Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.538
Filtrar
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696675

RESUMO

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Masculino , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Imageamento Tridimensional , Cateteres Cardíacos , Fatores de Tempo , Desenho de Equipamento , Estudos Prospectivos , Recidiva
2.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38701222

RESUMO

AIMS: Pulsed field ablation (PFA) for the treatment of atrial fibrillation (AF) potentially offers improved safety and procedural efficiencies compared with thermal ablation. Opportunities remain to improve effective circumferential lesion delivery, safety, and workflow of first-generation PFA systems. In this study, we aim to evaluate the initial clinical experience with a balloon-in-basket, 3D integrated PFA system with a purpose-built form factor for pulmonary vein (PV) isolation. METHODS AND RESULTS: The VOLT CE Mark Study is a pre-market, prospective, multi-centre, single-arm study to evaluate the safety and effectiveness of the Volt™ PFA system for the treatment of paroxysmal (PAF) or persistent AF (PersAF). Feasibility sub-study subjects underwent phrenic nerve evaluation, endoscopy, chest computed tomography, and cerebral magnetic resonance imaging. Study endpoints were the rate of primary serious adverse event within 7 days and acute procedural effectiveness. A total of 32 subjects (age 61.6 ± 9.6 years, 65.6% male, 84.4% PAF) were enrolled and treated in the feasibility sub-study and completed a 30-day follow-up. Acute effectiveness was achieved in 99.2% (127/128) of treated PVs (96.9% of subjects, 31/32) with 23.8 ± 4.2 PFA applications/subject. Procedure, fluoroscopy, LA dwell, and transpired ablation times were 124.6 ± 28.1, 19.8 ± 8.9, 53.0 ± 21.0, and 48.0 ± 19.9 min, respectively. Systematic assessments of initial safety revealed no phrenic nerve injury, pulmonary vein stenosis, or oesophageal lesions causally related to the PFA system and three subjects with silent cerebral lesions (9.4%). There were no primary serious adverse events. CONCLUSION: The initial clinical use of the Volt PFA System demonstrates acute safety and effectiveness in the treatment of symptomatic, drug refractory AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Estudos de Viabilidade , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Idoso , Desenho de Equipamento , Nervo Frênico/lesões , Fatores de Tempo
3.
J Vis Exp ; (206)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38709062

RESUMO

Radiofrequency (RF) ablation to perform pulmonary vein isolation (PVI) for the treatment of atrial fibrillation involves some risk to collateral structures, including the esophagus. Proactive esophageal cooling using a dedicated device has been granted marketing authorization by the Food and Drug Administration (FDA) to reduce the risk of ablation-related esophageal injury due to RF cardiac ablation procedures, and more recent data also suggest that esophageal cooling may contribute to improved long-term efficacy of treatment. A mechanistic underpinning explaining these findings exists through the quantification of lesion placement contiguity defined as the Continuity Index (CI). Kautzner et al. quantified the CI by the order of lesion placement, such that whenever a lesion is placed non-adjacent to the prior lesion, the CI is incremented by the number of segments the catheter tip has moved over. To facilitate real-time calculation of the CI and encourage further adoption of this instrument, we propose a modification in which the placement of non-adjacent lesions increments the CI by only one unit, avoiding the need to count potentially nebulous markers of atrial segmentation. The objective of this protocol is to describe the methods of calculating the CI both prospectively during real-time PVI cases and retrospectively using recorded case data. A comparison of the results obtained between cases that utilized proactive esophageal cooling and cases that used luminal esophageal temperature (LET) monitoring is then provided.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Esôfago , Fibrilação Atrial/cirurgia , Esôfago/cirurgia , Humanos , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia
4.
Med Sci Monit ; 30: e943526, 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38734884

RESUMO

BACKGROUND A significant number of atrial fibrillation (AF) recurrences occur after initial ablation, often due to pulmonary vein reconnections or triggers from non-pulmonary veins. MATERIAL AND METHODS Patients with paroxysmal AF who underwent radiofrequency catheter ablation for the first time were enrolled. Base on propensity score matching (1: 1 matching), 118 patients were selected for an optimized workflow for the radiofrequency catheter ablation of paroxysmal AF (OWCA) group and a conventional group. Comparative analysis of the acute and 12-month clinical outcomes was conducted. Moreover, an artificial intelligence analytics platform was used to evaluate the quality of pulmonary vein isolation (PVI) circles. RESULTS PVI was successfully achieved in all patients. Incidence of first-pass isolation of bilateral PVI circles was higher (P=0.009) and acute pulmonary vein reconnections was lower (P=0.027) in the OWCA group than conventional group. The OWCA group displayed a significant reduction in the number of fractured points (P<0.001), stacked points (P=0.003), and a greater proportion of cases in which the radiofrequency index achieved the target value (P=0.003). Additionally, the contact force consistently met the force over time criteria (P<0.001) for bilateral PVI circles in the OWCA group, accompanied by a shorter operation time (P=0.017). During the 12-month follow-up period, the OWCA group exhibited a higher atrial arrhythmia-free survival rate following the initial ablation procedure than did the conventional group. CONCLUSIONS The optimized workflow for radiofrequency catheter ablation of paroxysmal AF could play a crucial role in creating higher quality PVI circles. This improvement is reflected in a significantly elevated 12-month atrial arrhythmia-free survival rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fluxo de Trabalho , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Veias Pulmonares/cirurgia , Idoso , Pontuação de Propensão , Recidiva
6.
Kyobu Geka ; 77(5): 394-398, 2024 May.
Artigo em Japonês | MEDLINE | ID: mdl-38720610

RESUMO

A 73-year-old woman presented with left anterior chest pain and back pain. Computed tomography (CT) scan showed an anterior mediastinal tumor. It also showed partial anomalous pulmonary venous drainage (left superior pulmonary vein draining into the left brachiocephalic vein), and the tumor was located near the left brachiocephalic vein. The operation was performed through a median sternotomy to resect the thymus and tumor with partial resection of the left upper lobe due to the tumor's adhesion to the left upper lobe. One of the vascular anomalies encountered in adult thoracic surgery is partial anomalous pulmonary venous drainage. It is important to recognize the presence of such an anomaly on imaging and to anticipate the surgical procedure with a preoperative surgical technique.


Assuntos
Veias Pulmonares , Timoma , Neoplasias do Timo , Tomografia Computadorizada por Raios X , Humanos , Feminino , Idoso , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Timoma/cirurgia , Timoma/diagnóstico por imagem , Timoma/complicações , Neoplasias do Timo/cirurgia , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/complicações
7.
BMJ Case Rep ; 17(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38749528

RESUMO

Scimitar syndrome is characterised by right lung hypoplasia and abnormal pulmonary venous return, known as the 'scimitar vein'. We report the case of an infant girl with scimitar syndrome who developed a severe respiratory distress mimicking asthma. Pulmonary hypertension (PH) was diagnosed, attributed to scimitar vein stenosis and a left-to-right shunt. Scimitar vein stenosis, a rare complication of scimitar syndrome, can lead to severe PH, highlighting the importance of prompt management in specialised care centres.


Assuntos
Síndrome de Cimitarra , Humanos , Síndrome de Cimitarra/diagnóstico por imagem , Síndrome de Cimitarra/complicações , Síndrome de Cimitarra/diagnóstico , Feminino , Lactente , Constrição Patológica , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/diagnóstico , Diagnóstico Diferencial , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/diagnóstico
8.
J Am Coll Cardiol ; 83(20): 2015-2027, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38749620

RESUMO

The identification of the pulmonary veins as a trigger source for atrial fibrillation (AF) has established pulmonary vein isolation (PVI) as a key target for AF ablation. However, PVI alone does not prevent recurrent AF in many patients, and numerous additional ablation strategies have failed to improve on PVI outcomes. This therapeutic limitation may be due, in part, to a failure to identify and intervene specifically on the pro-fibrillatory substrate within the atria and pulmonary veins. In this review paper, we highlight several emerging approaches with clinical potential that target atrial cardiomyopathy-the underlying anatomic, electrical, and/or autonomic disease affecting the atrium-in various stages of practice and investigation. In particular, we consider the evolving roles of risk factor modification, targeting of epicardial adipose tissue, tissue fibrosis, oxidative stress, and the inflammasome, along with aggressive early anti-AF therapy in AF management. Attention to combatting substrate development promises to improve outcomes in AF.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Humanos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
9.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38597211

RESUMO

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Fenótipo , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
11.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38682165

RESUMO

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation. Confirmation of PVI can be challenging due to the presence of far-field electrograms (EGMs) and sometimes requires additional pacing manoeuvres or mapping. This prospective multicentre study assessed the agreement between a previously trained automated algorithm designed to determine vein isolation status with expert opinion in a real-world clinical setting. METHODS AND RESULTS: Consecutive patients scheduled for PVI were recruited at four centres. The ECGenius electrophysiology (EP) recording system (CathVision ApS, Copenhagen, Denmark) was connected in parallel with the existing system in the laboratory. Electrograms from a circular mapping catheter were annotated during sinus rhythm at baseline pre-ablation, time of isolation, and post-ablation. The ground truth for isolation status was based on operator opinion. The algorithm was applied to the collected PV signals off-line and compared with expert opinion. The primary endpoint was a sensitivity and specificity exceeding 80%. Overall, 498 EGMs (248 at baseline and 250 at PVI) with 5473 individual PV beats from 89 patients (32 females, 62 ± 12 years) were analysed. The algorithm performance reached an area under the curve (AUC) of 92% and met the primary study endpoint with a sensitivity and specificity of 86 and 87%, respectively (P = 0.005; P = 0.004). The algorithm had an accuracy rate of 87% in classifying the time of isolation. CONCLUSION: This study validated an automated algorithm using machine learning to assess the isolation status of pulmonary veins in patients undergoing PVI with different ablation modalities. The algorithm reached an AUC of 92%, with both sensitivity and specificity exceeding the primary study endpoints.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Aprendizado de Máquina , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Feminino , Masculino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Técnicas Eletrofisiológicas Cardíacas/métodos , Resultado do Tratamento , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Potenciais de Ação , Frequência Cardíaca , Algoritmos , Processamento de Sinais Assistido por Computador
12.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38624037

RESUMO

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Assuntos
Fibrilação Atrial , Índice de Massa Corporal , Criocirurgia , Obesidade , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Idoso , Resultado do Tratamento , Fatores de Risco , Veias Pulmonares/cirurgia , Obesidade/complicações , Magreza/complicações , Fatores de Tempo , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
13.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38647070

RESUMO

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Técnicas de Sutura , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Técnicas de Sutura/efeitos adversos , Idoso , Resultado do Tratamento , Alemanha , Fatores de Tempo , Dispositivos de Oclusão Vascular , Deambulação Precoce , Técnicas Hemostáticas/instrumentação
14.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38655693

RESUMO

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Estudos Prospectivos , Idoso , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação , Eletrocardiografia Ambulatorial/instrumentação , Recidiva , Cateteres Cardíacos , Valor Preditivo dos Testes , Resultado do Tratamento , Imageamento Tridimensional , Fatores de Risco , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas
15.
World J Pediatr Congenit Heart Surg ; 15(3): 319-324, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38654425

RESUMO

Background: We aim to determine the surgical outcomes of adult patients with total anomalous pulmonary venous connection (TAPVC) and examine the regression of pulmonary artery (PA) pressures after the procedure. Methods: We reviewed the hospital records from 2003 to 2022 and identified 49 adult patients with TAPVC. We assessed their surgical outcomes and the trend of PA pressures after the procedure. Continuous data are presented as mean ± SD or median (interquartile range) and categorical variables are presented as percentages. Results: The median age of the patients was 23 years (range 18-42) and 31 (63.3%) were male. Thirty-six patients (73.5%) had supracardiac TAPVC. The mean systolic PA pressure was 65.8 ± 16.4 mm Hg and it decreased by 47.9% (34%, 61.8%) after surgery. Moderate or more tricuspid regurgitation was seen in 27 (55.1%) patients before surgery; however, it was present in only 3 (6.1%) patients during early follow-up. There was no intraoperative or 30-day mortality, and the median hospital length of stay was six days. Long-term follow-up data were available for 29 patients with the average duration of follow-up being 5.6 years (range 6 months to 15 years) and the mean systolic PA pressures of this cohort was 29.8±7.9 mm Hg. Forty-six (93.1%) patients were asymptomatic; four women had uneventful pregnancies and delivered healthy children. Conclusion: Surgical repair of the naturally selected group of adult TAPVC patients can be performed safely with good results. Regression in flow-related pulmonary hypertension and an improvement in functional quality of life are seen in nearly all patients.


Assuntos
Síndrome de Cimitarra , Humanos , Feminino , Masculino , Adulto , Adolescente , Síndrome de Cimitarra/cirurgia , Adulto Jovem , Estudos Retrospectivos , Artéria Pulmonar/cirurgia , Artéria Pulmonar/anormalidades , Resultado do Tratamento , Seguimentos , Procedimentos Cirúrgicos Cardíacos/métodos , Veias Pulmonares/cirurgia , Veias Pulmonares/anormalidades
16.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584468

RESUMO

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação
17.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38588039

RESUMO

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Assuntos
Fibrilação Atrial , Criocirurgia , Traumatismos dos Nervos Periféricos , Nervo Frênico , Veias Pulmonares , Sistema de Registros , Humanos , Nervo Frênico/lesões , Masculino , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Veias Pulmonares/cirurgia , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Estudos Prospectivos , Incidência , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/epidemiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Pessoa de Meia-Idade , Resultado do Tratamento , Ablação por Cateter/efeitos adversos
18.
BMJ Case Rep ; 17(4)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38663900

RESUMO

A pulmonary venous aneurysm (PVA) is extremely rare. A PVA can be either congenital or acquired. Possible symptoms include thoracic pain, dyspnoea, haemoptysis and palpitations but can also occur asymptomatically. Treatment can be conservative or surgical depending on growth and risk of rupture or development of mitral insufficiency, symptoms and thrombus formation. Only a few cases have been described in the literature. A recent case study and a literature review are described below.


Assuntos
Veias Pulmonares , Humanos , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Aneurisma/diagnóstico por imagem , Aneurisma/diagnóstico , Aneurisma/complicações , Masculino , Tomografia Computadorizada por Raios X , Pulmão/diagnóstico por imagem , Pulmão/patologia , Feminino
19.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646926

RESUMO

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Feminino , Masculino , Recidiva , Europa (Continente) , Pessoa de Meia-Idade
20.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646922

RESUMO

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Esôfago , Traumatismos do Nervo Vago , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Masculino , Feminino , Esôfago/lesões , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Traumatismos do Nervo Vago/etiologia , Traumatismos do Nervo Vago/epidemiologia , Incidência , Idoso , Aprendizado de Máquina , Fatores de Risco , Alemanha/epidemiologia , Queimaduras/epidemiologia , Queimaduras/etiologia , Fatores de Tempo , Resultado do Tratamento , Veias Pulmonares/cirurgia , Nervo Vago
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...