Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.847
Filtrar
1.
BMC Ophthalmol ; 24(1): 183, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649861

RESUMO

AIM: To evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL) and targeted refraction. METHODS: This retrospective study comprised age-matched eyes that underwent implantation of the EDOF IOL. Eyes were categorized based on AL into groups: control group with AL < 26 mm; high myopia group with AL ≥ 26 mm. Each group was then subdivided based on postoperative spherical equivalent (SE). Follow-up at three months included assessment of uncorrected visual acuity at different distances, contrast sensitivity (CS), refractive outcomes, and spectacle independence. RESULTS: Overall, this study included 100 eyes from 100 patients, comprising 50 males (50.00%) and 50 females (50.00%), with 20 eyes in each group. In the control group, the uncorrected distance visual acuity (UDVA) at 5 and 3 m (m) in the - 1.50 to -0.75 group was inferior to that of the - 0.75 to 0.00 group (P = 0.004). Conversely, the uncorrected near visual acuity (UNVA) at 33 cm in the - 1.50 to -0.75 group was superior to that of the - 0.75 to 0.00 group (P = 0.005). Within the high myopia group, the UDVA at 5 and 3 m in the - 2.25 to -1.50 group was worse than in the - 0.75 to 0.00 group (P = 0.009 and 0.008, respectively). However, the UNVA at 33 cm in the - 2.25 to -1.50 group was better than in the - 0.75 to 0.00 group (P = 0.020). No significant differences were observed among the groups for corrected distance visual acuity (CDVA) (P > 0.05). Additionally, in the high myopia group, the CS of the - 2.25 to -1.50 group was lower compared to that of the - 0.75 to 0.00 group (P = 0.017). Among high myopia patients, 90.00% with refraction ranging from - 1.50 to -0.75 reported achieving overall spectacle independence. CONCLUSIONS: Implantation of extended depth of focus intraocular lenses (IOLs) yields satisfactory visual and refractive outcomes in eyes with axial myopia. Among high myopia patients, a refraction ranging from - 1.50 to -0.75 diopters achieves superior visual quality compared to other postoperative myopic diopters.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Miopia , Refração Ocular , Acuidade Visual , Humanos , Feminino , Masculino , Estudos Retrospectivos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Miopia/fisiopatologia , Miopia/cirurgia , Idoso , Desenho de Prótese , Adulto , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Pseudofacia/fisiopatologia , Comprimento Axial do Olho , Percepção de Profundidade/fisiologia , Seguimentos
2.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651698

RESUMO

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Esclera , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Esclera/cirurgia , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia , Retalhos Cirúrgicos , Técnicas de Sutura , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia
3.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658894

RESUMO

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Assuntos
Terapia a Laser , Lentes Intraoculares Multifocais , Facoemulsificação , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Terapia a Laser/métodos , Idoso , Refração Ocular/fisiologia , Implante de Lente Intraocular/métodos , Pseudofacia/fisiopatologia , Resultado do Tratamento , Desenho de Prótese , Extração de Catarata/métodos , Seguimentos
4.
Eye (Lond) ; 38(Suppl 1): 9-14, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580741

RESUMO

BACKGROUND/OBJECTIVE: To evaluate the visual performance of a purely refractive extended depth of focus (EDF) intraocular lens (IOL). SUBJECTS/METHODS: A prospective, multi-center, randomized, subject/evaluator-masked study. Subjects were bilaterally implanted with the EDF test (Model ZEN00V, N = 60) or an enhanced monofocal control (Model ICB00, N = 57) IOL. Monocular corrected distance (CDVA), intermediate (DCIVA), near acuities (DCNVA) and patient reported visual symptoms were evaluated at the 6-month visit. Monocular mesopic contrast sensitivity (CS) and depth of focus (DOF) testing were assessed at 3 months. RESULTS: CDVA (Mean ± SD) was -0.06 ± 0.08 for test and -0.05 ± 0.08 logMAR for control groups. DCIVA was 0.13 ± 0.08 for test and 0.18 ± 0.14 logMAR for control groups (p = 0.0127). DCNVA was 0.37 ± 0.10 for test and 0.43 ± 0.16 logMAR for control groups (p = 0.0137). Test lens was statistically superior for intermediate and near. Overall, 91.7% (halos), 95.0% (starbursts) and 95.0% (glare) of test lens patients reported that they did not experience, were not bothered, or were slightly bothered by specific visual symptoms, compared to 98.2%, 100% and 96.5% in the control group. The DOF range over which monocular visual acuity was 0.20 logMAR or better was -1.6 D for the test lens. Mesopic CS was comparable between both groups, falling within 0.11 log units for all measured cycles per degree with and without glare. CONCLUSION: The EDF IOL demonstrated extended range of vision and statistically superior intermediate and near performance compared to the monofocal IOL. Distance visual acuity, contrast sensitivity and dysphotopsia profile were similar to the monofocal IOL.


Assuntos
Sensibilidades de Contraste , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Pseudofacia , Acuidade Visual , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Sensibilidades de Contraste/fisiologia , Idoso , Pessoa de Meia-Idade , Percepção de Profundidade/fisiologia , Pseudofacia/fisiopatologia , Desenho de Prótese , Refração Ocular/fisiologia , Facoemulsificação , Método Duplo-Cego , Satisfação do Paciente
5.
Eye (Lond) ; 38(Suppl 1): 15-20, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580742

RESUMO

PURPOSE: To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics. METHODS: Preclinical evaluation included computer simulations of visual acuity (sVA) and dysphotopsia profile of different IOL designs (refractive EDF, diffractive EDF, multifocal, standard, and enhanced monofocals) using an appropriate eye model with and without ±0.50 D defocus and/or +0.75 D of astigmatism. Patients bilaterally implanted with a refractive EDF (Model ZEN00V) or an enhanced monofocal (Model ICB00) IOL from a prospective, randomized study were included. At the 6-month postoperative visit, uncorrected and corrected distance vision (UDVA and CDVA), visual symptoms, satisfaction and dependency on glasses were evaluated in a subgroup of patients with absolute residual refractive error of >0.25 D in one or both eyes. RESULTS: In the presence of defocus and astigmatism, sVA was comparable for all except the multifocal IOL design. The refractive EDF was more tolerant to myopic outcomes and maintained a monofocal-like dysphotopsia profile with defocus. Binocular logMAR UDVA was -0.03 ± 0.08 for ZEN00V and -0.02 ± 0.11 for ICB00. 100% ZEN00V and 97% ICB00 patients did not need glasses and were satisfied with their distance vision. Monocular CDVA, contrast sensitivity and visual symptoms were also similar between both groups. CONCLUSIONS: The clinical outcomes of the refractive EDF IOL demonstrated high quality distance vision and dysphotopsia comparable to a monofocal IOL, even in the presence of refractive error, thus matching the design expectations of the EDF IOL.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Percepção de Profundidade/fisiologia , Pseudofacia/fisiopatologia , Erros de Refração/fisiopatologia , Facoemulsificação , Satisfação do Paciente , Simulação por Computador , Refração Ocular/fisiologia , Astigmatismo/fisiopatologia , Visão Binocular/fisiologia
6.
BMC Ophthalmol ; 24(1): 198, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671381

RESUMO

BACKGROUND: Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). METHODS: This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. RESULTS: There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). CONCLUSIONS: Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. TRIAL REGISTRATION: This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).


Assuntos
Lentes Intraoculares , Acuidade Visual , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Facoemulsificação , Refração Ocular/fisiologia , Implante de Lente Intraocular , Desenho de Prótese , Período Pós-Operatório , Pseudofacia/fisiopatologia , Óptica e Fotônica
7.
BMC Ophthalmol ; 24(1): 136, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38532398

RESUMO

PURPOSE: To determine the distribution of subfoveal choroidal thickness (SFCT) and its associated demographic, ocular, and systemic factors in an elderly population. METHODS: This report is part of the Tehran Geriatric Eye Study (TGES); a population-based cross-sectional study that was conducted on the urban elderly population of Tehran, aged 60 years and above using multi-stage stratified random cluster sampling. Choroidal imaging was performed using Spectralis SD-OCT with enhanced depth imaging mode. RESULTS: The average SFCT was 265.3 ± 25.9 µm (95% CI: 262.8-267.7) in the whole sample. According to the multiple generalized estimating equation (GEE) model, pseudophakia had a statistically significant direct relationship with SFCT (coefficient = 5.69), and history of cerebrovascular accident (CVA) was significantly inversely related to SFCT (coefficient=-4.77). Moreover, there was a significant interaction between age and sex in the average SFCT so that with increasing age, the SFCT increased in men and decreased in women. CONCLUSION: The normal values of SFCT in the present study can be used as a reference database for clinical and research purposes. Age-sex interaction, pseudophakia, and history of CVA were significantly associated with SFCT in the elderly population. It is recommended that these factors be taken into account when interpreting SFCT data.


Assuntos
Corioide , Pseudofacia , Masculino , Humanos , Idoso , Feminino , Estudos Transversais , Irã (Geográfico) , Tomografia de Coerência Óptica/métodos
8.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466765

RESUMO

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/métodos , Miopia/cirurgia , Acomodação Ocular , Câmara Anterior/diagnóstico por imagem , Pseudofacia/cirurgia , Tomografia de Coerência Óptica , Biometria
9.
J Fr Ophtalmol ; 47(4): 104105, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428321

RESUMO

PURPOSE: To compare the visual outcomes in both eyes of patients who undergo phacoemulsification and trifocal intraocular lens (IOL) implantation and have asteroid hyalosis (AH) or synchysis scintillans (SS) in only one eye. METHODS: A retrospective comparative case series was performed. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction after implantation of the same model of trifocal IOL in both eyes (PhysIOL FineVision Pod-F and Micro-F and Rayner RayOne Trifocal). RESULTS: A total of 164 eyes of 82 patients (41 females, 50%) met the inclusion criteria. There were no statistically significant differences in sphere, cylinder, spherical equivalent, UDVA, UIVA, or UNVA between the groups. Postoperative CDVA was slightly better in the control group (logMAR 0.03) than in the AH/SS group (logMAR 0.04) (P: 0.014). There were no statistically significant differences in predictability, safety index, or efficacy index between the groups. Overall subjective satisfaction was good (98.2%). CONCLUSIONS: Visual outcomes and satisfaction are good after implantation of trifocal IOLs in eyes with AH or SS. Therefore, trifocal IOLs should not be ruled out in these patients when no other vitreoretinal disorder is present.


Assuntos
Lentes Intraoculares , Doenças Orbitárias , Facoemulsificação , Feminino , Humanos , Facoemulsificação/efeitos adversos , Implante de Lente Intraocular/efeitos adversos , Estudos Retrospectivos , Satisfação do Paciente , Lentes Intraoculares/efeitos adversos , Refração Ocular , Transtornos da Visão , Desenho de Prótese , Pseudofacia/complicações , Pseudofacia/cirurgia
10.
BMC Ophthalmol ; 24(1): 86, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409015

RESUMO

BACKGROUND: To evaluate visual performance after implantation of the TFNT (Acrysof Panoptix, Alcon, Fort Worth, Texas, USA) and CNWT (Clareon Panoptix, Alcon, Fort Worth, Texas, USA) intraocular lens (IOL), and compare the lens shape observed by scanning electron microscope (SEM). METHODS: Eighteen patients (18 eyes) received implantation of the CNWT and Twenty patients (20 eyes) received implantation of the TFNT. Exclusion criteria were previous ocular surgeries, ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 1 months including manifest refraction; evaluation of refractive error, distance-corrected visual acuity (DCVA) at 5 m, 1 m, 70 cm, 50 cm, 40 cm, and 30 cm, slit-lamp examination; defocus curve testing; contrast sensitivity (CS) was performed. The lens shape of the TFNT and the CNWT was examined under SEM. RESULTS: Mean spherical equivalent was 0.11 ± 0.41 D (CNWT group) and 0.12 ± 0.34 D (TFNT group) 1 month postoperation. DCVA and defocus curve showed no significant difference between the two groups. CS was significantly higher in CNWT group than TFNT group at spatial frequencies of 6 cycles per degree (cpd). Observation of the IOL with a scanning electron microscope (SEM) revealed that CNWT group had improved diffraction structure and edge processing accuracy compared to TFNT group. CONCLUSION: There was no significant difference between the two groups in the defocus curve and visual acuity at all distances. CS was better in the CNWT group than in the TFNT group. IOL surface features may affect CS.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Microscopia Eletrônica de Varredura , Implante de Lente Intraocular , Pseudofacia/cirurgia , Visão Binocular , Refração Ocular , Desenho de Prótese
11.
BMC Ophthalmol ; 24(1): 72, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365667

RESUMO

PURPOSE: To compare the rotational stability of a monofocal and a diffractive multifocal toric intraocular lens(IOLs) with identical design and material. METHODS: This prospective study enrolled patients who underwent plate-haptic toric IOL (AT TORBI 709 M and AT LISA 909 M) implantation. Propensity score matching (PSM) was performed to balance baseline factors. Follow-up examinations were conducted at 1 h, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was used to investigate the changes in IOL rotation over time. A 2-week timeframe was utilized to assess differences in IOL rotation between the two groups. RESULT: After PSM, a total of 126 eyes were selected from each group for further analysis. Postoperatively, the time course of IOL rotation change in the two groups remained consistent, with the greatest rotation occurring between 1 h and 1 day postoperatively. At the 2-week postoperative mark, the monofocal toric IOL exhibited a higher degree of rotation compared to the multifocal toric IOL (5.40 ± 7.77° vs. 3.53 ± 3.54°, P = 0.015). In lens thickness(LT) ≥ 4.5 mm and white-to-white distance(WTW) ≥ 11.6 mm subgroups, the monofocal toric IOL rotated greater than the multifocal toric IOL (P = 0.026 and P = 0.011, respectively). CONCLUSION: The diffractive multifocal toric IOL exhibits superior rotational stability compared to the monofocal toric IOL, especially in subgroups LT ≥ 4.5 mm and WTW ≥ 11.6 mm. Moreover, the time course of IOL rotation change is consistent for both, with the maximum rotation occurring between 1 h and 1 day postoperatively.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Pseudofacia/cirurgia , Acuidade Visual , Pontuação de Propensão , Astigmatismo/cirurgia , Refração Ocular
12.
Int Ophthalmol ; 44(1): 43, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334834

RESUMO

PURPOSE: To examine the ophthalmic data from a large database of people attending a general medical survey institute, and to investigate ophthalmic findings of the eye and its adnexa, including differences in age and sex. METHODS: Retrospective analysis including medical data of all consecutive individuals whose ophthalmic data and the prevalences of ocular pathologies were extracted from a very large database of subjects examined at a single general medical survey institute. RESULTS: Data were derived from 184,589 visits of 3676 patients (mean age 52 years, 68% males). The prevalence of the following eye pathologies were extracted. Eyelids: blepharitis (n = 4885, 13.3%), dermatochalasis (n = 4666, 12.7%), ptosis (n = 677, 1.8%), ectropion (n = 73, 0.2%), and xanthelasma (n = 160, 0.4%). Anterior segment: pinguecula (n = 3368, 9.2%), pterygium (n = 852, 2.3%), and cataract or pseudophakia (n = 9381, 27.1%). Cataract type (percentage of all phakic patients): nuclear sclerosis (n = 8908, 24.2%), posterior subcapsular (n = 846, 2.3%), and capsular anterior (n = 781, 2.1%). Pseudophakia was recorded for 697 patients (4.6%), and posterior subcapsular opacification for 229 (0.6%) patients. Optic nerve head (ONH): peripapillary atrophy (n = 4947, 13.5%), tilted disc (n = 3344, 9.1%), temporal slope (n = 410, 1.1%), ONH notch (n = 61, 0.2%), myelinated nerve fiber layer (n = 94, 0.3%), ONH drusen (n = 37, 0.1%), optic pit (n = 3, 0.0%), and ON coloboma (n = 4, 0.0%). Most pathologies were more common in males except for ONH, and most pathologies demonstrated a higher prevalence with increasing age. CONCLUSIONS: Normal ophthalmic data and the prevalences of ocular pathologies were extracted from a very large database of subjects seen at a single medical survey institute.


Assuntos
Catarata , Pseudofacia , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Prevalência , Estudos Retrospectivos , Nervo Óptico
13.
Retina ; 44(5): 791-798, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38236936

RESUMO

PURPOSE: To compare SF 6 relative with C 2 F 6 in the anatomical and functional outcomes following pars plana vitrectomy for uncomplicated primary pseudophakic rhegmatogenous retinal detachment with inferior causative breaks. METHODS: This is a retrospective, comparative study on eyes with pseudophakic rhegmatogenous retinal detachment with inferior causative breaks that had small-gauge pars plana vitrectomy repair using SF 6 and C 2 F 6 tamponade between 2011 and 2020 at a tertiary centre in the United Kingdom. Primary outcome was single surgery anatomical success, and the secondary outcome was best-corrected visual acuity. Propensity score matching, using preoperative findings as covariates to account for relevant confounders, was performed. RESULTS: From 162 pseudophakic rhegmatogenous retinal detachment eyes with inferior causative breaks, the median (interquartile range) follow-up was 82 (52-182) days. The single surgery anatomical success was 156 (96.3%) overall: 47 of 47 (100.0%) and 109 of 115 (94.8%) in the SF 6 and C 2 F 6 groups, respectively ( P = 0.182). Relative to the SF 6 group, the C 2 F 6 group had a higher mean number of tears (SF 6 : 3.1[2.0], C 2 F 6 : 4.5[2.7], P = 0.002) and greater retinal detachment extent (SF 6 : 5.3[2.9], C 2 F 6 : 6.2[2.6] clock hours, P = 0.025). Following propensity score matching analysis, 80 eyes were matched with 40 in each group to homogenize preoperative factors. No significant difference was found in single surgery anatomical success and best-corrected visual acuity between the groups following propensity score matching. CONCLUSION: Primary pars plana vitrectomy with gas tamponade leads to a high single surgery anatomical success rate in uncomplicated pseudophakic rhegmatogenous retinal detachment with inferior causative breaks with no additional benefit associated with long-acting tamponade when comparing C 2 F 6 with SF 6 .


Assuntos
Tamponamento Interno , Fluorocarbonos , Pseudofacia , Descolamento Retiniano , Hexafluoreto de Enxofre , Acuidade Visual , Vitrectomia , Humanos , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Vitrectomia/métodos , Estudos Retrospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia , Pseudofacia/complicações , Tamponamento Interno/métodos , Idoso , Hexafluoreto de Enxofre/administração & dosagem , Pessoa de Meia-Idade , Fluorocarbonos/administração & dosagem , Perfurações Retinianas/cirurgia , Perfurações Retinianas/etiologia , Perfurações Retinianas/diagnóstico , Seguimentos , Resultado do Tratamento
14.
J Cataract Refract Surg ; 50(5): 492-497, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237070

RESUMO

PURPOSE: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. SETTING: National Hospital Organization, Tokyo Medical Center, Japan. DESIGN: Retrospective case series. METHODS: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. RESULTS: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). CONCLUSIONS: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.


Assuntos
Comprimento Axial do Olho , Biometria , Lentes Intraoculares , Óptica e Fotônica , Facoemulsificação , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Estudos Retrospectivos , Biometria/métodos , Masculino , Feminino , Tomografia de Coerência Óptica/métodos , Refração Ocular/fisiologia , Implante de Lente Intraocular , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia
15.
BMC Ophthalmol ; 24(1): 40, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273262

RESUMO

BACKGROUND: This study aimed to compare the corneal high-order aberrations and surgically induced astigmatism between the clear corneal incision and limbus tunnel incision for posterior chamber implantable collamer lens (ICL/TICL) implantation. METHODS: A total of 127 eyes from 73 myopic patients underwent ICL V4c implantation, with 70 eyes receiving clear corneal incisions and 57 eyes receiving limbus tunnel incisions. The anterior and back corneal surfaces were measured and the Root Mean Square of all activated aberrations (TRMS) was calculated, including higher-order aberration (HOA RMS), spherical aberration Z40, coma coefficients (Coma RMS) Z3-1 Z31, and surgically induced astigmatism (SIA). The measurements were taken preoperatively and postoperatively at 1 day, 1 week, and 1, 3, and 6 months. In this study, the corneal higher-order aberration was estimated as the Zernike coefficient calculated up to 5th order. The measurements were taken at a maximum diameter of 6.5 mm using Pentacam. RESULTS: One week after the operation, the corneal back Z31 of the clear corneal incision group was 0.06 ± 0.06, while the limbus tunnel incision group showed a measurement of 0.05 ± 0.06 (p = 0.031). The corneal back Z40 of the clear corneal incision group was -0.02 ± 0.25, compared to -0.04 ± 0.21 in the limbus tunnel incision group (p = 0.01). One month after the operation, the corneal back SIA of the clear corneal incision group was 0.11 ± 0.11, compared to 0.08 ± 0.11of the limbus tunnel incision group (p = 0.013), the corneal total SIA of the clear corneal incision group was 0.33 ± 0.30, compared to 0.15 ± 0.16 in the limbus tunnel incision group (p = 0.004); the clear corneal incision group exhibited higher levels of back astigmatism and total SIA than the limbus tunnel incision in the post-operation one month period. During the 6- month post-operative follow-up period, no significant difference in Z31, Z40, and other HOA RMS data was observed between the two groups. The total SIA of the corneal incision group and the limbus tunnel incision group were 0.24 ± 0.14 and 0.33 ± 0.32, respectively (p = 0.393), showing no significant difference between the two groups 6 months after the operation. CONCLUSION: Our data showed no significant difference in the high-order aberration and SIA between clear corneal incision and limbus tunnel incision up to 6 months after ICL-V4c implantation.


Assuntos
Astigmatismo , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Implante de Lente Intraocular , Coma/cirurgia , Córnea/cirurgia , Pseudofacia/cirurgia
16.
Eye (Lond) ; 38(2): 321-327, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37524833

RESUMO

OBJECTIVES: To assess intra-individually visual acuity (VA) and subjective outcome after mix-and-match implantation of a monofocal EDOF IOL and a diffractive trifocal IOL. METHODS: The monofocal EDOF Isopure IOL was implanted in the dominant eye and the trifocal FineVision HP IOL in the non-dominant eye. Postoperative evaluation included VA at various distances, contrast acuity, monocular defocus curves, decentration and tilt, wavefront aberrometry, VF-7 questionnaire and a halo and glare simulator. RESULTS: 50 eyes of 25 subjects were enroled. The trifocal IOL performed better at monocular DCNVA (p < 0.01) and at defocus levels of -1.5D to -4.0D (p < 0.01), the monofocal EDOF IOL was better at -0.5D (p = 0.013). No differences in monocular BCDVA, DCIVA, contrast acuity, decentration or tilt were observed (p > 0.05). Wavefront analysis revealed lower HOAs in the trifocal group at 5 mm (p < 0.01) and no difference (p = 0.107) at 3 mm pupil aperture. The monofocal EDOF IOL displayed increased negative SA at 5 mm (p < 0.01) and 3 mm (p < 0.01) pupil diameter. Low values of optical phenomena and satisfying results of the VF-7 questionnaire were obtained. CONCLUSION: Excellent visual performance and low rates of optical phenomena were achieved after mix-and-match implantation of the monofocal EDOF Isopure IOL and the trifocal FineVision HP IOL. Trifocal IOL implantation in the non-dominant eye may decrease optical disturbing phenomena. Similar results were observed for monocular distance, intermediate and contrast VA. The trifocal IOL provided better monocular near VA. Decentration and tilt and HOAs were low.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Visão Binocular , Estudos Prospectivos , Desenho de Prótese , Satisfação do Paciente , Refração Ocular , Pseudofacia
17.
J Cataract Refract Surg ; 50(2): 153-159, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37847119

RESUMO

PURPOSE: To compare visual performance and photic visual disturbances of patients implanted with 2 different extended depth-of-focus (EDOF) intraocular lenses (IOLs) using mini-monovision. SETTING: Ambulatory surgical center at the University of São Paulo in Ribeirão Preto, Brazil. DESIGN: Prospective, examiner-masked, randomized clinical trial. METHODS: Patients were assigned to either a bilateral Symfony (SYM) or Vivity (VIV) IOL group, with 1 eye targeted for myopia (-0.75 diopter [D]). Defocus curve, contrast sensitivity (Pelli-Robson), Patient-Reported Spectacle Independence Questionnaire, and Quality of Vision questionnaire were recorded at 3 months postoperatively. RESULTS: A total of 126 patients finished the follow-up: group SYM: n = 60 and group VIV: n = 66. Regarding near visual acuity, 80% of patients in the SYM group and 84% of patients in the VIV group achieved J2 or better on the near-planned eye ( P = .3840). No significant differences were found between groups for distance visual acuity, defocus profiles, PRISC, contrast sensitivity, or reading speed ( P > .05). Notably, significant between-group differences were observed for bothersome visual disturbances ( P = .0235), with 45% of patients in the SYM group with a score of 0 for bothersome disturbances compared with 66% in the VIV group. CONCLUSIONS: Mini-monovision using these EDOF IOLs was well-tolerated in the patient cohort. No significant differences were found for visual performance tests between the VIV and SYM groups. However, the data suggest that Vivity IOL is associated with a lower probability of bothersome visual disturbances compared with Symfony IOL.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Visão Monocular , Estudos Prospectivos , Desenho de Prótese , Satisfação do Paciente , Refração Ocular , Pseudofacia
18.
J Cataract Refract Surg ; 50(2): 167-173, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37847127

RESUMO

PURPOSE: To compare the postoperative visual acuity curves following 3 pseudophakic presbyopic correction techniques. SETTING: Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, Greece. DESIGN: Prospective, randomized, comparative trial. METHODS: For this study, patients with stage 2 Lens Opacities Classification System III cataract were divided into 3 study groups: (1) premium monovision group, including patients who received the Panoptix intraocular lens (IOL) in the recessive eye and Vivity IOL in the dominant one; (2) bilateral trifocal group, including those who received bilaterally the Panoptix IOL; and (3) bilateral xEDOF group, including patients who received bilaterally the Vivity IOL. Postoperative bilateral uncorrected distance visual acuity was measured at 25.5, 28, 33, 40, 50, 66, 100, 200, and 300 cm distances. Spline curve fitting was attempted, and areas of the curves (AOCs) and curvature k were calculated. All patients responded to the National Eye Institute Visual Functioning Questionnaire-25 (NEI-VFQ-25). RESULTS: 90 patients were equally divided into the 3 groups. Premium monovision and bilateral trifocal implantations delivered similar visual acuity (all AOC P > .05); however, the trifocal patients suffered from drops in vision acuity in certain distance ranges as expressed by negative curvature values. Bilateral xEDOF patients demonstrated worse near vision acuity ( P < .05). Premium monovision patients reported better scores in NEI-VFQ 25 ( P = .03) and in the near activities ( P = .02) and distant activities ( P = .04) subscales. CONCLUSIONS: All surgical options provided impressive outcomes. Premium monovision appeared to deliver the best results.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Refração Ocular , Pseudofacia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Catarata/complicações , Satisfação do Paciente
19.
Curr Opin Ophthalmol ; 35(1): 28-33, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37910172

RESUMO

PURPOSE OF REVIEW: Options for addressing presbyopia with intraocular lens (IOL) implantation have become more varied and sophisticated. We reviewed recent literature on multifocal and extended depth of focus (EDOF) IOLs in order to provide insight on their respective advantages, with emphasis on the visual outcomes of each design. RECENT FINDINGS: Increased patient age, spectral domain optical coherence tomography (SD-OCT) abnormalities, abnormal optical axis measurements, and better preoperative visual acuity have been implicated as predictors of worse postoperative vision or visual quality in multifocal IOLs. Despite differences in objective outcomes, patient-reported outcomes such as satisfaction are consistently similar between multifocal and EDOF IOLs. EDOFs may have slightly lower rates of spectacle independence than trifocals, but there is more support for their use in the setting of with other ocular conditions. SUMMARY: Multifocal and EDOF IOLs are both viable options for patients who wish to preserve near vision. Given their similar objective performance in many aspects, enabling patients to make informed decisions based on their expectations and visual requirements is critical to postoperative satisfaction. Evidence for advanced technology IOL implantation in pediatric patients remains inconclusive.


Assuntos
Linfoma Intraocular , Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Presbiopia , Humanos , Implante de Lente Intraocular/métodos , Satisfação do Paciente , Presbiopia/cirurgia , Desenho de Prótese , Pseudofacia , Refração Ocular , Acuidade Visual
20.
Clin Exp Ophthalmol ; 52(1): 31-41, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38050340

RESUMO

BACKGROUND: To evaluate the intraindividual visual performance of a spherical and extended depth of field (EDOF) IOL used in a mix-and-match approach. METHODS: Single centre (tertiary care centre), retrospective consecutive case series. Included patients had uneventful cataract surgery with implantation of a spherical monofocal IOL (CT Spheris 204) in the dominant eye and a diffractive EDOF IOL (AT LARA 829) in the non-dominant eye. Monocular and binocular defocus curves and visual acuity at various distances were assessed. In addition, binocular reading speed, contrast sensitivity, and patient satisfaction using QOV, Catquest 9SF, and glare/halo questionnaires are reported. RESULTS: A total of 29 patients (58 eyes) were included. We observed significant intra-individual differences for monocular DCIVA, DCNVA, UIVA, and UNVA. There were no differences in monocular BCDVA or UDVA. The monocular defocus curves for the two IOLs significantly differed at defocus steps between -1.0 and -3.5 D. 93.10% of patients reported they would opt for the same combination of IOLs. CONCLUSION: Excellent uncorrected and corrected distance visual acuity was demonstrated in both groups. The mix-and-match approach described in this study yielded good intermediate vision and improved near vision with high-patient satisfaction.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Refração Ocular , Implante de Lente Intraocular , Pseudofacia , Estudos Retrospectivos , Visão Binocular , Satisfação do Paciente , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...