Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43.456
Filtrar
1.
J Photochem Photobiol B ; 255: 112927, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38701631

RESUMO

Since the mechanism underlying real-time acquisition of mechanical strength during laser-induced skin wound fusion remains unclear, and collagen is the primary constituent of skin tissue, this study investigates the structural and mechanical alterations in collagen at temperatures ranging from 40 °C to 60 °C using various spectroscopic techniques and molecular dynamics calculations. The COMSOL Multiphysics coupling is employed to simulate the three-dimensional temperature field, stress-strain relationship, and light intensity distribution in the laser thermal affected zone of skin wounds during dual-beam laser welding process. Raman spectroscopy, synchronous fluorescence spectroscopy and circular dichroism measurement results confirm that laser energy activates biological activity in residues, leading to a transformation in the originally fractured structure of collagen protein for enhanced mechanical strength. Molecular dynamics simulations reveal that stable hydrogen bonds form at amino acid residues within the central region of collagen protein when the overall temperature peak around the wound reaches 60 °C, thereby providing stability to previously fractured skin incisions and imparting instantaneous strength. However, under a 55 °C system, Type I collagen ensures macrostructural stability while activating biological properties at amino acid bases to promote wound healing function; this finding aligns with experimental analysis results. The COMSOL simulation outcomes also correspond well with macroscopic morphology after laser welding samples, confirming that by maintaining temperatures between 55 °C-60 °C during laser welding of skin incisions not only can certain instantaneous mechanical strength be achieved but irreversible thermal damage can also be effectively controlled. It is anticipated that these findings will provide valuable insights into understanding the healing mechanism for laser-welded skin wounds.


Assuntos
Colágeno , Lasers , Simulação de Dinâmica Molecular , Pele , Análise Espectral Raman , Pele/química , Pele/efeitos da radiação , Colágeno/química , Colágeno/metabolismo , Cicatrização , Ligação de Hidrogênio , Análise de Elementos Finitos , Animais , Dicroísmo Circular , Temperatura , Espectrometria de Fluorescência
2.
J Pharm Biomed Anal ; 245: 116184, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692214

RESUMO

The plant of Paeonia lactiflora Pall. belongs to Ranunculaceae, and its root can be divided into two categories according to different processing methods, which included that one was directly dried without peeling the root of the P. lactiflora (PR), and the other was peeled the root of the P. lactiflora (PPR) after boiled and dried. To evaluate the difference of chemical components, UPLC-ESI-Q-Exactive Focus-MS/MS and UPLC-QQQ-MS were applied. The distribution of chemical components in different tissues was located by laser microdissection (LMD), especially the different ingredients. A total of 86 compounds were identified from PR and PPR. Four kind of tissues were isolated from the fresh root of the P. lactiflora (FPR), and 54 compounds were identified. Especially the content of gallic acid, albiflorin, and paeoniflorin with high biological activities were the highest in the cork, but they were lower in PR than that in PPR, which probably related to the process. To illustrate the difference in pharmacological effects of PR and PPR, the tonifying blood and analgesic effects on mice were investigated, and it was found that the tonifying blood and analgesic effects of PPR was superior to that of PR, even though PR had more constituents. The material basis for tonifying blood and analgesic effect of the root of P. lactiflora is likely to be associated with an increase in constituents such as paeoniflorin and paeoniflorin lactone after boiled and peeled. The study was likely to provide some theoretical support for the standard and clinical application.


Assuntos
Glucosídeos , Monoterpenos , Paeonia , Raízes de Plantas , Espectrometria de Massas em Tandem , Paeonia/química , Raízes de Plantas/química , Animais , Camundongos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Glucosídeos/análise , Glucosídeos/química , Masculino , Monoterpenos/farmacologia , Monoterpenos/análise , Monoterpenos/química , Microdissecção/métodos , Ácido Gálico/análise , Ácido Gálico/química , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Lasers , Analgésicos/farmacologia , Analgésicos/química , Analgésicos/análise , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/farmacologia , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massa com Cromatografia Líquida , Hidrocarbonetos Aromáticos com Pontes
3.
Stomatologiia (Mosk) ; 103(2): 86-90, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38741541

RESUMO

The paper presents an overview of modern scientific data on the study of the effect of laser radiation on biological tissues of the mouth in the therapeutic treatment of dental diseases. The use of lasers in the treatment of dental caries and its complications, non-carious lesions of hard dental tissues, as well as the use of lasers in the treatment of periodontal diseases and aesthetic restoration of teeth is considered.


Assuntos
Terapia a Laser , Humanos , Terapia a Laser/métodos , Cárie Dentária/terapia , Doenças Periodontais/terapia , Terapia com Luz de Baixa Intensidade/métodos , Lasers
4.
Sci Rep ; 14(1): 11173, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750179

RESUMO

Laser weeding may contribute to less dependency on herbicides and soil tillage. Several research and commercial projects are underway to develop robots equipped with lasers to control weeds. Artificial intelligence can be used to locate and identify weed plants, and mirrors can be used to direct a laser beam towards the target to kill it with heat. Unlike chemical and mechanical weed control, laser weeding only exposes a tiny part of the field for treatment. Laser weeding leaves behind only ashes from the burned plants and does not disturb the soil. Therefore, it is an eco-friendly method to control weed seedlings. However, perennial weeds regrow from the belowground parts after the laser destroys the aerial shoots. Depletion of the belowground parts for resources might be possible if the laser continuously kills new shoots, but it may require many laser treatments. We studied how laser could be used to destroy the widespread and aggressive perennial weed Elymus repens after the rhizomes were cut into fragments. Plants were killed with even small dosages of laser energy and stopped regrowing. Generally, the highest efficacy was achieved when the plants from small rhizomes were treated at the 3-leaf stage.


Assuntos
Lasers , Controle de Plantas Daninhas , Controle de Plantas Daninhas/métodos , Elymus/crescimento & desenvolvimento , Plantas Daninhas/crescimento & desenvolvimento , Folhas de Planta/crescimento & desenvolvimento , Folhas de Planta/efeitos da radiação
5.
J Dig Dis ; 25(3): 191-199, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38697920

RESUMO

OBJECTIVE: To compare the detection rate and diagnostic accuracy of cardia polyps using endoscopy with blue laser imaging (BLI) and white-light imaging (WLI). METHODS: Patients were randomly divided into the BLI group and WLI group according to the endoscopic procedures. BLI followed by WLI was conducted in the BLI group, whereas WLI followed by BLI examination was conducted in the WLI group. The number, size, microstructure, and microvascular patterns of cardia polyps detected were recorded. Biopsy of the polyps was then performed. RESULTS: The detection rate of cardia polyps in the BLI group was higher than that in the WLI group (7.87% vs 4.22%, P = 0.018). The rate of overlooked lesions in the BLI group was lower than in the WLI group (0.64% vs 3.38%, P = 0.003). The diagnostic coincidence rate between magnifying BLI and histopathology was 88.16%. The sensitivity, specificity, positive predictive value and negative predictive value for the diagnosis of neoplastic lesions by magnifying endoscopy with BLI were 90.91%, 87.69%, 55.56%, and 98.28%, respectively. The most remarkable patterns for predicting inflammatory polyps were the prolonged and fine network patterns (sensitivity 71.43%, specificity 93.75%). Small round combined with honeycomb patterns were the most common among fundic gland polyps (sensitivity 80.00%, specificity 98.48%). Neoplastic lesions presented as villous or ridge-like combined with core vascular or unclear pattern for both microvascular and microstructure patterns. CONCLUSION: BLI is more effective than WLI in the detection and diagnosis of cardia polyps, and magnifying endoscopy with BLI may help diagnose such lesions.


Assuntos
Cárdia , Estudos de Viabilidade , Neoplasias Gástricas , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cárdia/patologia , Cárdia/diagnóstico por imagem , Adulto , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/patologia , Idoso , Pólipos/diagnóstico por imagem , Pólipos/diagnóstico , Gastroscopia/métodos , Sensibilidade e Especificidade , Valor Preditivo dos Testes , Lasers
6.
Bioorg Chem ; 147: 107398, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38691907

RESUMO

Herein, we report a multifaceted nanoformulation, developed by binding thionine acetate (TA) in silica matrix to form TA loaded silica nanoparticles (STA Nps), which were characterized using various physicochemical techniques. STA NPs were spherical shaped having size 40-50 nm and exhibited good heating efficiency, improved photostability and singlet oxygen production rate than TA alone. In PDT experiment, the rate of degradation for ABDMA was enhanced from 0.1367 min-1 for TA alone to 0.1774 min-1 for STA Nps, depicting an increase in the reactive oxygen species (ROS) generation ability of STA Nps. Further, the cytotoxicity of STA Nps was investigated by carrying out the biophysical studies with Calf thymus DNA (Ct-DNA) and Human Serum Albumin (HSA). The results indicated that the binding of STA Nps to Ct-DNA causes alterations in the double helix structure of DNA and as a result, STA Nps can impart chemotherapeutic effects via targeting DNA. STA Nps showed good binding affinity with HSA without compromising the structure of HSA, which is important for STA Nps sustainable biodistribution and pharmacokinetics. Based on this study, it is suggested that because of the synergistic effect of chemo and phototherapy, STA Nps can be extensively utilized as potential candidates for treating cancer.


Assuntos
Antineoplásicos , Lasers , Nanopartículas , Fenotiazinas , Dióxido de Silício , Humanos , Dióxido de Silício/química , Nanopartículas/química , Antineoplásicos/química , Antineoplásicos/farmacologia , Antineoplásicos/síntese química , Fenotiazinas/química , Fenotiazinas/farmacologia , Fenotiazinas/síntese química , Albumina Sérica Humana/química , DNA/química , Ensaios de Seleção de Medicamentos Antitumorais , Relação Dose-Resposta a Droga , Estrutura Molecular , Animais , Espécies Reativas de Oxigênio/metabolismo , Sobrevivência Celular/efeitos dos fármacos , Fármacos Fotossensibilizantes/química , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/síntese química , Fotoquimioterapia , Proliferação de Células/efeitos dos fármacos , Bovinos , Relação Estrutura-Atividade
7.
Biosens Bioelectron ; 258: 116327, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38703496

RESUMO

Proper customization in size and shape is essential in implantable bioelectronics for stable bio-signal recording. Over the past decades, many researchers have heavily relied on conventional photolithography processes to fabricate implantable bioelectronics. Therefore, they could not avoid the critical limitation of high cost and complex processing steps to optimize bioelectronic devices for target organs with various sizes and shapes. Here, we propose rapid prototyping using all laser processes to fabricate customized bioelectronics. PEDOT:PSS is selectively irradiated by an ultraviolet (UV) pulse laser to form wet-stable conductive hydrogels that can softly interact with biological tissues (50 µm line width). The encapsulation layer is selectively patterned using the same laser source by UV-curing polymer networks (110 µm line width). For high stretchability (over 100%), mesh structures are made by the selective laser cutting process. Our rapid prototyping strategy minimizes the use of high-cost equipment, using only a single UV laser source to process the electrodes, encapsulation, and substrates that constitute bioelectronics without a photomask, enabling the prototyping stretchable microelectrode array with an area of 1 cm2 less than 10 min. We fabricated an optimized stretchable microelectrode array with low impedances (∼1.1 kΩ at 1 kHz) that can effectively record rat's cardiac signals with various health states.


Assuntos
Técnicas Biossensoriais , Condutividade Elétrica , Hidrogéis , Lasers , Hidrogéis/química , Animais , Técnicas Biossensoriais/instrumentação , Ratos , Polímeros/química , Desenho de Equipamento , Poliestirenos/química , Tiofenos
8.
Sci Adv ; 10(19): eadl1586, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38718128

RESUMO

Viscoelastic transformation of tissue drives aberrant cellular functions and is an early biomarker of disease pathogenesis. Tissues scale a range of viscoelastic moduli, from biofluids to bone. Moreover, viscoelastic behavior is governed by the frequency at which tissue is probed, yielding distinct viscous and elastic responses modulated over a wide frequency band. Existing tools do not quantify wideband viscoelastic spectra in tissues, leaving a vast knowledge gap. We present wideband laser speckle rheological microscopy (WB-SHEAR) that reveals elastic and viscous response over sub-megahertz frequencies previously not investigated in tissue. WB-SHEAR uses an optical, noncontact approach to quantify wideband viscoelastic spectra in specimens spanning a range of moduli from low-viscosity fibrin to highly elastic bone. Via laser scanning, micromechanical imaging is enabled to access wideband viscoelastic spectra in heterogeneous tumor specimens with high spatial resolution (25 micrometers). The ability to interrogate the viscoelastic landscape of diverse biospecimens could transform our understanding of mechanobiological processes in various diseases.


Assuntos
Elasticidade , Reologia , Viscosidade , Reologia/métodos , Humanos , Animais , Lasers , Microscopia/métodos
9.
Biomed Phys Eng Express ; 10(4)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38718764

RESUMO

Evaluation of skin recovery is an important step in the treatment of burns. However, conventional methods only observe the surface of the skin and cannot quantify the injury volume. Optical coherence tomography (OCT) is a non-invasive, non-contact, real-time technique. Swept source OCT uses near infrared light and analyzes the intensity of light echo at different depths to generate images from optical interference signals. To quantify the dynamic recovery of skin burns over time, laser induced skin burns in mice were evaluated using deep learning of Swept source OCT images. A laser-induced mouse skin thermal injury model was established in thirty Kunming mice, and OCT images of normal and burned areas of mouse skin were acquired at day 0, day 1, day 3, day 7, and day 14 after laser irradiation. This resulted in 7000 normal and 1400 burn B-scan images which were divided into training, validation, and test sets at 8:1.5:0.5 ratio for the normal data and 8:1:1 for the burn data. Normal images were manually annotated, and the deep learning U-Net model (verified with PSPNe and HRNet models) was used to segment the skin into three layers: the dermal epidermal layer, subcutaneous fat layer, and muscle layer. For the burn images, the models were trained to segment just the damaged area. Three-dimensional reconstruction technology was then used to reconstruct the damaged tissue and calculate the damaged tissue volume. The average IoU value and f-score of the normal tissue layer U-Net segmentation model were 0.876 and 0.934 respectively. The IoU value of the burn area segmentation model reached 0.907 and f-score value reached 0.951. Compared with manual labeling, the U-Net model was faster with higher accuracy for skin stratification. OCT and U-Net segmentation can provide rapid and accurate analysis of tissue changes and clinical guidance in the treatment of burns.


Assuntos
Queimaduras , Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Lasers , Pele , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Animais , Queimaduras/diagnóstico por imagem , Camundongos , Pele/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
10.
Med Eng Phys ; 127: 104170, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692767

RESUMO

Recently, functional Near-Infrared Spectroscopy (fNIRS) was applied to obtain, non-invasively, the human peri­spinal Neuro-Vascular Response (NVR) under a non-noxious electrical stimulation of a peripheral nerve. This method allowed the measurements of changes in the concentration of oxyhemoglobin (O2Hb) and deoxyhemoglobin (HHb) from the peri­spinal vascular network. However, there is a lack of clarity about the potential differences in perispinal NVR recorded by the different fNIRS technologies currently available. In this work, the two main noninvasive fNIRS technologies were compared, i.e., LED and LASER-based. The recording of the human peri­spinal NVR induced by non-noxious electrical stimulation of a peripheral nerve was recorded simultaneously at C7 and T10 vertebral levels. The amplitude, rise time, and full width at half maximum duration of the perispinal NVRs were characterized in healthy volunteers and compared between both systems. The main difference was that the LED-based system shows about one order of magnitude higher values of amplitude than the LASER-based system. No statistical differences were found for rise time and for duration parameters (at thoracic level). The comparison of point-to-point wave patterns did not show significant differences between both systems. In conclusion, the peri­spinal NRV response obtained by different fNIRS technologies was reproducible, and only the amplitude showed differences, probably due to the power of the system which should be considered when assessing the human peri­spinal vascular network.


Assuntos
Lasers , Espectroscopia de Luz Próxima ao Infravermelho , Medula Espinal , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Medula Espinal/irrigação sanguínea , Medula Espinal/diagnóstico por imagem , Medula Espinal/fisiologia , Adulto , Feminino , Adulto Jovem , Estimulação Elétrica , Hemoglobinas/análise , Hemoglobinas/metabolismo
11.
Anal Chim Acta ; 1306: 342617, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692789

RESUMO

BACKGROUND: Alpha-fetoprotein (AFP) is a fetal protein that can indicate congenital anomalies such as Down syndrome and spinal canal blockage when detected at abnormal levels in pregnant women. Current AFP detection methods rely on invasive blood or serum samples, which require sophisticated equipment. From the many solutions proposed, colorimetric paper-based assays excel in point-of-care settings. The concept of paper-based ELISA (p-ELISA) enhances traditional methods, aligning with the ASSURED criteria for diagnostics in resource-limited regions. Despite success in microfluidic paper-based assay devices, laser printing remains underexplored for p-ELISA. Additionally, modifying the paper surface provides an additional layer of sensitivity enhancement. RESULTS: In this study, we developed a novel laser-printed paper-based ELISA (LP-pELISA) for rapid, sensitive, and noninvasive detection of AFP in saliva samples. The LP-pELISA platform was fabricated by printing hydrophobic barriers on filter paper using a laser printer, followed by depositing hydroxyapatite (HAp) as an immobilization material for the antibodies. The colorimetric detection was achieved using AuNPs functionalized with anti-AFP antibodies and silver nitrate enhancement. The LP-pELISA exhibited a linear response for AFP detection in both buffer and saliva samples over a range of 1.0-800 ng mL-1, with a limit of detection (LOD) reaching 1.0 ng mL-1. The assay also demonstrated good selectivity, repeatability, reproducibility, and stability. The LP-pELISA was further validated by testing spiked human saliva samples, showing its potential for point-of-care diagnosis of congenital disabilities. SIGNIFICANCE: The LP-pELISA is a noninvasive platform showcasing simplicity, cost-effectiveness, and user-friendliness, utilizing laser printing, hydroxyapatite modification, and saliva samples to efficiently detect AFP. Beyond its application for AFP, this method's versatility extends to other biomarkers, positioning it as a catalyst for the evolution of paper-based biosensors. The LP-pELISA holds promise as a transformative tool for point-of-care diagnostics, fostering advancements in healthcare with its innovative technology.


Assuntos
Colorimetria , Durapatita , Ensaio de Imunoadsorção Enzimática , Lasers , Papel , Saliva , alfa-Fetoproteínas , Humanos , Saliva/química , Durapatita/química , alfa-Fetoproteínas/análise , Impressão , Ouro/química , Limite de Detecção , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química
12.
Immunohorizons ; 8(5): 363-370, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38775688

RESUMO

Although the pathogenesis of choroidal neovascularization (CNV) is largely unknown in age-related macular degeneration (AMD), inflammasomes may contribute to CNV development and progression. To understand the role NLRP3 inflammasomes in CNV, we used Ccr2RFPCx3cr1GFP dual-reporter mice and immunostaining techniques to confirm localization of NLRP3 inflammasomes in the laser-induced CNV (LCNV) lesions. Confocal microscopy was used to image and quantify LCNV volumes. MCC950 was used as NLRP3 inhibitor. ELISA and quantitative RT-PCR were used to confirm the activation of NLRP3 by monitoring the expression of IL-1ß protein and mRNA in choroidal tissues from LCNV mice. In addition, NLRP3 (-/-) LCNV mice were used to investigate whether NLRP3 inflammasomes contribute to the development of LCNV lesions. We observed that red fluorescent protein (RFP)-positive monocyte-derived macrophages and GFP-positive microglia-derived macrophages, in addition to other cell types, were localized in LCNV lesions at day 7 post-laser injury. In addition, NLRP3 inflammasomes are associated with LCNV lesions. Inhibition of NLRP3 inflammasomes, using MCC950, caused an increased Ccr2RFP-positive macrophages, Cx3cr1GFP-positive microglia, and other cells, resulting in an increase in total lesion size. NLRP3 (-/-) LCNV mice showed significantly increased lesion size compared with age-matched controls. Inhibition of NLRP3 resulted in decreased IL-1ß mRNA and protein expression in the choroidal tissues, suggesting that increased lesion size may not be directly related to IL-1ß.


Assuntos
Neovascularização de Coroide , Indenos , Inflamassomos , Interleucina-1beta , Microglia , Monócitos , Proteína 3 que Contém Domínio de Pirina da Família NLR , Animais , Proteína 3 que Contém Domínio de Pirina da Família NLR/metabolismo , Proteína 3 que Contém Domínio de Pirina da Família NLR/genética , Neovascularização de Coroide/metabolismo , Neovascularização de Coroide/patologia , Camundongos , Inflamassomos/metabolismo , Interleucina-1beta/metabolismo , Microglia/metabolismo , Monócitos/metabolismo , Camundongos Knockout , Sulfonas/farmacologia , Camundongos Endogâmicos C57BL , Furanos/farmacologia , Receptores CCR2/metabolismo , Receptores CCR2/genética , Macrófagos/metabolismo , Macrófagos/imunologia , Sulfonamidas/farmacologia , Compostos Heterocíclicos de 4 ou mais Anéis/farmacologia , Proteínas de Transporte/metabolismo , Proteínas de Transporte/genética , Corioide/metabolismo , Corioide/patologia , Modelos Animais de Doenças , Lasers/efeitos adversos , Degeneração Macular/patologia , Degeneração Macular/metabolismo , Degeneração Macular/genética
13.
Mymensingh Med J ; 33(2): 466-469, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38557527

RESUMO

There are several surgical options described for the treatment of anorectal fistulas, specially in complex cases where recurrence rates and the possibility of postoperative complications are still high. Laser- FiLaC™ has been described in this study as an option in the management of anorectal fistula. The aim of this study was to assess the novel radial laser probe treatment in complex fistula in-ano and report the success rate and recurrence rate. We studied retrospectively 56 patients who, according to our hospital patient records, underwent radial laser probe surgery between March 2019 and August 2020. In a mean follow-up time of 6 months, the success rate at 2 months was 86.0%. Most operations were done under spinal anesthesia. The recovery time was rapid and median sick leave was 7 days. Of those initially successfully treated, 3.0% developed a recurrence. Altogether 4.0% of the patients underwent a re-operation. There is a good success rate using FiLaC™ treatment. FiLaC™ is very effective in treatment of complex fistula and as well as recurrence of fistula. It has a short hospital stay and as well as it is painless surgical technique that should be largely used in our country.


Assuntos
Canal Anal , Fístula Retal , Humanos , Estudos Retrospectivos , Canal Anal/cirurgia , Fístula Retal/cirurgia , Lasers , Resultado do Tratamento
14.
Med Sci Monit ; 30: e943732, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556775

RESUMO

BACKGROUND This study of 60 patients with low back pain (LBP) aimed to compare outcomes following magnetotherapy, ultrasound therapy, laser therapy, and electrotherapy, with and without lumbosacral kinesiotherapy, and used the Roland-Morris Disability Questionnaire (RMDQ) and the Oswestry Low Back Pain Disability Questionnaire (OLBPDQ). This was a randomized actively controlled intervention trial of adding kinesiotherapy to a standard physiotherapy for LBP. MATERIAL AND METHODS The research included 60 participants with a diagnosis of chronic non-specific lumbar pain syndrome (CNSLPS) (mean±SD age 58.3±15.4 years, 37 women) LBP randomly assigned (1: 1) to 2 treatment groups. In Group 1, 30 patients were treated with magnetotherapy, ultrasound therapy, laser therapy, and electrotherapy. In Group 2, 30 patients received the same treatments as in Group 1, and also performed kinesiotherapy exercises affecting the lumbosacral spine and adjacent muscles. At baseline and at the end of the study, all participants completed the RMDQ and the OLBPDQ. RESULTS Both groups had significant improvement after therapy. Repeated-measures ANOVA indicated that at the end of treatment there was significantly greater progress and symptom reduction (P<0.001) in Group 2. Patients in Group 2 had a pain reduction of 52.5%, while Group 1 had 25.4% pain reduction (P=0.009). CONCLUSIONS For treatment of disability caused by CNSLPS, physical therapy combined with kinesiotherapy should be a treatment of choice.


Assuntos
Dor Crônica , Terapia por Estimulação Elétrica , Dor Lombar , Magnetoterapia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Dor Lombar/terapia , Dor Lombar/diagnóstico , Resultado do Tratamento , Dor Crônica/terapia , Lasers
15.
Eur Rev Med Pharmacol Sci ; 28(6): 2396-2402, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38567602

RESUMO

OBJECTIVE: This study investigates the incidence of urinary incontinence following transurethral thulium laser prostatectomy with three different prostate apex disconnection techniques: semi-separation, pre-separation, and post-separation. The findings aim to provide references for clinical treatment. PATIENTS AND METHODS: A retrospective analysis was conducted on 74 patients treated with transurethral thulium laser prostatectomy for prostatic hyperplasia from April 2022 to March 2023. Complete clinical and follow-up data were available for 52 patients. Clinical and follow-up data were collected for these patients. A comparison was made of urinary incontinence following the three different types of prostate apex disconnection in transurethral thulium laser prostatectomy. RESULTS: In this study, the immediate postoperative urinary incontinence rate for transurethral thulium laser prostatectomy was 9.62% (5/52), the short-term incontinence rate was 11.54% (5/52), and the long-term incontinence rate was 9.62% (5/52). The immediate postoperative incontinence rates for semi-separation, pre-separation, and post- separation were 8.33% (1/12), 8.33% (2/24), and 12.5% (2/16), respectively. The short-term incontinence rates for semi-separation, pre-separation, and post-separation were 8.33% (1/12), 8.33% (2/24), and 18.75% (3/16), respectively. The long-term incontinence rates for semi-separation, pre-separation, and post-separation were 8.33% (1/12), 8.33% (2/24), and 12.5% (2/16), respectively. CONCLUSIONS: The incidence of urinary incontinence following transurethral thulium laser prostatectomy was lower with semi-separation and pre-separation compared to post-separation.


Assuntos
Terapia a Laser , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Incontinência Urinária , Masculino , Humanos , Próstata , Túlio/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Ressecção Transuretral da Próstata/efeitos adversos , Terapia a Laser/efeitos adversos , Terapia a Laser/métodos , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/tratamento farmacológico , Incontinência Urinária/epidemiologia , Incontinência Urinária/etiologia , Lasers , Prostatectomia/efeitos adversos , Prostatectomia/métodos
16.
Rapid Commun Mass Spectrom ; 38(12): e9755, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38600731

RESUMO

RATIONALE: Atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry has enabled the untargeted analysis and imaging of neuropeptides and proteins in biological tissues under ambient conditions. Sensitivity in AP-MALDI can be improved by using sample-specific preparation methods. METHODS: A comprehensive and detailed optimization strategy including instrument parameters, matrix spraying and sample tissue washing pretreatment was implemented to enhance the sensitivity and coverage of neuropeptides in mouse pituitary tissues by commercial AP-MALDI mass spectrometry imaging (MSI). RESULTS: The sensitivity of a commercial AP-MALDI system for endogenous neuropeptides in mouse pituitary was enhanced by up to 15.2-fold by shortening the transmission gap from the sample plate to the inlet, attaching copper adhesive tape to an indium tin oxide-coated glass slide, optimizing the matrix spray solvent and using sample tissue washing pretreatment. Following careful optimization, the distributions of nine endogenous neuropeptides were successfully visualized in the pituitary. Furthermore, the quantitative capability of AP-MALDI for neuropeptides was evaluated and the concentrations of neuropeptides oxytocin and vasopressin in the pituitary posterior lobe were increased approximately twofold under hypertonic saline stress. CONCLUSION: Mouse pituitary neuropeptides have emerged as important signaling molecules due to their role in stress response. This work indicates the potential of modified AP-MALDI as a promising AP MSI method for in situ visualization and quantification of neuropeptides in complex biological tissues.


Assuntos
Neuropeptídeos , Camundongos , Animais , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Neuropeptídeos/análise , Pressão Atmosférica , Lasers
17.
Biointerphases ; 19(2)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38602440

RESUMO

In mass spectrometry imaging (MSI), ion suppression can lead to a misinterpretation of results. Particularly phospholipids, most of which exhibit high gas-phase basicity (GB), are known to suppress the detection of metabolites and drugs. This study was initiated by the observation that the signal of an herbicide, i.e., atrazine, was suppressed in MSI investigations of earthworm tissue sections. Herbicide accumulation in earthworms was investigated by time-of-flight secondary ion mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Additionally, earthworm tissue sections without accumulation of atrazine but with a homogeneous spray deposition of the herbicide were analyzed to highlight region-specific ion suppression. Furthermore, the relationship of signal intensity and GB in binary mixtures of lipids, amino acids, and atrazine was investigated in both MSI techniques. The GB of atrazine was determined experimentally through a linear plot of the obtained intensity ratios of the binary amino acid mixtures, as well as theoretically. The GBs values for atrazine of 896 and 906 kJ/mol in ToF-SIMS and 933 and 987 kJ/mol in MALDI-MSI were determined experimentally and that of 913 kJ/mol by quantum mechanical calculations. Compared with the GB of a major lipid component, phosphatidylcholine (GBPC = 1044.7 kJ/mol), atrazine's experimentally and computationally determined GBs in this work are significantly lower, making it prone to ion suppression in biological samples containing polar lipids.


Assuntos
Atrazina , Herbicidas , Oligoquetos , Animais , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Aminoácidos , Fosfatidilcolinas , Lasers
18.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613608

RESUMO

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Hólmio , Túlio , Ureteroscopia , Estudos Prospectivos , Cálculos Renais/cirurgia , Lasers
19.
Neurosurg Rev ; 47(1): 159, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625588

RESUMO

We aim to investigate the efficacy and safety of laser interstitial thermal therapy (LITT) in treating recurrent glioblastomas (rGBMs). A comprehensive search was conducted in four databases to identify studies published between January 2001 and June 2022 that reported prognosis information of rGBM patients treated with LITT as the primary therapy. The primary outcomes of interest were progression-free survival (PFS) and overall survival (OS) at 6 and 12 months after LITT intervention. Adverse events and complications were also evaluated. Eight eligible non-comparative studies comprising 128 patients were included in the analysis. Seven studies involving 120 patients provided data for the analysis of PFS. The pooled PFS rate at 6 months after LITT was 25% (95% CI 15-37%, I2 = 53%), and at 12 months, it was 9% (95% CI 4-15%, I2 = 24%). OS analysis was performed on 54 patients from six studies, with an OS rate of 92% (95% CI 84-100%, I2 = 0%) at 6 months and 42% (95% CI 13-73%, I2 = 67%) at 12 months after LITT. LITT demonstrates a favorable safety profile with low complication rates and promising tumor control and overall survival rates in patients with rGBMs. Tumor volume and performance status are important factors that may influence the effectiveness of LITT in selected patients. Additionally, the combination of LITT with immune-based therapy holds promise. Further well-designed clinical trials are needed to expand the application of LITT in glioma treatment.


Assuntos
Glioblastoma , Glioma , Humanos , Glioblastoma/terapia , Bases de Dados Factuais , Intervalo Livre de Progressão , Lasers
20.
Lasers Surg Med ; 56(4): 371-381, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38563442

RESUMO

OBJECTIVES: To develop and practically test high-precision femtosecond laser ablation models for dental hard tissue that are useful for detailed planning of automated laser dental restorative treatment. METHODS: Analytical models are proposed, derived, and demonstrated for practical calculation of ablation rates, ablation efficiency and ablated morphology of human dental enamel and dentin using femtosecond lasers. The models assume an effective optical attenuation coefficient for the irradiated material. To achieve ablation, it is necessary for the local energy density of the attenuated pulse in the hard tissue to surpass a predefined threshold that signifies the minimum energy density required for material ionization. A 1029 nm, 40 W carbide 275 fs laser was used to ablate sliced adult human teeth and generate the data necessary for testing the models. The volume of material removed, and the shape of the ablated channel were measured using optical profilometry. RESULTS: The models fit with the measured ablation efficiency curve against laser fluence for both enamel and dentin, correctly capturing the fluence for optimum ablation and the volume of ablated material per pulse. The detailed shapes of a 400-micrometer wide channel and a single-pulse width channel are accurately predicted using the superposition of the analytical result for a single pulse. CONCLUSIONS: The findings have value for planning automated dental restorative treatment using femtosecond lasers. The measurements and analysis give estimates of the optical properties of enamel and dentin irradiated with an infrared femtosecond laser at above-threshold fluence and the proposed models give insight into the physics of femtosecond laser processing of dental hard tissue.


Assuntos
Terapia a Laser , Dente , Humanos , Dentina/cirurgia , Lasers , Luz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...