Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32.496
Filtrar
1.
Adv Exp Med Biol ; 1441: 185-200, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38884712

RESUMO

The electrical impulses that coordinate the sequential, rhythmic contractions of the atria and ventricles are initiated and tightly regulated by the specialized tissues of the cardiac conduction system. In the mature heart, these impulses are generated by the pacemaker cardiomyocytes of the sinoatrial node, propagated through the atria to the atrioventricular node where they are delayed and then rapidly propagated to the atrioventricular bundle, right and left bundle branches, and finally, the peripheral ventricular conduction system. Each of these specialized components arise by complex patterning events during embryonic development. This chapter addresses the origins and transcriptional networks and signaling pathways that drive the development and maintain the function of the cardiac conduction system.


Assuntos
Sistema de Condução Cardíaco , Animais , Humanos , Nó Atrioventricular/fisiologia , Nó Atrioventricular/embriologia , Regulação da Expressão Gênica no Desenvolvimento , Sistema de Condução Cardíaco/fisiologia , Miócitos Cardíacos/fisiologia , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/citologia , Transdução de Sinais , Nó Sinoatrial/fisiologia , Nó Sinoatrial/embriologia
2.
Turk Kardiyol Dern Ars ; 52(4): 237-243, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38829634

RESUMO

OBJECTIVE: This study aims to explore the impact of sodium-glucose cotransporter-2 (SGLT-2) inhibitors, a newer class of oral antidiabetic drugs, on atrial electromechanical delay (EMD) in patients with type 2 diabetes mellitus (DM). This is particularly relevant given the significantly higher incidence of atrial fibrillation (AF) in diabetic patients compared to the general population. Atrial electromechanical delay is recognized as an important factor influencing the development of atrial fibrillation. METHODS: This study included 30 type 2 DM patients (53.3% female, mean age 60.07 ± 10.03 years), initiating treatment with SGLT-2 inhibitors. The patients were assessed using echocardiography at baseline and again at 6 months, focusing on basic echocardiographic parameters and atrial electromechanical delay times (EMD) measured via tissue Doppler imaging. RESULTS: No significant changes were observed in intra-atrial EMD times. However, significant reductions were noted in interatrial EMD times, decreasing from 15.13 ± 5.87 ms to 13.20 ± 6.12 ms (P = 0.029). Statistically significant shortening occurred in lateral pulmonary acceleration (PA) times (from 58.73 ± 6.41 ms to 54.37 ± 6.97 ms, P < 0.001), septal PA times (from 50.90 ± 6.02 ms to 48.23 ± 5), and tricuspid PA times (from 43.60 ± 6.28 ms to 41.30 ± 5.60 ms, P = 0.003). Additionally, there was a significant reduction in the E/e' ratio from 8.13 ± 4.0 to 6.50 ± 2.37 (P = 0.003). CONCLUSION: SGLT-2 inhibitors might positively influence atrial electromechanical conduction, reducing DM-related functional impairments and the risk of arrhythmias, particularly AF.


Assuntos
Fibrilação Atrial , Diabetes Mellitus Tipo 2 , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Feminino , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Inibidores do Transportador 2 de Sódio-Glicose/farmacologia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/complicações , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/fisiopatologia , Idoso , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Ecocardiografia
5.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691562

RESUMO

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Septo Interventricular , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem , Idoso de 80 Anos ou mais , Fatores de Risco , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Resultado do Tratamento , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença , Estudos Retrospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Potenciais de Ação
6.
Card Electrophysiol Clin ; 16(2): 163-168, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749636

RESUMO

A 69-year-old woman with a history of heart failure with reduced ejection fraction presented for device interrogation of her cardiac implantable electronic device (CIED), revealing lead and pulse generator displacement. Surprisingly, she exhibited a narrow QRS on the ECG despite an underlying right bundle branch block, suggesting unintentional conduction system pacing (CSP). Traditional cardiac resynchronization therapy has been widely used for patients with heart failure, but alternatives like CSP are emerging as viable options. Given the global rise in CIED utilization, regular follow-up, device troubleshooting, and embracing remote monitoring are essential to manage and optimize patient outcomes.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Feminino , Humanos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Falha de Equipamento , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia
7.
J Electrocardiol ; 84: 161-164, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38733733

RESUMO

Since the introduction of left bundle branch pacing (LBBP), a search for precise parameters confirming successful capture of conduction system was conducted. Most of the proposed electrocardiographic criteria refer to patients with narrow QRS complexes. We present a patient with heart failure in whom cardiac resynchronization was achieved using conduction system pacing. While measuring left ventricular activation time, an isoelectric interval of 74 ms between stimulus and R-wave appeared resulting in prolongation of V6 RWPT to 124 ms. Considering the immediate narrowing of QRS complexes following LBBP, the observed latency most probably reflects prolonged conduction time through the His-Purkinje system.


Assuntos
Bloqueio de Ramo , Eletrocardiografia , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Masculino , Terapia de Ressincronização Cardíaca/métodos , Fascículo Atrioventricular/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Resultado do Tratamento , Idoso , Pessoa de Meia-Idade
8.
Expert Opin Ther Targets ; 28(5): 385-400, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38700451

RESUMO

INTRODUCTION: The cardiac conduction system (CCS) is crucial for maintaining adequate cardiac frequency at rest and modulation during exercise. Furthermore, the atrioventricular node and His-Purkinje system are essential for maintaining atrioventricular and interventricular synchrony and consequently maintaining an adequate cardiac output. AREAS COVERED: In this review article, we examine the anatomy, physiology, and pathophysiology of the CCS. We then discuss in detail the most common genetic mutations and the molecular mechanisms of cardiac conduction disease (CCD) and provide our perspectives on future research and therapeutic opportunities in this field. EXPERT OPINION: Significant advancement has been made in understanding the molecular mechanisms of CCD, including the recognition of the heterogeneous signaling at the subcellular levels of sinoatrial node, the involvement of inflammatory and autoimmune mechanisms, and the potential impact of epigenetic regulations on CCD. However, the current treatment of CCD manifested as bradycardia still relies primarily on cardiovascular implantable electronic devices (CIEDs). On the other hand, an If specific inhibitor was developed to treat inappropriate sinus tachycardia and sinus tachycardia in heart failure patients with reduced ejection fraction. More work is needed to translate current knowledge into pharmacologic or genetic interventions for the management of CCDs.


Assuntos
Doença do Sistema de Condução Cardíaco , Sistema de Condução Cardíaco , Terapia de Alvo Molecular , Humanos , Animais , Sistema de Condução Cardíaco/fisiopatologia , Doença do Sistema de Condução Cardíaco/fisiopatologia , Doença do Sistema de Condução Cardíaco/terapia , Doença do Sistema de Condução Cardíaco/tratamento farmacológico , Mutação , Desenvolvimento de Medicamentos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/tratamento farmacológico , Epigênese Genética , Nó Sinoatrial/fisiopatologia
9.
Arch Cardiovasc Dis ; 117(5): 304-312, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38704289

RESUMO

BACKGROUND: Aortic valve infective endocarditis may be complicated by high-degree atrioventricular block in up to 10-20% of cases. AIM: To assess high-degree atrioventricular block occurrence, contributing factors, prognosis and evolution in patients referred for aortic infective endocarditis. METHODS: Two hundred and five patients referred for aortic valve infective endocarditis between January 2018 and March 2021 were included in this study. A comprehensive assessment of clinical, electrocardiographic, biological, microbiological and imaging data was conducted, with a follow-up carried out over 1 year. RESULTS: High-degree atrioventricular block occurred in 22 (11%) patients. In univariate analysis, high-degree atrioventricular block was associated with first-degree heart block at admission (odds ratio 3.1; P=0.015), periannular complication on echocardiography (odds ratio 6.9; P<0.001) and severe biological inflammatory syndrome, notably C-reactive protein (127 vs 90mg/L; P=0.011). In-hospital mortality (12.7%) was higher in patients with high-degree atrioventricular block (odds ratio 4.0; P=0.011) in univariate analysis. Of the 16 patients implanted with a permanent pacemaker for high-degree atrioventricular block and interrogated, only four (25%) were dependent on the pacing function at 1-year follow-up. CONCLUSIONS: High-degree atrioventricular block is associated with high inflammation markers and periannular complications, especially if first-degree heart block is identified at admission. High-degree atrioventricular block is a marker of infectious severity, and tends to raise the in-hospital mortality rate. Systematic assessment of patients admitted for infective endocarditis suspicion, considering these contributing factors, could indicate intensive care unit monitoring or even temporary pacemaker implantation in those at highest risk.


Assuntos
Valva Aórtica , Bloqueio Atrioventricular , Mortalidade Hospitalar , Marca-Passo Artificial , Humanos , Masculino , Feminino , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/mortalidade , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/microbiologia , Fatores de Tempo , Endocardite/mortalidade , Endocardite/diagnóstico , Endocardite/complicações , Estimulação Cardíaca Artificial , Estudos Retrospectivos , Adulto , Medição de Risco , Eletrocardiografia , Frequência Cardíaca , Idoso de 80 Anos ou mais , Sistema de Condução Cardíaco/fisiopatologia
10.
Arch Cardiovasc Dis ; 117(5): 313-320, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38704288

RESUMO

BACKGROUND: In patients with congenital long QT syndrome (LQTS), the risk of ventricular arrhythmia is correlated with the duration of the corrected QT interval and the changes in the ST-T wave pattern on the 12-lead surface electrocardiogram (12L-ECG). Remote monitoring of these variables could be useful. AIM: To evaluate the abilities of two wearable electrocardiogram devices (Apple Watch and KardiaMobile 6L) to provide reliable electrocardiograms in terms of corrected QT interval and ST-T wave patterns in patients with LQTS. METHODS: In a prospective multicentre study (ClinicalTrials.gov identifier: NCT04728100), a 12L-ECG, a 6-lead KardiaMobile 6L electrocardiogram and two single-lead Apple Watch electrocardiograms were recorded in patients with LQTS. The corrected QT interval and ST-T wave patterns were evaluated manually. RESULTS: Overall, 98 patients with LQTS were included; 12.2% were children and 92.8% had a pathogenic variant in an LQTS gene. The main genotypes were LQTS type 1 (40.8%), LQTS type 2 (36.7%) and LQTS type 3 (7.1%); rarer genotypes were also represented. When comparing the ST-T wave patterns obtained with the 12L-ECG, the level of agreement was moderate with the Apple Watch (k=0.593) and substantial with the KardiaMobile 6L (k=0.651). Regarding the corrected QT interval, the correlation with 12L-ECG was strong for the Apple Watch (r=0.703 in lead II) and moderate for the KardiaMobile 6L (r=0.593). There was a slight overestimation of corrected QT interval with the Apple Watch and a subtle underestimation with the KardiaMobile 6L. CONCLUSIONS: In patients with LQTS, the corrected QT interval and ST-T wave patterns obtained with the Apple Watch and the KardiaMobile 6L correlated with the 12L-ECG. Although wearable electrocardiogram devices cannot replace the 12L-ECG for the follow-up of these patients, they could be interesting additional monitoring tools.


Assuntos
Frequência Cardíaca , Síndrome do QT Longo , Valor Preditivo dos Testes , Dispositivos Eletrônicos Vestíveis , Humanos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/congênito , Síndrome do QT Longo/genética , Feminino , Masculino , Estudos Prospectivos , Criança , Adolescente , Adulto , Reprodutibilidade dos Testes , Adulto Jovem , Eletrocardiografia Ambulatorial/instrumentação , Potenciais de Ação , Pré-Escolar , Desenho de Equipamento , Fatores de Tempo , Pessoa de Meia-Idade , Eletrocardiografia/instrumentação , Sistema de Condução Cardíaco/fisiopatologia
11.
G Ital Cardiol (Rome) ; 25(5): 327-339, 2024 05.
Artigo em Italiano | MEDLINE | ID: mdl-38639123

RESUMO

For many years, cardiac pacing has been based on the stimulation of right ventricular common myocardium to correct diseases of the conduction system. The birth and the development of cardiac resynchronization have led to growing interest in the correction and prevention of pacing-induced dyssynchrony. Many observational studies and some randomized clinical trials have shown that conduction system pacing (CSP) can not only prevent pacing-induced dyssynchrony but can also correct proximal conduction system blocks, with reduction of QRS duration and with equal or greater effectiveness than biventricular pacing. Based on these results, many Italian electrophysiologists have changed the stimulation target from the right ventricular common myocardium to CSP. The two techniques with greater clinical impact are the His bundle stimulation and the left bundle branch pacing. The latter, in particular, because of its easier implantation technique and better electric parameters, is spreading like wildfire and is representing a real revolution in the cardiac pacing field. However, despite the growing amount of data, until now, the European Society of Cardiology guidelines give a very limited role to CSP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Bloqueio de Ramo , Resultado do Tratamento , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Miocárdio , Insuficiência Cardíaca/terapia
12.
Cardiovasc Toxicol ; 24(5): 472-480, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38630336

RESUMO

The challenge posed by opioid overdose has become a significant concern for health systems due to the complexities associated with drug prohibition, widespread clinical use, and potential abuse. In response, healthcare professionals have primarily concentrated on mitigating the hallucinogenic and respiratory depressant consequences of opioid overdose to minimize associated risks. However, it is crucial to acknowledge that most opioids possess the capacity to prolong the QT interval, particularly in cases of overdose, thereby potentially resulting in severe ventricular arrhythmias and even sudden death if timely intervention is not implemented. Consequently, alongside addressing the typical adverse effects of opioids, it is imperative to consider their cardiotoxicity. To enhance comprehension of the correlation between opioids and arrhythmias, identify potential targets for prompt intervention, and mitigate the hazards associated with clinical utilization, an exploration of the interaction between drugs and ion channels, as well as their underlying mechanisms, becomes indispensable. This review primarily concentrates on elucidating the impact of opioid drugs on diverse ion channels, investigating recent advancements in this domain, and attaining a deeper understanding of the mechanisms underlying the prolongation of the QT interval by opioid drugs, along with potential interventions.


Assuntos
Analgésicos Opioides , Cardiotoxicidade , Síndrome do QT Longo , Humanos , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/fisiopatologia , Analgésicos Opioides/efeitos adversos , Animais , Medição de Risco , Fatores de Risco , Frequência Cardíaca/efeitos dos fármacos , Potenciais de Ação/efeitos dos fármacos , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Canais Iônicos/metabolismo , Canais Iônicos/efeitos dos fármacos , Overdose de Opiáceos/fisiopatologia
13.
Am J Cardiol ; 221: 129-130, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38643927

RESUMO

Atrial fibrillation (AF) was largely ignored by cardiac electrophysiologists until it was first suggested in 1998 that it might be amenable to catheter ablation. In the 25 years since then, a vast body of knowledge has emerged, initially reporting the "hypes and hopes" that ablation was appropriate for all but more recently acknowledging that not all patients benefit from this approach. The AF "epidemic" and more holistic understanding of the complex contributors to its development question whether it is even meaningful to consider AF a single condition that is always responsive to ablation management. In this issue, Masuda et al11 provide novel insights into the electrophysiologic "footprints" that they found in the body of the left atrium of patients who underwent a second ablation procedure after achieving pulmonary vein isolation. In conclusion, the findings require prospective validation but may show a way of achieving antiarrhythmic success in a cohort of patients responding unpredictably to current ablation strategies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Átrios do Coração/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos
14.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639381

RESUMO

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Assuntos
Fibrilação Atrial , Estimulação Cardíaca Artificial , Ablação por Cateter , Átrios do Coração , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Feminino , Masculino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Estimulação Cardíaca Artificial/métodos , Idoso , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Pericárdio/cirurgia , Pericárdio/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca/fisiologia
15.
Tex Heart Inst J ; 51(1)2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564374

RESUMO

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Adulto Jovem , Adulto , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial/efeitos adversos , Sistema de Condução Cardíaco , Ventrículos do Coração , Resultado do Tratamento
18.
Cardiovasc Pathol ; 70: 107626, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38458505

RESUMO

Iatrogenic damage to the cardiac conduction system (CCS) remains a significant risk during congenital heart surgery. Current surgical best practice involves using superficial anatomical landmarks to locate and avoid damaging the CCS. Prior work indicates inherent variability in the anatomy of the CCS and supporting tissues. This study introduces high-resolution, 3D models of the CCS in normal pediatric human hearts to evaluate variability in the nodes and surrounding structures. Human pediatric hearts were obtained with an average donor age of 2.7 days. A pipeline was developed to excise, section, stain, and image atrioventricular (AVN) and sinus nodal (SN) tissue regions. A convolutional neural network was trained to enable precise multi-class segmentation of whole-slide images, which were subsequently used to generate high- resolution 3D tissue models. Nodal tissue region models were created. All models (10 AVN, 8 SN) contain tissue composition of neural tissue, vasculature, and nodal tissues at micrometer resolution. We describe novel nodal anatomical variations. We found that the depth of the His bundle in females was on average 304 µm shallower than those of male patients. These models provide surgeons with insight into the heterogeneity of the nodal regions and the intricate relationships between the CCS and surrounding structures.


Assuntos
Nó Atrioventricular , Imageamento Tridimensional , Humanos , Feminino , Masculino , Recém-Nascido , Nó Atrioventricular/anatomia & histologia , Modelos Cardiovasculares , Nó Sinoatrial/anatomia & histologia , Fascículo Atrioventricular/fisiopatologia , Redes Neurais de Computação , Fatores Sexuais , Fatores Etários , Sistema de Condução Cardíaco/fisiopatologia
20.
Acta Cardiol ; 79(3): 367-373, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38441069

RESUMO

BACKGROUND: Conduction system disorders represent a frequent complication in patients undergoing surgical (surgical aortic valve replacement, SAVR) or percutaneous (transcatheter aortic valve implantation, TAVI) aortic valve replacement. The purpose of this survey was to evaluate experienced operators approach in this clinical condition. METHODS: This survey was independently conducted by the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) and it consisted of 24 questions regarding the respondents' profile, the characteristics of participating centres, and conduction disease management in different scenarios. RESULTS: Fifty-five physicians from 55 Italian arrhythmia centres took part in the survey. Prophylactic pacemaker implantation is rare. In case of persistent complete atrioventricular block (AVB), 49% and 73% respondents wait less than one week before implanting a definitive pacemaker after SAVR and TAVI, respectively. In case of second degree AVB, the respondents wait some days more for definitive implantation. Respondents consider bundle branch blocks, in particular pre-existing left bundle branch block (LBBB), the worst prognostic factors for pacemaker implantation after TAVI. The implanted valve type is considered a relevant element to evaluate. In patients with new-onset LBBB and severe/moderate left ventricular systolic dysfunction, respondents would implant a biventricular pacemaker in 100/55% of cases, respectively. CONCLUSIONS: Waiting time before a definitive pacemaker implantation after aortic valve replacement has reduced compared to the past, and it is anticipated in TAVI vs. SAVR. Bundle branch blocks are considered the worse prognostic factor for pacemaker implantation after TAVI. The type of pacemaker implanted in new-onset LBBB patients without severe left ventricular systolic dysfunction is heterogeneous.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Itália/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Doença do Sistema de Condução Cardíaco/terapia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Valvopatia Aórtica/cirurgia , Inquéritos e Questionários , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Sociedades Médicas , Marca-Passo Artificial , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Feminino , Masculino , Valva Aórtica/cirurgia , Gerenciamento Clínico , Sistema de Condução Cardíaco/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...