RESUMO
Borosilicate glass was developed to enhance the mechanical behavior and smoothness of dental zirconia as an alternative to conventional glaze. This study assessed the mechanical and optical properties of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) coated with borosilicate glass or a commercial glaze fired for an extended period of time. Disc-shaped 3Y-TZP zirconia specimens (Zpex, Tosoh) were sintered at 1550°C for 2 hours. The specimens were divided into three groups: as-sintered (control, C); commercial glaze (G); and borosilicate glass (SL). The glaze and borosilicate glass were applied over the zirconia and fired for 20 minutes at 950°C and 1200°C, respectively. Biaxial flexural strength, fractography, X-ray diffraction (XRD), roughness (Ra and Rz), fracture toughness (Vickers indentation method), color difference (∆E00), and translucency (TP00) analyses were conducted. The t-test or the one-way ANOVA and Tukey's tests were used to analyze the data (α = 0.05). Flexural strength data were subjected to the Weibull analysis. The SL group exhibited the highest flexural strength (1025.8 MPa), whereas the C (859.41 MPa) and G (816.0 MPa) groups exhibited similar values. The SL group also had the highest characteristic strength. The fracture origin in all groups was on the zirconia surface. XRD analysis revealed that the specimens from the SL group contained tetragonal, cubic, and monoclinic phases. The SL group presented the lowest surface roughness. Fracture toughness in the SL group was lower than in the C group, but similar to that observed in the G group. The translucency and color differences observed in the G and SL groups were similar. Borosilicate glass enhanced the flexural strength of 3Y-TZP, promoted the smoothest surface, and exhibited optical properties similar to those of the glaze.
Assuntos
Vidro , Teste de Materiais , Propriedades de Superfície , Difração de Raios X , Ítrio , Zircônio , Zircônio/química , Ítrio/química , Vidro/química , Análise de Variância , Fatores de Tempo , Resistência à Flexão , Silicatos/química , Reprodutibilidade dos Testes , Valores de Referência , Estatísticas não Paramétricas , Cor , Fenômenos Ópticos , Testes de Dureza , Materiais Dentários/químicaRESUMO
This study aimed to assess the fatigue resistance of molars lacking a coronary remnant, using zero, one, two, or three fiberglass posts. Forty caries/crack-free human molars with coronal portions removed at the pulp chamber floor were randomly allocated into four groups (n=10). Following endodontic treatment, posts (Whitepost DC/DC.E 0.5, 1.0, FGM) were silanized (silane agent, Angelus) and cemented with a resin cement (RelyX U200, 3M ESPE). Resin composite cores (Z350, 3M ESPE) were built, and metal crowns were fabricated and cemented using the same luting system. Samples underwent cyclic fatigue testing at 45°, applying load in the occlusal surface at 10 Hz and 100 N initial load for 10,000 cycles, with 50 N increments every 10,000 cycles until failure. Fatigue failure load and cycles for failure data were recorded and subjected to survival analysis through Kaplan-Meier and Mantel-Cox post hoc tests, and Weibull analysis. Fractography patterns of failed crowns were qualitatively analyzed. The group without posts exhibited the lowest fatigue performance (p < 0.05) for both fatigue failure load and cycles to failure. Superior fatigue performance was observed in the three-post group, followed by groups with one or two posts, corroborated by the Weibull characteristic strength parameter. Weibull moduli were similar among conditions. All specimens exhibited failure involving detachment of the restorative set (posts/core/crown) with a portion of the dental remnant, without tooth fracture. Thus, when restoring mandibular molars without crown remnants, the use of fiberglass posts promotes greater fatigue resistance to oblique loads.
Assuntos
Vidro , Dente Molar , Técnica para Retentor Intrarradicular , Humanos , Análise do Estresse Dentário , Falha de Restauração Dentária , Coroas , Teste de MateriaisRESUMO
PURPOSE: This study aimed to assess the impact of battery levels in single-peak and multi-peak light-curing units (LCUs) on irradiance, and their effects on glass fiber post push-out bond strength to root dentin and the degree of conversion of dual-cure universal resin cement. METHODS AND MATERIALS: Sixty bovine roots underwent endodontic treatment and were randomly distributed into 6 groups (n=10), formed by combining two LCUs (single-peak and multipeak) and three battery levels (100%, 50%, and 10%). A spectrophotometer measured irradiance (mW/ cm2) and spectral irradiance (mW/cm2/nm). Push-out bond strength (PBS) tests occurred at three root regions (cervical, middle, and apical), with optical and scanning electron microscopy for failure mode analysis. Degree of conversion (DC) was evaluated across the root regions. Data were analyzed using two-way repeated measures ANOVA and the Tukey HSD test. The Fisher exact test verified failure modes (α=0.05). RESULTS: As multipeak LCU battery levels decreased, emitted irradiance also diminished, with notable PBS reductions in the apical thirds. Failure modes were influenced by different conditions, primarily exhibiting mixed modes. Battery levels significantly impacted DC in the multipeak LCU, particularly in the cervical region, while the single-peak LCU exhibited DC reduction at the 10% battery level in the cervical region. CONCLUSIONS: Emitted irradiance, resin cement DC, and glass fiber post bond strength to root dentin may be influenced by varying cordless LCUs and battery levels.
Assuntos
Lâmpadas de Polimerização Dentária , Vidro , Técnica para Retentor Intrarradicular , Cimentos de Resina , Cimentos de Resina/química , Bovinos , Técnica para Retentor Intrarradicular/instrumentação , Animais , Teste de Materiais , Microscopia Eletrônica de Varredura , Colagem Dentária/métodos , Análise do Estresse Dentário , Cura Luminosa de Adesivos Dentários/métodos , Técnicas In Vitro , DentinaRESUMO
Portland cement (PC) production is among the industrial activities that most emit harmful gases. Its replacement to green binders turns into a timely issue to face the global restrictions due to climate changes. In this study, some properties of cementitious pastes prepared with waste packing glass powder (GP) and silica fume (SF) were characterized in line with a prefixed alkaline equivalent limit. These materials were obtained in Northeastern Brazil. Grinding operations used to produce GP into four size ranges ([45-75] µm, < 45 µm; [25-45] µm, < 25 µm) were disclosed. X ray diffraction showed that GP and SF substitutions did not change the hydration products commonly observed in PC pastes. The portlandite content measured with thermogravimetry was affected by GP size in both unitary and binary substitutions. The compressive strength measured after 56 days of curing was dependent on portlandite and void index contents measured in hardened pastes. Scanning electron microscopy coupled to energy dispersive spectroscopy were useful to show the effect of the particle size on the pozzolanic activity. It was found that 5% of PC replacement for GP < 25 µm was enough to raise the compressive strength by ~5%. For binary substitution, the strength increasing was ~ 20 %. The collectors of solid residues are the main players of waste glass recycling in Brazil. It is expected that the results of this study contribute to take out these workers from the fringes of the citizenship.
Assuntos
Materiais de Construção , Vidro , Microscopia Eletrônica de Varredura , Pós , Dióxido de Silício , Difração de Raios X , Vidro/química , Dióxido de Silício/química , Materiais de Construção/análise , Teste de Materiais , Tamanho da Partícula , Termogravimetria , Força Compressiva , Brasil , Espectrometria por Raios XRESUMO
OBJECTIVE: To evaluate experimental dimethacrylate-based materials containing calcium orthophosphates or calcium silicate particles in terms of their optical, mechanical and Ca2+ release behaviour. METHODS: Dicalcium phosphate dihydrate (DCPD), hydroxyapatite (HAp), beta-tricalcium phosphate (ß-TCP) or calcium silicate (CaSi) particles were added to a photocurable BisGMA/TEGDMA resin (1:1 in mols) at a 30 vol% fraction. Materials containing silanized or non-silanized barium glass particles were used as controls. Degree of conversion (DC) at the top and base of 2-mm thick specimens was determined by ATR-FTIR spectroscopy (n = 5). Translucency parameter (TP) and transmittance (%T) were determined using a spectrophotometer (n = 3). Biaxial flexural strength (BFS) and flexural modulus (FM) were determined by biaxial flexural testing after 24 h storage in water (n = 10). Ca2+ release in water was determined during 28 days by inductively coupled plasma optical emission spectrometry (n = 3). Statistical analysis was performed using ANOVA/Tukey test (DC: two-way; TP, %T; BFS and FM: one-way; Ca2+ release: repeated measures two-way, α = 5 %). RESULTS: CaSi and ß-TCP particles drastically reduced DC at 2 mm, TP and %T (p < 0.001). Compared to both controls, all Ca2+-releasing materials presented lower BFS (p < 0.001) and only the material with DCPD showed significantly lower FM (p < 0.05). The material containing CaSi presented the highest Ca2+ release, while among materials formulated with calcium orthophosphates the use of DCPD resulted in the highest release (p < 0.001). SIGNIFICANCE: CaSi particles allowed the highest Ca2+ release. Notwithstanding, the use of DCPD resulted in a material with the best compromise between optical behaviour, DC, strength and Ca2+ release.
Assuntos
Compostos de Cálcio , Fosfatos de Cálcio , Teste de Materiais , Silicatos , Silicatos/química , Compostos de Cálcio/química , Fosfatos de Cálcio/química , Espectroscopia de Infravermelho com Transformada de Fourier , Durapatita/química , Resistência à Flexão , Ácidos Polimetacrílicos/química , Polietilenoglicóis/química , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Vidro/química , Cálcio/química , Espectrofotometria , Fenômenos Químicos , Dióxido de Silício , Compostos de BárioRESUMO
This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.
Assuntos
Resinas Compostas , Colagem Dentária , Dentina , Vidro , Técnica para Retentor Intrarradicular , Humanos , Resinas Compostas/química , Colagem Dentária/métodos , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Materiais Dentários/química , Dente não VitalRESUMO
Titanium-based implants have long been studied and used for applications in bone tissue engineering, thanks to their outstanding mechanical properties and appropriate biocompatibility. However, many implants struggle with osseointegration and attachment and can be vulnerable to the development of infections. In this work, we have developed a composite coating via electrophoretic deposition, which is both bioactive and antibacterial. Mesoporous bioactive glass particles with gentamicin were electrophoretically deposited onto a titanium substrate. In order to validate the hypothesis that the quantity of particles in the coatings is sufficiently high and uniform in each deposition process, an easy-to-use image processing algorithm was designed to minimize human dependence and ensure reproducible results. The addition of loaded mesoporous particles did not affect the good adhesion of the coating to the substrate although roughness was clearly enhanced. After 7 days of immersion, the composite coatings were almost dissolved and released, but phosphate-related compounds started to nucleate at the surface. With a simple and low-cost technique like electrophoretic deposition, and optimized stir and suspension times, we were able to synthesize a hemocompatible coating that significantly improves the antibacterial activity when compared to the bare substrate for both Gram-positive and Gram-negative bacteria.
Assuntos
Antibacterianos , Quitosana , Eletroforese , Gentamicinas , Vidro , Teste de Materiais , Nanopartículas , Tamanho da Partícula , Propriedades de Superfície , Titânio , Gentamicinas/farmacologia , Gentamicinas/química , Titânio/química , Titânio/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Vidro/química , Nanopartículas/química , Quitosana/química , Quitosana/farmacologia , Porosidade , Testes de Sensibilidade Microbiana , Humanos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Próteses e Implantes , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologiaRESUMO
Poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) nanofibers embedded with borate glasses of 45B5 composition doped with Co2+, Cu2+, and Zn2 +(46.1 B2O326.9-X CaO24.4 Na2O2.6 P2O5, X CoO/CuO/ZnO mol % (X = 0-5)) were produced by electrospinning for wound healing applications. Prior to their addition, the glasses exhibited two broad halos typical of a vitreous borate network, which were mainly composed of ring-type metaborate structural units. The particle distribution in the PHBV nanofibers embedded with 45B5 borate bioactive glasses is present in isolated and agglomerated states, being partially coated by a polymeric layer-except for the cobalt-doped glass, which resulted in a successful encapsulation with 100% embedding efficiency. The incorporation of the glasses reduced the PHBV crystallinity degree and its decomposition temperature, as well as its mechanical properties, including Young's modulus, tensile strength, and elongation at break. The neat PHBV fibers and those containing the cobalt-doped glasses demonstrated great cytocompatibility with human keratinocytes (HaCat), as suggested by the high cell viability after 7 days of exposure. Further studies are needed to fully understand the wound healing potential of these fibers, but our results significantly contribute to the area.
Assuntos
Bandagens , Boratos , Cobalto , Cobre , Poliésteres , Zinco , Humanos , Cobre/química , Cobalto/química , Poliésteres/química , Boratos/química , Zinco/química , Vidro/química , Teste de Materiais , Cicatrização , Nanofibras/química , Linhagem Celular , Poli-HidroxibutiratosRESUMO
A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement. The use of custom-made computer-aided design-computer-aided manufacturing (CAD-CAM) fibre-reinforced composite post-core facilitates repairability, provides better adaptation to the root canal space, avoids uneven cement thickness, ensures chemical adhesion to resin cement, and promotes favourable aesthetics when combined with all-ceramic crowns.
Assuntos
Resinas Compostas , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Vidro , Técnica para Retentor Intrarradicular , Humanos , Resinas Compostas/química , Vidro/química , Cimentos de Resina/química , Coroas , Estética Dentária , Retenção em Prótese Dentária , Materiais Dentários/química , CimentaçãoRESUMO
The purpose of this study was to evaluate the fatigue survival of 5Y-PSZ zirconia infiltrated with an experimental glass and bonded onto dentin analogues. Disc-shaped specimens of a 5Y-PSZ (Katana UTML Kuraray Noritake) were cemented onto dentin analogs (NEMA G10) and divided into four groups (n = 15): Zctrl Group (control, without infiltration); Zglz Group (Glaze, compression surface); Zinf-comp Group (Experimental Glass, compression surface); Zinf-tens Group (Experimental Glass, tension surface). Surface treatments were varied. Cyclic fatigue loading, oblique transillumination, stereomicroscope examination, and scanning electron microscopy were performed. Fatigue data were analyzed (failure load and number of cycles) using survival analysis (Kaplan-Meier and Log-Rank Mantel-Cox). There was no statistically significant difference in fatigue survival between the Zglz, Zctrl, and Zinf-comp groups. The Zinf-tens group presented a significantly higher failure load when compared to the other groups and exhibited a different failure mode. The experimental glass effectively infiltrated the zirconia, enhancing structural reliability, altering the failure mode, and improving load-bearing capacity over more cycles, particularly in the group where the glass was infiltrated into the tensile surface of the zirconia. Glass infiltration into 5Y-PSZ zirconia significantly enhanced structural reliability and the ability to withstand loads over an increased number of cycles. This approach has the potential to increase the durability of zirconia restorations, reducing the need for replacements and save time and resources, promoting efficiency in clinical practice.
Assuntos
Dentina , Vidro , Teste de Materiais , Zircônio , Zircônio/química , Vidro/química , Dentina/química , Humanos , Microscopia Eletrônica de Varredura , Propriedades de SuperfícieRESUMO
This study evaluated bond strength of glass fiber posts to root dentin using push-out (PO) and diametral compression (DC), testing glycolic acid as a conditioner and varying dentin moisture. An additional aim was to test whether DC can be an alternative test to PO for bond strength assessment. Eighty bovine teeth were divided into eight groups (n = 10) defined by the use of either 37% glycolic acid or 37% phosphoric acid (PA) on moist or wet dentin before bonding with either Adapter SingleBond/RelyX ARC or One Step Plus/Duo-Link Bisco. Each tooth provided discs with an internal diameter of 2 mm, external diameter of 5 mm, and height of 2 mm, which underwent PO and DC. Finite element analysis (FEA) was carried out on 3D models. When analyzing PO results through linear regression, the highest values of bond strength were observed using glycolic acid on wet dentin in the cervical and middle thirds of the teeth. Analyzing DC results, the only statistical influence on values was the dental thirds. The scatterplot of the DC results and the PO bond strength values indicated no relationship between the results of the two tests (r = 0.03; p = 0.64). PO test detected more sensitive changes in bond strength values than DC.
Assuntos
Colagem Dentária , Dentina , Análise de Elementos Finitos , Vidro , Ácidos Fosfóricos , Técnica para Retentor Intrarradicular , Animais , Bovinos , Dentina/efeitos dos fármacos , Vidro/química , Ácidos Fosfóricos/química , Adesivos Dentinários/química , Cimentos de Resina/química , Análise do Estresse Dentário , Teste de Materiais , Raiz Dentária , Glicolatos/química , Condicionamento Ácido do DenteRESUMO
This study aimed to investigating the possible interference caused by glass test tubes on the quantification of bacterial adhesion to hydrocarbons by the MATH test. The adhesion of four bacteria to hexadecane and to glass test tubes was evaluated employing different suspending polar phases. The role of the ionic strength of the polar phase regarding adhesion to glassware was investigated. Within the conditions studied, Gram-positive bacteria adhered to both the test tube and the hydrocarbon regardless of the polar phase employed; meanwhile, Escherichia coli ATCC 25922 did not attach to either one. The capacity of the studied microorganisms to adhere to glassware was associated with their electron-donor properties. The ionic strength of the suspending media altered the patterns of adhesion to glass in a strain-specific manner by defining the magnitude of electrostatic repulsion observed between bacteria and the glass surface. This research demonstrated that glass test tubes may interact with suspended bacterial cells during the MATH test under specific conditions, which may lead to overestimating the percentage of adhesion to hydrocarbons and, thus, to erroneous values of cell surface hydrophobicity.
Assuntos
Aderência Bacteriana , Vidro , Vidro/química , Escherichia coli , Alcanos/química , Concentração Osmolar , Interações Hidrofóbicas e Hidrofílicas , Hidrocarbonetos/metabolismo , Bactérias Gram-Positivas/isolamento & purificaçãoRESUMO
OBJECTIVE: This study aimed to evaluate the effect of ultrasonic activation of etch-and-rinse and self-etch adhesive systems on the bond strength of resin cement to irradiated root dentin. MATERIALS AND METHODS: Eighty human maxillary anterior teeth were distributed into 8 groups (n = 10), according to the type of adhesive system used (etch-and-rinse and self-etch), the ultrasonic activation of the adhesive systems, and the dentin condition (irradiated or non-irradiated - 70 Gy). Endodontic treatment was performed followed by fiberglass post-space preparation. After fiberglass posts' luting, the roots were transversely sectioned on dentin discs and submitted to the push-out bond strength test (0.5 mm/min). The fractured specimens were analyzed under a stereomicroscope and Scanning Electron Microscope (SEM) for failure mode classification. One of the dentin discs was analyzed under SEM to evaluate the characteristics of the adhesive interface. RESULTS: Irradiated specimens had lower bond strength than non-irradiated specimens (P < 0.0001). Ultrasonic activation of both adhesive systems increased the bond strength of the resin cement to irradiated dentin (P < 0.0001). Radiotherapy significantly affected the failure mode in the middle (P = 0.024) and apical thirds (P = 0.032) (adhesive failure). CONCLUSION: Non-irradiated specimens had a more homogeneous adhesive interface. When ultrasonically activated, both adhesive systems showed a greater number of resinous tags, regardless of the dentin condition. CLINICAL RELEVANCE: Ultrasonic activation of adhesive systems is a feasible strategy to enhance fiberglass posts retention in oncological patients.
Assuntos
Colagem Dentária , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular , Cimentos de Resina , Humanos , Cimentos de Resina/química , Colagem Dentária/métodos , Dentina/efeitos da radiação , Técnicas In Vitro , Adesivos Dentinários/química , Análise do Estresse Dentário , Propriedades de Superfície , Raiz Dentária/efeitos da radiação , Ultrassom , Condicionamento Ácido do Dente , Incisivo , Vidro/químicaRESUMO
OBJECTIVE: To evaluate the influence of the barium glass (BG) filler in 3D printing resin-based composites for restorative structures. METHODS: Experimental 3D printing resin-based composites were formulated with UDMA 70%wt, Bis-EMA 20%wt, and TEGDMA 10%wt. Photoinitiators TPO and DFI (2%wt) were used. BG was incorporated at 40%wt and 50%wt. 0%wt BG was used as negative control and the VarseoSmile Crownplus (Bego) was used as a commercial control. Specimens were printed using a 3D printer. Subsequently, specimens were washed and submitted to post-curing with 405 nm at 60ºC for 2 × 20 min at FormCure (FormLabs). 3D printing resin-based composites were evaluated by flexural strength, degree of conversion, softening in solvent, radiopacity, and cytotoxicity against gingival fibroblasts. Data were statistically analyzed using one-way ANOVA (α = 0.05). RESULTS: No significant differences in flexural strength were showed between BG40% (90.5 ± 5,4 MPa), BG50% (102.0 ± 11.7 MPa) and VA (105.2 ± 11.7 MPa). Addition of 40% and 50% of BG showed no influence in the degree of conversion compared to VA (p > 0.05). All groups showed softening in solvent after immersion in ethanol (p < 0.05). All groups showed more than 1mmAl of radiopacity. BG50% showed significantly higher radiopacity (2.8 ± 0.3 mmAl) than other groups (p < 0,05). Cytotoxicity evaluation showed gingival cell viability higher than 80% for all groups. SIGNIFICANCE: Addition of up to 50%wt of barium glass in experimental 3D printing resin-based composites showed promising results for long-term restorative structures.
Assuntos
Compostos de Bário , Resinas Compostas , Teste de Materiais , Metacrilatos , Polietilenoglicóis , Impressão Tridimensional , Resinas Compostas/química , Compostos de Bário/química , Polietilenoglicóis/química , Metacrilatos/química , Poliuretanos/química , Resistência à Flexão , Vidro/química , Ácidos Polimetacrílicos/química , Bis-Fenol A-Glicidil Metacrilato/química , Humanos , Fibroblastos/efeitos dos fármacos , Gengiva , Fotoiniciadores Dentários/química , Polimerização , Propriedades de Superfície , Dióxido de SilícioRESUMO
This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.
Assuntos
Dentina , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bovinos , Animais , Cimentos de Resina/química , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Adesivos Dentinários/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Teste de Materiais , Vidro/química , Raiz Dentária , Polietilenoglicóis/química , Análise do Estresse DentárioRESUMO
OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.
Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese DentáriaRESUMO
Inorganic-organic hybrid biomaterials have been proposed for bone tissue repair, with improved mechanical flexibility compared with scaffolds fabricated from bioceramics. However, obtaining hybrids with osteoinductive properties equivalent to those of bioceramics is still a challenge. In this work, we present for the first time the synthesis of a class II hybrid modified with bioactive glass nanoparticles (nBGs) with osteoinductive properties. The nanocomposite hybrids were produced by incorporating nBGs in situ into a polytetrahydrofuran (PTHF) and silica (SiO2) hybrid synthesis mixture using a combined sol-gel and cationic polymerization method. nBGs ~80 nm in size were synthesized using the sol-gel technique. The structure, composition, morphology, and mechanical properties of the resulting materials were characterized using ATR-FTIR, 29Si MAS NMR, SEM-EDX, AFM, TGA, DSC, mechanical, and DMA testing. The in vitro bioactivity and degradability of the hybrids were assessed in simulated body fluid (SBF) and PBS, respectively. Cytocompatibility with mesenchymal stem cells was assessed using MTS and cell adhesion assays. Osteogenic differentiation was determined using the alkaline phosphatase activity (ALP), as well as the gene expression of Runx2 and Osterix markers. Hybrids loaded with 5, 10, and 15% of nBGs retained the mechanical flexibility of the PTHF-SiO2 matrix and improved its ability to promote the formation of bone-like apatite in SBF. The nBGs did not impair cell viability, increased the ALP activity, and upregulated the expression of Runx2 and Osterix. These results demonstrate that nBGs are an effective osteoinductive nanoadditive for the production of class II hybrid materials with enhanced properties for bone tissue regeneration.
Assuntos
Materiais Biocompatíveis , Vidro , Células-Tronco Mesenquimais , Nanocompostos , Nanopartículas , Osteogênese , Nanocompostos/química , Nanopartículas/química , Vidro/química , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/metabolismo , Osteogênese/efeitos dos fármacos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Humanos , Dióxido de Silício/química , Diferenciação Celular/efeitos dos fármacos , Engenharia Tecidual/métodosRESUMO
Immune response to biomaterials, which is intimately related to their surface properties, can produce chronic inflammation and fibrosis, leading to implant failure. This study investigated the development of magnetic nanoparticles coated with silica and incorporating the anti-inflammatory drug naproxen, aimed at multifunctional biomedical applications. The synthesized nanoparticles were characterized using various techniques that confirmed the presence of magnetite and the formation of a silica-rich bioactive glass (BG) layer. In vitro studies demonstrated that the nanoparticles exhibited bioactive properties, forming an apatite surface layer when immersed in simulated body fluid, and biocompatibility with bone cells, with good viability and alkaline phosphatase activity. Naproxen, either free or encapsulated, reduced nitric oxide production, an inflammatory marker, while the BG coating alone did not show anti-inflammatory effects in this study. Overall, the magnetic nanoparticles coated with BG and naproxen showed promise for biomedical applications, especially anti-inflammatory activity in macrophages and in the bone field, due to their biocompatibility, bioactivity, and osteogenic potential.
Assuntos
Materiais Revestidos Biocompatíveis , Vidro , Nanopartículas de Magnetita , Naproxeno , Naproxeno/farmacologia , Naproxeno/química , Vidro/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Nanopartículas de Magnetita/química , Animais , Camundongos , Humanos , Óxido Nítrico/metabolismo , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Dióxido de Silício/química , Sobrevivência Celular/efeitos dos fármacos , Células RAW 264.7 , Osteogênese/efeitos dos fármacosAssuntos
Produtos Agrícolas , Secas , Vidro , Solo , Produtos Agrícolas/crescimento & desenvolvimento , Vidro/química , Reciclagem , Granada , Solo/químicaRESUMO
Los vidrios bioactivos (VBa) son materiales biocerámicos que tienen una extensa aplicación en medicina y odontología. A causa de su contenido de calcio y fosfato son muy simi- lares a la hidroxiapatita del tejido óseo. Su biocompatibili- dad y bioactividad los hacen materiales muy útiles para ser aplicados en diferentes áreas de la práctica dental, tales como periodoncia, cirugía, odontología restauradora y endodoncia. En endodoncia los VBa están indicados para realizar protec- ciones pulpares directas, pulpotomías, desinfecciones y obtu- raciones del sistema de conductos radiculares. El objetivo del presente trabajo fue realizar una revisión de las propiedades biológicas de los VBa en relación a sus aplicaciones en en- dodoncia (AU)
Bioactive glasses (BGs) are bioceramic materials with extensive clinical applications in medicine and dentistry. Be- cause of their phosphate and calcium contents, they are like the hydroxyapatiteof bone tissue. Their biocompatibility and bioactivity make them very useful biomaterials in different areas of dental practice, such as periodontics, oral surgery, restorative dentistry, and endodontics. In endodontics, bioac- tive glasses are indicated for direct pulp capping, pulpoto- mies, disinfections and fillings of the root canal system. The aim of this work was to carry out a review of the biological properties of BGs in relation to its application in endodontics (AU)