Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.160
Filtrar
1.
Scand Cardiovasc J ; 58(1): 2347297, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38695238

RESUMO

Objectives. Atrial fibrillation is a common arrhythmia in patients with ischemic heart disease. This study aimed to determine the cumulative incidence of new-onset atrial fibrillation after percutaneous coronary intervention or coronary artery bypass grafting surgery during 30 days of follow-up. Design. This was a prospective multi-center cohort study on atrial fibrillation incidence following percutaneous coronary intervention or coronary artery bypass grafting for stable angina or non-ST-elevation acute coronary syndrome. Heart rhythm was monitored for 30 days postoperatively by in-hospital telemetry and handheld thumb ECG recordings after discharge were performed. The primary endpoint was the cumulative incidence of atrial fibrillation 30 days after the index procedure. Results. In-hospital atrial fibrillation occurred in 60/123 (49%) coronary artery bypass graft and 0/123 percutaneous coronary intervention patients (p < .001). The cumulative incidence of atrial fibrillation after 30 days was 56% (69/123) of patients undergoing coronary artery bypass grafting and 2% (3/123) of patients undergoing percutaneous coronary intervention (p < .001). CABG was a strong predictor for atrial fibrillation compared to PCI (OR 80.2, 95% CI 18.1-354.9, p < .001). Thromboembolic stroke occurred in-hospital in one coronary artery bypass graft patient unrelated to atrial fibrillation, and at 30 days in two additional patients, one in each group. There was no mortality. Conclusion. New-onset atrial fibrillation during 30 days of follow-up was rare after percutaneous coronary intervention but common after coronary artery bypass grafting. A prolonged uninterrupted heart rhythm monitoring strategy identified additional patients in both groups with new-onset atrial fibrillation after discharge.


Assuntos
Fibrilação Atrial , Ponte de Artéria Coronária , Intervenção Coronária Percutânea , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Intervenção Coronária Percutânea/efeitos adversos , Masculino , Incidência , Feminino , Ponte de Artéria Coronária/efeitos adversos , Idoso , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico , Frequência Cardíaca , Angina Estável/diagnóstico , Angina Estável/fisiopatologia , Angina Estável/epidemiologia , Angina Estável/cirurgia , Angina Estável/terapia , Medição de Risco , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/epidemiologia , Telemetria
2.
J Toxicol Sci ; 49(5): 231-240, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38692910

RESUMO

Drug-induced convulsions are a major challenge to drug development because of the lack of reliable biomarkers. Using machine learning, our previous research indicated the potential use of an index derived from heart rate variability (HRV) analysis in non-human primates as a biomarker for convulsions induced by GABAA receptor antagonists. The present study aimed to explore the application of this methodology to other convulsants and evaluate its specificity by testing non-convulsants that affect the autonomic nervous system. Telemetry-implanted males were administered various convulsants (4-aminopyridine, bupropion, kainic acid, and ranolazine) at different doses. Electrocardiogram data gathered during the pre-dose period were employed as training data, and the convulsive potential was evaluated using HRV and multivariate statistical process control. Our findings show that the Q-statistic-derived convulsive index for 4-aminopyridine increased at doses lower than that of the convulsive dose. Increases were also observed for kainic acid and ranolazine at convulsive doses, whereas bupropion did not change the index up to the highest dose (1/3 of the convulsive dose). When the same analysis was applied to non-convulsants (atropine, atenolol, and clonidine), an increase in the index was noted. Thus, the index elevation appeared to correlate with or even predict alterations in autonomic nerve activity indices, implying that this method might be regarded as a sensitive index to fluctuations within the autonomic nervous system. Despite potential false positives, this methodology offers valuable insights into predicting drug-induced convulsions when the pharmacological profile is used to carefully choose a compound.


Assuntos
4-Aminopiridina , Frequência Cardíaca , Aprendizado de Máquina , Convulsões , Animais , Masculino , Convulsões/induzido quimicamente , Frequência Cardíaca/efeitos dos fármacos , 4-Aminopiridina/efeitos adversos , Ácido Caínico/toxicidade , Convulsivantes/toxicidade , Ranolazina , Bupropiona/toxicidade , Bupropiona/efeitos adversos , Eletrocardiografia/efeitos dos fármacos , Relação Dose-Resposta a Droga , Sistema Nervoso Autônomo/efeitos dos fármacos , Sistema Nervoso Autônomo/fisiopatologia , Telemetria , Biomarcadores
3.
Acute Med ; 23(1): 24-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38619167

RESUMO

BACKGROUND AND AIMS: Despite published guidelines, telemetry use is inappropriate in 25-43% of cases. This impacts patient safety and telemetry effectiveness. QI methodology was used to review telemetry in a hospital acute medical unit with the aim of reducing inappropriate use and addressing alarm fatigue. METHODS: A 'Telemetry Indication Form' was created. Eight weeks of baseline data was collated before introducing the 'Indication Form'. Four plan-do-study-act cycles were conducted. At each cycle, data was analysed using statistical process control charts. RESULTS: Inappropriate telemetry use significantly reduced from 32% to 4%. Total telemetry use also fell. Unfortunately, interventions to address alarm rates did not result in significant reduction in false alarms. CONCLUSIONS: A 'Telemetry Indication Form' has significant potential to improve patient safety through reducing inappropriate use.


Assuntos
Unidades Hospitalares , Telemetria , Humanos
4.
PLoS One ; 19(4): e0300013, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598444

RESUMO

Hyperspectral Images (HSI) classification is a challenging task due to a large number of spatial-spectral bands of images with high inter-similarity, extra variability classes, and complex region relationships, including overlapping and nested regions. Classification becomes a complex problem in remote sensing images like HSIs. Convolutional Neural Networks (CNNs) have gained popularity in addressing this challenge by focusing on HSI data classification. However, the performance of 2D-CNN methods heavily relies on spatial information, while 3D-CNN methods offer an alternative approach by considering both spectral and spatial information. Nonetheless, the computational complexity of 3D-CNN methods increases significantly due to the large capacity size and spectral dimensions. These methods also face difficulties in manipulating information from local intrinsic detailed patterns of feature maps and low-rank frequency feature tuning. To overcome these challenges and improve HSI classification performance, we propose an innovative approach called the Attention 3D Central Difference Convolutional Dense Network (3D-CDC Attention DenseNet). Our 3D-CDC method leverages the manipulation of local intrinsic detailed patterns in the spatial-spectral features maps, utilizing pixel-wise concatenation and spatial attention mechanism within a dense strategy to incorporate low-rank frequency features and guide the feature tuning. Experimental results on benchmark datasets such as Pavia University, Houston 2018, and Indian Pines demonstrate the superiority of our method compared to other HSI classification methods, including state-of-the-art techniques. The proposed method achieved 97.93% overall accuracy on the Houston-2018, 99.89% on Pavia University, and 99.38% on the Indian Pines dataset with the 25 × 25 window size.


Assuntos
Povo Asiático , Benchmarking , Humanos , Redes Neurais de Computação , Telemetria , Universidades
6.
J Vis Exp ; (206)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38647323

RESUMO

Changes in the mother-offspring relationship are presumably accompanied by dynamic changes in the autonomic nervous system. Although temporal measurements of autonomic activity have been performed in human mothers and infants, the analysis of long-term changes remains unexplored. Mouse mothers can form social bonds with their pups and have a short period of pregnancy and lactation, which makes them useful for the examination of physiological changes from pregnancy to pup-rearing. Therefore, a telemetry system was used for several weeks to measure the changes in the autonomic nervous system and the behavior of mouse mothers. The current results showed that an electrocardiogram (ECG) could be stably recorded regardless of the movements of mothers and parturition. ECG analysis showed that the heart rate gradually decreased from pregnancy to lactation, and sympathetic activity sharply increased as the pups developed. Furthermore, the simultaneous recording of behavior and ECG in the home cage enabled us to understand the behavior-dependent influences on the ECG, thereby revealing the characteristics of autonomic nervous activity during each behavior. Thus, the present experimental method helps to understand how the physiological characteristics of mothers change from pregnancy through pup rearing, supporting the healthy development of pups.


Assuntos
Comportamento Animal , Eletrocardiografia , Lactação , Animais , Feminino , Gravidez , Camundongos , Lactação/fisiologia , Eletrocardiografia/métodos , Comportamento Animal/fisiologia , Sistema Nervoso Autônomo/fisiologia , Frequência Cardíaca/fisiologia , Telemetria/métodos
7.
Lab Anim (NY) ; 53(5): 117-120, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38637688

RESUMO

Many research groups explore the regulation of hibernation or compare the physiology of heterothermic mammals between the torpid and aroused, euthermic states. Current methods for monitoring torpor (for example, infrared cameras, body temperature or heart-rate telemetry, and motion sensing) are costly, require specialized techniques, and can be invasive. Here we present an alternate method for determining torpor-bout duration that is cost-effective, noninvasive and accurate: paper towel shredding. In the winter, euthermic thirteen-lined ground squirrels will shred paper towels placed in the cage, but torpid animals will not. The presence of a shredded paper towel, indicating an arousal from torpor, is easily evaluated during routine daily monitoring. In 12 animals over 52 days, this simple technique detected 59 arousals with 100% accuracy when compared with the body temperature telemetry of the same animals. Moreover, this novel method avoids some of the drawbacks of other cheap monitoring systems such as the sawdust technique.


Assuntos
Hibernação , Sciuridae , Animais , Sciuridae/fisiologia , Hibernação/fisiologia , Nível de Alerta/fisiologia , Telemetria/métodos , Telemetria/veterinária , Temperatura Corporal , Masculino , Papel , Abrigo para Animais
8.
J Am Heart Assoc ; 13(9): e031523, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38686881

RESUMO

BACKGROUND: The objectives of this study were to (1) evaluate telemetry use pre- and postimplementation of clinical decision support tools to support American Heart Association practice standards for telemetry monitoring and (2) understand the factors that may contribute to variation of telemetry monitoring in practice. METHODS AND RESULTS: First, we captured overall variability in telemetry use pre- and postimplementation of the clinical decision support intervention. We then conducted semistructured interviews with telemetry-ordering providers to identify key barriers and facilitators to adoption. During the study period, 399 physicians met criteria for inclusion and were divided into excessive and nonexcessive orderers. Distribution of telemetry use was bimodal. Among nonexcessive users, 24.4% of patient days were with telemetry compared with 51.6% among excessive users. On average, both excessive (6.1% reduction) and nonexcessive users (2.8% reduction) decreased telemetry use postimplementation, and these reductions were sustained over a 16-month period. Sixteen interviews were conducted. Physicians believed that the tool was successful because it caused them to more closely consider if telemetry was indicated for each patient. Physicians also voiced frustration with interruptions to their workflow, and some noted that they commonly use telemetry outside of practice standards to monitor patients who were acutely but not critically ill. CONCLUSIONS: Embedding telemetry practice standards into the electronic health record in the form of clinical decision support is effective at reducing excess telemetry use. Although the intervention was well received, there are persistent barriers, such as preexisting views on telemetry and existing workflow habits, that may inhibit higher adoption of standards.


Assuntos
American Heart Association , Sistemas de Apoio a Decisões Clínicas , Padrões de Prática Médica , Telemetria , Humanos , Estados Unidos , Padrões de Prática Médica/normas , Padrões de Prática Médica/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Fidelidade a Diretrizes , Atitude do Pessoal de Saúde , Masculino
9.
J Int Adv Otol ; 20(1): 89-93, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38454296

RESUMO

Cochlear implantation has become a standard of care for a child diagnosed with bilateral profound sensorineural hearing loss with a structured surgical standard operating procedure. A 3-year-old boy with bilateral profound prelingual sensorineural deafness underwent a Med-EL Sonata Ti100 implant. We faced a peculiar situation intraoperatively after inserting the electrodes and closing the wound. The impedance recording indicated high ground path impedance with short-circuiting of few electrodes. As a bionic implant, its electronic components may at times malfunction both intraoperatively and/or postoperatively; therefore, neural response telemetry (NRT) was invented to check it. By using NRT and a few milliliters of normal saline, we were able to diagnose as well as rectify the malfunctioning of the implant.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Pré-Escolar , Humanos , Masculino , Cóclea/cirurgia , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Implantes Cocleares/efeitos adversos , Perda Auditiva Bilateral/cirurgia , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/cirurgia , Solução Salina , Telemetria/métodos
10.
J Environ Manage ; 357: 120773, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38555845

RESUMO

Extraction of coastline from optical remote sensing images is of paramount importance for coastal zone management, erosion monitoring, and intelligent ocean construction. However, nearshore marine environment complexity presents a challenge when capturing small-scale and detailed information regarding coastlines. Furthermore, the presence of numerous tidal flats, suspended sediments, and coastal biological communities exacerbates the reduction in segmentation accuracy, which is particularly noticeable in medium-high-resolution remote sensing image segmentation tasks. Most previous related studies, based primarily on convolutional neural networks (CNNs) or traditional feature extraction methods, faced challenges in detailed pixel-level refinement and lacked comprehensive understanding of the studied images. Therefore, we proposed a new U-shaped deep learning model (STIRUnet) that combines the excellent global modeling ability of SwinTransformer with an improved CNN using an inverted residual module. The proposed method has the capability of global supervised feature learning and layer-by-layer feature extraction, and we conducted sea-land segmentation experiments using GF-HNCD and BSD remote sensing image datasets to validate the performance of the proposed model. The results indicate the following: 1) suspended sediments and coastal biological communities are major contributors to coastline blurring, and 2) the recovery of minute features (e.g., narrow watercourses and microscale artificial structures) effectively enhances edge details and leads to more realistic segmentation outcomes. The findings of this study are highly important in relation of accurate extraction of sea-land information in complex marine environments, and they offer novel insights regarding mixed-pixel identification.


Assuntos
Biota , Redes Neurais de Computação , Telemetria , Processamento de Imagem Assistida por Computador
11.
Accid Anal Prev ; 199: 107519, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38458008

RESUMO

BACKGROUND: Road traffic deaths are increasing globally, and preventable driving behaviours are a significant cause of these deaths. In-vehicle telematics has been seen as technology that can improve driving behaviour. The technology has been adopted by many insurance companies to track the behaviours of their consumers. This systematic review presents a summary of the ways that in-vehicle telematics has been modelled and analysed. METHODOLOGY: Electronic searches were conducted on Scopus and Web of Science. Studies were only included if they had a sample size of 10 or more participants, collected their data over at least multiple days, and were published during or after 2010. 45 relevant papers were included in the review. 27 of these articles received a rating of "good" in the quality assessment. RESULTS: We found a divide in the literature regarding the use of in-vehicle telematics. Some articles were interested in the utility of in-vehicle telematics for insurance purposes, while others were interested in determining the influence that in-vehicle telematics has on driving behaviour. Machine learning analyses were the most common forms of analysis seen throughout the review, being especially common in articles with insurance-based outcomes. Acceleration, braking, and speed were the most common variables identified in the review. CONCLUSION: We recommend that future studies provide the demographical information of their sample so that the influence of in-vehicle telematics on the driving behaviours of different groups can be understood. It is also recommended that future studies use multi-level models to account for the hierarchical structure of the telematics data. This hierarchical structure refers to the individual trips for each driver.


Assuntos
Condução de Veículo , Telemetria , Humanos , Acidentes de Trânsito/prevenção & controle , Seguro , Tecnologia
12.
Ned Tijdschr Geneeskd ; 1682024 02 08.
Artigo em Holandês | MEDLINE | ID: mdl-38375865

RESUMO

OBJECTIVE: To provide an overview of the effectiveness of various forms of home telemonitoring systems for heart failure and the potential role these systems may have in decreasing the burden on healthcare through reduction in heart failure hospitalizations. DESIGN: Meta-analysis of randomized and observational studies. METHODS: A meta-analysis of randomized and observational studies was carried out to assess the effect on mortality and heart failure-related hospitalizations, comparing standard heart failure care with the use of home monitoring systems. RESULTS: The pooled results from 92 studies demonstrate a reduction in the risk of both mortality and heart failure admissions. CONCLUSION: The results of this meta-analysis support the use of home telemonitoring systems. Determining which form of home telemonitoring is most suitable for which patient requires further research.


Assuntos
Insuficiência Cardíaca , Telemedicina , Humanos , Telemetria/métodos , Monitorização Fisiológica/métodos , Hospitalização , Telemedicina/métodos , Insuficiência Cardíaca/terapia
13.
Sensors (Basel) ; 24(4)2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38400327

RESUMO

The design and experimental verification of a deeply implanted conformal printed antenna is presented. The hip implant acts as the ground plane for a coaxial-cable-fed trapezoidal radiator designed to transmit biological signals collected within the body by proper biosensors. The arrangement, consisting of a metallic (or equivalent) hip implant, bio-compatible gypsum-based dielectric, and conformal radiator, was tested when the hosting 3D-printed plastic bone was immersed in tissue-like liquid contained in a plastic bucket. The dimensions of the set-up are similar to a human leg. Matching and radiation characteristics are presented in the industrial, scientific, and medical (ISM) frequency band (2.4-2.5 GHz), showing the feasibility of the proposed arrangement.


Assuntos
Telemetria , Tecnologia sem Fio , Humanos , Próteses e Implantes
14.
Acta otorrinolaringol. esp ; 75(1): 23-30, ene.-feb. 2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-229268

RESUMO

Introducción El umbral de confort máximo o maximum comfort level (MCL), umbral eléctrico o threshold level (THR) e impedancia eléctrica cambian en el postoperatorio del implante coclear durante meses hasta estabilizarse. El objetivo de este artículo es establecer la variación durante cinco años posquirúrgicos de la impedancia, y su relación con MCL en adultos implantados unilateralmente. Métodos Estudio retrospectivo a cinco años, con 78 pacientes adultos implantados con MED-EL en un hospital terciario desde el año 2000 hasta 2015. Se analizó la variación de impedancia, MCL y relación entre ellos, en electrodos basales (9-12), medios (5-8) y apicales (1-4), realizando análisis inferencial ANOVA de medidas repetidas con comparaciones entre tiempos consecutivos, corregidas con criterio Bonferroni. Resultados Treinta y tres hombres (42,3%) y 45 mujeres (57,7%), con edad media 52,7 ± 14,6 años. Se consideró «estabilidad» el momento del seguimiento sin diferencias estadísticamente significativas entre una visita y la siguiente. Los cambios en la impedancia en electrodos medios dejaron de ser estadísticamente significativos a los tres meses, y en apicales a los seis meses, con valores medios de 5,84 y 6,43 kohms. MCL se estabilizó a los dos años en electrodos basales y apicales, y a los tres años en medios, con valores medios de 24,9, 22,7 y 25,6 qu. Hubo correlación entre MCL e impedancia en electrodos medios hasta 3 meses y en apicales hasta un año. Conclusiones La impedancia eléctrica desciende significativamente en electrodos medios y apicales hasta tres y seis meses. El MCL aumenta significativamente hasta dos años. La impedancia se relaciona con MCL hasta seis meses. (AU)


Introduction The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. Methods Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. Results 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7 ± 14.6 years. “Stability” was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43 kohms. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6 qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. Conclusions Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Impedância Elétrica , Implantes Cocleares/efeitos adversos , Telemetria , Estudos Retrospectivos
15.
IEEE Trans Haptics ; 17(1): 72-79, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38265896

RESUMO

Many recent games, such as racing and flight games, open their game telemetry data to users by storing them in the local memory. Such telemetry data can provide useful information for haptic rendering, and this advantage has been exploited by the industry. This approach applies to any applications that export telemetry data in run time. The haptic rendering module operates as a separate process that accesses the telemetry data in parallel with the application. It is simple, efficient, and modular while retaining the application intact. We examine the approach's viability for user experience improvement by developing three telemetry-based haptic rendering algorithms for car racing games. They express the car engine response, collisions with external objects, and the road surface texture, respectively. Building a haptics-enabled driving platform, we conducted a user study comparing gaming experiences between our telemetry-based algorithms and conventional sound-to-tactile conversion algorithms. The results showed that the telemetry-based effects elicited better experiences than the sound-based effects.


Assuntos
Percepção do Tato , Humanos , Tecnologia Háptica , Tato/fisiologia , Algoritmos , Telemetria
16.
Heart Rhythm ; 21(5): 581-589, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246569

RESUMO

BACKGROUND: The Apple Watch™ (AW) offers heart rate (HR) tracking by photoplethysmography (PPG) and single-lead electrocardiographic (ECG) recordings. The accuracy of AW-HR and diagnostic performance of AW-ECGs among children during both sinus rhythm and arrhythmias have not been explored. OBJECTIVE: The purposes of this study were to assess the accuracy of AW-HR measurements compared to gold standard modalities in children during sinus rhythm and arrhythmias and to identify non-sinus rhythms using AW-ECGs. METHODS: Subjects ≤18 years wore an AW during (1) telemetry admission, (2) electrophysiological study (EPS), or (3) exercise stress test (EST). AW-HRs were compared to gold standard modality values. Recorded AW-ECGs were reviewed by 3 blinded pediatric electrophysiologists. RESULTS: Eighty subjects (median age 13 years; interquartile range 1.0-16.0 years; 50% female) wore AW (telemetry 41% [n = 33]; EPS 34% [n = 27]; EST 25% [n = 20]). A total of 1090 AW-HR measurements were compared to time-synchronized gold standard modality HR values. Intraclass correlation coefficient (ICC) was high 0.99 (0.98-0.99) for AW-HR during sinus rhythm compared to gold standard modalities. ICC was poor comparing AW-HR to gold standard modality HR in tachyarrhythmias (ICC 0.24-0.27) due to systematic undercounting of AW-HR values. A total of 126 AW-ECGs were reviewed. Identification of non-sinus rhythm by AW-ECG showed sensitivity of 89%-96% and specificity of 78%-87%. CONCLUSIONS: We found high levels of agreement for AW-HR values with gold standard modalities during sinus rhythm and poor agreement during tachyarrhythmias, likely due to hemodynamic effects of tachyarrhythmias on PPG-based measurements. AW-ECGs had good sensitivity and moderate specificity in identification of non-sinus rhythm in children.


Assuntos
Arritmias Cardíacas , Frequência Cardíaca , Fotopletismografia , Humanos , Feminino , Masculino , Criança , Adolescente , Frequência Cardíaca/fisiologia , Pré-Escolar , Lactente , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Fotopletismografia/métodos , Fotopletismografia/instrumentação , Reprodutibilidade dos Testes , Telemetria/instrumentação , Telemetria/métodos , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia/métodos , Desenho de Equipamento , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/instrumentação , Teste de Esforço/métodos
17.
PLoS One ; 19(1): e0297152, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38241298

RESUMO

The extraction of roadways from remote sensing imagery constitutes a pivotal task, with far-reaching implications across diverse domains such as urban planning, management of transportation systems, emergency response initiatives, and environmental monitoring endeavors. Satellite images captured during daytime have customarily served as the primary resource for this extraction process. However, the emergence of Nighttime Light (NTL) remote sensing data introduces an innovative dimension to this arena. The exploration of NTL data for road extraction remains in its nascent stage, and this study seeks to bridge this gap. We present a refined U-Net model (CA U-Net) integrated with Cross-Attention Mechanisms, meticulously designed to extract roads from Yangwang-1 NTL images. This model incorporates several enhancements, thereby improving its proficiency in identifying and delineating road networks. Through extensive experimentation conducted in the urban landscape of Wenzhou City, the model delivers highly accurate results, achieving an F1 score of 84.46%. These outcomes significantly surpass the performance benchmarks set by Support Vector Machines (SVM) and the Optimal Threshold (OT) method. This promising development paves the way towards maximizing the utility of NTL data for comprehensive mapping and analysis of road networks. Furthermore, the findings underscore the potential of utilizing Yangwang-1 data as a reliable source for road extraction and reaffirm the viability of deploying deep learning frameworks for road extraction tasks utilizing NTL data.


Assuntos
Monitoramento Ambiental , Telemetria , Cidades , China , Monitoramento Ambiental/métodos , Planejamento de Cidades
18.
Sensors (Basel) ; 24(2)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38257475

RESUMO

Heart rate is a key vital sign that can be used to understand an individual's health condition. Recently, remote sensing techniques, especially acoustic-based sensing, have received increasing attention for their ability to non-invasively detect heart rate via commercial mobile devices such as smartphones and smart speakers. However, due to signal interference, existing methods have primarily focused on monitoring a single user and required a large separation between them when monitoring multiple people. These limitations hinder many common use cases such as couples sharing the same bed or two or more people located in close proximity. In this paper, we present an approach that can minimize interference and thereby enable simultaneous heart rate monitoring of multiple individuals in close proximity using a commonly available smart speaker prototype. Our user study, conducted under various real-life scenarios, demonstrates the system's accuracy in sensing two users' heart rates when they are seated next to each other with a median error of 0.66 beats per minute (bpm). Moreover, the system can successfully monitor up to four people in close proximity.


Assuntos
Determinação da Frequência Cardíaca , Telemetria , Humanos , Frequência Cardíaca , Acústica , Computadores de Mão
19.
Sci Data ; 11(1): 143, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38291027

RESUMO

Data on the movement and space use of aquatic animals are crucial to understand complex interactions among biotic and abiotic components of ecosystems and facilitate effective conservation and management. Acoustic telemetry (AT) is a leading method for studying the movement ecology of aquatic animals worldwide, yet the ability to efficiently access study information from AT research is currently lacking, limiting advancements in its application. Here, we describe TrackdAT, an open-source metadata dataset where AT research parameters are catalogued to provide scientists, managers, and other stakeholders with the ability to efficiently identify and evaluate existing peer-reviewed research. Extracted metadata encompasses key information about biological and technical aspects of research, providing a comprehensive summary of existing AT research. TrackdAT currently hosts information from 2,412 journal articles published from 1969 to 2022 spanning 614 species and 380,289 tagged animals. TrackdAT has the potential to enable regional and global mobilization of knowledge, increased opportunities for collaboration, greater stakeholder engagement, and optimization of future ecological research.


Assuntos
Ecossistema , Metadados , Telemetria , Animais , Acústica , Movimento , Telemetria/métodos
20.
Eur J Cardiovasc Nurs ; 23(3): 258-266, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37590960

RESUMO

AIMS: In-hospital telemetry monitoring has been an integrated part of arrhythmia monitoring for decades. A substantial proportion of patients require arrhythmia monitoring during stays in non-intensive care units. However, studies exploring patients' experiences of telemetry monitoring are scarce. Therefore, the aim was to explore and describe patients' experiences of in-hospital telemetry monitoring in a non-intensive care setting. METHODS AND RESULTS: Twenty face-to-face, semi-structured interviews were conducted. Interviews were conducted before discharge at two university hospitals in Norway. The patients were purposively sampled, resulting in a well-balanced population comprising 11 men and nine women, mean age 62 years (range 25-83). Average monitoring time was 9 days (range 3-14). Data were audiotaped, transcribed verbatim, and coded using NVivo software. Qualitative content analysis using an inductive approach was performed. Patients expressed a need for individualized information during telemetry monitoring. Their feelings of safety were related to responses from nurses from the central monitoring station when alarms from the telemetry were triggered. Despite perceived physical restrictions and psychological limitations associated with telemetry monitoring, they found monitoring to be beneficial because it facilitated the diagnosis of arrhythmia. Moreover, they expressed a need for improvements in wearable monitoring equipment. Patients expressed ambivalent feelings about discontinuing the telemetry and their readiness for discharge. CONCLUSION: Patients need individualized information about the results of their telemetry monitoring in order to better understand the arrhythmia management and to increase their experience of safety after discharge. The limitations patients experienced should be taken into consideration in further upgrades of telemetry monitoring equipment.


Assuntos
Arritmias Cardíacas , Telemetria , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Telemetria/métodos , Arritmias Cardíacas/diagnóstico , Pacientes , Hospitais Universitários , Avaliação de Resultados da Assistência ao Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...