Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.619
Filtrar
1.
Mol Biol Rep ; 51(1): 716, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824237

RESUMO

BACKGROUND: Post kala-azar dermal leishmaniasis (PKDL) is a consequential dermal manifestation of visceral leishmaniasis (VL), serving as a parasite reservoir. The traditional diagnostic approach, which requires an invasive skin biopsy is associated with inherent risks and necessitates skilled healthcare practitioners in sterile settings. There is a critical need for a rapid, less invasive method for Leishmania detection. The main objective of this study was to evaluate and compare the diagnostic efficacy of PCR and qPCR in detecting PKDL, utilizing both skin and blood samples and to assess the utility of blood samples for molecular diagnosis. METHODS AND RESULTS: 73 individuals exhibiting clinical symptoms of PKDL and who had tested positive for rK39 rapid diagnostic test (RDT) were enrolled in this study. For the diagnosis of PKDL, both PCR and real-time quantitative PCR (qPCR), employing SYBR Green and TaqMan assays, were performed on blood and skin matched samples. qPCR results using both TaqMan and SYBR Green assay, indicated higher parasite loads in the skin compared to blood, as evident by the Ct values. Importantly, when blood samples were used for PKDL diagnosis by qPCR, an encouraging sensitivity of 69.35% (TaqMan assay) and 79.36% (SYBR Green) were obtained, compared to 8.2% with conventional PCR. CONCLUSION: The findings of the study suggest the potential utility of blood for molecular diagnosis by qPCR, offering a less invasive alternative to skin biopsies in field setting for the early detection of parasitaemia in PKDL patients and effective management and control of the disease.


Assuntos
Leishmaniose Cutânea , Leishmaniose Visceral , Reação em Cadeia da Polimerase em Tempo Real , Humanos , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/sangue , Leishmaniose Visceral/parasitologia , Leishmaniose Cutânea/diagnóstico , Leishmaniose Cutânea/parasitologia , Leishmaniose Cutânea/sangue , Leishmaniose Cutânea/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Masculino , Feminino , Adulto , Adolescente , Pele/parasitologia , Pele/patologia , Sensibilidade e Especificidade , Pessoa de Meia-Idade , Carga Parasitária/métodos , Técnicas de Diagnóstico Molecular/métodos , Adulto Jovem , Criança , DNA de Protozoário/genética , DNA de Protozoário/sangue
2.
Respir Res ; 25(1): 234, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38840154

RESUMO

BACKGROUND: The concurrent circulation of SARS-CoV-2 with other respiratory viruses is unstoppable and represents a new diagnostic reality for clinicians and clinical microbiology laboratories. Multiplexed molecular testing on automated platforms that focus on the simultaneous detection of multiple respiratory viruses in a single tube is a useful approach for current and future diagnosis of respiratory infections in the clinical setting. METHODS: Two time periods were included in the study: from February to April 2022, an early 2022 period, during the gradual lifting of COVID-19 prevention measures in the country, and from October 2022 to April 2023, the 2022/23 respiratory infections season. We analysed a total of 1,918 samples in the first period and 18,131 respiratory samples in the second period using a multiplex molecular assay for the simultaneous detection of Influenza A (Flu-A), Influenza B (Flu-B), Human Respiratory Syncytial Virus (HRSV) and SARS-CoV-2. RESULTS: The results from early 2022 showed a strong dominance of SARS-CoV-2 infections with 1,267/1,918 (66.1%) cases. Flu-A was detected in 30/1,918 (1.6%) samples, HRSV in 14/1,918 (0.7%) samples, and Flu-B in 2/1,918 (0.1%) samples. Flu-A/SARS-CoV-2 co-detections were observed in 11/1,267 (0.9%) samples, and HRSV/SARS-CoV-2 co-detection in 5/1,267 (0.4%) samples. During the 2022/23 winter respiratory season, SARS-CoV-2 was detected in 1,738/18,131 (9.6%), Flu-A in 628/18,131 (3.5%), Flu-B in 106/18,131 (0.6%), and HRSV in 505/18,131 (2.8%) samples. Interestingly, co-detections were present to a similar extent as in early 2022. CONCLUSION: The results show that the multiplex molecular approach is a valuable tool for the simultaneous laboratory diagnosis of SARS-CoV-2, Flu-A/B, and HRSV in hospitalized and outpatients. Infections with Flu-A/B, and HRSV occurred shortly after the COVID-19 control measures were lifted, so a strong reoccurrence of various respiratory infections and co-detections in the post COVID-19 period was to be expected.


Assuntos
COVID-19 , Vírus da Influenza A , Vírus da Influenza B , Influenza Humana , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , SARS-CoV-2 , Humanos , COVID-19/epidemiologia , COVID-19/diagnóstico , Vírus da Influenza B/isolamento & purificação , Vírus da Influenza B/genética , Influenza Humana/epidemiologia , Influenza Humana/diagnóstico , Influenza Humana/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Infecções por Vírus Respiratório Sincicial/epidemiologia , Infecções por Vírus Respiratório Sincicial/diagnóstico , Vírus Sincicial Respiratório Humano/isolamento & purificação , Vírus Sincicial Respiratório Humano/genética , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza A/genética , Masculino , Feminino , Coinfecção/epidemiologia , Coinfecção/diagnóstico , Pessoa de Meia-Idade , Adulto , Técnicas de Diagnóstico Molecular/métodos , Estações do Ano , Idoso
3.
J Med Virol ; 96(6): e29688, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847316

RESUMO

To meet the screening goal of WHO's 90-70-90 strategy aimed at eliminating cervical cancer (CC) by 2030, clinical validation of human papillomavirus (HPV) assays is essential to provide accurate and valid results through fulfilling three criteria of the international validation guidelines (IVGs). Previously, the clinical accuracy of the AmpFire® HPV Screening 16/18/HR assay (AmpFire assay) was reported but reproducibility data are lacking. Here, we aim to evaluate the intra- and inter-laboratory reproducibility of the AmpFire assay. The reproducibility of the isothermal AmpFire assay was assessed using 556 cervical cell samples collected from women attending CC screening and biobanked in a Belgian HPV national reference center. This assay detects HPV16, HPV18, and 12 other high-risk HPV (hrHPV) types (31/33/35/39/45/51/52/56/58/59/66/68) in aggregate. Lower 95% confidence interval bound around the assay's reproducibility should exceed 87%, with κ ≥ 0.50. Additionally, a literature review of the assay's clinical performance was performed. The AmpFire assay showed an excellent intralaboratory (96.4%, 95% CI:94.5-97.8%, κ = 0.920) and interlaboratory (95.3%, 95% CI:93.2-96.9%, κ = 0.897) reproducibility. One study demonstrated noninferior sensitivity of a prototype AmpFire assay targeting 15 hrHPV types (including HPV53) to detect CIN2+. However, clinical specificity became similar to the comparator after removing HPV53 from analyses. The low-cost and easy-to-use AmpFire assay presents excellent reproducibility and-after removing HPV53 from the targeted types-fulfills also clinical accuracy requirements. Inclusion of HPV53, which is not recognized as carcinogenic, comprises clinical specificity of screening assays.


Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Humanos , Reprodutibilidade dos Testes , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/virologia , Feminino , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/virologia , Papillomaviridae/isolamento & purificação , Bélgica , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/normas , Adulto , Sensibilidade e Especificidade , Pessoa de Meia-Idade , Técnicas de Diagnóstico Molecular/normas , Técnicas de Diagnóstico Molecular/métodos , Colo do Útero/virologia
4.
Surg Pathol Clin ; 17(2): 307-320, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38692813

RESUMO

Adoption of molecular testing in lung cancer is increasing. Molecular testing for staging and prediction of response for targeted therapy remain the main indications, and although utilization of blood-based testing for tumor is growing, the use of the diagnostic cytology and tissue specimens is equally important. The pathologist needs to optimize reflex testing, incorporate stage-based algorithms, and understand types of tests for timely and complete assessment in the majority of cases. When tissue is limited, testing should capture the most frequent alterations to maximize the yield of what are largely mutually exclusive alterations, avoiding the need for repeat biopsy.


Assuntos
Biomarcadores Tumorais , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/diagnóstico , Biomarcadores Tumorais/genética , Técnicas de Diagnóstico Molecular , Estadiamento de Neoplasias , Guias de Prática Clínica como Assunto , Mutação , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico
5.
PLoS Negl Trop Dis ; 18(5): e0011637, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38713648

RESUMO

BACKGROUND: Diagnosis of visceral leishmaniasis (VL) in resource-limited endemic regions is currently based on serological testing with rK39 immunochromatographic tests (ICTs). However, rK39 ICT frequently has suboptimal diagnostic accuracy. Furthermore, treatment monitoring and detection of VL relapses is reliant on insensitive and highly invasive tissue aspirate microscopy. Miniature direct-on-blood PCR nucleic acid lateral flow immunoassay (mini-dbPCR-NALFIA) is an innovative and user-friendly molecular tool which does not require DNA extraction and uses a lateral flow strip for result read-out. This assay could be an interesting candidate for more reliable VL diagnosis and safer test of cure at the point of care. METHODOLOGY/PRINCIPLE FINDINGS: The performance of mini-dbPCR-NALFIA for diagnosis of VL in blood was assessed in a laboratory evaluation and compared with the accuracy of rK39 ICTs Kalazar Detect in Spain and IT LEISH in East Africa. Limit of detection of mini-dbPCR-NALFIA was 650 and 500 parasites per mL of blood for Leishmania donovani and Leishmania infantum, respectively. In 146 blood samples from VL-suspected patients from Spain, mini-dbPCR-NALFIA had a sensitivity of 95.8% and specificity 97.2%, while Kalazar Detect had a sensitivity of 71.2% and specificity of 94.5%, compared to a nested PCR reference. For a sample set from 58 VL patients, 10 malaria patients and 68 healthy controls from Ethiopia and Kenya, mini-dbPCR-NALFIA had a pooled sensitivity of 87.9% and pooled specificity of 100% using quantitative PCR as reference standard. IT LEISH sensitivity and specificity in the East African samples were 87.9% and 97.4%, respectively. CONCLUSIONS/SIGNIFICANCE: Mini-dbPCR-NALFIA is a promising tool for simplified molecular diagnosis of VL and follow-up of treated patients in blood samples. Future studies should evaluate its use in endemic, resource-limited settings, where mini-dbPCR-NALFIA may provide an accurate and versatile alternative to rK39 ICTs and aspirate microscopy.


Assuntos
Leishmania donovani , Leishmaniose Visceral , Sensibilidade e Especificidade , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/parasitologia , Humanos , Leishmania donovani/genética , Leishmania donovani/isolamento & purificação , Imunoensaio/métodos , Leishmania infantum/genética , Leishmania infantum/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Espanha , Técnicas de Diagnóstico Molecular/métodos , Feminino , Masculino , Adulto , Adolescente , Criança , Adulto Jovem , Pessoa de Meia-Idade , África Oriental , DNA de Protozoário/genética , DNA de Protozoário/sangue , Pré-Escolar
6.
Anal Chim Acta ; 1307: 342560, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719398

RESUMO

BACKGROUND: Point-of-care (POC) nucleic acid amplification tests (NAAT) can significantly expand testing coverage, which is critical for infectious disease diagnostics and monitoring. The development of various isothermal amplification techniques greatly simplifies NAATs, but the cumbersome nucleic acid extraction step remains a bottleneck for the POC. Alternatively, extraction-free amplification, where crude samples are directly added into the assay, substantially simplifies the workflow. However, sample dilution is often needed in extraction-free amplification to reduce assay inhibition from sample matrices. Since NAATs are typically run at small volumes around 20 µL, the input sample quantity is therefore limited, resulting in an inevitable sensitivity loss. RESULTS: Here we explore the potential to perform isothermal amplification in larger reaction volumes to accommodate larger sample quantities, thereby improving sensitivity in extraction-free amplification. We demonstrated the approach by developing large-volume reverse transcription loop-mediated isothermal amplification (RT-LAMP) for HIV RNA detection from fingerstick plasma. We found that LAMP at reaction volumes up to 1 mL maintained the same performance. We then identified plasma dilution conditions needed to maintain the limit of detection in RT-LAMP. Subsequently, using inactivated HIV virus, we showed the successful detection of 24 HIV RNA copies in a 500 µL RT-LAMP reaction in the presence of 20 µL plasma (fingerstick volumes), translating to a viral load of 1200 copies per mL. To reduce the increased reagent cost with expanded reaction volumes, we further identified lower-cost reagents with maintained assay performance. Moreover, we showed that large-volume LAMP, compared to 20 µL reactions, could tolerate higher concentrations of various inhibitors in the sample, such as albumin and GuSCN. SIGNIFICANCE AND NOVELTY: NAATs are conventionally conducted at small reaction volumes. Here we demonstrated that LAMP can be run at large reaction volumes (over 100 µL) with maintained assay performance, allowing sample inhibition to be mitigated while accommodating larger sample quantities. The same strategy of expanding reaction volumes could be applied to other isothermal amplification methods and various POC applications, to streamline test workflows and/or improve assay sensitivity.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , RNA Viral , Técnicas de Amplificação de Ácido Nucleico/métodos , Humanos , RNA Viral/sangue , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/genética , HIV-1/isolamento & purificação , Limite de Detecção , Técnicas de Diagnóstico Molecular
7.
Mycopathologia ; 189(3): 38, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38704795

RESUMO

OBJECTIVES: To describe the epidemiology of Pneumocystis jirovecii pneumonia and colonization diagnosed by next-generation sequencing (NGS) and explore the usefulness of the number of P. jirovecii sequence reads for the diagnosis of P. jirovecii pneumonia. METHODS: We examined the NGS results for P. jirovecii in respiratory samples collected from patients and analysed their clinical, radiological and microbiological characteristics. RESULTS: Among 285 respiratory samples collected over a 12-month period (January to December 2022), P. jirovecii sequences were detected in 56 samples from 53 patients. Fifty (94.3%) of the 53 patients were HIV-negative. Following our case definitions, 37 (69.8%) and 16 (30.2%) of the 53 patients had P. jirovecii infection and colonization respectively. P. jirovecii infection was associated with presence of underlying disease with immunosuppression (94.6% vs 18.8%, P < 0.05), positive serum 1,3-ß-D-glucan (41.2% vs 0%, P < 0.01) and higher number of P. jirovecii sequence reads (P < 0.005). In contrast, P. jirovecii colonization was associated with the male sex (93.8% vs 54.1%, P < 0.01), another definitive infectious disease diagnosis of the respiratory tract (43.8% vs 2.7%, P < 0.001) and higher survival (100% vs 67.6%, P < 0.01). Although P. jirovecii pneumonia was associated with higher number of P. jirovecii reads in respiratory samples, only a sensitivity of 82.14% and a specificity of 68.75% could be achieved. CONCLUSION: Detection of P. jirovecii sequences in respiratory samples has to be interpreted discreetly. A combination of clinical, radiological and laboratory findings is still the most crucial in determining whether a particular case is genuine P. jirovecii pneumonia.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala , Pneumocystis carinii , Pneumonia por Pneumocystis , Humanos , Pneumonia por Pneumocystis/diagnóstico , Pneumonia por Pneumocystis/microbiologia , Masculino , Pneumocystis carinii/genética , Pneumocystis carinii/isolamento & purificação , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Idoso de 80 Anos ou mais , Sistema Respiratório/microbiologia , Adulto Jovem , Técnicas de Diagnóstico Molecular/métodos
8.
Adv Exp Med Biol ; 1451: 253-271, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38801583

RESUMO

An outbreak of monkeypox (Mpox) was reported in more than 40 countries in early 2022. Accurate diagnosis of Mpox can be challenging, but history, clinical findings, and laboratory diagnosis can establish the diagnosis. The pre-analytic phase of testing includes collecting, storing, and transporting specimens. It is advised to swab the lesion site with virus transport medium (VTM) containing Dacron or polyester flock swabs from two different sites. Blood, urine, and semen samples may also be used. Timely sampling is necessary to obtain a sufficient amount of virus or antibodies. The analytical phase of infectious disease control involves diagnostic tools to determine the presence of the virus. While polymerase chain reaction (PCR) is the gold standard for detecting Mpox, genome sequencing is for identifying new or modified viruses. As a complement to these methods, isothermal amplification methods have been designed. ELISA assays are also available for the determination of antibodies. Electron microscopy is another effective diagnostic method for tissue identification of the virus. Wastewater fingerprinting provides some of the most effective diagnostic methods for virus identification at the community level. The advantages and disadvantages of these methods are further discussed. Post-analytic phase requires proper interpretation of test results and the preparation of accurate patient reports that include relevant medical history, clinical guidelines, and recommendations for follow-up testing or treatment.


Assuntos
Mpox , Humanos , Mpox/diagnóstico , Mpox/virologia , Mpox/epidemiologia , Monkeypox virus/genética , Monkeypox virus/isolamento & purificação , Ensaio de Imunoadsorção Enzimática/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase/métodos , Manejo de Espécimes/métodos , Técnicas de Laboratório Clínico/métodos
9.
PLoS One ; 19(5): e0302783, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753660

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) is one of the most serious and debilitating complications that can occur after total joint arthroplasty. Therefore, early diagnosis and appropriate treatment are important for a good prognosis. Recently, molecular diagnostic methods have been widely used to detect the causative microorganisms of PJI sensitively and rapidly. The Multiplex Loop-Mediated Isothermal Amplification (LAMP) method eliminates the complex temperature cycling and delays caused by temperature transitions seen in polymerase chain reaction (PCR) methods, making it faster and easier to perform compared to PCR-based assays. Therefore, this study developed a multiplex LAMP assay for diagnosing bacterial PJI using LAMP technology and evaluated its analytical and clinical performance. METHODS: We developed a multiplex LAMP assay for the detection of five bacteria: Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus agalactiae, Pseudomonas aeruginosa, and Escherichia coli, frequently observed to be the causative agents of PJI. The method of analytical sensitivity and cross-reactivity were determined by spiking standard strains into the joint synovial fluid. The analytical sensitivity of the multiplex LAMP assay was compared with that of a quantitative real-time PCR (qPCR) assay. Clinical performance was evaluated using 20 joint synovial fluid samples collected from patients suspected of having bacterial PJI. RESULTS: The analytical sensitivity of the gram-positive bacterial multiplex LAMP assay and qPCR were 105/104 CFU/mL, 103/103 CFU/mL, and 105/104 CFU/mL against S. agalactiae, S. epidermidis, and S. aureus, respectively. For P. aeruginosa and E. coli, the analytical sensitivity of the multiplex LAMP and qPCR assays were 105/104 and 106/104 CFU/mL, respectively. The multiplex LAMP assay detects target bacteria without cross-reacting with other bacteria, and exhibited 100% sensitivity and specificity in clinical performance evaluation. CONCLUSIONS: This multiplex LAMP assay can rapidly detect five high-prevalence bacterial species causing bacterial PJI, with excellent sensitivity and specificity, in less than 1 h, and it may be useful for the early diagnosis of PJI.


Assuntos
Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Infecções Relacionadas à Prótese , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , Staphylococcus epidermidis/isolamento & purificação , Staphylococcus epidermidis/genética , Líquido Sinovial/microbiologia , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , Staphylococcus aureus/isolamento & purificação , Staphylococcus aureus/genética
10.
J Med Virol ; 96(5): e29686, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38767142

RESUMO

Comparison of diagnostic accuracy for commercial hepatitis C virus (HCV) genotyping (Abbott RealTime HCV Genotyping II, Roche Cobas Genotyping) and investigational Abbott HCV Genotype plus RUO assays designed to discriminate genotype (GT)-1a, 1b or 6 in cases of ambiguous GT from the Abbott commercial assay remains limited. 743 HCV-viremic samples were subjected to analysis using Abbott and Roche commercial as well as Abbott HCV Genotype plus RUO assays. Next-generation sequencing (NGS) targeting core region was employed as the reference standard. Diagnostic accuracy was reported as the number of participants (percentages) along with 95% confidence intervals (CIs). Using NGS, 741 samples (99.7%) yielded valid genotyping results. The diagnostic accuracies were 97.6% (95% CI: 96.1%-98.5%) and 95.3% (95% CI: 93.4%-96.6%) using Abbott and Roche commercial assays (p = 0.0174). Abbott commercial assay accurately diagnosed HCV GT-6a and 6w, whereas Roche commercial assay accurately diagnosed HCV GT-6a. Both assays demonstrated low accuracies for HCV GT-6b, 6e, 6g, and 6n. Abbott HCV Genotype plus RUO assay discriminated 13 of the 14 samples (92.9%; 95% CI: 64.2%-99.6%) that yielded ambiguous GT. Both assays were capable of diagnosing mixed HCV infections when the minor genotype comprised >8.4% of the viral load. The diagnostic performance of commercial HCV genotyping assays is commendable. Abbott assay demonstrated superior performance compared to Roche assay in diagnosing HCV GT-6. Abbott HCV Genotype plus RUO assay aids in discriminating ambiguous GT. Both commercial assays are proficient in diagnosing mixed HCV infections at a cut-off viral load of 8.4% in minor genotype.


Assuntos
Genótipo , Técnicas de Genotipagem , Hepacivirus , Hepatite C , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Hepacivirus/genética , Hepacivirus/classificação , Hepacivirus/isolamento & purificação , Técnicas de Genotipagem/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Hepatite C/diagnóstico , Hepatite C/virologia , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , Kit de Reagentes para Diagnóstico/normas , Feminino , Masculino , Pessoa de Meia-Idade , Adulto
11.
Biochem Biophys Res Commun ; 717: 150028, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38714016

RESUMO

Mycoplasma pneumoniae (MP),as the most commonly infected respiratory pathogen in community-acquired pneumonia in preschool children,has becoming a prominent factor affecting children's respiratory health.Currently, there is a lack of easy, rapid, and accurate laboratory testing program for MP infection, which causes comparatively difficulty for clinical diagnostic.Here,we utilize loop-mediated isothermal amplification (LAMP) to amplify and characterize the P1 gene of MP, combined with nucleic acid lateral flow (NALF) for fast and visuallized detection of MP.Furthermore, we evaluated and analyzed the sensitivity, specificity and methodological consistency of the method.The results showed that the limit of detection(LoD) of MP-LAMP-NALF assay was down to 100 copys per reaction and there was no cross-reactivity with other pathogens infected the respiratory system. The concordance rate between MP-LAMP-NALF assay with quantitative real-time PCR was 94.3 %,which exhibiting excellent testing performance.We make superior the turnaround time of the MP-LAMP-NALF assay, which takes only about 50 min. In addition, there is no need for precision instruments and no restriction on the laboratory site.Collectively, LAMP-NALF assay targeting the P1 gene for Mycoplasma pneumoniae detection was a easy, precise and visual test which could be widely applied in outpatient and emergency departments or primary hospitals.When further optimized, it could be used as "point-of-care testing" of pathogens or multiple testing for pathogens.


Assuntos
Técnicas de Diagnóstico Molecular , Mycoplasma pneumoniae , Técnicas de Amplificação de Ácido Nucleico , Pneumonia por Mycoplasma , Mycoplasma pneumoniae/genética , Mycoplasma pneumoniae/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Humanos , Pneumonia por Mycoplasma/diagnóstico , Pneumonia por Mycoplasma/microbiologia , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade , Limite de Detecção , DNA Bacteriano/genética
12.
Ann Med ; 56(1): 2353893, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38753424

RESUMO

BACKGROUND: One of the ailments with the greatest fatality rates in the 21st century is cancer. Globally, molecular methods are widely employed to treat cancer-related disorders, and the body of research on this subject is growing yearly. A thorough and critical summary of the data supporting molecular methods for illnesses linked to cancer is required. OBJECTIVE: In order to guide clinical practice and future research, it is important to examine and summarize the systematic reviews (SRs) that evaluate the efficacy and safety of molecular methods for disorders associated to cancer. METHODS: We developed a comprehensive search strategy to find relevant articles from electronic databases like PubMed, Google Scholar, Web of Science (WoS), or Scopus. We looked through the literature and determined which diagnostic methods in cancer genetics were particularly reliable. We used phrases like 'cancer genetics', genetic susceptibility, Hereditary cancer, cancer risk assessment, 'cancer diagnostic tools', cancer screening', biomarkers, and molecular diagnostics, reviews and meta-analyses evaluating the efficacy and safety of molecular therapies for cancer-related disorders. Research that only consider treatment modalities that don't necessitate genetic or molecular diagnostics fall under the exclusion criteria. RESULTS: The results of this comprehensive review clearly demonstrate the transformative impact of molecular methods in the realm of cancer genetics.This review underscores how these technologies have empowered researchers and clinicians to identify and understand key genetic alterations that drive malignancy, ranging from point mutations to structural variations. Such insights are instrumental in pinpointing critical oncogenic drivers and potential therapeutic targets, thus opening the door for methods in precision medicine that can significantly improve patient outcomes. LIMITATION: The search does not specify a timeframe for publication inclusion, it may have missed recent advancements or changes in the field's landscape of molecular methods for cancer. As a result, it may not have included the most recent developments in the field. CONCLUSION: After conducting an in-depth study on the molecular methods in cancer genetics, it is evident that these cutting-edge technologies have revolutionized the field of oncology, providing researchers and clinicians with powerful tools to unravel the complexities of cancer at the genetic level. The integration of molecular methods techniques has not only enhanced our understanding of cancer etiology, progression, and treatment response but has also opened new avenues for personalized medicine and targeted therapies, leading to improved patient outcomes.


Assuntos
Biomarcadores Tumorais , Neoplasias , Humanos , Neoplasias/genética , Neoplasias/diagnóstico , Biomarcadores Tumorais/genética , Técnicas de Diagnóstico Molecular/métodos , Detecção Precoce de Câncer/métodos , Predisposição Genética para Doença , Medicina de Precisão/métodos
13.
Acta Trop ; 255: 107249, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38740319

RESUMO

BACKGROUND: Natural human infections by Plasmodium cynomolgi and P. inui have been reported recently and gain the substantial attention from Southeast Asian countries. Zoonotic transmission of non-human malaria parasites to humans from macaque monkeys occurred through the bites of the infected mosquitoes. The objective of this study is to establish real-time fluorescence loop-mediated isothermal amplification (LAMP) assays for the detection of zoonotic malaria parasites by combining real-time fluorescent technology with the isothermal amplification technique. METHODS: By using 18S rRNA as the target gene, the primers for P. cynomolgi, P. coatneyi and P. inui were newly designed in the present study. Four novel real-time fluorescence LAMP assays were developed for the detection of P. cynomolgi, P. coatneyi, P. inui and P. knowlesi. The entire amplification process was completed in 60 min, with the assays performed at 65 °C. By using SYTO-9 as the nucleic acid intercalating dye, the reaction was monitored via real-time fluorescence signal. RESULTS: There was no observed cross-reactivity among the primers from different species. All 70 field-collected monkey samples were successfully amplified by real-time fluorescence LAMP assays. The detection limit for P. cynomolgi, P. coatneyi and P. knowlesi was 5 × 109 copies/µL. Meanwhile, the detection limit of P. inui was 5 × 1010 copies/µL. CONCLUSION: This is the first report of the detection of four zoonotic malaria parasites by real-time fluorescence LAMP approaches. It is an effective, rapid and simple-to-use technique. This presented platform exhibits considerable potential as an alternative detection for zoonotic malaria parasites.


Assuntos
Malária , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Plasmodium , RNA Ribossômico 18S , Sensibilidade e Especificidade , Zoonoses , Animais , Técnicas de Amplificação de Ácido Nucleico/métodos , Malária/diagnóstico , Malária/parasitologia , Malária/veterinária , RNA Ribossômico 18S/genética , Técnicas de Diagnóstico Molecular/métodos , Plasmodium/genética , Plasmodium/isolamento & purificação , Plasmodium/classificação , Zoonoses/parasitologia , Zoonoses/diagnóstico , Humanos , Primers do DNA/genética , Fluorescência , Macaca/parasitologia , Doenças dos Macacos/parasitologia , Doenças dos Macacos/diagnóstico
14.
Biosensors (Basel) ; 14(5)2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38785702

RESUMO

Legionella pneumophila has been pinpointed by the World Health Organization as the highest health burden of all waterborne pathogens in the European Union and is responsible for many disease outbreaks around the globe. Today, standard analysis methods (based on bacteria culturing onto agar plates) need several days (~12) in specialized analytical laboratories to yield results, not allowing for timely actions to prevent outbreaks. Over the last decades, great efforts have been made to develop more efficient waterborne pathogen diagnostics and faster analysis methods, requiring further advancement of microfluidics and sensors for simple, rapid, accurate, inexpensive, real-time, and on-site methods. Herein, a lab-on-a-chip device integrating sample preparation by accommodating bacteria capture, lysis, and DNA isothermal amplification with fast (less than 3 h) and highly sensitive, colorimetric end-point detection of L. pneumophila in water samples is presented, for use at the point of need. The method is based on the selective capture of viable bacteria on on-chip-immobilized and -lyophilized antibodies, lysis, the loop-mediated amplification (LAMP) of DNA, and end-point detection by a color change, observable by the naked eye and semiquantified by computational image analysis. Competitive advantages are demonstrated, such as low reagent consumption, portability and disposability, color change, storage at RT, and compliance with current legislation.


Assuntos
Colorimetria , Dispositivos Lab-On-A-Chip , Legionella pneumophila , Técnicas de Amplificação de Ácido Nucleico , Legionella pneumophila/isolamento & purificação , Humanos , Microbiologia da Água , DNA Bacteriano/análise , Técnicas Biossensoriais , Técnicas de Diagnóstico Molecular
15.
Biosensors (Basel) ; 14(5)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38785731

RESUMO

Loop-mediated isothermal amplification (LAMP) technology is extensively utilized for the detection of infectious diseases owing to its rapid processing and high sensitivity. Nevertheless, conventional LAMP signaling methods frequently suffer from a lack of sequence specificity. This study integrates a triplex-forming oligonucleotide (TFO) probe into the LAMP process to enhance sequence specificity. This TFO-LAMP technique was applied for the detection of Group B Streptococcus (GBS). The TFO probe is designed to recognize a specific DNA sequence, termed the TFO targeting sequence (TTS), within the amplified product, facilitating detection via fluorescent instrumentation or lateral flow biosensors. A screening method was developed to identify TFO sequences with high affinity to integrate TFO into LAMP, subsequently incorporating a selected TTS into an LAMP primer. In the TFO-LAMP assay, a FAM-labeled TFO is added to target the TTS. This TFO can be captured by an anti-FAM antibody on lateral flow test strips, thus creating a nucleic acid testing biosensor. The efficacy of the TFO-LAMP assay was confirmed through experiments with specimens spiked with varying concentrations of GBS, demonstrating 85% sensitivity at 300 copies and 100% sensitivity at 30,000 copies. In conclusion, this study has successfully developed a TFO-LAMP technology that offers applicability in lateral flow biosensors and potentially other biosensor platforms.


Assuntos
Técnicas Biossensoriais , Técnicas de Amplificação de Ácido Nucleico , Oligonucleotídeos , Streptococcus/genética , Streptococcus/isolamento & purificação , Humanos , DNA Bacteriano/análise , Técnicas de Diagnóstico Molecular
16.
Cells ; 13(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38786028

RESUMO

Zika (ZIKV) and Chikungunya (CHIKV) viruses are mosquito-transmitted infections, or vector-borne pathogens, that emerged a few years ago. Reliable diagnostic tools for ZIKV and CHIKV-inexpensive, multiplexed, rapid, highly sensitive, and specific point-of-care (POC) systems-are vital for appropriate risk management and therapy. We recently studied a detection system with great success in Mexico (Villahermosa, state of Tabasco), working with human sera from patients infected with those viruses. The research conducted in Mexico validated the efficacy of a novel two-step rapid isothermal amplification technique (RAMP). This approach, which encompasses recombinase polymerase amplification (RPA) followed by loop-mediated isothermal amplification (LAMP), had been previously established in the lab using lab-derived Zika (ZIKV) and Chikungunya (CHIKV) viruses. Crucially, our findings confirmed that this technique is also effective when applied to human sera samples collected from locally infected individuals in Mexico.


Assuntos
Vírus Chikungunya , Técnicas de Amplificação de Ácido Nucleico , Infecção por Zika virus , Zika virus , Humanos , Zika virus/genética , Zika virus/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Vírus Chikungunya/genética , Vírus Chikungunya/isolamento & purificação , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/virologia , Infecção por Zika virus/sangue , Febre de Chikungunya/diagnóstico , Febre de Chikungunya/virologia , Febre de Chikungunya/sangue , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/genética , RNA Viral/sangue , México , Sensibilidade e Especificidade , Vírus de RNA/genética , Vírus de RNA/isolamento & purificação
17.
ACS Sens ; 9(5): 2695-2702, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38747895

RESUMO

Quantitative nucleic acid amplification tests are of great importance for diagnostics, but current approaches require complex and costly optical setups that limit their nonlaboratory applications. Herein we describe the implementation of a microfluidics platform that can perform binary DNA-amplification-activated droplet sorting. The digital sort-enabled counting (DISCO) platform enables label-free absolute quantification of the nucleic acid. This is achieved by provoking a pH change in droplets through a loop-mediated isothermal amplification (LAMP) reaction, followed by using sorting by interfacial tension (SIFT) to direct positive and negative droplets to different outlets. With the use of on-chip electrodes at both outlets, we demonstrate that the digital electrical counting of target DNA and RNA can be realized. DISCO is a promising approach for realizing sensitive nucleic acid quantification in point-of-care settings.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Técnicas de Amplificação de Ácido Nucleico/métodos , DNA/análise , DNA/química , Dispositivos Lab-On-A-Chip , RNA/análise , Eletrodos , Técnicas Eletroquímicas/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Diagnóstico Molecular
18.
Anal Chim Acta ; 1311: 342720, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38816155

RESUMO

BACKGROUND: The monkeypox virus (MPXV) is a linear double-stranded DNA virus with a large genome that causes tens of thousands of infections and hundreds of deaths in at least 40 countries and regions worldwide. Therefore, timely and accurate diagnostic testing could be an important measure to prevent the ongoing spread of MPXV and widespread epidemics. RESULTS: Here, we designed multiple sets of primers for the target region of MPXV for loop-mediated isothermal amplification (LAMP) detection and identified the optimal primer set. Then, the specificity in fluorescent LAMP detection was verified using the plasmids containing the target gene, pseudovirus and other DNA/RNA viruses. We also evaluated the sensitivity of the colorimetric LAMP detection system using the plasmid and pseudovirus samples, respectively. Besides, we used monkeypox pseudovirus to simulate real samples for detection. Subsequent to the establishment and introduction of a magnetic beads (MBs)-based nucleic acid extraction technique, an integrated device was developed, characterized by rapidity, high sensitivity, and remarkable specificity. This portable system demonstrated a visual detection limit of 137 copies/mL, achieving sample-to-answer detection within 1 h. SIGNIFICANCE: The device has the advantages of integration, simplicity, miniaturization, and visualization, which help promote the realization of accurate, rapid, portable, and low-cost testing. Meanwhile, this platform could facilitate efficient, cost-effective and easy-operable point-of-care testing (POCT) in diverse resource-limited settings in addition to the laboratory.


Assuntos
Colorimetria , Monkeypox virus , Técnicas de Amplificação de Ácido Nucleico , Colorimetria/métodos , Colorimetria/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Monkeypox virus/genética , Monkeypox virus/isolamento & purificação , Limite de Detecção , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentação
19.
Front Cell Infect Microbiol ; 14: 1391943, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38808061

RESUMO

Blastocystis spp. is a ubiquitous protozoon in the intestinal tract of human and many animals. Microscopic examination is the main method of clinical diagnosis for Blastocystis spp., which is prone to false negative. A simple and rapid diagnosis of Blastocystis spp. infection is an important step to prevent and control blastocystosis. Here, a recombinase polymerase amplification-lateral flow dipstick (RPA-LFD) assay was developed for rapid visual detection of Blastocystis spp. DNA amplification could be performed within 18 min at 37°C. The minimum DNA detection limit was 1 pg/µL, and there was no cross-reactivity with 12 other non-target pathogens, which was consistent with the sensitivity of conventional PCR (cPCR). Furthermore, 56 fecal samples from the Third Affiliated Hospital of Xinxiang Medical University were tested using RPA and cPCR methods respectively, and the results were completely consistent. The results show that RPA-LFD method has high accuracy and visual results, which provides a new choice for the differential diagnosis and rapid field detection of Blastocystis spp.


Assuntos
Infecções por Blastocystis , Blastocystis , DNA de Protozoário , Fezes , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e Especificidade , Blastocystis/genética , Blastocystis/isolamento & purificação , Humanos , Infecções por Blastocystis/diagnóstico , Infecções por Blastocystis/parasitologia , Técnicas de Amplificação de Ácido Nucleico/métodos , Fezes/parasitologia , Técnicas de Diagnóstico Molecular/métodos , DNA de Protozoário/genética , Recombinases/metabolismo , Recombinases/genética
20.
Int J Mol Sci ; 25(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38791224

RESUMO

Cotton Verticillium wilt is mainly caused by the fungus Verticillium dahliae, which threatens the production of cotton. Its pathogen can survive in the soil for several years in the form of microsclerotia, making it a destructive soil-borne disease. The accurate, sensitive, and rapid detection of V. dahliae from complex soil samples is of great significance for the early warning and management of cotton Verticillium wilt. In this study, we combined the loop-mediated isothermal amplification (LAMP) with CRISPR/Cas12a technology to develop an accurate, sensitive, and rapid detection method for V. dahliae. Initially, LAMP primers and CRISPR RNA (crRNA) were designed based on a specific DNA sequence of V. dahliae, which was validated using several closely related Verticillium spp. The lower detection limit of the LAMP-CRISPR/Cas12a combined with the fluorescent visualization detection system is approximately ~10 fg/µL genomic DNA per reaction. When combined with crude DNA-extraction methods, it is possible to detect as few as two microsclerotia per gram of soil, with the total detection process taking less than 90 min. Furthermore, to improve the method's user and field friendliness, the field detection results were visualized using lateral flow strips (LFS). The LAMP-CRISPR/Cas12a-LFS system has a lower detection limit of ~1 fg/µL genomic DNA of the V. dahliae, and when combined with the field crude DNA-extraction method, it can detect as few as six microsclerotia per gram of soil, with the total detection process taking less than 2 h. In summary, this study expands the application of LAMP-CRISPR/Cas12a nucleic acid detection in V. dahliae and will contribute to the development of field-deployable diagnostic productions.


Assuntos
Sistemas CRISPR-Cas , Técnicas de Amplificação de Ácido Nucleico , Doenças das Plantas , Microbiologia do Solo , Técnicas de Amplificação de Ácido Nucleico/métodos , Doenças das Plantas/microbiologia , Ascomicetos/genética , Ascomicetos/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Gossypium/microbiologia , DNA Fúngico/genética , DNA Fúngico/isolamento & purificação , Verticillium/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...