Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.610
Filtrar
1.
Science ; 385(6713): eadm6869, 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39236186

RESUMO

Optical imaging plays a central role in biology and medicine but is hindered by light scattering in live tissue. We report the counterintuitive observation that strongly absorbing molecules can achieve optical transparency in live animals. We explored the physics behind this observation and found that when strongly absorbing molecules dissolve in water, they can modify the refractive index of the aqueous medium through the Kramers-Kronig relations to match that of high-index tissue components such as lipids. We have demonstrated that our straightforward approach can reversibly render a live mouse body transparent to allow visualization of a wide range of deep-seated structures and activities. This work suggests that the search for high-performance optical clearing agents should focus on strongly absorbing molecules.


Assuntos
Imagem Óptica , Animais , Camundongos , Luz , Imagem Óptica/métodos , Refratometria , Espalhamento de Radiação , Água/química , Pele , Músculos
2.
Sensors (Basel) ; 24(15)2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39124105

RESUMO

This paper presents a new biosensor design based on the Kretschmann configuration, for the detection of analytes at different refractive indices. Our studied design consists of a TiO2/SiO2 bi-layer sandwiched between a BK7 prism and a bimetallic layer of Ag/Au plasmonic materials, covered by a layer of black phosphorus placed below the analyte-containing detection medium. The different layers of our structure and analyte detection were optimized using the angular interrogation method. High performance was achieved, with a sensitivity of 240 deg/RIU and a quality factor of 34.7 RIU-1. This biosensor can detect analytes with a wide refractive index range between 1.330 and 1.347, such as glucose detection in urine samples using a refractive index variation of 10-3. This capability offers a wide range of applications for biomedical and biochemical detection and selectivity.


Assuntos
Técnicas Biossensoriais , Glucose , Fósforo , Titânio , Fósforo/química , Técnicas Biossensoriais/métodos , Glucose/análise , Glucose/química , Humanos , Titânio/química , Prata/química , Ouro/química , Dióxido de Silício/química , Refratometria
3.
BMC Res Notes ; 17(1): 234, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39180094

RESUMO

OBJECTIVES: The biuret method is frequently used to determine serum total protein. On the other hand refractometer, a quicker and less expensive option, is available to determine serum total protein. However, there is no study conducted in Ethiopia to compare serum total protein measurement in veterinary settings. Therefore, this study was conducted to compare the serum total protein concentration measurement in cattle and goats obtained by the biuret method and refractometer. RESULTS: Serum samples from 60 cattle and 60 goats were assayed by both methods and data were analyzed with a paired t-test, Pearson's correlation, and Bland-Altman plots. There was a strong positive correlation between the total protein values determined with the refractometer and the biuret method in cattle (r = 0.93) and goats (r = 0.97). There were no significant differences (p > 0.05) in the protein values measured with the refractometer and those evaluated with the biuret method in both species. Bland-Altman plots showed that biases indicating the analytic and user error were 8.33% in both species which is below the acceptable total error (< 10%). Thus, refractometer can be used in place of biuret method since it is valid enough to measure serum total protein in cattle and goats.


Assuntos
Proteínas Sanguíneas , Cabras , Refratometria , Animais , Cabras/sangue , Bovinos/sangue , Refratometria/métodos , Proteínas Sanguíneas/análise , Etiópia
4.
J Biomed Opt ; 29(8): 080502, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39206121

RESUMO

Significance: Azimuth-resolved optical scattering signals obtained from cell nuclei are sensitive to changes in their internal refractive index profile. These two-dimensional signals can therefore offer significant insights into chromatin organization. Aim: We aim to determine whether two-dimensional scattering signals can be used in an inverse scheme to extract the spatial correlation length ℓ c and extent δ n of subnuclear refractive index fluctuations to provide quantitative information on chromatin distribution. Approach: Since an analytical formulation that links azimuth-resolved signals to ℓ c and δ n is not feasible, we set out to assess the potential of machine learning to predict these parameters via a data-driven approach. We carry out a convolutional neural network (CNN)-based regression analysis on 198 numerically computed signals for nuclear models constructed with ℓ c varying in steps of 0.1 µ m between 0.4 and 1.0 µ m , and δ n varying in steps of 0.005 between 0.005 and 0.035. We quantify the performance of our analysis using a five-fold cross-validation technique. Results: The results show agreement between the true and predicted values for both ℓ c and δ n , with mean absolute percent errors of 8.5% and 13.5%, respectively. These errors are smaller than the minimum percent increment between successive values for respective parameters characterizing the constructed models and thus signify an extremely good prediction performance over the range of interest. Conclusions: Our results reveal that CNN-based regression can be a powerful approach for exploiting the information content of two-dimensional optical scattering signals and hence monitoring chromatin organization in a quantitative manner.


Assuntos
Núcleo Celular , Cromatina , Redes Neurais de Computação , Cromatina/química , Núcleo Celular/química , Análise de Regressão , Espalhamento de Radiação , Refratometria/métodos , Aprendizado de Máquina , Humanos , Algoritmos
5.
Biomed Phys Eng Express ; 10(5)2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39142302

RESUMO

The article presents, for the first time, a terahertz metamaterial absorber (TMA) designed in the shape of a cross consisting of four orthogonally positioned horn-shaped patches in succession, to detect brain cancer cells. The design exhibits the property of mu-negative material, indicating magnetic resonance. The proposed TMA has achieved an impressive absorption rate of 99.43% at 2.334 THz and a high Q-factor of 47.15. The sensing capability has been investigated by altering the refractive index of the surrounding medium in the range of 1.3 to 1.48, resulting in a sensitivity of 0.502 THz/RIU. The proposed TMA exhibits complete polarization insensitivity, highlighting this as one of its advantageous features. The adequate sensing capability of the proposed TMA in differentiating normal and cancerous brain cells makes it a viable candidate for an early and efficient brain cancer detector. This research can be the foundation for future research on using THz radiation for brain cancer detection.


Assuntos
Neoplasias Encefálicas , Radiação Terahertz , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Refratometria/métodos , Encéfalo/diagnóstico por imagem , Desenho de Equipamento
6.
Biomacromolecules ; 25(9): 6155-6163, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39110195

RESUMO

A series of polymers with both high refractive index and high Abbe number have been successfully synthesized through the photoclick thiol-ene reaction between the monomers derived from biobased magnolol (or honokiol) and commercial mercaptans and thiophenols. The polymer films not only exhibit a high refractive index and a high Abbe number but also display a transmittance of up to 90% in a range of wavelengths from 550 to 2000 nm and nearly 0% in the UV region. Moreover, these polymers also display low haze values in the visible-light region as well as exhibit good thermostability. These data indicate that they have potential applications for the fabrication of optical lenses and anti-UV coatings. In particular, this series of polymers are readily used for industrialization due to its excellent optical properties but low expense, simplicity, and efficiency of synthesis.


Assuntos
Compostos de Bifenilo , Lignanas , Lignanas/química , Compostos de Bifenilo/química , Polímeros/química , Refratometria , Compostos Alílicos , Fenóis
7.
Forensic Sci Int ; 361: 112124, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38971140

RESUMO

Latent fingerprints (LFPs) are predominantly used for personal identification, but in recent years research has shown their potential for drug screening. Despite this there is no standardised collection method to allow accurate drug test interpretation. We sought to help address this by characterising different variables related to sweat deposition in LFPs as the knowledge is limited. A series of experiments were conducted firstly to validate a novel tool called the Ridgeway (Intelligent Fingerprint Ltd. UK) to quantify the amount of sweat deposited from a LFP using the refractive index (RI). A significant positive correlation was observed between the Ridgeway score (Rs) and LFP mass [r = 0.868, p < 0.01]. The Rs was used as means to investigate optimal sampling to characterise sample deposition for drug screening purposes. It was found with a consistent disposition pressure (300 - 400 g) and surface (glass slide) no significant difference was observed between the left and right index finger [left: p = 0.938; right: p = 0.838]. Significantly higher Rs [p<0.01] were obtained when 10 cumulative LFPs were deposited compared to a single LFP, suggesting a larger sweat quantity. We also wanted to investigate optimal eccrine sweat sampling to confirm drug ingestion over drug contamination of the fingerprint. We found that wearing gloves did not significantly improve mean difference in Rs when compared to no gloves [p = 0.239]. To produce eccrine only LFPs, external contamination (e.g. sebaceous sweat) needs to be removed. Soap with lint free tissue was significantly better for this compared to antibacterial hand gel [p<0.01]. Our findings showed that the Ridgeway tool effectively quantified LFPs at the point of deposition using a refractive index and enabled us to establish conditions for consistent LFP sampling.


Assuntos
Dermatoglifia , Refratometria , Suor , Humanos , Suor/química , Masculino , Feminino , Adulto , Glândulas Écrinas , Detecção do Abuso de Substâncias/métodos , Luvas Protetoras
8.
J Pharm Sci ; 113(9): 2817-2825, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39032825

RESUMO

The characteristics of subvisible particles (SbVPs) are critical quality attributes of injectable and ophthalmic solutions in pharmaceutical manufacturing. However, current compendial SbVP testing methods, namely the light obstruction method and the microscopic particle count method, are destructive and wasteful of target samples. In this study, we present the development of a non-destructive SbVP analyzer aiming to analyze SbVPs directly in drug product (DP) containers while keeping the samples intact. Custom sample housings are developed and incorporated into the analyzer to reduce optical aberrations introduced by the curvature of typical pharmaceutical DP sample containers. The analyzer integrates a light-sheet microscope structure and models the side scattering event from a particle with Mie scattering theory with refractive indices as prior information. Equivalent spherical particle size under assigned refractive index values is estimated, and the particle concentration is determined based on the number of scattering events and the volume sampled by the light sheet. The resulting analyzer's capability and performance to non-destructively analyze SbVPs in DP containers were evaluated using a series of polystyrene bead suspensions in ISO 2R and 6R vials. Our results and analysis show the particle analyzer is capable of directly detecting SbVPs from intact DP containers, sorting SbVPs into commonly used size bins (e.g. ≥ 2 µm, ≥ 5 µm, ≥ 10 µm, and ≥ 25 µm), and reliably quantifying SbVPs in the concentration range of 4.6e2 to 5.0e5 particle/mL with a margin of ± 15 % error based on a 90 % confidence interval.


Assuntos
Tamanho da Partícula , Espalhamento de Radiação , Luz , Refratometria/métodos , Tecnologia Farmacêutica/métodos , Embalagem de Medicamentos/métodos , Poliestirenos/química
9.
Molecules ; 29(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38930876

RESUMO

In this study, we report the successful development of a novel high-sensitivity intensity-based Surface Plasmon Resonance imaging (SPRi) biosensor and its application for detecting molecular interactions. By optimizing the excitation wavelength and employing a wavelength division multiplexing (WDM) algorithm, the system can determine the optimal excitation wavelength based on the initial refractive index of the sample without adjusting the incidence angle. The experimental results demonstrate that the refractive index resolution of the system reaches 1.77×10-6 RIU. Moreover, it can obtain the optimal excitation wavelength for samples with an initial refractive index in the range of 1.333 to 1.370 RIU and accurately monitor variations within the range of 0.0037 RIU without adjusting the incidence angle. Additionally, our new SPRi technique realized real-time detection of high-throughput biomolecular binding processes, enabling analysis of kinetic parameters. This research is expected to advance the development of more accurate SPRi technologies for molecular interaction analysis.


Assuntos
Técnicas Biossensoriais , Ressonância de Plasmônio de Superfície , Ressonância de Plasmônio de Superfície/métodos , Técnicas Biossensoriais/métodos , Algoritmos , Refratometria , Ensaios de Triagem em Larga Escala/métodos , Cinética
10.
Opt Express ; 32(11): 20194-20206, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38859135

RESUMO

In this work, a common-path optical coherence tomography (OCT) system is demonstrated for characterizing the tissue in terms of some optical properties. A negative axicon structure chemically etched inside the fiber tip is employed as optical probe in the OCT. This probe generates a quality Bessel beam owning a large depth-of-field, ∼700 µm and small central spot size, ∼3 µm. The OCT system is probing the sample without using any microscopic lens. For experimental validation, the OCT imaging of chicken tissue has been obtained along with estimation of its refractive index and optical attenuation coefficient. Afterwards, the cancerous tissue is differentiated from the normal tissue based on the OCT imaging, refractive index, and optical attenuation coefficient. The respective tissue samples are collected from the human liver and pancreas. This probe could be a useful tool for endoscopic or minimal-invasive inspection of malignancy inside the tissue either at early-stage or during surgery.


Assuntos
Galinhas , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/instrumentação , Humanos , Animais , Desenho de Equipamento , Fígado/diagnóstico por imagem , Fígado/patologia , Pâncreas/diagnóstico por imagem , Refratometria
11.
ACS Appl Mater Interfaces ; 16(25): 32516-32523, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38867603

RESUMO

Plasmonic metamaterials have opened new avenues in medical diagnostics. However, the transfer of the technology to the markets has been delayed due to multiple challenges. The need of bulky optics for signal reading from nanostructures patterned on submillimeter area limits the miniaturization of the devices. The use of objective-free optics can solve this problem, which necessitates large area patterning of the nanostructures. In this work, we utilize laser interference lithography (LIL) to pattern nanodisc-shaped metamaterial absorber nanoantennas over a large area (4 cm2) within minutes. The introduction of a sacrificial layer during the fabrication process enables an inverted hole profile and a well-controlled liftoff, which ensures perfectly defined uniform nanopatterning almost with no defects. Furthermore, we use a macroscopic reflection probe for optical characterization in the near-IR, including the detection of the binding kinematics of immunologically relevant proteins. We show that the photonic quality of the plasmonic nanoantennas commensurates with electron-beam-lithography-fabricated ones over the whole area. The refractive index sensitivity of the LIL-fabricated metasurface is determined as 685 nm per refractive index unit, which demonstrates ultrasensitive detection. Moreover, the fabricated surfaces can be used multiple times for biosensing without losing their optical quality. The combination of rapid and large area nanofabrication with a simple optical reading not only simplifies the detection process but also makes the biosensors more environmentally friendly and cost-effective. Therefore, the improvements provided in this work will empower researchers and industries for accurate and real-time analysis of biological systems.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Técnicas Biossensoriais/métodos , Nanoestruturas/química , Ressonância de Plasmônio de Superfície , Propriedades de Superfície , Refratometria
12.
Acta Vet Hung ; 72(2): 116-124, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38935432

RESUMO

In this study, we aimed to determine the quality of colostrum in sheep by using Brix refractometer. The research included 100 sheep of Merino X Kivircik crossbred. From each, we collected 15 mL of colostrum samples in falcon tubes within the first 8 h after delivery. Mean colostral IgG level of sheep was 156.68 ± 7.23 g L-1, optical and digital Brix refractometer values (%) were determined as 27.43 ± 0.53 and 27.69 ± 0.60, respectively. Ewes carrying twin lambs produced significantly higher quality colostrum than those carrying single lambs. However, parity did not affect the colostrum quality. Optical and digital Brix values were correlated with gold standard radial immunodiffusion (RID) colostral IgG level (r = 0.70 and r = 0.64, respectively). Also, optical and digital Brix refractometers were found to be highly correlated (r = 0.98, P < 0.001). While the optimal Brix value was 22% for the 50, 60 and 70 g L-1 IgG threshold values (by means of RID as the potential good quality threshold value for ewe colostrum quality), this value was 23% for 80 g L-1. We can conclude that Brix refractometers is a valuable tool for determining ewe colostrum quality. A cut point of 22% Brix for defining good quality colostrum in ewes was most appropriate for our data.


Assuntos
Colostro , Refratometria , Animais , Colostro/química , Ovinos , Refratometria/veterinária , Refratometria/instrumentação , Feminino , Imunoglobulina G/análise , Imunoglobulina G/sangue
13.
J Biophotonics ; 17(8): e202400123, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38925916

RESUMO

Knowledge of the optical parameters of tumors is important for choosing the correct laser treatment parameters. In this paper, optical properties and refraction indices of breast tissue in healthy mice and a 4T1 model mimicking human breast cancer have been measured. A significant decrease in both the scattering and refractive index of tumor tissue has been observed. The change in tissue morphology has induced the change in the slope of the scattering spectrum. Thus, the light penetration depth into tumor has increased by almost 1.5-2 times in the near infrared "optical windows." Raman spectra have shown lower lipid content and higher protein content in tumor. The difference in the optical parameters of the tissues under study makes it possible to reliably differentiate them. The results may be useful for modeling the distribution of laser radiation in healthy tissues and cancers for deriving optimal irradiation conditions in photodynamic therapy.


Assuntos
Fenômenos Ópticos , Análise Espectral Raman , Animais , Camundongos , Feminino , Humanos , Linhagem Celular Tumoral , Refratometria , Neoplasias da Mama/patologia , Neoplasias da Mama/metabolismo , Neoplasias da Mama/radioterapia , Camundongos Endogâmicos BALB C
14.
Biol Pharm Bull ; 47(6): 1163-1171, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38880624

RESUMO

The vital role of bile canaliculus (BC) in liver function is closely related to its morphology. Electron microscopy has contributed to understanding BC morphology; however, its invasiveness limits its use in living specimens. Here, we report non-invasive characterization of BC formation using refractive index (RI) tomography. First, we investigated and characterized the RI distribution of BCs in two-dimensional (2D) cultured HepG2 cells. BCs were identified based on their distinct morphology and functionality, as confirmed using a fluorescence-labeled bile acid analog. The RI distribution of BCs exhibited three common features: (1) luminal spaces with a low RI between adjacent hepatocytes; (2) luminal spaces surrounded by a membranous structure with a high RI; and (3) multiple microvillus structures with a high RI within the lumen. Second, we demonstrated the characterization of BC structures in a three-dimensional (3D) culture model, which is more relevant to the in vivo environment but more difficult to evaluate than 2D cultures. Various BC structures were identified inside HepG2 spheroids with the three features of RI distribution. Third, we conducted comparative analyses and found that the BC lumina of spheroids had higher circularity and lower RI standard deviation than 2D cultures. We also addressed comparison of BC and intracellular lumen-like structures within a HepG2 spheroid, and found that the BC lumina had higher RI and longer perimeter than intracellular lumen-like structures. Our demonstration of the non-destructive, label-free visualization and quantitative characterization of living BC structures will be a basis for various hepatological and pharmaceutical applications.


Assuntos
Canalículos Biliares , Humanos , Células Hep G2 , Refratometria/métodos , Esferoides Celulares/ultraestrutura , Tomografia/métodos , Hepatócitos/ultraestrutura , Técnicas de Cultura de Células
15.
Sensors (Basel) ; 24(11)2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38894226

RESUMO

This study presents a novel label-free approach for characterizing cell death states, eliminating the need for complex molecular labeling that may yield artificial or ambiguous results due to technical limitations in microscope resolution. The proposed holographic tomography technique offers a label-free avenue for capturing precise three-dimensional (3D) refractive index morphologies of cells and directly analyzing cellular parameters like area, height, volume, and nucleus/cytoplasm ratio within the 3D cellular model. We showcase holographic tomography results illustrating various cell death types and elucidate distinctive refractive index correlations with specific cell morphologies complemented by biochemical assays to verify cell death states. These findings hold promise for advancing in situ single cell state identification and diagnosis applications.


Assuntos
Morte Celular , Holografia , Imageamento Tridimensional , Tomografia , Holografia/métodos , Tomografia/métodos , Imageamento Tridimensional/métodos , Humanos , Refratometria/métodos
16.
Sensors (Basel) ; 24(11)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38894440

RESUMO

Quasi-bound state in the continuum (QBIC) can effectively enhance the interaction of terahertz (THz) wave with matter due to the tunable high-Q property, which has a strong potential application in the detection of low-concentration biological samples in the THz band. In this paper, a novel THz metamaterial sensor with a double-chain-separated resonant cavity structure based on QBIC is designed and fabricated. The process of excitation of the QBIC mode is verified and the structural parameters are optimized after considering the ohmic loss by simulations. The simulated refractive index sensitivity of the sensor is up to 544 GHz/RIU, much higher than those of recently reported THz metamaterial sensors. The sensitivity of the proposed metamaterial sensor is confirmed in an experiment by detecting low-concentration lithium citrate (LC) and bovine serum albumin (BSA) solutions. The limits of detection (LoDs) are obtained to be 0.0025 mg/mL (12 µM) for LC and 0.03125 mg/mL (0.47 µM) for BSA, respectively, both of which excel over most of the reported results in previous studies. These results indicate that the proposed THz metamaterial sensor has excellent sensing performances and can well be applied to the detection of low-concentration biological samples.


Assuntos
Técnicas Biossensoriais , Soroalbumina Bovina , Soroalbumina Bovina/química , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Limite de Detecção , Animais , Radiação Terahertz , Bovinos , Espectroscopia Terahertz/métodos , Refratometria , Compostos de Lítio/química , Ácido Cítrico/química
17.
Sci Total Environ ; 935: 173428, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-38777065

RESUMO

The water-soluble polymer polyvinylpyrrolidone (PVP) is an established ingredient in pharmaceutical and personal care product (PPCP) formulations. Due to its high usage and lack of biodegradability, it has been detected up to 7.0 mg L-1 in wastewater and 0.1 mg L-1 in the receiving freshwaters, with several studies showing detrimental sublethal effects in a range of aquatic species. A lack of simple analytical methods to detect and quantify PVP currently impacts further investigation into the cause of these sublethal effects. In this paper we propose a refractive index gel-permeation chromatography (GPC) method to quantify PVP, which includes the processing of raw chromatograms using line deconvolution to calculate peak area. The method was then applied to Daphnia magna exposed to PVP for 48 h. A limit of detection (LOD) and limit of quantification (LOQ) of 0.05 and 0.2 mg mL-1 respectively was determined, with a recovery of 78 % from spiked Daphnia magna. PVP was detected in the samples above the LOD but below the LOQ. This suggests PVP is ingested by Daphnia magna, which warrants further investigation into whether bioaccumulation of PVP could be causing the sublethal effects seen in other studies.


Assuntos
Daphnia magna , Povidona , Poluentes Químicos da Água , Animais , Organismos Aquáticos/efeitos dos fármacos , Daphnia magna/efeitos dos fármacos , Daphnia magna/fisiologia , Monitoramento Ambiental/métodos , Limite de Detecção , Polímeros , Povidona/química , Refratometria , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade
18.
Biophys Rep (N Y) ; 4(2): 100156, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38718671

RESUMO

The quantification of physical properties of biological matter gives rise to novel ways of understanding functional mechanisms. One of the basic biophysical properties is the mass density (MD). It affects the dynamics in sub-cellular compartments and plays a major role in defining the opto-acoustical properties of cells and tissues. As such, the MD can be connected to the refractive index (RI) via the well known Lorentz-Lorenz relation, which takes into account the polarizability of matter. However, computing the MD based on RI measurements poses a challenge, as it requires detailed knowledge of the biochemical composition of the sample. Here we propose a methodology on how to account for assumptions about the biochemical composition of the sample and respective RI measurements. To this aim, we employ the Biot mixing rule of RIs alongside the assumption of volume additivity to find an approximate relation of MD and RI. We use Monte-Carlo simulations and Gaussian propagation of uncertainty to obtain approximate analytical solutions for the respective uncertainties of MD and RI. We validate this approach by applying it to a set of well-characterized complex mixtures given by bovine milk and intralipid emulsion and employ it to estimate the MD of living zebrafish (Danio rerio) larvae trunk tissue. Our results illustrate the importance of implementing this methodology not only for MD estimations but for many other related biophysical problems, such as mechanical measurements using Brillouin microscopy and transient optical coherence elastography.


Assuntos
Refratometria , Peixe-Zebra , Animais , Refratometria/métodos , Bovinos , Leite/química , Método de Monte Carlo , Larva/química
19.
Luminescence ; 39(5): e4759, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38693721

RESUMO

Colloidal semiconductor quantum dots have many potential optical applications, including quantum dot light-emitting diodes, single-photon sources, or biological luminescent markers. The optical properties of colloidal quantum dots can be affected by their dielectric environment. This study investigated the photoluminescence (PL) decay of thick-shell gradient-alloyed colloidal semiconductor quantum dots as a function of solvent refractive index. These measurements were conducted in a wide range of delay times to account for both the initial spontaneous decay of excitons and the delayed emission of excitons that has the form of a power law. It is shown that whereas the initial spontaneous PL decay is very sensitive to the refractive index of the solvent, the power-law delayed emission of excitons is not. Our results seem to exclude the possibility of carrier self-trapping in the considered solvents and suggest the existence of trap states inside the quantum dots. Finally, our data show that the average exciton lifetime significantly decreases as a function of the solvent refractive index. The change in exciton lifetime is qualitatively modeled and discussed.


Assuntos
Coloides , Luminescência , Pontos Quânticos , Solventes , Pontos Quânticos/química , Solventes/química , Coloides/química , Refratometria , Medições Luminescentes , Semicondutores , Fatores de Tempo
20.
PLoS One ; 19(5): e0301007, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38758827

RESUMO

Building on the Fano resonance observation, a new refractive index transducer structure at the nanoscale is proposed in this article, which is a refractive index transducer consisting of a metal-insulator-metal (MIM) waveguide structure coupled with a ring cavity internally connected to an h-shaped structure (RCIhS). Using an analytical method based on COMSOL software and finite element method (FEM), the effect of different geometric parameters of the structure on the trans-mission characteristics of the system is simulated and analyzed, which in turn illustrates the effect of the structural parameters on the output Fano curves. As simulation results show, the internally connected h-shaped structure is an influential component in the Fano resonance. By optimizing the geometrical parameters of the structure, the system finally accomplishes a sensitivity (S) of 2400 nm/RIU and a figure of merit (FOM) of 68.57. The sensor has also been demonstrated in the realm of temperature detection, having tremendous potential for utilization in future nano-sensing and optically integrated systems.


Assuntos
Refratometria , Transdutores , Análise de Elementos Finitos , Desenho de Equipamento , Nanotecnologia , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA