Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 18.132
Filtrar
1.
Int J Mol Sci ; 25(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38928462

RESUMO

Galectins are a family of beta-galactoside-binding proteins that are characterised by their carbohydrate recognition domain (CRD) and include galectin-1 and galectin-3. These galectins have been implicated in numerous diseases due to their pleiotropic nature, including cancer and fibrosis, with therapeutic inhibitors being clinically developed to block the CRD. One of the early methods developed to characterise these galectins was the hemagglutination of red blood cells. Although it is insightful, this approach has been hampered by a lack of sensitivity and accurate quantification of the agglutination observed. In this study, we aimed to validate a more precise and quantitative method to enable the further investigation of differences between galectins in respect to agglutination induction in different blood groups, as well as the characterisation of small molecule inhibitors. Quantification of hemagglutination was shown to be optimal using U-bottom plates imaged and analysed with FIJI ImageJ rather than flat-bottom plates read for absorbance on an optical density plate reader. Galectin-3-induced red blood cell agglutination efficacy increased significantly from blood group O to A to B. However, for both the galectin-1 monomer and concatemer, a more comparable effect was observed between blood group B and O, but with more potent effects than in blood group A. Inhibition assays for both galectin-3 and galectin-1 induced-hemagglutination were able to demonstrate clear concentration responses and expected selectivity profiles for a set of small-molecule glycomimetics, confirming the historical profiles obtained in biochemical binding and functional cellular assays.


Assuntos
Eritrócitos , Galectina 1 , Galectinas , Hemaglutinação , Humanos , Eritrócitos/metabolismo , Eritrócitos/efeitos dos fármacos , Hemaglutinação/efeitos dos fármacos , Galectinas/antagonistas & inibidores , Galectinas/metabolismo , Galectina 1/antagonistas & inibidores , Galectina 1/metabolismo , Galectina 3/antagonistas & inibidores , Galectina 3/metabolismo , Testes de Aglutinação/métodos , Testes de Hemaglutinação , Aglutinação/efeitos dos fármacos
2.
Acta Parasitol ; 69(2): 1122-1131, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38551763

RESUMO

PURPOSE: Cystic echinococcosis (CE) is caused by the larval form of Echinococcus granulosus. Clinical, radiologic, pathologic, and serologic findings should be evaluated together for the diagnosis of CE. The sensitivity and specificity oalf serologic tests may vary depending on the method used. In this study, we aimed to detect IgG antibodies specific to E. granulosus using indirect hemagglutination assay (IHA), enzyme-linked immunosorbent assay (ELISA), indirect fluorescent antibodies (IFA) and western blot (WB) tests. METHODS: In our study, the serum samples of 74 patients sent to our laboratory with suspicion of CE were studied using two different commercial IHA tests, ELISA, IFA and WB test. The test results were evaluated along with radiological findings and histopathological examinations, the latter being the gold standard. RESULTS: Of all the patients, 51 (69%) were female and 23 (31%) were male. There was a statistically significant difference between males and females (χ2 = 9.7, p = 0.002). Out of 74 patients, positivity rates for Siemens IHA, Fumouze IHA, ELISA, IFA and WB test were positive as 33 (44.6%), 35 (47.3%), 43 (58.1%), 42 (56.7%) and 38 (51.3%), respectively. The sensitivity and specificity of the tests were as follows: 66.67 and 2.31% for Siemens IHA; 70.83% and 96.15% for Fumouze IHA; 85.42%, and 88.46% for ELISA; 83.33% and 88.46% for IFA; 72.92% and 88.46% for WB test. CONCLUSION: There were statistically significant differences in between all five methods (p < 0,001). While the tests with the highest specificity was Fumouze IHA, the test with the highest sensitivity was the ELISA test. It was concluded that IHA and ELISA tests were more practical in practice because of their greater applicability.


Assuntos
Anticorpos Anti-Helmínticos , Equinococose , Echinococcus granulosus , Ensaio de Imunoadsorção Enzimática , Testes de Hemaglutinação , Imunoglobulina G , Sensibilidade e Especificidade , Testes Sorológicos , Humanos , Equinococose/diagnóstico , Equinococose/sangue , Feminino , Masculino , Echinococcus granulosus/imunologia , Animais , Anticorpos Anti-Helmínticos/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Testes Sorológicos/métodos , Adulto , Pessoa de Meia-Idade , Imunoglobulina G/sangue , Western Blotting , Técnica Indireta de Fluorescência para Anticorpo , Adulto Jovem , Adolescente , Idoso , Criança
3.
Rev. chil. infectol ; 40(6): 634-641, dic. 2023. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1529993

RESUMO

INTRODUCCIÓN: La inmunoquimioluminiscencia de micropartículas (CMIA), no es recomendada en el día de hoy para el tamizaje ni confirmación de sífilis en pacientes, las guías chilenas recomiendan tamizaje con V.D.R.L y confirmación con hemaglutinación. OBJETIVO: Determinar la especificidad, sensibilidad y correlación diagnóstica de esta técnica respecto a la prueba treponémica de uso habitual. MATERIALES Y MÉTODOS: De 815 muestras obtenidas en un periodo de 6 meses, a todas las cuales se les aplicó las pruebas de VDRL, MHA-TP y CMIA, 484 muestras fueron positivas para MHA-TP. Se determinó el rendimiento, se graficaron las curvas ROC, índice de correlación y punto de corte óptimo. RESULTADOS: La CMIA. demostró una sensibilidad de 100%, especificidad: 94,6%, VPN: 100% y VPP: 96.4% y una eficiencia de 97,8% con respecto al MHA-TP, con un índice de correlación: 0,97 y un punto de corte de 7.665, de modo que toda muestra con una CMIA. sobre este valor no necesitaría de una segunda prueba treponémica para su confirmación. El 7,11% tuvo valores intermedios de CMIA (1.0 a 7.664). CONCLUSIÓN: La CMIA. es una técnica automatizada altamente sensible y específica, equiparable al MHA-TP. Aplicada como prueba inicial de testeo para sífilis incrementa la certeza diagnóstica y podría permitir el diagnóstico precoz de la enfermedad.


BACKGROUND: The chemiluminescent microparticle immunoassay (CMIA) is not recommended for screening or confirmation of syphilis in patients, Chilean guidelines recommend screening with VDRL and confirmation with hemagglutination. AIM: To determine the specificity, sensitivity, and diagnostic correlation of this technique compared to the usual treponemal test. METHODS: Of the 815 samples obtained over a period of 6 months, all of which were subjected to VDRL, MHATP, and CMIA. testing, 484 samples were positive for MHA-TP. The performance was determined, ROC curves were graphed, correlation index and optimal cutoff point were determined. RESULTS: CMIA showed a sensitivity of 100%, specificity of 94.6%, NPV of 100%, PPV of 96.4%, and an efficiency of 97.8% compared to MHA-TP, with a correlation index of 0.97 and a cutoff point of 7.665, such that any sample with a CMIA. value above this value would not require a second treponemal test for confirmation. 7.11% had intermediate CMIA. values (1.0 to 7.664). CONCLUSION: CMIA. is a highly sensitive and specific automated technique comparable to MHA-TP. When applied as an initial screening test for syphilis, it increases diagnostic certainty and may allow for early diagnosis of the disease.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Imunoensaio , Sífilis/diagnóstico , Medições Luminescentes/métodos , Algoritmos , Testes de Hemaglutinação , Sorodiagnóstico da Sífilis , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade , Reações Falso-Positivas
4.
Mol Biol (Mosk) ; 57(5): 898-906, 2023.
Artigo em Russo | MEDLINE | ID: mdl-37752655

RESUMO

As an alternative to the classical method of erythrocyte hemagglutination, a latex agglutination assay based on the interaction of influenza viruses with the sialoglycoprotein fetuin immobilized on the surface of polystyrene microspheres has been developed. Twelve influenza A virus strains of different subtypes and two influenza B viruses of different lines were tested. Simultaneous titration of viruses using the classical hemagglutination test and the proposed latex agglutination assay showed similar sensitivity and a high degree of correlation (R = 0.94). The obtained microspheres can be used for titration of viruses that recognize and bind sialylated glycans as receptors. In particular, latex aggregation was also induced by the Newcastle disease virus.


Assuntos
Vírus da Influenza A , Orthomyxoviridae , Animais , Hemaglutinação , Testes de Fixação do Látex , Testes de Hemaglutinação
5.
Turkiye Parazitol Derg ; 47(3): 166-170, 2023 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-37724366

RESUMO

OBJECTIVE: Cystic echinococcosis (CE) is one of the neglected tropical diseases announced by the World Health Organization. In the period entered with the Coronavirus disease-2019 pandemic, the fight against such diseases has become even more difficult. In our study, we aimed to make inferences about the effects of the pandemic on the diagnosis of the disease by evaluating the number and results of CE indirect hemagglutination test (IHA) before and during the pandemic. METHODS: The number of IHA test requests and positivity rates in the 30-month periods before and after March 11, 2020, when the first case was seen in our country, were evaluated retrospectively. Statistical analysis was made with SPSS version 23 (SPSS, Chicago, IL, USA) program. RESULTS: The results of 1444 patients before the pandemic and 870 patients during the pandemic period were examined. The difference between IHA positivity rates, which was found to be 18.49% before the pandemic and 14.6% during the pandemic, was statistically significant (p=0.016). The positivity rates of women and men were found to be statistically similar in both periods (pbefore=0.621, pafter=0.238). The age group with the highest IHA positivity rate was 20-39 in both periods, and the difference between the positivity rates of the age groups was statistically significant (p<0.001). CONCLUSION: A significant decrease was observed in the rate of IHA positivity during the pandemic period. The status of no increase in positivity rates despite a significant decrease in IHA tests makes us think that the diagnosis may be missed in some patients or that there could be disruptions in their follow-up. For this reason, in order to continue the fight successfully against CE, which is an important public health problem for our country, early diagnosis and regular follow-ups should be emphasized with educations, and the laboratory-clinician communication should be strengthened in order to use tests more efficiently.


Assuntos
COVID-19 , Equinococose , Masculino , Humanos , Feminino , COVID-19/diagnóstico , COVID-19/epidemiologia , Pandemias , Estudos Retrospectivos , Equinococose/diagnóstico , Equinococose/epidemiologia , Testes de Hemaglutinação
6.
PLoS One ; 17(11): e0277236, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36342931

RESUMO

The decline in the population of ring-necked pheasants (Phasianus colchicus) in northwestern Germany since 2007 raises questions about the underlying causes. We therefore studied the growth and immune status of ring-necked pheasant chicks dependent on different feed composition. Here, 490 ring-necked pheasant chicks were raised in five groups up to nine weeks. While control groups C1 and C2 received sufficient crude protein (28%) and energy (12.5 MJ/Kg feed) according to current standards, group C2 was treated with cyclosporine eight hours prior to phythemagglutination (PHA) testing, serving as a positive immune suppressed control. Group V1 was fed with reduced protein (20%) but optimal energy content (12.5 MJ/Kg feed), group V2 was fed with sufficient protein (28%) and reduced energy content (10 MJ/kg feed) whereas group V3 was fed reduced crude protein (20%) and reduced energy content (10MJ/kg feed). On all chicks, health status was checked each week, and 20 birds of each group were weighed randomly per week. PHA-testing was performed on 12 birds of each group to study the in vivo non-specific activation of lymphocytes at week 2, 4, 6, 7, 8 and 9. In addition, hemolysis-hemagglutination-assay (HHA) was performed on each of the PHA-tested chicks, which were subsequently euthanized and dissected. Histopathologic examinations of 5 birds that were randomly chosen were performed. The PHA-test results demonstrate significant differences between control (C1, C2) and experimental groups (V1-V3) in several developmental stages. According to the HHA results, weekly testing detected a significant increase of titres per week in all groups without significant differences. Here, only hemagglutination and no lysis of samples was observed. It seems appropriate to conclude that during their first weeks of life, protein content is of higher importance in ring-necked pheasant chicks than energy intake. In particular T-cell response is significantly reduced, which indicate a weaker immune system resulting in a higher risk for clinical diseases. Therefore, we assume that protein i.e. insect availability is a highly important co-factor in the free-ranging population dynamics, and is linked to declines of the northwestern German population.


Assuntos
Galliformes , Codorniz , Animais , Galinhas , Alimentos , Testes de Hemaglutinação , Sistema Imunitário
7.
J Pak Med Assoc ; 72(6): 1035-1038, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35751304

RESUMO

OBJECTIVE: This study aims to evaluate the serological, radiological and epidemiological analysis of suspected cystic echinococcosis patients, and to assess the positivity rate in the region. Methods: The retrospective study was conducted at Bursa Uludag University Hospital, Turkey and comprised data from January 2009 to December 2017 related to patients of either gender with suspected cystic echinococcosis who underwent indirect haemagglutination testing. Demographic and clinical data of patients who tested positive were analysed. Statistical analysis was done using SPSS 23. RESULTS: Of the 3910 patients with a mean age of 41.6±19.35 years (range: 0-93 years) who underwent indirect haemagglutination testing, 692(17.7%) tested positive; 390(56.4%) females, and 302(43.6%) males. The highest seropositivity rate 107(15.5%) was observed in 2011, followed by 104(15%) in 2016. Seropositive cases were predominantly seen in those aged 40-49 years 131 (18.9%), followed by those aged 50-59 years 124 (17.9%). CONCLUSIONS: Cystic echinococcosis was found to be a public health problem in South Marmara region of Turkey.


Assuntos
Equinococose , Adulto , Equinococose/diagnóstico , Equinococose/epidemiologia , Feminino , Testes de Hemaglutinação/métodos , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Saúde Pública , Estudos Retrospectivos , Adulto Jovem
8.
Turkiye Parazitol Derg ; 46(2): 133-139, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35604192

RESUMO

Objective: Cystic echinococcosis (CE) is a parasitic disease that has been known for years in helminth diseases and it is important as human and animal health problem in many parts of the world and in our country due to economic losses. In this study, it was aimed to retrospectively evaluate the distribution of anti-E. granulosus-IgG antibodies in patients with pre-diagnosis of CE that referred to parasitology laboratory between January 2013-December 2018. Methods: Commercial kit was used for indirect hemaglutination (IHA), indirect fluorescent antibody test (IFAT) and Western blot (WB) methods using sera from patient samples was applied according to the kit proposal. In addition, patient materials for CAM, CSF and blood for which polymerase chain reaction (PCR)/QPCR tests were requested were examined. Results: Sera of the patients who were tested with at least one of the IHA, IFAT and WB methods or a combination of these methods, and 443 cases out of 2.283 cases were found to be E. granulosus seropositive. It was determined that 369 (62.03%) of 443 positive patients were female and 330 (37.97%) were male patients. Among these patients, 87 patients whose IFAT and/or IHA tests were negative were found to have positive results with the WB method. IFAT or IHA test results of 13 patients with negative WB tests were found to be positive. Four patients were identified with both tests positive but WB test results negative. In addition, 36 of 72 patients who underwent PCR/QPCR tests were found to be positive. Conclusion: As a result of a six-year retrospective screening, 22% of the cases were found to be positive, and it was concluded that the prevalence of CE is high and the use of a single test may be insufficient in the diagnosis of CE, therefore, test combinations will increase the sensitivity and reliability in reaching the correct diagnosis.


Assuntos
Equinococose , Echinococcus granulosus , Animais , Anticorpos Anti-Helmínticos , Equinococose/diagnóstico , Equinococose/epidemiologia , Equinococose/parasitologia , Ensaio de Imunoadsorção Enzimática , Docentes , Feminino , Testes de Hemaglutinação , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Universidades
9.
Sex Transm Dis ; 49(6): 453-457, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35312664

RESUMO

BACKGROUND: Automated chemiluminescent microparticle immunoassays (CMIAs) are the most common first step at high-volume laboratories for syphilis screening. If the initial screening test is reactive, 1 more treponemal test is required, resulting in increased cost. In this multicenter study, we aimed to determine the correlation between the CMIA signal-to-cutoff ratio (S/Co) and the confirmatory tests to reduce unnecessary confirmatory testing. METHODS: Eight hospitals from 5 provinces participated in this study. All laboratories used Architect Syphilis TP CMIA (Abbott Diagnostics, Abbott Park, IL) for initial screening. Treponema pallidum hemagglutination (TPHA), rapid plasma reagin (RPR), and fluorescent treponemal antibody absorption (FTA-ABS) were used as confirmatory tests according to the reverse or European Centre for Disease Prevention and Control algorithms. A receiver operating characteristic analysis was used to determine the optimal S/Co ratio to predict the confirmation results. RESULTS: We evaluated 129,346 serum samples screened by CMIA between January 2018 and December 2020. A total of 2468 samples were reactive; 2247 (91%) of them were confirmed to be positive and 221 (9%) were negative. Of the 2468 reactive specimens, 1747 (70.8%) had an S/Co ratio ≥10.4. When the S/Co ratios were ≥7.2 and ≥10.4, the specificity values were determined to be 95% and 100%, respectively. In a subgroup of 75 CMIA-positive patients, FTA-ABS was performed and 62 were positive. Among these FTA-ABS-positive patients, 24 had an S/Co ratio <10.4, and negative TPHA and RPR. CONCLUSIONS: We propose a potentially cost-effective reverse screening algorithm with a treponemal CMIA S/Co ratio ≥10.4, obviating the need for secondary treponemal testing in about 71% of the screening-reactive samples. This would substantially reduce the confirmatory testing volume and laboratory expenses. However, in high-risk group patients with CMIA positive results, S/Co ratio <10.4, and negative TPHA and RPR, FTA-ABS may be used for confirmation.


Assuntos
Sífilis , Anticorpos Antibacterianos , Testes de Hemaglutinação , Humanos , Imunoensaio , Técnicas Imunoenzimáticas , Sorodiagnóstico da Sífilis/métodos , Treponema pallidum
10.
Viral Immunol ; 35(2): 159-169, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35104162

RESUMO

Rabies vaccine preparations are quantitatively assayed for potency using the in-vivo challenge National Institute of Health (NIH), the main test that consumes a high number of animals, takes a long time, and has wide variability. The Rapid focus fluorescent inhibition (RFFIT) and the passive hemagglutination (PHA) tests, the two serologically based tests, were also used for such purpose. In this study, we aimed to evaluate and correlate the potency of the NIH, RFFIT, and PHA tests according to the World Health Organization (WHO) validity criteria, aiming to validate the use of RFFIT or PHA test as a substitute to the NIH test for determining the potency of commercially available Rabies vaccine preparations. The results showed that, the three tests can be successfully used; however, a higher correlation between RFFIT and NIH than PHA and NIH was recorded (Pearson correlation = 1). The potency of rabies vaccine preparations using NIH, RFFIT, and PHA were 3.73, 3.51, and 4.50, respectively. NIH is the main test for the determination of vaccine potency carried out by conducting 25 experiments and consuming about 5,000 mice compared to 1,200 mice used with RFFIT and 1,000 mice used with PHA test. Taken together, we concluded that (i) in some tested preparations, both RFFIT and PHA tests gave comparable results, and they can be used interchangeably; (ii) RFFIT could successfully replace NIH test, but not PHA; (iii) RFFIT and PHA tests are faster, more accurate, more economic, and more sensitive than NIH; nevertheless, PHA needs further investigations; and (iv) both RFFIT and NIH tests complement and reinforce each other as they provide a comprehensive picture of the product potency.


Assuntos
Vacina Antirrábica , Vírus da Raiva , Raiva , Animais , Anticorpos Antivirais , Testes de Hemaglutinação , Camundongos , Testes de Neutralização/métodos , Raiva/prevenção & controle , Potência de Vacina
11.
Comp Immunol Microbiol Infect Dis ; 80: 101736, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34906907

RESUMO

Blue eye disease (BED) in pigs is caused by Porcine orthorubulavirus (PRV) of the Paramyxoviridae family. It is an endemic disease in swine production in the central region of Mexico and causes nervous signs and high mortality in suckling pigs, pneumonia in growing pigs, orchitis in boars and mummification during gestation. PRV hemagglutinates most red blood cells (RBCs) of domestic species. For serological diagnosis, the hemagglutination inhibition test is used, and in this test, guinea pig, bovine and chicken RBCs have been commonly used. In this investigation, hemagglutination with PRV was evaluated using the RBCs of seven domestic species (chicken, bovine, horse, pig, dog, guinea pig and rabbit). In the hemagglutination test, the following parameters were evaluated: temperature (25 °C and 37 °C), bottoms of the wells (V and U), erythrocyte concentration (0.5%, 0.75%, and 1%), and reading time (15, 30, 45, 60 and 90 min). Significant differences (P < 0.001) were found in most of the evaluated treatments. The best hemagglutination results were obtained with chicken, bovine and horse RBCs. The hemagglutination titer is higher (2 dilutions) when using chicken RBCs than when using bovine or horse RBCs. If chicken RBCs are used in the inhibition of hemagglutination, the test will be more sensitive, while it is more specific when bovine or horse RBCs are used. The hemagglutination readings are imprecise when using RBCs from dogs, pigs, guinea pigs and rabbits. RBCs from these species should not be used for the diagnosis or investigation of PRV.


Assuntos
Testes de Inibição da Hemaglutinação , Testes de Hemaglutinação , Animais , Bovinos , Galinhas , Cães , Eritrócitos , Cobaias , Testes de Inibição da Hemaglutinação/veterinária , Testes de Hemaglutinação/veterinária , Cavalos , Masculino , México , Coelhos , Suínos
12.
Sci Rep ; 11(1): 24507, 2021 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-34969960

RESUMO

Diagnostic tests that detect antibodies (AB) against SARS-CoV-2 for evaluation of seroprevalence and guidance of health care measures are important tools for managing the COVID-19 pandemic. Current tests have certain limitations with regard to turnaround time, costs and availability, particularly in point-of-care (POC) settings. We established a hemagglutination-based AB test that is based on bi-specific proteins which contain a dromedary-derived antibody (nanobody) binding red blood cells (RBD) and a SARS-CoV-2-derived antigen, such as the receptor-binding domain of the Spike protein (Spike-RBD). While the nanobody mediates swift binding to RBC, the antigen moiety directs instantaneous, visually apparent hemagglutination in the presence of SARS-CoV-2-specific AB generated in COVID-19 patients or vaccinated individuals. Method comparison studies with assays cleared by emergency use authorization demonstrate high specificity and sensitivity. To further increase objectivity of test interpretation, we developed an image analysis tool based on digital image acquisition (via a cell phone) and a machine learning algorithm based on defined sample-training and -validation datasets. Preliminary data, including a small clinical study, provides proof of principle for test performance in a POC setting. Together, the data support the interpretation that this AB test format, which we refer to as 'NanoSpot.ai', is suitable for POC testing, can be manufactured at very low costs and, based on its generic mode of action, can likely be adapted to a variety of other pathogens.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , Testes Diagnósticos de Rotina/métodos , Testes de Hemaglutinação/métodos , Testes Imediatos , Glicoproteína da Espícula de Coronavírus/imunologia , Humanos , Estudo de Prova de Conceito
13.
Am J Trop Med Hyg ; 106(1): 54-59, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34724627

RESUMO

Melioidosis is an infection caused by the bacterium Burkholderia pseudomallei. The most common presentation is bacteremia occurring in 38-73% of all patients, and the mortality rate ranges from 9% to 42%. Although there is abundant data representing risk factors for infection and patient outcomes, there is limited information regarding laboratory investigations associated with bacteremia and mortality. We assessed a range of baseline and diagnostic investigations and their association with patient outcomes in a retrospective cohort study in Townsville, Australia. 124 patients' medical and laboratory records were reviewed between January 1, 1997 and December 31, 2020. Twenty-seven patients died and 87 patients were bacteremic. The presence of lymphopenia (< 1.5 × 109 cells/L) was the highest risk for bacteremia (relative risk [RR] 2.2; 95% CI: 1.3-3.7, P < 0.001). Factors associated with mortality included lymphopenia, (RR: 1.4; 95% CI: 1.2-1.6, P = 0.004); uremia (RR: 1.7; 95% CI: 1.1-2.5, P = 0.03); and an elevated international normalized ratio (RR: 1.5; 95% CI: 1.2-2.0, P = 0.006). Median incubation to positive blood culture result was 28 hours with 15/82 (18%) positive in ≤ 24 hours. For serological testing during admission only 53/121 (44%) were indirect hemagglutination assay positive, 67/120 (56%) enzyme immunoassay IgG positive, and 23/89 (26%) IgM positive. Simple baseline investigations at time of presentation may be used to stratify patients at high risk for both bacteremia and mortality. This information can be used as a decision aid for early intensive management.


Assuntos
Melioidose , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Bacteriemia/patologia , Burkholderia pseudomallei/isolamento & purificação , Feminino , Testes de Hemaglutinação , Hospitalização , Humanos , Masculino , Melioidose/patologia , Pessoa de Meia-Idade , Mortalidade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
14.
J Clin Microbiol ; 59(12): e0118621, 2021 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-34469185

RESUMO

Serologic point-of-care tests to detect antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are an important tool in the COVID-19 pandemic. The majority of current point-of-care antibody tests developed for SARS-CoV-2 rely on lateral flow assays, but these do not offer quantitative information. To address this, we developed a novel antibody test leveraging hemagglutination, employing a dry card format currently used for typing ABO blood groups. Two hundred COVID-19 patient and 200 control plasma samples were reconstituted with O-negative red blood cells (RBCs) to form whole blood and added to dried viral-antibody fusion protein, followed by a stirring step and a tilting step, 3-min incubation, and a second tilting step. The sensitivities of the hemagglutination test, Euroimmun IgG enzyme-linked immunosorbent assay (ELISA), and receptor binding domain (RBD)-based CoronaChek lateral flow assay were 87.0%, 86.5%, and 84.5%, respectively, using samples obtained from recovered COVID-19 individuals. Testing prepandemic samples, the hemagglutination test had a specificity of 95.5%, compared to 97.3% and 98.9% for the ELISA and CoronaChek, respectively. A distribution of agglutination strengths was observed in COVID-19 convalescent-phase plasma samples, with the highest agglutination score (4) exhibiting significantly higher neutralizing antibody titers than weak positives (2) (P < 0.0001). Strong agglutinations were observed within 1 min of testing, and this shorter assay time also increased specificity to 98.5%. In conclusion, we developed a novel rapid, point-of-care RBC agglutination test for the detection of SARS-CoV-2 antibodies that can yield semiquantitative information on neutralizing antibody titer in patients. The 5-min test may find use in determination of serostatus prior to vaccination, postvaccination surveillance, and travel screening.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Hemaglutinação , Testes de Hemaglutinação , Humanos , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
15.
Turkiye Parazitol Derg ; 45(3): 207-210, 2021 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-34346877

RESUMO

Objective: This study aimed to retrospectively examine the indirect haemagglutination (IHA) test results of patients suspected of cystic echinococcosis (CE) and admitted to Bursa Uludag University Health Practice and Research Center Hospital. Methods: Serum samples in the serology laboratory of our hospital were evaluated using the commercial Cellognost® echinococcosis IHA (Siemens Healthcare Diagnostics, Marburg, Germany) test based on the manufacturer's recommendations. In the IHA test, ≥1:64 serum titres were accepted as positive. Results: Seropositivity was determined in 213 (19.9%) of 1.072 patients suspected of having CE by the IHA method. Of the patients with seropositivity, 120 (56.3%) were female and 93 (43.7%) were male. The highest positivity rate in both sexes was found in patients aged 20-29 years (22.5% in women; 14.1% in men). Conclusion: The results indicate that CE maintains its importance as a public health problem in Bursa as in Turkey.


Assuntos
Equinococose , Laboratórios , Anticorpos Anti-Helmínticos , Equinococose/diagnóstico , Equinococose/epidemiologia , Ensaio de Imunoadsorção Enzimática , Feminino , Testes de Hemaglutinação , Humanos , Masculino , Estudos Retrospectivos , Turquia/epidemiologia
17.
Zhongguo Xue Xi Chong Bing Fang Zhi Za Zhi ; 33(2): 138-147, 2021 Apr 20.
Artigo em Chinês | MEDLINE | ID: mdl-34008360

RESUMO

OBJECTIVE: To evaluate the conversion of serum antibodies against Schistosoma japonicum in humans and livestock detected by immunological tests following treatment with praziquantel. METHODS: The studies pertaining to serological tests of schistosomiasis japonica published from 1991 to 2020 were retrieved in electronic databases, including Chinese National Knowledge Infrastructure, WanFang Data, PubMed and ScienceDirect. Data were extracted from included studies. The publication bias was assessed with funnel plots using the software RevMan version 5.3, and the conversion of antibodies against S. japonicum was evaluated through meta-analysis. RESULTS: A total of 40 publications were included in the final meta-analysis, consisting of 33 Chinese publications and 7 English publications, and all immunological tests were performed with indirect hemagglutination test (IHA) and enzyme-linked immunosorbent assay (ELISA). Pooled analysis showed that the negative rates of serum anti-S. japonicum antibody were 45.36% [95% confidential interval (CI): (43.96%, 46.76%)] and 20.83% [95% CI: (19.69%, 21.97%)] detected by ELISA and IHA within 6 months post praziquantel treatment, 62.95% [95% CI: (61.59%, 64.31%)] and 55.61% [95% CI: (54.21%, 57.01%)] within 6 to 12 months after treatment and 85.92% [95% CI: (84.94%, 86.90%)] and 86.90% [95% CI: (85.95%, 87.85%)] over 12 months after treatment, respectively. CONCLUSIONS: The negative rate of the serum anti-S. japonicum antibody by IHA and ELISA increased with the time of post-treatment with praziquantel. The overall negative rates of anti-S. japonicum antibody detected by IHA and ELISA are low within 12 months post praziquantel treatment. However, a high negative rate of anti-S. japonicum antibody is detected if there is no new contact with infested water after 12 months of praziquantel treatment.


Assuntos
Schistosoma japonicum , Esquistossomose Japônica , Animais , Ensaio de Imunoadsorção Enzimática , Testes de Hemaglutinação , Humanos , Praziquantel/uso terapêutico , Esquistossomose Japônica/tratamento farmacológico
19.
Viruses ; 13(4)2021 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-33805157

RESUMO

We describe for the first time the genetic and antigenic characterization of 18 avian avulavirus type-6 viruses (AAvV-6) that were isolated from wild waterfowl in the Americas over the span of 12 years. Only one of the AAvV-6 viruses isolated failed to hemagglutinate chicken red blood cells. We were able to obtain full genome sequences of 16 and 2 fusion gene sequences from the remaining 2 isolates. This is more than double the number of full genome sequences available at the NCBI database. These AAvV-6 viruses phylogenetically grouped into the 2 existing AAvV-6 genotype subgroups indicating the existence of an intercontinental epidemiological link with other AAvV-6 viruses isolated from migratory waterfowl from different Eurasian countries. Antigenic maps made using HI assay data for these isolates showed that the two genetic groups were also antigenically distinct. An isolate representing each genotype was inoculated in specific pathogen free (SPF) chickens, however, no clinical symptoms were observed. A duplex fusion gene based real-time assay for the detection and genotyping of AAvV-6 to genotype 1 and 2 was developed. Using the developed assay, the viral shedding pattern in the infected chickens was examined. The chickens infected with both genotypes were able to shed the virus orally for about a week, however, no significant cloacal shedding was detected in chickens of both groups. Chickens in both groups developed detectable levels of anti-hemagglutinin antibodies 7 days after infection.


Assuntos
Animais Selvagens/virologia , Antígenos Virais/imunologia , Infecções por Avulavirus/veterinária , Avulavirus/genética , Doenças das Aves/epidemiologia , Doenças das Aves/virologia , Genótipo , Migração Animal , Animais , Avulavirus/classificação , Avulavirus/imunologia , Avulavirus/isolamento & purificação , Doenças das Aves/transmissão , Canadá/epidemiologia , Galinhas/virologia , Cloaca/virologia , Genoma Viral , Testes de Hemaglutinação , Filogenia , Doenças das Aves Domésticas/virologia , Organismos Livres de Patógenos Específicos , Eliminação de Partículas Virais
20.
Nat Commun ; 12(1): 1951, 2021 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-33782398

RESUMO

Serological detection of antibodies to SARS-CoV-2 is essential for establishing rates of seroconversion in populations, and for seeking evidence for a level of antibody that may be protective against COVID-19 disease. Several high-performance commercial tests have been described, but these require centralised laboratory facilities that are comparatively expensive, and therefore not available universally. Red cell agglutination tests do not require special equipment, are read by eye, have short development times, low cost and can be applied at the Point of Care. Here we describe a quantitative Haemagglutination test (HAT) for the detection of antibodies to the receptor binding domain of the SARS-CoV-2 spike protein. The HAT has a sensitivity of 90% and specificity of 99% for detection of antibodies after a PCR diagnosed infection. We will supply aliquots of the test reagent sufficient for ten thousand test wells free of charge to qualified research groups anywhere in the world.


Assuntos
Anticorpos Antivirais/análise , Teste para COVID-19/métodos , COVID-19/diagnóstico , Testes de Hemaglutinação/métodos , SARS-CoV-2/isolamento & purificação , Glicoproteína da Espícula de Coronavírus/imunologia , Testes de Aglutinação/métodos , Anticorpos Monoclonais/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , COVID-19/sangue , COVID-19/imunologia , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Soroconversão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA