Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.744
Filtrar
1.
Pediatr Dent ; 46(3): 199-203, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38822496

RESUMO

Purpose: The purposes of this in vitro study were to evaluate the effect of three isolation methods to mitigate bioaerosols during stainless steel crown (SSC) preparations and assess the distribution of Streptococcus mutans by aerosolization in closed-room operatories. Methods: Melamine teeth coated in laboratory-grown S. mutans biofilm were prepared for SSCs using three different isolation methods. Agar plates were placed in five locations throughout the operatory and opened during each preparation as well as for 10 minutes immediately following to collect aerosolized S. mutans. Bacterial colonies were counted after incubating plates for 48 hours. Data were analyzed for differences between the isolation method and plate locations. Results: Bacterial colony counts for teeth prepared using high-volume evacuation suction (HVE) with dental dam (DD) isolation were statistically significantly higher than for those prepared using HVE with a DryShield®(DS) and HVE with no isolation at the assistant (A) (P<0.001), operator face shield (FS) (P<0.001), and patient (Pt) (P=0.002) locations. No significant differences were found among isolation methods for parent (Pa) or rear delivery (RD) locations. The location that produced the most bacterial colony counts using HVE with DD isolation was FS (P<0.001), followed by A (P=0.04), Pt (P<0.001), and RD and Pa (P<0.001). Counts produced from teeth prepared with DS isolation were significantly higher at the Pt location than the A (P<0.001), FS (P=0.002), RD (P<0.001), and Pa (P=0.008) locations. Conclusion: The use of dental dam with high-volume evacuation suction during stainless steel crown preparations increased bioaerosols near the procedure, while dental evacuation systems (DryShield®) may effectively limit their spread.


Assuntos
Aerossóis , Streptococcus mutans , Humanos , Streptococcus mutans/isolamento & purificação , Aço Inoxidável , Coroas , Técnicas In Vitro , Microbiologia do Ar , Contagem de Colônia Microbiana , Biofilmes , Carga Bacteriana , Sucção/instrumentação , Controle de Infecções Dentárias/métodos
2.
Food Microbiol ; 122: 104561, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38839224

RESUMO

The current study aimed to determine if the 3D-printing speed and temperature would impact the transferability of foodborne pathogens from the stainless-steel (SS) food cartridge to the 3D-printed food ink. Staphylococcus aureus and Escherichia coli were inoculated onto the interior surface of the SS food cartridges. Subsequently, a model food ink was extruded with a recommended macronutrient contribution of 55.8, 23.7, and 20.5% of carbohydrates, proteins, and fat, respectively. The impact of 3D-printing temperatures and speeds on transfer rates was analysed using a Two-Way ANOVA. S. aureus was transferred more from the cartridge to the food ink with a population of 3.39, 2.98, and 3.09 log CFU/g compared to 2.03, 2.06, and 2.00 log CFU/g for E. coli at 2000, 3000, and 4000 mm/s printing speed, respectively, at 25 °C. A Kruskal-Wallis Test was employed to investigate the effect of different speeds and temperatures on the transferability of S. aureus and E. coli. Speed was the main factor affecting S. aureus transferability, while temperature (25 and 50 °C) had the greatest impact on E. coli transferability. This research seeks to advance the understanding of 3D-printing parameters in pathogen transferability and help the food industry move towards this technology's quick and safe adoption.


Assuntos
Escherichia coli , Microbiologia de Alimentos , Impressão Tridimensional , Staphylococcus aureus , Temperatura , Staphylococcus aureus/crescimento & desenvolvimento , Escherichia coli/crescimento & desenvolvimento , Aço Inoxidável , Manipulação de Alimentos/instrumentação , Manipulação de Alimentos/métodos , Contaminação de Alimentos/análise , Contagem de Colônia Microbiana
3.
J Med Virol ; 96(5): e29655, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38727091

RESUMO

Viruses can spread through contaminated aerosols and contaminated surface materials, and effective disinfection techniques are essential for virus inactivation. Nonthermal plasma-generated reactive oxygen and nitrogen species can effectively inactivate the coronavirus. We aim to interpret the coronavirus inactivation level and mechanism of surface interaction with materials with and without dielectric barrier discharge (DBD) plasma treatment. Nonthermal plasma, particularly surface-type DBD plasma, can inactivate human coronavirus 229E (HCoV-229E) on porous (paper, wood, mask) and nonporous (plastic, stainless steel, glass, Cu) materials. Virus inactivation was analyzed using a 50% tissue culture infectivity dose (TCID50) using cell line, flow cytometry, and immunofluorescence. Surfaces contaminated with HCoV-229E were treated at different time intervals (0-5 h) with and without plasma exposure (natural decay in ambient air conditions). HCoV-229E persistence conformed to the following order: plastic > cover glass > stainless steel > mask > wood > paper > Cu with and without plasma exposure. HCoV-229E was more stable in plastic, cover glass, and stainless steel in 5 h, and the viable virus titer gradually decreased from its initial log10 order of 6.892 to 1.72, 1.53, and 1.32 TCID50/mL, respectively, under plasma exposure. No virus was observed in Cu after treatment for 5 h. The use of airflow, ambient nitrogen, and argon did not promote virus inactivation. Flow cytometry and immunofluorescence analysis demonstrated a low expression level of spike protein (fluorescence intensity) during plasma treatment and in E and M genes expression compared with the virus control.


Assuntos
Coronavirus Humano 229E , Gases em Plasma , Inativação de Vírus , Humanos , Coronavirus Humano 229E/efeitos dos fármacos , Coronavirus Humano 229E/fisiologia , Inativação de Vírus/efeitos dos fármacos , Gases em Plasma/farmacologia , Linhagem Celular , Porosidade , Desinfecção/métodos , Aço Inoxidável
4.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38725023

RESUMO

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Assuntos
Espectroscopia Dielétrica , Teste de Materiais , Fios Ortodônticos , Saliva Artificial , Aço Inoxidável , Zinco , Corrosão , Aço Inoxidável/química , Zinco/química , Saliva Artificial/química , Ligas Dentárias/química , Materiais Revestidos Biocompatíveis/química , Fluoretos/química , Concentração de Íons de Hidrogênio , Humanos , Propriedades de Superfície , Potenciometria
5.
J Clin Pediatr Dent ; 48(3): 46-51, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38755981

RESUMO

Indirect pulp therapy (IPT) is a common conservative treatment for deep dental caries. However, the potential risk factors for the prognosis of IPT have not been well studied. This study retrospectively investigated the success rate of IPT in treating primary molars with deep caries and the factors potentially affecting the two-year success rate. A total of 303 primary molars in 202 children (106 boys and 96 girls) were included in this study. These primary molars were identified as having deep caries by clinical and radiographic examinations and were treated with IPT. The factors potentially affecting the IPT success rate were analyzed after two years of follow-up. The results indicated that the two-year IPT success rate was 86% (262/303). The success rate of primary molars with and without stainless steel crowns was 96% (120/125) and 80% (142/178), respectively. Primary molars treated with stainless steel crowns showed a significantly lower risk of failure (hazard ratio (HR) = 0.18, 95% confidence interval (CI): (0.10, 0.34), p = 0.01). There were no significant differences in other factors, including gender (male vs. female), age (preschool vs. school age), cooperation level (Frankl 2 vs. 3 or 4 scales), arch type (maxillary vs. mandibular), tooth type (first vs. second primary molar), or pulp capping material (calcium hydroxide vs. glass ionomer cement). IPT is an effective, conservative treatment modality for primary molars with deep caries. Stainless steel crowns could significantly improve the IPT success rate.


Assuntos
Coroas , Cárie Dentária , Dente Molar , Dente Decíduo , Humanos , Masculino , Estudos Retrospectivos , Feminino , Cárie Dentária/terapia , Pré-Escolar , Criança , Aço Inoxidável , Resultado do Tratamento , Capeamento da Polpa Dentária/métodos , Fatores de Risco , Seguimentos
6.
J Clin Pediatr Dent ; 48(3): 59-67, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38755983

RESUMO

The importance of aesthetics in children has increased over time. Therefore, this multicenter randomized clinical trial aimed to analyze and compare three-dimensional (3D)-printed resin crowns (RCs) as a potential alternative to stainless-steel crowns (SSCs) for restoring primary molars with extensive carious lesions. According to the null hypothesis, no statistically significant difference was observed in restoration failure between RC and SSC groups. A total of 56 primary molars after pulp treatment at two dental hospitals were included. After pulp treatment, the teeth were randomly divided into two groups: SSCs (n = 28) and RCs (n = 28). At 1 week and 3, 6 and 12 months, the Quigley-Hein plaque index (QHI), gingival index (GI), occlusal wear, and survival rate were assessed by examination, radiography and alginate impressions. No significant difference in QHI was observed between the two groups. However, the GI at 12 months and occlusal wear in the RC group were significantly higher than those in the SSC group (p < 0.05). The survival rates were 100% in the SSC group and 82.1% in the RC group (p = 0.047). Cracks and discoloration were also observed in the RCs. Within the limitations of this study, 3D-printed RCs are aesthetically superior to SSCs and clinically easy to repair. However, if clinical effectiveness and safety are improved, RCs could potentially become a viable aesthetic alternative in the future.


Assuntos
Coroas , Dente Molar , Impressão Tridimensional , Aço Inoxidável , Dente Decíduo , Humanos , Feminino , Masculino , Criança , Cárie Dentária/terapia , Restauração Dentária Permanente/métodos , Pré-Escolar , Planejamento de Prótese Dentária , Índice Periodontal , Falha de Restauração Dentária
7.
Eur J Paediatr Dent ; 25: 1, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38775099

RESUMO

AIM: Prosthetic rehabilitation of deciduous teeth in paediatric age using pre-formed crowns has been considered one of the best methods of dental restoration since their introduction. Their main advantages are related to durability, longevity and a low rate of recurrent cavities. Since stainless steel crowns do not coincide with aesthetic needs of parents and patients, preformed paedodontic crowns made of zirconia and nano-hybrid composite was introduced. The aim of the study is to evaluate the degree of wear on the enamel and on themselves of the different paedodontic crowns. MATERIALS: Nine bovine teeth and nine paedodontic crowns for deciduous molars were selected for the study, three of which in zirconia, three in nano-hybrid composite and three in stainless steel. Wear test was carried out on the Rtech™ Instruments tribometer applying a force of 50 N. After that, both the bovine teeth and the paedodontic crowns were observed using a stereo microscope (Zeiss Stemi C-500) and a scanning electron microscope (SEM, Cambridge Stereoscan 440). The areas of wear were calculated with a software [ImageJ, version 1x, Wayne Rasband, Maryland, USA]. CONCLUSION: Pre-formed paediatric crowns in zirconia, nano-hybrid composite and stainless steel are a valid aid for the restoration of deciduous teeth and do not compromise the physiological wear characteristic of the phases of the dental exchange. The stainless steel crown is preferable for the restorations in the posterior sectors as its behaviour is the most similar to that of a natural tooth. Zirconia and nano-hybrid composite crowns showed an inversely proportional behaviour between their wear volume and that of the opposing tooth.


Assuntos
Coroas , Aço Inoxidável , Dente Decíduo , Zircônio , Bovinos , Zircônio/química , Aço Inoxidável/química , Animais , Humanos , Resinas Compostas/química , Microscopia Eletrônica de Varredura , Desgaste de Restauração Dentária , Materiais Dentários/química , Esmalte Dentário , Desgaste dos Dentes , Criança
8.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775601

RESUMO

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Assuntos
Ligas Dentárias , Implantes Dentários , Resistência à Flexão , Teste de Materiais , Microscopia Eletrônica de Varredura , Procedimentos de Ancoragem Ortodôntica , Aço Inoxidável , Propriedades de Superfície , Titânio , Torque , Titânio/química , Aço Inoxidável/química , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Ligas Dentárias/química , Técnicas In Vitro , Espectrometria por Raios X , Análise do Estresse Dentário , Humanos , Estresse Mecânico , Densidade Óssea
9.
Cir Cir ; 92(2): 211-218, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38782385

RESUMO

OBJECTIVES: The aim of the study was to investigate the clinical effect of stainless-steel wire fixation on the early mouth-opening movement of an intracapsular fracture involving the condylar process. MATERIALS AND METHODS: In this study, patients who underwent mandibular condylar intracapsular fracture surgery in our hospital from 2012 to 2020 were selected as research subjects. A total of 44 patients received steel wire internal fixation treatment, 32 patients received titanium plate-and-nail rigid internal fixation, and 28 patients underwent conservative non-surgical treatment. RESULTS: For the patients in the stainless-steel wire group, the degree of mouth opening reached normal levels of 3.7 cm approximately 10 days after surgery. The recovery time for the patients in the titanium plate-and-nail rigid internal-fixation group was 21 days, while the patients in the conservative treatment group needed 60 days to recover. CONCLUSION: The treatment of fixation with a stainless-steel wire for intracapsular condylar fracture reduced the time taken to perform mouth-opening exercises and improved the recovery rate of patients.


OBJETIVO: Explorar el efecto clínico de la fijación de alambre de acero inoxidable en el movimiento temprano de apertura de la boca en la fractura interna del cóndilo. MÉTODO: Este estudio seleccionó a pacientes que se sometieron a cirugía de fractura intracapsular de cóndilo en nuestro hospital de 2012 a 2020 como sujetos de investigación. Un total de 44 pacientes recibieron tratamiento de fijación interna de alambre de acero, 32 recibieron placa de titanio y fijación interna con clavos, y 28 recibieron tratamiento conservador no quirúrgico. RESULTADOS: En los pacientes del grupo de alambre de acero inoxidable, alrededor de 10 días después de la cirugía el grado de apertura de la boca alcanzó un valor normal de 3.7 cm. El tiempo de recuperación de los pacientes en el grupo de fijación interna con clavos y placa de titanio fue de 21 días, mientras que los pacientes en el grupo de tratamiento conservador tardaron 60 días en recuperarse. CONCLUSIONES: La fijación con alambre de acero inoxidable para el tratamiento de la fractura intracapsular del cóndilo acorta el tiempo hasta la apertura de la boca y mejora la tasa de recuperación de los pacientes.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Côndilo Mandibular , Fraturas Mandibulares , Aço Inoxidável , Humanos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Mandibulares/cirurgia , Côndilo Mandibular/lesões , Côndilo Mandibular/cirurgia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Titânio , Amplitude de Movimento Articular , Pinos Ortopédicos , Adulto Jovem , Estudos Retrospectivos
10.
Meat Sci ; 214: 109534, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38749270

RESUMO

This study investigated the synergistic effects of ε-poly- L -lysine (ε-PL) and lysozyme against P. aeruginosa and L. monocytogenes biofilms. Single-culture biofilms of two bacteria were formed on silicone rubber (SR), stainless steel (SS), and beef surfaces and then treated with lysozyme (0.05-5 mg/mL) and ε-PL at minimum inhibitory concentrations (MICs) of 1 to 4 separately or in combination. On the SR surface, P. aeruginosa biofilm was reduced by 1.4 and 1.9 log CFU/cm2 within 2 h when treated with lysozyme (5 mg/mL) and ε-PL (4 MIC), respectively, but this reduction increased significantly to 4.1 log CFU/cm2 (P < 0.05) with the combined treatment. On beef surface, P. aeruginosa and L. monocytogenes biofilm was reduced by 4.2-5.0, and 3.3-4.2 log CFU/g when lysozyme was combined with 1, 2, and 4 MIC of ε-PL at 25 °C, respectively. Compared to 5 mg/mL lysozyme alone, the combined treatment with 1, 2, and 4 MIC of ε-PL on beef surface achieved additional reduction against P. aeruginosa biofilm of 0.5, 0.8, and 0.7 log CFU/g, respectively, at 25 °C. In addition, 0.25 mg/mL lysozyme and 0.5 MIC of ε-PL significantly (P < 0.05) suppressed the quorum-sensing (agrA) and virulence-associated (hlyA and prfA) genes of L. monocytogenes.


Assuntos
Biofilmes , Listeria monocytogenes , Muramidase , Polilisina , Pseudomonas aeruginosa , Pseudomonas aeruginosa/efeitos dos fármacos , Muramidase/farmacologia , Biofilmes/efeitos dos fármacos , Animais , Listeria monocytogenes/efeitos dos fármacos , Polilisina/farmacologia , Bovinos , Sinergismo Farmacológico , Testes de Sensibilidade Microbiana , Carne Vermelha/microbiologia , Microbiologia de Alimentos , Aço Inoxidável , Antibacterianos/farmacologia
11.
Clin Oral Investig ; 28(5): 294, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698252

RESUMO

OBJECTIVES: To compare ultrasonic scaler prototypes based on a planar piezoelectric transducer with different working frequencies featuring a titanium (Ti-20, Ti-28, and Ti-40) or stainless steel (SS-28) instrument, with a commercially available scaler (com-29) in terms of biofilm removal and reformation, dentine surface roughness and adhesion of periodontal fibroblasts. MATERIALS AND METHODS: A periodontal multi-species biofilm was formed on specimens with dentine slices. Thereafter specimens were instrumented with scalers in a periodontal pocket model or left untreated (control). The remaining biofilms were quantified and allowed to reform on instrumented dentine slices. In addition, fibroblasts were seeded for attachment evaluation after 72 h of incubation. Dentine surface roughness was analyzed before and after instrumentation. RESULTS: All tested instruments reduced the colony-forming unit (cfu) counts by about 3 to 4 log10 and the biofilm quantity (each p < 0.01 vs. control), but with no statistically significant difference between the instrumented groups. After 24-hour biofilm reformation, no differences in cfu counts were observed between any groups, but the biofilm quantity was about 50% in all instrumented groups compared to the control. The attachment of fibroblasts on instrumented dentine was significantly higher than on untreated dentine (p < 0.05), with the exception of Ti-20. The dentine surface roughness was not affected by any instrumentation. CONCLUSIONS: The planar piezoelectric scaler prototypes are able to efficiently remove biofilm without dentine surface alterations, regardless of the operating frequency or instrument material. CLINICAL RELEVANCE: Ultrasonic scalers based on a planar piezoelectric transducer might be an alternative to currently available ultrasonic scalers.


Assuntos
Biofilmes , Raspagem Dentária , Dentina , Fibroblastos , Ligamento Periodontal , Propriedades de Superfície , Titânio , Humanos , Raspagem Dentária/instrumentação , Técnicas In Vitro , Dentina/microbiologia , Ligamento Periodontal/citologia , Transdutores , Adesão Celular , Aço Inoxidável , Desenho de Equipamento , Terapia por Ultrassom/instrumentação
12.
Clin Oral Investig ; 28(6): 323, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38761310

RESUMO

OBJECTIVES: White spot lesions are the most common iatrogenic effect observed during orthodontic treatment. This study aimed to compare the surface characteristics and antibacterial action of uncoated and coated orthodontic brackets. MATERIALS AND METHODS: Sixty commercially available stainless steel brackets were coated with TiO2 nanotubes and methacryloyloxyethylphosphorylcholine. The sample was divided into Group 1: uncoated orthodontic brackets, Group 2: Stainless steel brackets with TiO2 nanotubes coating, Group 3: Stainless steel brackets with methacryloyloxyethylphosphorylcholine coating, and Group 4: Stainless steel brackets with TiO2 nanotubes combined with methacryloyloxyethylphosphorylcholine coating. Surface characterization was assessed using atomic force microscopy and scanning electron microscopy. Streptococcus mutans was selected to test the antibacterial ability of the orthodontic brackets, total bacterial adhesion and bacterial viability were assessed. The brackets were subjected to scanning electron microscopy to detect the presence of biofilm. RESULTS: The surface roughness was the greatest in Group 1 and least in Group 2 followed by Group 4 and Group 3 coated brackets. The optical density values were highest in Group 1 and lowest in Group 4. Comparison of colony counts revealed high counts in Group 1 and low counts in Group 4. A positive correlation between surface roughness and colony counts was obtained, however, was not statistically significant. CONCLUSIONS: The coated orthodontic brackets exhibited less surface roughness than the uncoated orthodontic brackets. Group 4 coated orthodontic brackets showed the best antibacterial properties. CLINICAL RELEVANCE: Coated orthodontic brackets prevent adhesion of streptococcus mutans and reduces plaque accumulation around the brackets thereby preventing formation of white spot lesions during orthodontic treatment.


Assuntos
Antibacterianos , Aderência Bacteriana , Microscopia Eletrônica de Varredura , Nanotubos , Braquetes Ortodônticos , Fosforilcolina , Streptococcus mutans , Propriedades de Superfície , Titânio , Titânio/química , Fosforilcolina/análogos & derivados , Fosforilcolina/farmacologia , Fosforilcolina/química , Streptococcus mutans/efeitos dos fármacos , Antibacterianos/farmacologia , Nanotubos/química , Aderência Bacteriana/efeitos dos fármacos , Microscopia de Força Atômica , Teste de Materiais , Aço Inoxidável/química , Metacrilatos/farmacologia , Metacrilatos/química , Biofilmes/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química
13.
Sci Rep ; 14(1): 8882, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632263

RESUMO

Wearable long-term monitoring applications are becoming more and more popular in both the consumer and the medical market. In wearable ECG monitoring, the data quality depends on the properties of the electrodes and on how they interface with the skin. Dry electrodes do not require any action from the user. They usually do not irritate the skin, and they provide sufficiently high-quality data for ECG monitoring purposes during low-intensity user activity. We investigated prospective motion artifact-resistant dry electrode materials for wearable ECG monitoring. The tested materials were (1) porous: conductive polymer, conductive silver fabric; and (2) solid: stainless steel, silver, and platinum. ECG was acquired from test subjects in a 10-min continuous settling test and in a 48-h intermittent long-term test. In the settling test, the electrodes were stationary, whereas both stationary and controlled motion artifact tests were included in the long-term test. The signal-to-noise ratio (SNR) was used as the figure of merit to quantify the results. Skin-electrode interface impedance was measured to quantify its effect on the ECG, as well as to leverage the dry electrode ECG amplifier design. The SNR of all electrode types increased during the settling test. In the long-term test, the SNR was generally elevated further. The introduction of electrode movement reduced the SNR markedly. Solid electrodes had a higher SNR and lower skin-electrode impedance than porous electrodes. In the stationary testing, stainless steel showed the highest SNR, followed by platinum, silver, conductive polymer, and conductive fabric. In the movement testing, the order was platinum, stainless steel, silver, conductive polymer, and conductive fabric.


Assuntos
Artefatos , Aço Inoxidável , Humanos , Platina , Prata , Estudos Prospectivos , Eletrocardiografia/métodos , Impedância Elétrica , Eletrodos , Polímeros
14.
J Indian Soc Pedod Prev Dent ; 42(1): 37-45, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38616425

RESUMO

PURPOSE: The purpose of this clinical trial was to assess and compare the clinical outcomes of Bioflx crowns (BFCs) with stainless steel crowns (SSCs) in primary molars (PMs). MATERIALS AND METHODS: This prospective split-mouth randomized controlled clinical trial was conducted between March 2022 and June 2023. Thirty-eight patients (17 females and 21 males) with a mean age of 5.21 years participated in this study. Each child (n = 38) received both SSC and BFC. Clinical and radiographic follow-up was performed at baseline, 3, 6, and 12 months using the modified United States Public Health System scoring criteria to evaluate various parameters. RESULTS: At the 3 and 6 months' follow-up, no significant difference was observed between the two groups. However, at 1-year follow-up, a statistically significant difference (P < 0.05) was evident in the frequency between the two groups for the criteria of crown retention after cementation and anatomic form of the crown, indicating a preference for SSC over prototype 1 BFC. CONCLUSION: The 12-month results indicate that BFC performed similarly to the established SSC for the restoration of PMs providing better esthetics.


Assuntos
Boca , Aço Inoxidável , Criança , Feminino , Masculino , Humanos , Pré-Escolar , Estudos Prospectivos , Coroas , Dente Molar
15.
Food Microbiol ; 121: 104531, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38637091

RESUMO

The present study aimed to assess the occurrence and counts of Staphylococcus aureus in Brazilian artisanal cheeses (BAC) produced in five regions of Brazil: Coalho and Manteiga (Northeast region); Colonial and Serrano (South); Caipira (Central-West); Marajó (North); and Minas Artisanal cheeses, from Araxá, Campos das Vertentes, Cerrado, Serro and Canastra microregions (Southeast). The resistance to chlorine-based sanitizers, ability to attach to stainless steel surfaces, and antibiogram profile of a large set of S. aureus strains (n = 585) were assessed. Further, a total of 42 isolates were evaluated for the presence of enterotoxigenic genes (sea, seb, sec, sed, see, seg, sei, sej, and ser) and submitted to typing using pulsed-field gel electrophoresis (PFGE). BAC presented high counts of S. aureus (3.4-6.4 log CFU/g), varying from 25 to 62.5%. From the S. aureus strains (n = 585) assessed, 16% could resist 200 ppm of sodium hypochlorite, whereas 87.6% produced strong ability to attach to stainless steel surfaces, corroborating with S. aureus ability to persist and spread in the environment. Furthermore, the relatively high frequency (80.5%) of multidrug-resistant S. aureus and the presence of enterotoxin genes in 92.6% of the strains is of utmost attention. It reveals the lurking threat of SFP that can survive when conditions are favorable. The presence of enterotoxigenic and antimicrobial-resistant strains of S. aureus in cheese constitutes a potential risk to public health. This result calls for better control of cheese contamination sources, and taking hygienic measures is necessary for food safety. More attention should be paid to animal welfare and hygiene practices in some dairy farms during manufacturing to enhance the microbiological quality of traditional cheese products.


Assuntos
Queijo , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Animais , Staphylococcus aureus/genética , Queijo/microbiologia , Brasil , Microbiologia de Alimentos , Aço Inoxidável/análise , Enterotoxinas/genética , Leite/microbiologia
16.
Food Microbiol ; 121: 104491, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38637093

RESUMO

The effect of lactocin AL705, bacteriocin produced by Latilactobacillus (Lat.) curvatus CRL1579 against Listeria biofilms on stainless steel (SS) and polytetrafluoroethylene (PTFE) coupons at 10 °C was investigated. L. monocytogenes FBUNT showed the greatest adhesion on both surfaces associated to the hydrophobicity of cell surface. Partially purified bacteriocin (800 UA/mL) effectively inhibited L. monocytogenes preformed biofilm through displacement strategy, reducing the pathogen by 5.54 ± 0.26 and 4.74 ± 0.05 log cycles at 3 and 6 days, respectively. The bacteriocin-producer decreased the pathogen biofilm by ∼2.84 log cycles. Control and Bac- treated samples reached cell counts of 7.05 ± 0.18 and 6.79 ± 0.06 log CFU/cm2 after 6 days of incubation. Confocal scanning laser microscopy (CLSM) allowed visualizing the inhibitory effect of lactocin AL705 on L. monocytogenes preformed biofilms under static and hydrodynamic flow conditions. A greater effect of the bacteriocin was found at 3 days independently of the surface matrix and pathogen growth conditions at 10 °C. As a more realistic approach, biofilm displacement strategy under continuous flow conditions showed a significant loss of biomass, mean thickness and substratum coverage of pathogen biofilm. These findings highlight the anti-biofilm capacity of lactocin AL705 and their potential application in food industries.


Assuntos
Bacteriocinas , Listeria monocytogenes , Listeria , Biofilmes , Bacteriocinas/farmacologia , Lactobacillus , Aço Inoxidável/análise , Microbiologia de Alimentos
17.
Colloids Surf B Biointerfaces ; 238: 113908, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38677153

RESUMO

In response to the critical demand for advancements in coronary artery stents, this study addresses the challenges associated with arterial recoil and restenosis post-angioplasty and the imperative to encourage rapid re-endothelialization for minimizing thrombosis risks. We employed an innovative approach inspired by mussel adhesion, incorporating placental anticoagulant protein (AnnexinV) on stent design. The introduction of a post-translationally modified catecholic amino acid L-3,4-dihydroxyphenylalanine (L-Dopa), mimicking mussel characteristics, allowed for effective surface modification of Stainless steel stents through genetic code engineering in AnnexinV (AnxDopa). The efficacy of AnxDopa was analyzed through microscale thermophoresis and flow cytometry, confirming AnxDopa's exceptional binding with phosphatidylserine and activated platelets. AnxDopa coated stainless steel demonstrates remarkable bio-, hemo-, and immuno-compatibility, preventing smooth muscle cell proliferation, platelet adhesion, and fibrin formation. It acts as an interface between the stent and biological fluid, which facilitates the anticoagulation and rapid endothelialization. Surface modification of SS verified through XPS analysis and contact angle measurement attests to the efficacy of AnxDopa mediated surface modification. The hydrophilic nature of the AnxDopa-coated surface enhanced the endothelialization through increased protein absorption. This approach represents a significant stride in developing coronary stents with improved biocompatibility and reduced restenosis risks, offering valuable contributions to scientific and clinical realms alike.


Assuntos
Materiais Revestidos Biocompatíveis , Stents , Humanos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Vasos Coronários/efeitos dos fármacos , Adesividade Plaquetária/efeitos dos fármacos , Anticoagulantes/farmacologia , Anticoagulantes/química , Propriedades de Superfície , Proliferação de Células/efeitos dos fármacos , Aço Inoxidável/química , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Miócitos de Músculo Liso/efeitos dos fármacos , Miócitos de Músculo Liso/metabolismo , Miócitos de Músculo Liso/citologia , Animais , Levodopa/química , Levodopa/farmacologia
18.
J Appl Microbiol ; 135(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38609348

RESUMO

AIM: Evaluate the efficacy of sponge wipe sampling at recovering potential bacterial surrogates for Category A and B non-spore-forming bacterial bioterrorism agents from hard, nonporous surfaces. METHODS: A literature survey identified seven nonpathogenic bacteria as potential surrogates for selected Category A and B non-spore-forming bacterial agents. Small (2 × 4 cm) and large (35.6 × 35.6 cm) coupons made from either stainless steel, plastic, or glass, were inoculated and utilized to assess persistence and surface sampling efficiency, respectively. Three commercially available premoistened sponge wipes (3M™, Sani-Stick®, and Solar-Cult®) were evaluated. RESULTS: Mean recoveries from persistence testing indicated that three microorganisms (Yersinia ruckeri, Escherichia coli, and Serratia marcescens) demonstrated sufficient persistence across all tested material types. Sampling of large inoculated (≥107 CFU per sample) coupons resulted in mean recoveries ranging from 6.6 to 3.4 Log10 CFU per sample. Mean recoveries for the Solar-Cult®, 3M™ sponge wipes, and Sani-Sticks® across all test organisms and all material types were ≥5.7, ≥3.7, and ≥3.4 Log10 CFU per sample, respectively. Mean recoveries for glass, stainless steel, and ABS plastic across all test organisms and all sponge types were ≥3.8, ≥3.7, and ≥3.4 Log10 CFU per sample, respectively. CONCLUSIONS: Recovery results suggest that sponge wipe sampling can effectively be used to recover non-spore-forming bacterial cells from hard, nonporous surfaces such as stainless steel, ABS plastic, and glass.


Assuntos
Bioterrorismo , Aço Inoxidável , Bactérias/isolamento & purificação , Plásticos , Escherichia coli/isolamento & purificação , Serratia marcescens/isolamento & purificação , Vidro , Contagem de Colônia Microbiana , Armas Biológicas
19.
Eur J Orthop Surg Traumatol ; 34(4): 2147-2153, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38564013

RESUMO

INTRODUCTION: Distal femur fractures account for 3-6% of all femur fractures. Internal fixation of most distal femur fractures with an anatomic lateral locking plate should permit some motion at the metaphyseal portion of the fracture when secondary bone healing is planned by the operating surgeon. While several studies have been performed evaluating union rates for distal femur fractures with stainless steel and titanium plates, the timing of callus formation between stainless steel and titanium implants used as bridge plates for distal femur fractures (AO/OTA 33-A and -C) has been investigated to a lesser extent. We hypothesize that callus will be visualized earlier with post-operative radiographs with titanium versus stainless steel bridge plates. METHODS: We retrospectively reviewed a consecutive cohort of patients over 18 years of age with acute AO/OTA 33-A and 33-C fracture patterns treated with an isolated stainless steel or titanium lateral bridge plate within 4 weeks of injury by a single fellowship-trained orthopedic trauma surgeon from 2011 to 2020 at one academic Level 1 trauma center. An independent, fellowship-trained orthopedic trauma attending surgeon reviewed anterior-posterior (AP) and lateral radiographs from every available post-operative clinic visit and graded them using the Modified Radiographic Score for Tibia (mRUST). RESULTS: Twenty-five subjects were included in the study with 10 with stainless steel and 15 with titanium plates. There were no significant differences in demographics between both groups, including age, sex, BMI, injury classification, open versus closed, mechanism, and laterality. Statistically significant increased mRUST scores, indicating increased callus formation, were seen on 12-week radiographs (8.4 vs. 11.9, p = 0.02) when titanium bridge plates were used. There were no statistically significant differences in mRUST scores at 6 or 24-weeks, but scores in the titanium group were higher in at every timepoint. DISCUSSION: In conclusion, we observed greater callus formation at 12 weeks after internal fixation of 33-A and 33-C distal femur fractures treated with titanium locked lateral distal femoral bridge plates compared to stainless steel plates. Our data suggest that titanium metallurgy may have quicker callus formation compared to stainless steel if an isolated, lateral locked bridge plate is chosen for distal femur fracture fixation.


Assuntos
Placas Ósseas , Calo Ósseo , Fraturas do Fêmur , Fixação Interna de Fraturas , Aço Inoxidável , Titânio , Humanos , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/fisiopatologia , Estudos Retrospectivos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Masculino , Calo Ósseo/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Adulto , Radiografia , Consolidação da Fratura/fisiologia , Idoso , Fraturas Femorais Distais
20.
ACS Appl Bio Mater ; 7(5): 2966-2981, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38652577

RESUMO

This study presents a facile fabrication of 58S bioactive glass (BG)-polymer composite coatings on a 316L stainless steel (SS) substrate using the electrophoretic deposition technique. The suspension characteristics and deposition kinetics of BG, along with three different polymers, namely ethylcellulose (EC), poly(acrylic acid) (PAA), and polyvinylpyrrolidone (PVP), have been utilized to fabricate the coatings. Among all coatings, 58S BG and EC polymers are selected as the final composite coating (EC6) owing to their homogeneity and good adhesion. EC6 coating exhibits a thickness of ∼18 µm and an average roughness of ∼2.5 µm. Herein, EC6 demonstrates better hydroxyapatite formation compared to PAA and PVP coatings in simulated body fluid-based mineralization studies for a period of 28 days. Corrosion studies of EC6 in phosphate-buffered saline further confirm the higher corrosion resistance properties after 14 days. In vitro cytocompatibility studies using human placental mesenchymal stem cells demonstrate an increase in cellular viability, attachment, and higher proliferation compared to the bare SS substrate. EC6 coatings promote osteogenic differentiation, which is confirmed via the upregulation of the OPN and OCN genes. Moreover, the EC6 sample exhibits improved antibacterial properties against Escherichia coli and Staphylococcus aureus compared to the uncoated ones. The findings of this work emphasize the potential of electrophoretically fabricated BG-EC composite coatings on SS substrates for orthopedic applications.


Assuntos
Materiais Revestidos Biocompatíveis , Vidro , Teste de Materiais , Polímeros , Aço Inoxidável , Aço Inoxidável/química , Humanos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Vidro/química , Polímeros/química , Polímeros/farmacologia , Corrosão , Tamanho da Partícula , Propriedades de Superfície , Antibacterianos/farmacologia , Antibacterianos/química , Escherichia coli/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Eletroforese , Sobrevivência Celular/efeitos dos fármacos , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Testes de Sensibilidade Microbiana , Proliferação de Células/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...