Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.711
Filtrar
1.
Appl Microbiol Biotechnol ; 108(1): 355, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822832

RESUMO

Getah virus (GETV) is a re-emerging mosquito-borne alphavirus that is highly pathogenic, mainly to pigs and horses. There are no vaccines or treatments available for GETV in swine in China. Therefore, the development of a simple, rapid, specific, and sensitive serological assay for GETV antibodies is essential for the prevention and control of GETV. Current antibody monitoring methods are time-consuming, expensive, and dependent on specialized instrumentation, and these features are not conducive to rapid detection in clinical samples. To address these problem, we developed immunochromatographic test strips (ICTS) using eukaryotically expressed soluble recombinant p62-E1 protein of GETV as a labelled antigen, which has good detection sensitivity and no cross-reactivity with other common porcine virus-positive sera. The ICTS is highly compatible with IFA and ELISA and can be stored for 1 month at 37 °C and for at least 3 months at room temperature. Hence, p62-E1-based ICTS is a rapid, accurate, and convenient method for rapid on-site detection of GETV antibodies. KEY POINTS: • We established a rapid antibody detection method that can monitor GETV infection • We developed colloidal gold test strips with high sensitivity and specificity • The development of colloidal gold test strips will aid in the field serologic detection of GETV.


Assuntos
Alphavirus , Anticorpos Antivirais , Coloide de Ouro , Sensibilidade e Especificidade , Animais , Coloide de Ouro/química , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Alphavirus/imunologia , Suínos , Cromatografia de Afinidade/métodos , Infecções por Alphavirus/diagnóstico , Infecções por Alphavirus/imunologia , Doenças dos Suínos/diagnóstico , Doenças dos Suínos/virologia , Fitas Reagentes , China , Ensaio de Imunoadsorção Enzimática/métodos
2.
Microb Pathog ; 191: 106669, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38697231

RESUMO

African swine fever (ASF) is a lethal disease caused by ASF virus (ASFV), severely impacting the global swine industry. Though nuclear acid-based detection methods are reliable, they are laboratory-dependent. In this study, we developed a device-independent, user friendly and cost-effective quantum dots based immunochromatographic strip (QDs-ICS) with high specificity and sensitivity for the rapid and on-site detection of ASFV antigen. For the preparation of the QDs-ICS, we generated a monoclonal antibody (mAb) mAb-8G8 and polyclonal antibody (pAb) against ASFV-p72 protein. The pAb was labelled with QDs to be used as the detection probe and the mAb-8G8 was coated on the nitrocellulose membrane as the test line. Our results proved that the strip displayed no cross-reactivity with other swine viruses and detection limit of the QDs-ICS was down to 1 ng/mL for the ASFV-p72 protein with great reproducibility. The strip also exhibited high stability with a storage period up to 12 months under room temperature. Twenty blind samples and one hundred clinical samples were examined by the QDs-ICS, conventional PCR and real-time PCR method, respectively. Results showed that the agreement rate between the QDs-ICS and PCR method was 100%, and the agreement rate between the strip and real-time PCR was 94%. The novel QDs-ICS developed here would be an effective tool for on-site detection of ASFV.


Assuntos
Vírus da Febre Suína Africana , Febre Suína Africana , Anticorpos Monoclonais , Anticorpos Antivirais , Antígenos Virais , Cromatografia de Afinidade , Pontos Quânticos , Sensibilidade e Especificidade , Vírus da Febre Suína Africana/isolamento & purificação , Vírus da Febre Suína Africana/imunologia , Vírus da Febre Suína Africana/genética , Animais , Febre Suína Africana/diagnóstico , Febre Suína Africana/virologia , Febre Suína Africana/imunologia , Suínos , Anticorpos Monoclonais/imunologia , Anticorpos Antivirais/imunologia , Cromatografia de Afinidade/métodos , Antígenos Virais/análise , Antígenos Virais/imunologia , Reprodutibilidade dos Testes , Fitas Reagentes
3.
Biosens Bioelectron ; 258: 116357, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38729049

RESUMO

The label probe plays a crucial role in enhancing the sensitivity of lateral flow immunoassays. However, conventional fluorescent microspheres (FMs) have limitations due to their short fluorescence lifetime, susceptibility to background fluorescence interference, and inability to facilitate multi-component detection. In this study, carboxylate-modified Eu(III)-chelate-doped polystyrene nanobeads were employed as label probes to construct a multiple time-resolved fluorescent microsphere-based immunochromatographic test strip (TRFM-ICTS). This novel TRFM-ICTS facilitated rapid on-site quantitative detection of three mycotoxins in grains: Aflatoxin B1 (AFB1), Zearalenone (ZEN), and Deoxynivalenol (DON). The limit of detection (LOD) for AFB1, ZEN, and DON were found to be 0.03 ng/g, 0.11 ng/g, and 0.81 ng/g, respectively. Furthermore, the TRFM-ICTS demonstrated a wide detection range for AFB1 (0.05-8.1 ng/g), ZEN (0.125-25 ng/g), and DON (1.0-234 ng/g), while maintaining excellent selectivity. Notably, the test strip exhibited remarkable stability, retaining its detection capability even after storage at 4 °C for over one year. Importantly, the detection of these mycotoxins relied solely on simple manual operations, and with a portable reader, on-site detection could be accomplished within 20 min. This TRFM-ICTS presents a promising solution for sensitive on-site mycotoxin detection, suitable for practical application in various settings due to its sensitivity, accuracy, simplicity, and portability.


Assuntos
Técnicas Biossensoriais , Grão Comestível , Contaminação de Alimentos , Limite de Detecção , Microesferas , Micotoxinas , Zearalenona , Micotoxinas/análise , Grão Comestível/química , Grão Comestível/microbiologia , Técnicas Biossensoriais/métodos , Contaminação de Alimentos/análise , Zearalenona/análise , Cromatografia de Afinidade/métodos , Cromatografia de Afinidade/instrumentação , Aflatoxina B1/análise , Aflatoxina B1/isolamento & purificação , Tricotecenos/análise , Fitas Reagentes/análise , Imunoensaio/métodos , Imunoensaio/instrumentação , Corantes Fluorescentes/química
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 317: 124424, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733917

RESUMO

A new peptide-based fluorescent probe named DMDH with easy-to-synthesize, excellent stability, good water solubility and large Stokes shift (225 nm) was synthesized for highly selective sequential detections of copper ions (Cu2+) and glyphosate (Glyp). DMDH demonstrated great detection performance towards Cu2+via strong fluorescence quenching, and forming non-fluorescence DMDH-Cu2+ ensemble. As a new promising cascade probe, the fluorescence of DMDH-Cu2+ ensemble was significantly recovered based on displacement approach after glyphosate was added. Interestingly, the limit of detections (LODs) for Cu2+ and glyphosate were 40.6 nM and 10.6 nM, respectively, which were far lower than those recommended by the WHO guidelines for drinking water. More importantly, DMDH was utilized to evaluate Cu2+ and glyphosate content in three real water samples, demonstrating that its effectiveness in water quality monitoring. Additionally, it is worth noting that DMDH was also applied to analyze Cu2+ and glyphosate in living cells in view of significant cells permeability and low cytotoxicity. Moreover, DMDH soaked in filter paper was used to create qualitative test strips and visually identify Cu2+ and glyphosate through significant color changes. Furthermore, smartphone RGB color recognition provided a new method for semi-quantitative testing of Cu2+ and glyphosate in the absence of expensive instruments.


Assuntos
Cobre , Corantes Fluorescentes , Glicina , Glifosato , Peptídeos , Smartphone , Espectrometria de Fluorescência , Cobre/análise , Cobre/química , Glicina/análogos & derivados , Glicina/análise , Glicina/química , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Humanos , Espectrometria de Fluorescência/métodos , Peptídeos/química , Limite de Detecção , Fitas Reagentes/análise , Poluentes Químicos da Água/análise , Células HeLa , Água Potável/análise
6.
Talanta ; 275: 126181, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692047

RESUMO

The detection of biomarkers is of great significance for medical diagnosis, food safety, environmental monitoring, and agriculture. However, bio-detection technology at present often necessitates complex instruments, expensive reagents, specialized expertise, and prolonged procedures, making it challenging to fulfill the demand for rapid, sensitive, user-friendly, and economical testing. In contrast, lateral flow strip (LFS) technology offers simple, fast, and visually accessible detection modality, allowing real-time analysis of clinical specimens, thus finding widespread utility across various domains. Within the realm of LFS, the application of aptamers as molecular recognition probes presents distinct advantages over antibodies, including cost-effectiveness, smaller size, ease of synthesis, and chemical stability. In recent years, aptamer-based LFS has found extensive application in qualitative, semi-quantitative, and quantitative detection across food safety, environmental surveillance, clinical diagnostics, and other domains. This review provided a concise overview of different aptamer screening methodologies, selection strategies, underlying principles, and procedural, elucidating their respective advantages, limitations, and applications. Additionally, we summarized recent strategies and mechanisms for aptamer-based LFS, such as the sandwich and competitive methods. Furthermore, we classified LFSs constructed based on aptamers, considering the rapid advancements in this area, and discussed their applications in biological and chemical detection. Finally, we delved into the current challenges and future directions in the development of aptamer and aptamer-based LFS. Although this review was not thoroughly, it would serve as a valuable reference for understanding the research progress of aptamer-based LFS and aid in the development of new types of aptasensors.


Assuntos
Aptâmeros de Nucleotídeos , Aptâmeros de Nucleotídeos/química , Humanos , Técnicas Biossensoriais/métodos , Fitas Reagentes/química , Técnica de Seleção de Aptâmeros/métodos , Biomarcadores/análise
7.
Mikrochim Acta ; 191(6): 311, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38717575

RESUMO

Urine retinol-binding protein 4 (RBP4) has recently been reported as a novel earlier biomarker of chronic kidney disease (CKD) which is a global public health problem with high morbidity and mortality. Accurate and rapid detection of urine RBP4 is essential for early monitor of impaired kidney function and prevention of CKD progression. In the present study, we developed a time-resolved fluorescence immunochromatographic test strip (TRFIS) for the quantitative and rapid detection of urine RBP4. This TRFIS possessed excellent linearity ranging from 0.024 to 12.50 ng/mL for the detection of urine RBP4, and displayed a good linearity (Y = 239,581 × X + 617,238, R2 = 0.9902), with the lowest visual detection limit of 0.049 ng/mL. This TRFIS allows for quantitative detection of urine RBP4 within 15 min and shows high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 8%, respectively. Additionally, this TRFIS was applied to detect RBP4 in the urine samples from healthy donors and patients with CKD, and the results of TRFIS could efficiently discern the patients with CKD from the healthy donors. The developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range, and is suitable for rapid and quantitative determination of urine RBP4.


Assuntos
Cromatografia de Afinidade , Insuficiência Renal Crônica , Proteínas Plasmáticas de Ligação ao Retinol , Humanos , Proteínas Plasmáticas de Ligação ao Retinol/urina , Cromatografia de Afinidade/métodos , Insuficiência Renal Crônica/urina , Insuficiência Renal Crônica/diagnóstico , Limite de Detecção , Fitas Reagentes , Biomarcadores/urina , Imunoensaio/métodos
8.
Mikrochim Acta ; 191(6): 325, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38739279

RESUMO

Glial fibrillary acidic protein (GFAP) in serum has been shown as a biomarker of traumatic brain injury (TBI) which is a significant global public health concern. Accurate and rapid detection of serum GFAP is critical for TBI diagnosis. In this study, a time-resolved fluorescence immunochromatographic test strip (TRFIS) was proposed for the quantitative detection of serum GFAP. This TRFIS possessed excellent linearity ranging from 0.05 to 2.5 ng/mL for the detection of serum GFAP and displayed good linearity (Y = 598723X + 797198, R2 = 0.99), with the lowest detection limit of 16 pg/mL. This TRFIS allowed for quantitative detection of serum GFAP within 15 min and showed high specificity. The intra-batch coefficient of variation (CV) and the inter-batch CV were both < 4.0%. Additionally, this TRFIS was applied to detect GFAP in the serum samples from healthy donors and patients with cerebral hemorrhage, and the results of TRFIS could efficiently discern the patients with cerebral hemorrhage from the healthy donors. Our developed TRFIS has the characteristics of high sensitivity, high accuracy, and a wide linear range and is suitable for rapid and quantitative determination of serum GFAP on-site.


Assuntos
Cromatografia de Afinidade , Proteína Glial Fibrilar Ácida , Humanos , Biomarcadores/sangue , Hemorragia Cerebral/sangue , Hemorragia Cerebral/diagnóstico , Cromatografia de Afinidade/métodos , Proteína Glial Fibrilar Ácida/sangue , Limite de Detecção , Fitas Reagentes
9.
Anal Methods ; 16(16): 2456-2463, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38591267

RESUMO

An elevated level of homocysteine (Hcy) in serum is closely related to the development of various diseases. Therefore, homocysteine has been widely employed as a biomarker in medical diagnosis and the on-site detection of homocysteine is highly desired. In this study, a truncated highly specific aptamer for homocysteine was screened and used to design a lateral flow strip (LFS) for the detection of homocysteine. The aptamer was derived from a previously reported sequence. Based on the result of molecular docking, the original sequence was subjected to truncation, resulting in a reduction of the length from 66 nt to 55 nt. Based on the truncated aptamer, the LFS was designed for the detection of homocysteine. In the presence of homocysteine, the aptamer selectively binds to it, releasing cDNA from the aptamer/cDNA duplex. This allows cDNA to bind to the capture probe immobilized on the T zone of the strip, resulting in a red signal on the T zone from gold nanoparticles (AuNPs). The strip enables the visual detection of homocysteine in 5 min. Quantitative detection can be facilitated with the aid of ImageJ software. In this mode, the linear detection range for homocysteine is within 5-50 µM, with a detection limit of 4.18 µM. The strip has been effectively utilized for the detection of homocysteine in human serum. Consequently, the combination of the truncated aptamer and the strip offers a method that is sensitive, quick, and economical for the on-site detection of homocysteine.


Assuntos
Aptâmeros de Nucleotídeos , Ouro , Homocisteína , Nanopartículas Metálicas , Homocisteína/sangue , Homocisteína/química , Homocisteína/análise , Aptâmeros de Nucleotídeos/química , Humanos , Ouro/química , Nanopartículas Metálicas/química , Limite de Detecção , Técnicas Biossensoriais/métodos , Fitas Reagentes/química , Simulação de Acoplamento Molecular
10.
Analyst ; 149(9): 2747-2755, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38563739

RESUMO

Avian leukemia is an infectious tumorous disease of chickens caused by subgroup A of the avian leukemia virus (ALV-A), which mainly causes long-term viremia, slow growth, immune suppression, decreased production performance, multi-tissue tumors, and even death. The infection rate of this disease is very high in chicken herds in China, causing huge economic losses to the poultry industry every year. We successfully expressed the specific antigen protein of ALV (P27) through recombinant protein technology and screened a pair of highly sensitive monoclonal antibodies (mAbs) through mouse immunity, cell fusion, and antibody pairing. Based on this pair of antibodies, we established a dual antibody sandwich ELISA and gold nanoparticle immunochromatographic strip (AuNP-ICS) detection method. In addition, the parameters of the dual antibody sandwich ELISA and AuNP-ICS were optimized under different reaction conditions, which resulted in the minimum detection limits of 0.2 ng mL-1 and 1.53 ng ml-1, respectively. Commonly available ELISA and AuNP-ICS products on the market were compared, and we found that our established immune rapid chromatography had higher sensitivity. This established AuNP-ICS had no cross-reactivity with Influenza A (H1N1), Influenza A (H9N2), respiratory syncytial virus (RSV), varicella-zoster virus (VZV), Listeria monocytogenes listeriolysin (LLO), and Staphylococcal enterotoxin SED or SEC. Finally, the established AuNP-ICS was used to analyze 35 egg samples, and the results showed 5 positive samples and 30 negative samples. The AuNP-ICS rapid detection method established by our group had good specificity, high sensitivity, and convenience, and could be applied to the clinical sample detection of ALV-A.


Assuntos
Vírus da Leucose Aviária , Cromatografia de Afinidade , Ensaio de Imunoadsorção Enzimática , Ouro , Nanopartículas Metálicas , Ouro/química , Nanopartículas Metálicas/química , Animais , Vírus da Leucose Aviária/isolamento & purificação , Vírus da Leucose Aviária/imunologia , Cromatografia de Afinidade/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Antígenos Virais/imunologia , Antígenos Virais/análise , Clara de Ovo/química , Fitas Reagentes , Galinhas , Limite de Detecção , Camundongos , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/química
11.
Molecules ; 29(8)2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38675595

RESUMO

The COVID-19 pandemic over recent years has shown a great need for the rapid, low-cost, and on-site detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this study, an aptamer-based colloidal gold nanoparticle lateral flow test strip was well developed to realize the visual detection of wild-type SARS-CoV-2 spike proteins (SPs) and multiple variants. Under the optimal reaction conditions, a low detection limit of SARS-CoV-2 S proteins of 0.68 nM was acquired, and the actual detection recovery was 83.3% to 108.8% for real-world samples. This suggests a potential tool for the prompt detection of SARS-CoV-2 with good sensitivity and accuracy, and a new method for the development of alternative antibody test strips for the detection of other viral targets.


Assuntos
Aptâmeros de Nucleotídeos , COVID-19 , Ouro , Nanopartículas Metálicas , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Humanos , Aptâmeros de Nucleotídeos/química , COVID-19/diagnóstico , COVID-19/virologia , Ouro/química , Limite de Detecção , Nanopartículas Metálicas/química , Fitas Reagentes , SARS-CoV-2/química , Glicoproteína da Espícula de Coronavírus/química
12.
Poult Sci ; 103(6): 103648, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38574460

RESUMO

Avian infectious bronchitis virus (IBV) still causes serious economic losses in the poultry industry. Currently, there are multiple prevalent genotypes and serotypes of IBVs. It is imperative to develop a new diagnosis method that is fast, sensitive, specific, simple, and broad-spectrum. A monoclonal hybridoma cell, N2D5, against the IBV N protein was obtained after fusion of myeloma SP2/0 cells with spleen cells isolated from the immunized Balb/c mice. The N2D5 monoclonal antibody (mAb) and the previously prepared mouse polyclonal antibody against the IBV N protein were used to target IBV as a colloidal gold-mAb conjugate and a captured antibody, respectively, in order to develop an immunochromatographic strip. The optimal pH and minimum antibody concentration in the reaction system for colloidal gold-mAb N2D5 conjugation were pH 6.5 and 30 µg/mL, respectively. Common avian pathogens were tested to evaluate the specificity of the strip and no cross-reaction was observed. The sensitivity of the strip for detecting IBV was 10-1.4522 EID50/mL. The strip showed a broad-spectrum cross-reactive capacity for detecting IBV antigens, including multiple IBV genotypes in China and all of the seven serotypes of IBV that are currently prevalent in southern China. Additionally, the result can be observed within 2 min without any equipment. The throat and cloacal swab samples of chickens that were artificially infected with three IBV strains were tested using the developed strip and the qPCR method; the strip test demonstrated a high consistency in detecting IBV via qPCR gene detection. In conclusion, the immunochromatographic strip that was established is rapid, sensitive, specific, simple, practical, and broad-spectrum; additionally, it has the potential to serve as an on-site rapid detection method of IBV and can facilitate the surveillance and control of the disease, especially in resource-limited areas.


Assuntos
Anticorpos Monoclonais , Galinhas , Infecções por Coronavirus , Coloide de Ouro , Vírus da Bronquite Infecciosa , Camundongos Endogâmicos BALB C , Doenças das Aves Domésticas , Vírus da Bronquite Infecciosa/isolamento & purificação , Vírus da Bronquite Infecciosa/imunologia , Animais , Coloide de Ouro/química , Doenças das Aves Domésticas/diagnóstico , Doenças das Aves Domésticas/virologia , Infecções por Coronavirus/veterinária , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/virologia , Anticorpos Monoclonais/imunologia , Cromatografia de Afinidade/veterinária , Cromatografia de Afinidade/métodos , Camundongos , Sensibilidade e Especificidade , Fitas Reagentes
13.
Lancet Microbe ; 5(4): e366-e378, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38467130

RESUMO

BACKGROUND: Accurate diagnosis is pivotal for implementing strategies for surveillance, control, and elimination of schistosomiasis. Despite their low sensitivity in low-endemicity areas, microscopy-based urine filtration and the Kato-Katz technique are considered as reference diagnostic tests for Schistosoma haematobium and Schistosoma mansoni infections, respectively. We aimed to collate all available evidence on the accuracy of other proposed diagnostic techniques. METHODS: In this systematic review and meta-analysis, we searched PubMed, Embase, the Cochrane Library, and LILACS for studies published from database inception to Dec 31, 2022, investigating the sensitivity and specificity of diagnostic tests for S haematobium and S mansoni infections against Kato-Katz thick smears or urine microscopy (reference tests) involving adults (aged ≥18 years), school-aged children (aged 7 to 18 years), or preschool-aged children (aged 1 month to 7 years). We extracted raw data on true positives, true negatives, false positives, and false negatives for the diagnostic tests and data on the number of participants, study authors, publication year, journal, study design, participants' age and sex, prevalence of Schistosoma infection, and treatment status. To account for imperfect reference tests, we used a hierarchical Bayesian latent class meta-analysis to model test accuracy. FINDINGS: Overall, we included 121 studies, assessing 28 different diagnostic techniques. Most studies (103 [85%] of 121) were done in Africa, 14 (12%) in South America, one (1%) in Asia, and one (1%) in an unknown country. Compared with the reference test, Kato-Katz thick smears, circulating cathodic antigen urine cassette assay version 1 (CCA1, 36 test comparisons) had excellent sensitivity (95% [95% credible interval 88-99]) and reasonable specificity (74% [63-83]) for S mansoni. ELISA-based tests had a performance comparable to circulating cathodic antigen, but there were few available test comparisons. For S haematobium, proteinuria (42 test comparisons, sensitivity 73% [62-82]; specificity 94% [89-98]) and haematuria (75 test comparisons, sensitivity 85% [80-90]; specificity 96% [92-99]) reagent strips showed high specificity, with haematuria reagent strips having better sensitivity. Despite limited data, nucleic acid amplification tests (NAATs; eg, PCR or loop-mediated isothermal amplification [LAMP]) showed promising results with sensitivity estimates above 90%. We found an unclear risk of bias of about 70% in the use of the reference or index tests and of 50% in patient selection. All analyses showed substantial heterogeneity (I2>80%). INTERPRETATION: Although NAATs and immunological diagnostics show promise, the limited information available precludes drawing definitive conclusions. Additional research on diagnostic accuracy and cost-effectiveness is needed before the replacement of conventional tests can be considered. FUNDING: WHO and Luxembourg Institute of Health.


Assuntos
Schistosoma mansoni , Esquistossomose Urinária , Criança , Pré-Escolar , Adulto , Animais , Humanos , Adolescente , Schistosoma haematobium , Hematúria/diagnóstico , Fitas Reagentes , Microscopia , Teorema de Bayes , Fezes , Antígenos de Helmintos/urina , Urinálise , Esquistossomose Urinária/diagnóstico , Testes Diagnósticos de Rotina/métodos
14.
J Pharm Biomed Anal ; 242: 115976, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38350371

RESUMO

Lung cancer is the most common malignancy worldwide. Early diagnosis helps to reduce mortality and improve survival. Aptamers are widely used in cancer screening because of their high specificity, good stability and low cost. In this study, using the specific aptamer of lung cancer serum, the sandwich method colloidal gold test strip was prepared by isothermal amplification technique and the principle of nucleic acid hybridisation for the early diagnosis of lung cancer. The results showed that the test strip was positive in 8 patients with lung cancer, which was consistent with the actual cases. The test strip can accurately identify lung cancer patients. The concentration range of nucleic acid detection is 1 × 10-4 - 7 × 10-4 mol/L, and the detection limit is 0.67 mM. The test strip detection method has low cost and simple operation, and provides a reference for the development of home portable tumor early detection.


Assuntos
Aptâmeros de Nucleotídeos , Neoplasias Pulmonares , Ácidos Nucleicos , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Detecção Precoce de Câncer , Hibridização de Ácido Nucleico , Fitas Reagentes
15.
Methods ; 224: 63-70, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38367653

RESUMO

Urinalysis is a useful test as an indicator of health or disease and as such, is a part of routine health screening. Urinalysis can be undertaken in many ways, one of which is reagent strips used in the general evaluation of health and to aid in the diagnosis and monitoring of kidney disease. To be effective, the test must be performed properly, and the results interpreted correctly. However, different light conditions and colour perception can vary between users leading to ambiguous readings. This has led to camera devices being used to capture and generate the estimated biomarker concentrations, but image colour can be affected by variations in illumination and inbuilt image processing. Therefore, a new portable device with embedded image processing techniques is presented in this study to provide quantitative measurements that are invariant to changes in illumination. The device includes a novel calibration process and uses the ratio of RGB values to compensate for variations in illumination across an image and improve the accuracy of quantitative measurements. Results show that the proposed calibration method gives consistent homogeneous illumination across the whole image. Comparisons against other existing methods and clinical results show good performance with a correlation to the clinical values. The proposed device can be used for point-of-care testing to provide reliable results consistent with clinical values.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Fitas Reagentes , Urinálise/métodos , Processamento de Imagem Assistida por Computador
17.
Cornea ; 43(5): 635-640, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38015937

RESUMO

PURPOSE: Schirmer test results are widely used for ocular surface disease assessment, but Schirmer strips are not standardized. We compare the characteristics and tear volume with millimeter moisture migration in different brands of Schirmer strips and introduce methods for volume-based, brand-independent calibration. METHODS: Physical parameters of Haag-Streit, EagleVision, TearFlo, Contacare, and MIPL/A6 Schirmer strip brands were compared. Schirmer strip millimeter moisture migration distances were assessed 5 minutes after application of incremental microliter volumes of human tears. Linear regression analysis of data points from each Schirmer strip brand was performed, and the root-mean-square deviation of data points to the best-fit linear regression was calculated. Calibration correction was performed by converting migration distance to the corresponding tear volume. A reference table and calibration method formulas were created. RESULTS: Schirmer strips differed in design, shape, and manufacturing precision. Strip width, weight, and length were different between the 5 brands ( P < 0.05). A wide range of Schirmer strip moisture migration values for identical tear volumes was observed among brands. Statistical measurement resulted in a root-mean-square deviation of 2.9 mm for all data points from all brands. Millimeter to volume and weight to volume-based calibration correction methods resulted in a 2.2- and 3.1-fold measurement error reduction, respectively. CONCLUSIONS: Our findings highlight the lack of standardization among different brands of Schirmer strips, raising concerns about potential sources of unintentional measurement errors. We propose volume-based Schirmer strip calibration methods and conversion of millimeter to microliter results to achieve brand-independent results and improve Schirmer test accuracy.


Assuntos
Lacerações , Fitas Reagentes , Humanos , Calibragem , Lágrimas , Padrões de Referência
18.
Arch Pathol Lab Med ; 148(4): e69-e74, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37852173

RESUMO

CONTEXT.­: Urinalysis instrument-specific dip strips offer physicians qualitative results for actionable analytes (protein, glucose, leukocyte esterase, nitrates, hemoglobin, and ketones). OBJECTIVE.­: To explain a strategy implemented to support clinical decision-making by providing urine quantification of protein, glucose, white blood cells (WBCs), and red blood cells because of urine strip shortages. DESIGN.­: During shortages, we implemented an automated algorithm that triggered sending urine samples to the automation line for quantification of protein and glucose and ensured that urine microscopy was performed to obtain WBC and red blood cell counts. The algorithm printed 2 labels so nursing staff would collect 2 specimens. We monitored the turnaround time from the specimen being received in the laboratory to result verification, ensured that the culture reflex order was triggered, and tracked complaints by physicians regarding not having usual urinalysis results. Prior to implementation, correlation between sample types for protein and glucose measurement was found acceptable. RESULTS.­: The algorithm was put in place twice during 2022. The turnaround time of urine microscopic study was identical to that obtained when the urinalysis was done with the strips; however, the quantification of glucose and protein took approximately 30 minutes more. Urine reflex cultures were triggered correctly with the algorithm, as they were derived entirely from a WBC count higher than 10 per high-power field. During the shortage period we had only 1 complaint, by a physician wanting to have results of nitrates. CONCLUSIONS.­: During urine strip shortages, we successfully implemented a diversion algorithm that provided actionable urinalysis analytes in a timely manner with minimal provider complaints.


Assuntos
Microscopia , Urinálise , Humanos , Urinálise/métodos , Hemoglobinas , Glucose , Nitratos , Fitas Reagentes , Contagem de Leucócitos
19.
Stud Health Technol Inform ; 308: 168-178, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38007738

RESUMO

In this study, monoclonal antibodies against oxamyl were prepared, and colloidal gold immunochromatography was used to design a rapid test strip product for the detection of oxamyl in tobacco with high specificity, accuracy and stability without cross-reactivity to commonly used tobacco fungicides based on the optimization of conditions such as pH value of diluent, diluent dosage, concentration of antibody marker, type of confining solution and complex solution. 5 The results of five samples of post-harvest ready-to-bake tobacco and first-harvest tobacco were consistent with the gas chromatographic method, which proved the reliability of the test strips. The limits of detection for the post-harvest and first-harvest tobacco samples were 0.1 mg/kg, and the test strips developed in this study are suitable for mass testing in tobacco laboratories with good application prospects because of their short detection time, simple pre-treatment and detection methods.


Assuntos
Nicotiana , Fitas Reagentes , Fitas Reagentes/análise , Reprodutibilidade dos Testes , Coloide de Ouro/química , Sensibilidade e Especificidade
20.
Stud Health Technol Inform ; 308: 179-190, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38007739

RESUMO

The rapid and accurate determination of triadimenol residues is of great significance. In this study, based on the advantages of high efficiency, rapidity, reliability, simplicity and low cost of immunology, a test strip product for the rapid detection of triadimenol residues in tobacco was designed based on the optimization of conditions such as pH and dosage of diluent, concentration of antibody stock solution, type of confining solution and complex solution, with high specificity, accuracy and The results of 20 samples of fresh and first roasted tobacco were all consistent with the method of gas chromatography, which proved the reliability of the test strips. The detection limit for fresh and roasted tobacco was 5 mg/kg, and the test strips developed in this study are suitable for mass testing of tobacco samples in tobacco-related laboratories because of their short detection time, simple pre-treatment and detection methods, and good application prospects.


Assuntos
Nicotiana , Fitas Reagentes , Fitas Reagentes/análise , Reprodutibilidade dos Testes , Coloide de Ouro/química , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...