Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 909
Filtrar
1.
World J Surg ; 48(7): 1674-1680, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38877993

RESUMO

BACKGROUND: For abdominal fascial closure, the choice of optimal suture material and appropriate suture technique are of paramount importance to prevent the incidence of incisional hernia. Although barbed sutures are widely used in various surgical fields, their safety and feasibility on abdominal fascial closure which requires the most tensile strength for security have not been established yet. METHODS: We conducted a prospective, single-arm, interventional clinical trial to present the postoperative outcomes of using barbed sutures in abdominal fascial closure between April 2021 and August 2021. Patients with colorectal cancer who underwent minimally invasive surgery in elective setting were included. For all participants, monofilament polydioxanone barbed suture, MONOFIX®, was used to secure the abdominal fasica. The primary outcome was the 1-year incidence of incisional hernia assessed by computed tomography. RESULTS: A total of 30 patients were included. The median fascial incision length and suture length were 6.5 cm (range, 6-7.5 cm) and 31 cm (range, 27.5-39.0 cm), respectively. The median procedure time of abdominal fascial closure was 4 min (range, 3-9 min). There was no incidence of unexpected event related to suturing including suture cutting, stopper separation from threads, and suture loosening. One case of superficial surgical site infection occurred during postoperative hospital stays. There was no fascial dehiscence, incisional hernia, and adhesive ileus during a median follow-up period of 17.5 months. CONCLUSION: Monofilament polydioxanone barbed suture, MONOFIX®, may be used safely and effectively on abdominal fascial closure. GOV NUMBER: NCT05872334.


Assuntos
Hérnia Incisional , Polidioxanona , Suturas , Humanos , Masculino , Estudos Prospectivos , Feminino , Pessoa de Meia-Idade , Idoso , Hérnia Incisional/prevenção & controle , Técnicas de Sutura , Técnicas de Fechamento de Ferimentos Abdominais/instrumentação , Resultado do Tratamento , Neoplasias Colorretais/cirurgia , Adulto , Idoso de 80 Anos ou mais , Resistência à Tração
2.
BMC Pulm Med ; 24(1): 238, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750487

RESUMO

BACKGROUND: Biodegradable (BD) stents made from polydioxanone have been used only in human airways. These stents combine the advantages of classical tracheal stents, and fewer side effects are expected due to their biocompatibility and their time-limited presence in airways. However, new clinical consequences have arisen. Here, the authors share their experiences with BD stents for tracheal indications, focusing on their safety and efficacy. METHODS: This was a retrospective review of a collected database of adult patients who underwent implantation of biodegradable tracheal stents between September 2013 and December 2022 at the Department of Respiratory Medicine of the 1st Faculty of Medicine in Prague and Thomayer University Hospital. The indications included functionally significant nonmalignant tracheal stenosis and tracheomalacia. Self-expandable, biodegradable, polydioxanone tracheal stents manufactured by ELLA-CS Ltd. (Hradec Kralove, Czech Republic) were implanted during rigid bronchoscopy under general anaesthesia. All patients were followed up in the department and were provided with the necessary care. The main efficacy and safety parameters and relationships were analysed using descriptive statistics and Fisher´s exact, Wilcoxon and Kruskal‒Wallis tests. RESULTS: A total of 65 stents were implanted in 47 adult patients. During the first two months after implantation, when adequate function was expected, the stent was found to be effective in 26 out of 39 patients who completed this period (66.7%). The clinical effectiveness reached 89.7%, as early restenoses were mostly mild and necessitated treatment in only 4 patients. The frequencies of significant mucostasis, migration and granulation tissue growth were 2.6%, 7.5% and 23.1%, respectively, during this period. Thirty-four participants completed the half-year follow-up period after the first or second stent insertion, and some were followed up beyond this period. Poor control of symptoms, the development of restenosis and the need for interventions were characteristic of this period as the stents degraded. Twenty-two patients who experienced remodelling or stabilization of the tracheal lumen achieved a stent-free state. Seven patients underwent subsequent surgical treatment. CONCLUSIONS: BD stents are safe and provide adequate tracheal support until they begin to degrade. The use of BD stents necessitates close monitoring of patients and accurate treatment of possible restenosis. TRIAL REGISTRATION: Based on project NT14146 - Biodegradable stents in the management of the large airways (2013-2015, MZ0/NT), registered on May 1, 2013, in the Research and Development and Innovation Information System of the Czech Republic and at ClinicalTrials.gov (reg. no. NCT02620319, December 2, 2015).


Assuntos
Implantes Absorvíveis , Broncoscopia , Stents , Estenose Traqueal , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Estudos Retrospectivos , Adulto , Estenose Traqueal/cirurgia , Idoso , Polidioxanona , Traqueomalácia/cirurgia , República Tcheca , Resultado do Tratamento , Traqueia/cirurgia , Desenho de Prótese , Adulto Jovem
3.
Biomater Adv ; 161: 213870, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38701686

RESUMO

Wound healing following skin tumour surgery still remains a major challenge. To address this issue, polysaccharide-loaded nanofibrous mats have been engineered as skin patches on the wound site to improve wound healing while simultaneously eliminating residual cancer cells which may cause cancer relapse. The marine derived polysaccharides kappa-carrageenan (KCG) and fucoidan (FUC) were blended with polydioxanone (PDX) nanofibers due to their inherent anti-cancer activity conferred by the sulphate groups as well as their immunomodulatory properties which can reduce inflammation resulting in accelerated wound healing. KCG and FUC were released sustainably from the blend nanofibers via the Korsmeyer-Peppas kinetics. MTT assays, live/dead staining and SEM images demonstrated the toxicity of KCG and FUC towards skin cancer MP 41 cells. In addition, MP 41 cells showed reduced metastatic potential when grown on KCG or FUC containing mats. Both KCG and FUC were non- cytotoxic to healthy L 929 fibroblast cells. In vivo studies on healthy Wistar rats confirmed the non-toxicity of the nanofibrous patches as well as their improved and scarless wound healing potential. In vivo studies on tumour xenograft model further showed a reduction of 7.15 % in tumour volume in only 4 days following application of the transdermal patch.


Assuntos
Melanoma , Nanofibras , Polissacarídeos , Ratos Wistar , Neoplasias Cutâneas , Alicerces Teciduais , Cicatrização , Animais , Cicatrização/efeitos dos fármacos , Nanofibras/química , Ratos , Neoplasias Cutâneas/patologia , Melanoma/patologia , Alicerces Teciduais/química , Polissacarídeos/farmacologia , Polissacarídeos/administração & dosagem , Camundongos , Linhagem Celular Tumoral , Carragenina/farmacologia , Humanos , Polidioxanona/farmacologia , Polidioxanona/química , Recidiva Local de Neoplasia/prevenção & controle , Recidiva Local de Neoplasia/patologia
4.
Skin Res Technol ; 30(4): e13681, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38584576

RESUMO

OBJECTIVE: Safe, effective, and biocompatible minimally invasive procedures with the potential to stimulate collagen production have been made to recover dermal thickness and skin quality. The main of this animal model experiment was to observe the effect of poly-L-lactic acid (PLLA) and polydioxanone (PDO) biostimulators in collagen I and III after hypodermal injection. METHODOLOGY: Sixteen adult female rats (Wistar) were randomized into four groups and had dorsal treatment with: G1: hypodermic subcision (HS) only; G2: HS and PLLA hypodermic injection (HI), G3: HS and PDO HI; G4: Control, with no treatment. RESULTS: In histochemical, it was observed hypodermal and dermal tissue in more organized thickness in G3 and in G4 when compared to G1 and G2. There was few difference in G1 compared to G4. The tissue of G2 showed irregularities in the arrangement of collagen fibers, less defined structure and lower distribution of type I collagen compared to the other groups. There is a greater tendency for the proportions of type III collagen among tissues treated with both biostimulators (G2 and G3). PLLA and PDO had relatively similar percentages of collagen when compared to G4. The amount of type I collagen was higher in tissues treated with subcision, while type III collagen was higher in tissues treated with both biostimulators. CONCLUSION: G3 showed better performance in collagen production, although small, when compared with G2.


Assuntos
Colágeno Tipo I , Polidioxanona , Poliésteres , Ratos , Feminino , Animais , Polidioxanona/farmacologia , Colágeno Tipo III , Ratos Wistar , Colágeno
5.
J Trauma Acute Care Surg ; 97(1): 149-157, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38595220

RESUMO

INTRODUCTION: Emergent laparotomy is associated with significant wound complications including surgical site infections (SSIs) and fascial dehiscence. Triclosan-coated barbed (TCB) suture for fascial closure has been shown to reduce local complications but primarily in elective settings. We sought to evaluate the effect of TCB emergency laparotomy fascial closure on major wound complications. METHODS: Adult patients undergoing emergency laparotomy were prospectively evaluated over 1 year. Patients were grouped into TCB versus polydioxanone (PDS) for fascial closure. Subanalysis was performed on patients undergoing single-stage laparotomy. Primary outcomes were SSI and fascial dehiscence. Multivariate analysis identified independent factors associated with SSI and fascial dehiscence. RESULTS: Of the 206 laparotomies, 73 (35%) were closed with TCB, and 133 (65%) were closed with PDS. Trauma was the reason for laparotomy in 73% of cases; damage-control laparotomy was performed in 27% of cases. The overall rate of SSI and fascial dehiscence was 18% and 10%, respectively. Operative strategy was similar between groups, including damage-control laparotomy, wound vac use, skin closure, and blood products. Surgical site infection events trended lower with TCB versus PDS closure (11% vs. 21%, p = 0.07), and fascial dehiscence was significantly lower with TCB versus PDS (4% vs. 14%, p < 0.05). Subanalysis of trauma and nontrauma cases showed no difference in SSI or fascial dehiscence. Multivariable analysis found that TCB decreased the likelihood of fascial dehiscence (odds ratio, 0.07; p < 0.05) following emergency laparotomy. Increased odds of fascial dehiscence were seen in damage-control laparotomy (odds ratio, 3.1; p < 0.05). CONCLUSION: Emergency laparotomy fascial closure with TCB showed significantly decreased rates of fascial dehiscence compared with closure with PDS and a strong trend toward lower SSI events. Triclosan-coated barbed suture was independently associated with decreased fascial dehiscence rates after emergency laparotomy. LEVEL OF EVIDENCE: Therapeutic/Care Management; Level III.


Assuntos
Laparotomia , Deiscência da Ferida Operatória , Infecção da Ferida Cirúrgica , Suturas , Triclosan , Humanos , Masculino , Feminino , Triclosan/administração & dosagem , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Laparotomia/métodos , Laparotomia/efeitos adversos , Deiscência da Ferida Operatória/prevenção & controle , Deiscência da Ferida Operatória/etiologia , Deiscência da Ferida Operatória/epidemiologia , Estudos Prospectivos , Pessoa de Meia-Idade , Adulto , Anti-Infecciosos Locais/administração & dosagem , Técnicas de Sutura/instrumentação , Polidioxanona , Resultado do Tratamento
6.
Biomolecules ; 14(4)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38672522

RESUMO

In this study, we introduce electrospun polydioxanone (PDO) nonwoven fabrics as a platform for the delivery of adeno-associated virus (AAV) vectors for transduction and genome editing by adhering them to organ surfaces, including the heart. AAV vectors were loaded onto the PDO fabrics by soaking the fabrics in a solution containing AAV vectors. In vitro, the amount of AAV vectors loaded onto the fabrics could be adjusted by changing their concentration in the solution, and the number of cells expressing the green fluorescent protein (GFP) encoded by the AAV vectors increased in correlation with the increasing amount of loaded AAV vectors. In vivo, both transduction and genome editing resulted in the observation of GFP expression around AAV vector-loaded PDO fabrics attached to the surfaces of mouse hearts, indicating effective transduction and expression at the target site. These results demonstrate the great potential of electrospun PDO nonwoven fabrics carrying therapeutic AAV vectors for gene therapy.


Assuntos
Dependovirus , Edição de Genes , Vetores Genéticos , Polidioxanona , Dependovirus/genética , Animais , Vetores Genéticos/genética , Polidioxanona/química , Edição de Genes/métodos , Camundongos , Humanos , Transdução Genética/métodos , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Células HEK293 , Terapia Genética/métodos , Miocárdio/metabolismo
7.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38471110

RESUMO

OBJECTIVES: To evaluate the biologic impact of polydioxanone (PDO) stenting in an animal model of inflammatory tracheal stenosis (TS). Additionally, to compare these results with those obtained in the same model without a stent and after placing one PDO stent in a healthy trachea. METHODS: 40 adult NZ rabbits were distributed into 3 groups: Group A, 8 animals with a healthy trachea and a PDO stent; group B, 17 rabbits with a TS and no stent; and group C, 15 animals with TS and a PDO stent. Histopathological studies included Masson's trichrome staining for submucosal fibrosis and Safranin O to assess structural integrity of cartilage. Morphometric analyses were performed in the 3 groups. RESULTS: Stent placement was successful in every case. Histological studies did not show a significant increase in tracheal wall collagen area and cartilage structure was not modified in those rabbits with a PDO stent, even in a TS scenario. Stent implantation permitted recovery of normal tracheal lumen levels in the TS model. CONCLUSIONS: PDO stenting in the normal trachea and in a model of TS neither caused increase in the collagen matrix nor modification of the cartilaginous support. Additionally, radial force exhibited by PDO stents was effective in restoring normal tracheal lumen when placed in a stenotic lesion. These findings suggest that they may be safe and useful in the setting of an acquired TS.


Assuntos
Estenose Traqueal , Animais , Coelhos , Estenose Traqueal/cirurgia , Polidioxanona , Traqueia/cirurgia , Modelos Teóricos , Stents , Colágeno
8.
Aesthetic Plast Surg ; 48(9): 1706-1714, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38519570

RESUMO

BACKGROUND: Traditional facial aging surgeries have risks and extended recovery times, leading to a demand for minimally invasive alternatives. PDO (polydioxanone) threads, which are absorbable sutures that stimulate collagen production and tissue contraction, offer improved aesthetic outcomes. This paper evaluates the combined use of PDO thread mid-cheek lift and lower blepharoplasty for facial rejuvenation. METHODS: This retrospective study compared outcomes in patients undergoing lower blepharoplasty combined with a mid-face lift using PDO threads versus those undergoing only lower blepharoplasty. Focused on individuals with baggy lower eyelids and pronounced nasolabial folds, outcome measures included the Modified Fitzpatrick wrinkle scale, Allergan® midface volume deficit scale, Width of inter zygomatic distance, Patient and Observer Scar Assessment Scale, and patient satisfaction questionnaires, assessed at baseline, 3 months, and 1 year postoperatively. RESULTS: The combined procedure demonstrated superior aesthetic outcomes and higher patient satisfaction compared to lower blepharoplasty alone. Improvements were more significant in wrinkle reduction, midface volume, and inter-zygomatic distance in the combined procedure group. Although the combined procedure had a longer mean operation time, scar assessment scores were similar between both groups, with no complications reported. CONCLUSION: The combination of lower blepharoplasty and mid-face lift using PDO threads is a comprehensive and effective approach for facial rejuvenation. It significantly enhances wrinkle reduction, mid-face lifting, and patient satisfaction. Ultrasound-guided thread lifting, a method of assessing and performing mid-face lifting, proves to be safe and efficient. This approach holds promise as a future option in cosmetic anti-aging surgery, presenting a minimally invasive alternative with natural-looking results and reduced downtime. LEVEL OF EVIDENCE II: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://link.springer.com/journal/00266 .


Assuntos
Blefaroplastia , Satisfação do Paciente , Polidioxanona , Rejuvenescimento , Ritidoplastia , Envelhecimento da Pele , Humanos , Blefaroplastia/métodos , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Ritidoplastia/métodos , Masculino , Resultado do Tratamento , Estética , Idoso , Adulto , Técnicas de Sutura , Suturas , Estudos de Coortes
9.
Am J Otolaryngol ; 45(3): 104240, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38447465

RESUMO

PURPOSE: To systematically reviews the safety and effectiveness of alloplastic implants (AI) in septoplasty. METHODS: We conducted a comprehensive search in Medline, EMBASE, SCOPUS, CINAHL, and Cochrane Library databases to identify articles on septoplasty using AI. We also manually searched reference lists of included articles. Inclusion criteria involved prospective or retrospective case-series studies of adults with deviated nasal septum (DNS) who underwent septoplasty with AI, with sufficient follow-up data. Two authors independently screened articles, reviewed full manuscripts, and extracted data. RESULTS: Out of 5370 articles, 16 met inclusion criteria, encompassing 884 patients from 14 eligible studies. Most studies had fair quality. AI materials included Polydioxanone (PDS), Polycaprolactone (PCL), Titanium, Macropore, and PolyMax. AI usage improved nasal obstruction in most patients, with 95.6 % (84.8 %-100 %) based on physical examination and 96.9 % (89.6 %-100 %) based on symptoms. AI-related complications occurred in 4.3 % (0 %-12.8 %) of cases, mostly non-serious. CONCLUSIONS: AI use can be considered as a useful adjunct in septoplasty, with uncommon complications similar to standard procedures. However, due to limited-quality evidence, further prospective controlled studies are needed.


Assuntos
Septo Nasal , Próteses e Implantes , Rinoplastia , Humanos , Septo Nasal/cirurgia , Rinoplastia/métodos , Resultado do Tratamento , Obstrução Nasal/cirurgia , Polidioxanona , Adulto , Masculino , Feminino , Poliésteres
10.
Skin Res Technol ; 30(3): e13617, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38444188

RESUMO

INTRODUCTION: The prevalence of horizontal neck lines as a cosmetic concern is widely acknowledged, yet the available treatment options are limited, and no studies have investigated the use of polydioxanone-barbed threads. These threads, characterized by a finely braided structure, function as a scaffold to attract regenerative factors and facilitate the migration and proliferation of cells. This study aims to evaluate the outcomes of concurrent application of braided polydioxanone-barbed threads for addressing horizontal neck wrinkles. METHODOLOGY: A retrospective case series involving four female participants (aged 41, 43, 45, and 46) treated with polydioxanone-barbed threads for horizontal neck wrinkles between January 2023 and July 2023 was conducted. Adult patients were assessed at an 8-week follow-up, revealing a significant reduction in wrinkle intensity based on the Horizontal Neck Wrinkle Severity Scale. RESULTS: The analysis of horizontal neck lines demonstrated a notable decrease in wrinkle intensity according to the Horizontal Neck Wrinkle Severity Scale at the 8-week mark, and this improvement maintained statistical significance. Both patient Global Aesthetic Improvement Scale (GAIS) scores (90%-100%) and physician GAIS scores (100%) were rated as excellent. CONCLUSION: The subdermal application of polydioxanone-barbed threads for horizontal neck lines proves to be a secure and efficacious approach for treating horizontal neck wrinkles, with no observed Tyndall effect. This technique shows promise for rejuvenating the skin in the horizontal neckline region.


Assuntos
Polidioxanona , Pele , Adulto , Humanos , Feminino , Estudos Retrospectivos , Estética , Software
11.
Dermatol Surg ; 50(4): 360-365, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38318968

RESUMO

BACKGROUND: Using a thread for wound closure promotes healing and minimizes contamination by foreign substances. Threads have also been employed in esthetic surgery; however, functional threads that can improve wrinkles and rejuvenate the skin are required. OBJECTIVE: To evaluate the suitability of polydioxanone threads coated with polyethylene glycol, hyaluronic acid, and amino acids for use in the medical field because such formulations are expected to promote regeneration and collagen synthesis. MATERIALS AND METHODS: Physical properties (diameter [ n = 20], tensile strength [ n = 20], strength retention rate [ n = 10], and scanning electron microscopy images) and cytotoxicity (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide and lactate dehydrogenase assays) of polydioxanone threads coated with polyethylene glycol, hyaluronic acid, and amino acids were assessed and compared with those of uncoated polydioxanone threads. Analyses were performed using IBM SPSS Statistics (Statistical significance; p values <.05). RESULTS: The size standards for tensile strength (≥63.5 N) and diameter (average 0.570-0.610 mm) were met. There were no differences in the physical properties of the coated and uncoated threads; however, the biocompatibility of coated threads was high owing to low cytotoxicity. CONCLUSION: Threads coated with materials that can promote regeneration are suitable for use in the medical field.


Assuntos
Polidioxanona , Ritidoplastia , Humanos , Ácido Hialurônico , Ritidoplastia/métodos , Aminoácidos , Polietilenoglicóis , Suturas
13.
Ann Otol Rhinol Laryngol ; 133(1): 63-68, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38161289

RESUMO

BACKGROUND: Surgical repair of septal perforations has been historically cumbersome. Recently described techniques utilizing interposition grafting with polydioxanone (PDS) plates wrapped in a temporoparietal fascia (TPF) graft have reported successful closure in 90% to 100% of cases. Our objective is to expand the investigation into the use of interposition grafts of polydioxanone plates combined with a temporoparietal fascia graft for nasal septal perforation repair. METHODS: Retrospective review of the medical record was performed for all septal perforation repairs using the TPF-PDS plate interposition graft technique from August 1, 2017 to March 1, 2021 at the University of Iowa. Minimum post-operative follow-up was 1 month. RESULTS: Our series included 31 patients with symptomatic nasal septal perforations. Thirteen patients underwent open while 18 patients underwent endonasal graft placement. The mean perforation size was 1.49 cm2. The mean post-operative follow-up was 11.5 months. CONCLUSIONS: Repair of symptomatic nasal septal perforations using an interposition graft of polydioxanone plate wrapped in temporoparietal fascia demonstrated an overall success rate of 90%.


Assuntos
Perfuração do Septo Nasal , Rinoplastia , Humanos , Perfuração do Septo Nasal/cirurgia , Polidioxanona , Fáscia/transplante , Estudos Retrospectivos , Septo Nasal/cirurgia , Rinoplastia/métodos , Resultado do Tratamento
14.
Medicina (Kaunas) ; 60(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38256351

RESUMO

Objective: To compare the vaginal cuff dehiscence (VCD) rates using Vicryl (Poliglactyn 910) and Polydioxanone (PDS) in patients who underwent laparoscopic hysterectomy. Materials and methods: A retrospective, monocentric study was conducted, including all patients undergoing laparoscopic hysterectomy at the Department of Obstetrics and Gynaecology, Azienda di Rilievo Nazionale e di Alta Specializzazione (ARNAS) Garibaldi Nesima, Catania, between January 2014 and December 2021. Patients underwent hysterectomy for benign gynecologic pathologies (endometriosis, leiomyomas, or benign pelvic pathologies) or malignant gynecologic pathologies (endometrium cancer, complex endometrial hyperplasia, ovarian cancer, cervix cancer, or uterine carcinosarcoma). The Z-score calculation was performed to find eventual statistically significant differences between the two populations regarding VCD rates. Results: Laparoscopic vaginal cuff closure was performed, with Vicryl sutures in 202 patients and PDS sutures in 184 women. Demographic and baseline characteristics were not significantly different in the two groups. VCD occurred in three patients in the Vicryl group and did not occur in the PDS group. The three cases of VCD were precipitated by intercourses that occurred within 90 days of surgery. However, there was not a significant statistical difference between the two groups regarding VCD (p = 0.09). Conclusions: Vicryl and PDS sutures seem to be similar for vaginal cuff closure in laparoscopic hysterectomy. The VCD rate was low, and the observed differences between the Vicryl and PDS groups did not reach statistical significance. Further research through prospective studies is essential.


Assuntos
Laparoscopia , Polidioxanona , Gravidez , Feminino , Humanos , Polidioxanona/uso terapêutico , Poliglactina 910/uso terapêutico , Estudos Prospectivos , Estudos Retrospectivos , Laparoscopia/efeitos adversos , Histerectomia/efeitos adversos
15.
Biochem Biophys Res Commun ; 698: 149549, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38266311

RESUMO

A recently established therapeutic strategy, involving the insertion of biodegradable cog polydioxanone filaments into the quadriceps muscles using the Muscle Enhancement and Support Therapy (MEST) device, has demonstrated significant efficacy in alleviating knee osteoarthritis (OA) pain. This study investigated changes in peripheral sensitization as the potential mechanism underlying MEST-induced pain relief in monoiodoacetate (MIA) induced OA rats. The results revealed that MEST treatment potently reduces MIA-induced sensitization of L3/L4 dorsal root ganglion (DRG) neurons, the primary nociceptor pathway for the knee joint. This reduction in DRG sensitization, as elucidated by voltage-sensitive dye imaging, is accompanied by a diminished overexpression of TRPA1 and NaV1.7, key nociceptor receptors involved in mechanical pain perception. Importantly, these observed alterations strongly correlate with a decrease in mechanically-evoked pain behaviors, providing compelling neurophysiological evidence that MEST treatment alleviates OA pain by suppressing peripheral sensitization.


Assuntos
Osteoartrite do Joelho , Ratos , Animais , Osteoartrite do Joelho/metabolismo , Ratos Sprague-Dawley , Polidioxanona/metabolismo , Músculo Quadríceps/metabolismo , Dor/tratamento farmacológico , Dor/metabolismo , Modelos Animais de Doenças , Gânglios Espinais/metabolismo
16.
Hernia ; 28(2): 527-535, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38212505

RESUMO

PURPOSE: Using small instead of large bites for laparotomy closure results in lower incidence of incisional hernia, but no consensus exists on which suture material to use. This study aimed to compare five different closure strategies in a standardized experimental setting. METHODS: Fifty porcine abdominal walls were arranged into 5 groups: (A) running 2/0 polydioxanone; (B) interlocking 2/0 polydioxanone; (C) running size 0 barbed polydioxanone; (D) running size 0 barbed glycolic acid and trimethylene carbonate; (E) running size 0 suturable polypropylene mesh. The small-bites technique was used for linea alba closure in all. The abdominal walls were divided into a supra- and infra-umbilical half, resulting in 20 specimens per group that were pulled apart in a tensile testing machine. Maximum tensile force and types of suture failure were registered. RESULTS: The highest tensile force was measured when using barbed polydioxanone (334.8 N ± 157.0), but differences did not reach statistical significance. Infra-umbilical abdominal walls endured a significantly higher maximum tensile force compared to supra-umbilical (397 N vs 271 N, p < 0.001). Barbed glycolic acid and trimethylene carbonate failed significantly more often (25% vs 0%, p = 0.008). CONCLUSION: Based on tensile force, both interlocking and running suture techniques using polydioxanone, and running sutures using barbed polydioxanone or suturable mesh, seem to be suitable for abdominal wall closure. Tensile strength was significantly higher in infra-umbilical abdominal walls compared to supra-umbilical. Barbed glycolic acid and trimethylene carbonate should probably be discouraged for fascial closure, because of increased risk of suture failure.


Assuntos
Parede Abdominal , Técnicas de Fechamento de Ferimentos Abdominais , Glicolatos , Suínos , Animais , Parede Abdominal/cirurgia , Polidioxanona , Herniorrafia , Técnicas de Sutura/efeitos adversos , Modelos Animais , Resistência à Tração , Laparotomia , Suturas , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos
17.
Int J Biol Macromol ; 259(Pt 1): 129218, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38185297

RESUMO

Nanofibers for drug delivery systems have gained much attention during the past years. This paper describes for the first time the loading of a bioactive precipitate (JAD) from the marine sponge Jaspis diastra in PDX and fucoidan-PDX. JAD was characterized by LC-MS/MS and the major component was jaspamide (1) with a purity of 62.66 %. The cytotoxicity of JAD was compared with paclitaxel (PTX). JAD and PTX displayed IC50 values of 1.10 ± 0.7 µg/mL and 0.21 ± 0.12 µg/mL on skin fibroblasts L929 cells whilst their IC50 values on uveal MP41 cancer cells, were 2.10 ± 0.55 µg/mL and 1.38 ± 0.68 µg/mL, respectively. JAD was found to be less cytotoxic to healthy fibroblasts compared to PTX. JAD and PTX loaded scaffolds showed sustained release over 96 h in physiological medium which is likely to reduce the secondary cytotoxic effect induced by JAD and PTX alone. The physico-chemical properties of the loaded and unloaded scaffolds together with their degradation and action on tumor microenvironment by using L929 and MP41 cells were investigated. JAD and PTX at a concentration of 0.5 % (drug/polymer, w/w) in the electrospun mats prevented growth and proliferation of L929 and MP41 cells. Co-culture of L929 and MP41 showed that the JAD and PTX loaded mats inhibited the growth of both cells and caused cell death.


Assuntos
Antineoplásicos , Nanofibras , Neoplasias , Polissacarídeos , Poríferos , Animais , Paclitaxel/farmacologia , Paclitaxel/química , Polidioxanona/química , Nanofibras/química , Cromatografia Líquida , Espectrometria de Massas em Tandem , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Microambiente Tumoral
18.
Tissue Eng Part C Methods ; 30(3): 102-112, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38271574

RESUMO

The aim of this study was to assess the bone regeneration potential of a polydioxanone (PDO) scaffold together with recombinant human bone morphogenetic protein-2 (rhBMP-2) for the reconstruction of large bone defect. In total, 24 male rats (6 months old) were subjected to bilateral femoral stabilization using titanium plates to create a 2 mm gap, and reconstruction using rhBMP-2 (Infuse®; 3.25 µg). The bone defects were covered with PDO (PDO group), or with titanium mesh (Ti group). Animals were euthanized on days 14 and 60. Simultaneously, 16 rats received PDO and Ti in their dorsum for the purpose of biocompatibility analysis at 3, 5, 7, and 10 days postoperatively. X-ray densitometry showed a higher density in the PDO group on day 14. On day 60, coverage of the bone defect with PDO showed a larger quantity of newly formed bone than that found for the Ti group, a lower inflammatory infiltrate value, and a more significant number of blood vessels on day 14. By immunohistochemical assessment, runt-related transcription factor 2 (RUNX2) and osteocalcin (OCN) showed higher labeling on day 14 in the PDO group. On day 60, bone morphogenetic protein-2 (BMP-2) showed higher labeling in the PDO group, whereas Ti showed higher labeling for osteoprotegerin, nuclear factor kappa B ligand-activating receptor, RUNX2, and OCN. Furthermore, biocompatibility analysis showed a higher inflammatory response in the Ti group. The PDO scaffold enhanced bone regeneration when associated with rhBMP-2 in rat femur reconstruction. Impact statement Regeneration of segmental bone defects is a difficult task, and several techniques and materials have been used. Recent advances in the production of synthetic polymers, such as polydioxanone (PDO), produced by three-dimensional printing, have shown distinct characteristics that could improve tissue regeneration even in an important bone defect. The present preclinical study showed that PDO membranes used as scaffolds to carry recombinant human bone morphogenetic protein-2 (rhBMP-2) improved bone tissue regeneration by more than 8-fold when compared with titanium mesh, suggesting that PDO membranes could be a feasible and useful material for use in guided bone regeneration. (In English, viable is only used for living creatures capable of sustaining life.


Assuntos
Subunidade alfa 1 de Fator de Ligação ao Core , Polidioxanona , Masculino , Ratos , Humanos , Animais , Lactente , Polidioxanona/farmacologia , Titânio , Proteína Morfogenética Óssea 2/farmacologia , Fator de Crescimento Transformador beta/farmacologia , Regeneração Óssea , Proteínas Recombinantes/farmacologia , Fêmur/diagnóstico por imagem
19.
J Cosmet Dermatol ; 23(2): 658-665, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37644781

RESUMO

BACKGROUND: Polydioxanone (PDO) threads have been widely used to tighten and lift the facial soft tissue. OBJECTIVE: This research aims to determine the collagenation and inflammation changes that occur in the adipose tissue over time when different types of threads are implanted. METHODS & MATERIALS: Three threads types, PDO, poly glycolic-co-lactic acid (PGLA), and nylon, were inserted in the subcutaneous fat of 12-month-old Bama miniature pigs. Collagen production and inflammatory response were evaluated by hematoxylin and eosin and Masson trichrome staining at 1, 4, 12, 24, and 48 weeks. RESULTS: The integrity of the PDO thread lasted up to 24 weeks with mild inflammation and collagen production. The PGLA thread integrity lasted until 12 weeks and had a strong inflammatory response. The nylon thread's integrity was maintained for 48 weeks and showed minor inflammation and collagen production. CONCLUSION: Our data suggest that PDO thread is the best choice for clinicians, as it has a mild action process with minimal irritation, moderate collagen production, a reasonable explanation time, with obvious bridging fibrous tissue, and thickening action for the superficial fascia.


Assuntos
Polidioxanona , Ritidoplastia , Suínos , Animais , Nylons , Ritidoplastia/métodos , Colágeno , Inflamação
20.
J Cosmet Dermatol ; 23(1): 199-206, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37539496

RESUMO

OBJECTIVE: To demonstrate the effects of PDO threads non-surgical rhinoplasty on patients' quality of life (using FACE-Q Scale) and first impression assessments. METHODS: This is a prospective cohort study of 10 adult patients who sought non surgical rhinoplasty to improve tip rotation or reduce the appearance of a dorsal hump. All patients fulfilled the study's enrollment criteria. Prior to treatment, patients completed pre-treatment FACE-Q surveys and pre-treatment photos were obtained. Each patient was treated with the appropriate size and number of PDO threads necessary to achieve optimal correction result (OCR). Two weeks after treatment, the patient completed posttreatment FACE-Q surveys and posttreatment photos were obtained and analyzed. First impression surveys were created using pre- and posttreatment photos, and the survey was completed by 146 blinded evaluators. RESULTS: There was statistically significant improvement in the FACE-Q scores for social function (p = 0.02), psychological function (p = 0.0009) and satisfaction with nose (p = 0.0001). There was significant reduction in scores for appearance related psychosocial distress (p = 0.03). For the first impression surveys, there was a statistically significant improvement (p = 0.029) in the attractiveness scale posttreatment. Although not statistically significant, there was reduction of the dorsal hump (p = 0.15) and increase in the nasolabial angle (p = 0.48) and Goode's ratio (p = 0.16). There were no major adverse events or complications. CONCLUSION: This study shows that the PDO threads alone can be used safely to achieve minor nasal changes especially in tip rotation and appearance of dorsal hump, to improve patients' quality of life, and perceived attractiveness of treated patients.


Assuntos
Rinoplastia , Adulto , Humanos , Rinoplastia/efeitos adversos , Polidioxanona , Qualidade de Vida , Estudos Prospectivos , Nariz/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...