady-state minute volume (SSMV) central to aerosol dosing. Alfaxalone-midazolam mixtures (AM) provide superior parameters for plethysmography in cynomolgus macaques. An obstacle to the use of AM is the volume required to anesthetize via intramuscular injection. A more concentrated formulation of alfaxalone will reduce injection volumes and refine AM protocols. The purpose of this study was to compare AM using the Indexed 10-mg/mL (AM10) formulation compared with an investigational 40-mg/mL (AM40) formulation for IM administration in cynomolgus macaques undergoing plethysmography. We hypothesized that AM10 and AM40 would show no difference in quality of anesthesia (QA), duration of anesthesia, SSMV, accumulated minute volume (AMV), and side effects. We also hypothesized that female macaques would have a longer duration of anesthesia compared with males using both formulations. The study used 15 cynomolgus macaques comprised of 8 females and 7 males. NHPs were compared between 2 separate and randomized anesthetic events no less than one week apart. Each animal served as its own control and animals were randomized by random number generation. Anesthetized NHPs were placed in a sealed plethysmography chamber, and minute volume measurements were calculated every 10 s to determine SSMV. Once SSMV was achieved for 20 min, the trial ended. There were no statistically significant differences between AM10 and AM40 for duration of anesthesia, SSMV, AMV, side effects, or QA. AM40 had a significantly smaller injection volume. Females did not show a significantly longer median duration of anesthesia using either of the alfaxalone formulations. Overall, AM40 offers a more humane anesthetic than AM10 for plethysmography in cynomolgus macaques.


Assuntos
Macaca fascicularis , Midazolam , Pletismografia , Pregnanodionas , Animais , Pregnanodionas/administração & dosagem , Pregnanodionas/farmacologia , Midazolam/administração & dosagem , Midazolam/farmacologia , Feminino , Masculino , Injeções Intramusculares , Anestésicos/administração & dosagem , Anestésicos/farmacologia , Anestesia/veterinária , Anestésicos Combinados/administração & dosagem , Anestésicos Combinados/farmacologia
14.
IEEE J Biomed Health Inform ; 28(5): 2699-2712, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38442050

RESUMO

OBJECTIVE: To develop a cuffless method for estimating blood pressure (BP) from fingertip strain plethysmography (SPG) recordings. METHODS: A custom-built micro-electromechanical systems (MEMS) strain sensor is employed to record heartbeat-induced vibrations at the fingertip. An XGboost regressor is then trained to relate SPG recordings to beat-to-beat systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP) values. For this purpose, each SPG segment in this setup is represented by a feature vector consisting of cardiac time interval, amplitude features, statistical properties, and demographic information of the subjects. In addition, a novel concept, coined geometric features, are introduced and incorporated into the feature space to further encode the dynamics in SPG recordings. The performance of the regressor is assessed on 32 healthy subjects through 5-fold cross-validation (5-CV) and leave-subject-out cross validation (LSOCV). RESULTS: Mean absolute errors (MAEs) of 3.88 mmHg and 5.45 mmHg were achieved for DBP and SBP estimations, respectively, in the 5-CV setting. LSOCV yielded MAEs of 8.16 mmHg for DBP and 16.81 mmHg for SBP. Through feature importance analysis, 3 geometric and 26 integral-related features introduced in this work were identified as primary contributors to BP estimation. The method exhibited robustness against variations in blood pressure level (normal to critical) and body mass index (underweight to obese), with MAE ranges of [1.28, 4.28] mmHg and [2.64, 7.52] mmHg, respectively. CONCLUSION: The findings suggest high potential for SPG-based BP estimation at the fingertip. SIGNIFICANCE: This study presents a fundamental step towards the augmentation of optical sensors that are susceptible to dark skin tones.


Assuntos
Determinação da Pressão Arterial , Pressão Sanguínea , Dedos , Pletismografia , Processamento de Sinais Assistido por Computador , Humanos , Determinação da Pressão Arterial/métodos , Dedos/fisiologia , Dedos/irrigação sanguínea , Adulto , Pletismografia/métodos , Masculino , Pressão Sanguínea/fisiologia , Feminino , Sistemas Microeletromecânicos , Adulto Jovem
15.
Int. j. clin. health psychol. (Internet) ; 24(1): [100442], Ene-Mar, 2024. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-230383

RESUMO

Background/Objective: Men do not use external condoms for several reasons, which can result in public health problems. One of these is related to Condom-Associated Erectile Problems. This study aimed to examine the sexual arousal response of heterosexual men when using an external condom made of synthetic resin type AT-10. Method: A total of 82 Colombian young men (Mage = 23.17 years, SD = 3.04, age range = 18–30) participated in this experimental study. Two random groups (experimental and control; n = 41 each) were compared. The experimental group used condoms, whereas the control group did not. Fit and feel condom perceptions, initial erectile scores, age, and substance use were controlled for. Erection was measured while viewing a sexual video by using penile plethysmography and subjective arousal. Results: The results, obtained from comparing the experimental group (using pre-erection condoms) with the control group (not using condoms), revealed no significant difference in both subjective and physiological sexual arousal. This suggests that pre-erection condoms do not have an effect on the erectile response. Discussion: More research is needed in this area to provide treatment and clinical interventions or sexual and reproductive education to mitigate the occurrence of sexual dysfunction, unplanned pregnancies, or sexually transmitted infections. Also, research addresses public health issues related to the prevention and/or intervention of sexual risk behaviors and sexual dysfunctions, highlighting their significance in sexual education and clinical practice.(AU)


Assuntos
Humanos , Masculino , Preservativos , Pletismografia , Ereção Peniana , Disfunção Erétil , Colômbia , Psicologia Clínica , Psicologia
16.
PLoS One ; 19(3): e0299252, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38470892

RESUMO

BACKGROUND: Pulmonary function testing by barometric whole-body plethysmography (BWBP) is a long-established and well-accepted, non-invasive investigative procedure in cats. HYPOTHESIS/OBJECTIVES: To evaluate, if different acclimatization times influence the measurement parameters of BWBP in healthy adult cats. ANIMALS: 48 healthy adult cats. METHODS: In the prospective observational study, healthy cats were placed in a measuring chamber and BWBP was performed over 30 minutes. Parameters obtained during the three measurement units of 10 minutes each (T1, T2 and T3) were compared. RESULTS: All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) over the three time periods. From T1-T2, the parameters minute volume per body weight (p<0.001), peak inspiratory flow per body weight (p<0.001), peak expiratory flow per body weight (p = 0.002), pause (p = 0.03), enhanced pause (p = 0.03) and quotient of peak expiratory flow divided by expiratory flow at end expiratory volume plus 50% tidal volume (p = 0.03) changed significantly. From the time interval T2-T3, only respiratory rate (p = 0.02), inspiratory time (p = 0.02), expiratory time (p = 0.04), and relaxation time (p = 0.01) changed significantly. All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) between T1 and T3. Age had a significant influence on all parameters except for peak expiratory flow per body weight and peak inspiratory flow per body weight. The parameters were not influenced by sex. CONCLUSION AND CLINICAL IMPORTANCE: All measurement parameters except tidal volume per body weight were significantly affected by acclimatization time. Controlling for age and sex, there was still a significant influence of acclimatization time on all parameters except for tidal volume per body weight. Standardization of the acclimatization time for future studies would be appropriate in order to maintain comparability.


Assuntos
Pletismografia , Gatos , Animais , Pletismografia Total/métodos , Pletismografia Total/veterinária , Testes de Função Respiratória/métodos , Volume de Ventilação Pulmonar , Peso Corporal
17.
Pediatr Allergy Immunol Pulmonol ; 37(1): 7-12, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484265

RESUMO

Background: Structured light plethysmography (SLP) is a novel light-based method that captures chest wall movements to evaluate tidal breathing. Methods: Thirty-two children who underwent lung surgery were enrolled. Their clinical history was collected along with spirometry and SLP. Results: Median age of surgery was 9 months (interquartile range 4-30). Most frequent diagnosis was congenital pulmonary airway malformation (14/32), then pulmonary sequestration (9/32), tumor (5/32), and bronchogenic cyst (4/32). The most frequent surgical approach was lobectomy (59%), segmentectomy (38%), and complete resection (3%). More than 80% had surgery when younger than 3 years of age. Eight patients had short-term complications (pleural effusion was the most frequent), while long-term effects were reported in 15 patients (19% recurrent cough, 13% thoracic deformities, 13% airway infections, 9% wheezing, 6% reduced exercise tolerance, and 3% columnar deformities). Spirometry was normal in 9/22 patients. Nine patients had a restrictive pattern, while 4 showed a mild bronco-reactivity. Ten patients did not perform spirometry because of young age. SLP revealed the presence of obstructive pattern in 10% of patients (IE50 > 1.88) and showed a significant difference between the two hemithorax in 29% of patients. Discussion: SLP may be a new method to evaluate lung function, without collaboration and radiation exposure, in children who underwent lung resection, also in preschool age.


Assuntos
Pletismografia , Procedimentos Cirúrgicos Pulmonares , Criança , Pré-Escolar , Humanos , Lactente , Pletismografia/métodos , Respiração , Espirometria/métodos , Pulmão/cirurgia
18.
J Neurodev Disord ; 16(1): 6, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429713

RESUMO

BACKGROUND: Angelman syndrome (AS) is a rare neurodevelopmental disorder characterized by severe intellectual disability, little to no expressive speech, visual and motor problems, emotional/behavioral challenges, and a tendency towards hyperphagia and weight gain. The characteristics of AS make it difficult to measure these children's functioning with standard clinical tests. Feasible outcome measures are needed to measure current functioning and change over time, in clinical practice and clinical trials. AIM: Our first aim is to assess the feasibility of several functional tests. We target domains of neurocognitive functioning and physical growth using the following measurement methods: eye-tracking, functional Near-Infrared Spectroscopy (fNIRS), indirect calorimetry, bio-impedance analysis (BIA), and BOD POD (air-displacement plethysmography). Our second aim is to explore the results of the above measures, in order to better understand the AS phenotype. METHODS: The study sample consisted of 28 children with AS aged 2-18 years. We defined an outcome measure as feasible when (1) at least 70% of participants successfully finished the measurement and (2) at least 60% of those participants had acceptable data quality. Adaptations to the test procedure and reasons for early termination were noted. Parents rated acceptability and importance and were invited to make recommendations to increase feasibility. The results of the measures were explored. RESULTS: Outcome measures obtained with eye-tracking and BOD POD met the definition of feasibility, while fNIRS, indirect calorimetry, and BIA did not. The most important reasons for early termination of measurements were showing signs of protest, inability to sit still and poor/no calibration (eye-tracking specific). Post-calibration was often applied to obtain valid eye-tracking results. Parents rated the BOD POD als most acceptable and fNIRS as least acceptable for their child. All outcome measures were rated to be important. Exploratory results indicated longer reaction times to high salient visual stimuli (eye-tracking) as well as high body fat percentage (BOD POD). CONCLUSIONS: Eye-tracking and BOD POD are feasible measurement methods for children with AS. Eye-tracking was successfully used to assess visual orienting functions in the current study and (with some practical adaptations) can potentially be used to assess other outcomes as well. BOD POD was successfully used to examine body composition. TRIAL REGISTRATION: Registered d.d. 23-04-2020 under number 'NL8550' in the Dutch Trial Register: https://onderzoekmetmensen.nl/en/trial/23075.


Assuntos
Síndrome de Angelman , Criança , Humanos , Síndrome de Angelman/complicações , Síndrome de Angelman/diagnóstico , Reprodutibilidade dos Testes , Composição Corporal , Pletismografia/métodos , Impedância Elétrica
19.
Paediatr Anaesth ; 34(6): 559-567, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38348932

RESUMO

BACKGROUND: Intraoperative fluid therapy maintains normovolemia, normal tissue perfusion, normal metabolic function, normal electrolytes, and acid-base status. Plethysmographic variability index has been shown to predict fluid responsiveness but its role in guiding intraoperative fluid therapy is still elusive. AIMS: The aim of the present study was to compare intraoperative goal-directed fluid therapy based on plethysmographic variability index with liberal fluid therapy in term neonates undergoing abdominal surgeries. METHODS: A prospective randomized controlled study was conducted in a tertiary care centre, over a period of 18 months. A total of 30 neonates completed the study out of 132 neonates screened. Neonates with tracheoesophageal fistula, congenital diaphragmatic hernia, congenital heart disease, respiratory disorders, creatinine clearance <90 mL/min and who were hemodynamically unstable were excluded. Neonates were randomized to goal-directed fluid therapy group where the plethysmographic variability index was targeted at <18 or liberal fluid therapy group. Primary outcome was comparison of total amount of fluid infused intraoperatively in both the groups. Secondary outcomes included intraoperative and postoperative arterial blood gas parameters, biochemical parameters, use of vasopressors, number of fluid boluses, complications and duration of hospital stay. RESULTS: There was no significant difference in total intraoperative fluid infused [90 (84-117.5 mL) in goal-directed fluid therapy and 105 (85.5-144.5 mL) in liberal fluid therapy group (p = .406)], median difference (95% CI) -15 (-49.1 to 19.1). There was a decrease in serum lactate levels in both groups from preoperative to postoperative 24 h. The amount of fluid infused before dopamine administration was significantly higher in liberal fluid therapy group (58 [50.25-65 mL]) compared to goal-directed fluid therapy group (36 [22-44 mL], p = .008), median difference (95% CI) -22 (-46 to 2). In postoperative period, the total amount of fluid intake over 24 h was comparable in two groups (222 [204-253 mL] in goal-directed fluid therapy group and 224 [179.5-289.5 mL] in liberal fluid therapy group, p = .917) median difference (95% CI) cutoff -2 (-65.3 to 61.2). CONCLUSION: Intraoperative plethysmographic variability index-guided goal-directed fluid therapy was comparable to liberal fluid therapy in terms of total volume of fluid infused in neonates during perioperative period. More randomized controlled trials with higher sample size are required. TRIAL REGISTRATION: Central Trial Registry of India (CTRI/2020/02/023561).


Assuntos
Abdome , Hidratação , Pletismografia , Humanos , Hidratação/métodos , Recém-Nascido , Estudos Prospectivos , Masculino , Feminino , Pletismografia/métodos , Abdome/cirurgia , Gasometria/métodos , Cuidados Intraoperatórios/métodos , Resultado do Tratamento
20.
Clin Transl Sci ; 17(2): e13735, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38344891

RESUMO

Buloxibutid (also known as C21) is a potent and selective angiotensin II type 2 receptor (AT2R) agonist, in development for oral treatment of fibrotic lung disease. This phase I, open-label, pharmacodynamic study investigated vascular effects of buloxibutid in five healthy male volunteers. Subjects were administered intra-arterial infusions of buloxibutid for 5 min in ascending doses of 3, 10, 30, 100, and 200 µg/min, infused sequentially in the forearm. Infusions of sodium nitroprusside (SNP) solution in doses of 0.8-3.2 µg/min were administered as a positive control. Forearm blood flow (FBF) was measured by venous occlusion plethysmography. Safety and tolerability of intra-arterial administrations of buloxibutid were evaluated. Following infusion of buloxibutid in doses of 3-200 µg/min, the range of increase in FBF was 27.8%, 17.2%, 37.0%, 28.5%, and 60.5%, compared to the respective baseline. The largest increase was observed in the highest dose group. Infusions of SNP as a positive control, increased FBF 230-320% compared to baseline. Three adverse events (AEs) of mild intensity, not related to buloxibutid or SNP, were reported for two subjects. Two of these AEs were related to study procedures. There were no clinically relevant changes in arterial blood pressure during the study period. Intra-arterial infusion of buloxibutid in low, ascending doses increased FBF, indicating that buloxibutid may be effective in conditions associated with endothelial dysfunction. Venous occlusion plethysmography was found to be a useful method to explore pharmacodynamic vascular effects of novel AT2R agonists, while avoiding systemic adverse effects.


Assuntos
Pletismografia , Receptor Tipo 2 de Angiotensina , Humanos , Masculino , Nitroprussiato/efeitos adversos , Pletismografia/métodos , Antebraço/irrigação sanguínea , Fluxo Sanguíneo Regional , Vasodilatação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...