Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.645
Filtrar
2.
Int J Med Robot ; 20(4): e2656, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38970289

RESUMO

BACKGROUND: Minimally invasive percutaneous plate osteosynthesis for humeral shaft fractures (HSFs) has limitations due to malreduction and radiation exposure. To address these limitations, we integrated robotics and 3D printing by incorporating plates as reduction templates. METHOD: The innovative technology facilitated closed reduction of HSFs in the operating theatre using 18 models with cortical marking holes. The dataset of the precontoured plate was imported into 3D planning software for virtual fixation and screw path planning. The models were divided into half to simulate transverse fractures. During the operation, the software generated drilling trajectories for robot navigation, and precise plate installation achieved automatic fracture reduction. RESULTS: The evaluation results of reduction accuracy revealed variations in length, apposition, alignment, and rotation that meet the criteria for anatomic reduction. High interoperator reliabilities were observed for all parameters. CONCLUSIONS: The proposed technology achieved anatomic reduction in simulated bones.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Úmero , Procedimentos Cirúrgicos Minimamente Invasivos , Impressão Tridimensional , Procedimentos Cirúrgicos Robóticos , Humanos , Fraturas do Úmero/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Úmero/cirurgia , Cirurgia Assistida por Computador/métodos , Estudo de Prova de Conceito , Software , Redução Fechada/métodos , Parafusos Ósseos
3.
J Robot Surg ; 18(1): 278, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38960985

RESUMO

Historically, pedicle screw accuracy measurements have relied on CT and expert visual assessment of the position of pedicle screws relative to preoperative plans. Proper pedicle screw placement is necessary to avoid complications, cost and morbidity of revision procedures. The aim of this study was to determine accuracy and precision of pedicle screw insertion via a novel computer vision algorithm using preoperative and postoperative computed tomography (CT) scans. Three cadaveric specimens were utilized. Screw placement planning on preoperative CT was performed according to standard clinical practice. Two experienced surgeons performed bilateral T2-L4 instrumentation using robotic-assisted navigation. Postoperative CT scans of the instrumented levels were obtained. Automated segmentation and computer vision techniques were employed to align each preoperative vertebra with its postoperative counterpart and then compare screw positions along all three axes. Registration accuracy was assessed by preoperatively embedding spherical markers (tantalum beads) to measure discrepancies in landmark alignment. Eighty-eight pedicle screws were placed in 3 cadavers' spines. Automated registrations between pre- and postoperative CT achieved sub-voxel accuracy. For the screw tip and tail, the mean three-dimensional errors were 1.67 mm and 1.78 mm, respectively. Mean angular deviation of screw axes from plan was 1.58°. For screw mid-pedicular accuracy, mean absolute error in the medial-lateral and superior-inferior directions were 0.75 mm and 0.60 mm, respectively. This study introduces automated algorithms for determining accuracy and precision of planned pedicle screws. Our accuracy outcomes are comparable or superior to recent robotic-assisted in vivo and cadaver studies. This computerized workflow establishes a standardized protocol for assessing pedicle screw placement accuracy and precision and provides detailed 3D translational and angular accuracy and precision for baseline comparison.


Assuntos
Algoritmos , Cadáver , Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Cirurgia Assistida por Computador/métodos
4.
J Robot Surg ; 18(1): 273, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38949665

RESUMO

Robotic assistance for total hip arthroplasty (THA) has been demonstrated to improve accuracy of acetabular cup placement relative to manual, unassisted technique. The purpose of this investigation was to compare the accuracy and precision between a fluoroscopy-based robotic total hip arthroplasty platform (FL-RTHA) and a computerized tomography-based (CT-RTHA) platform. The study included 98 consecutive FL-RTHA and 159 CT-RTHA procedures performed via direct anterior approach (DAA). All cases were performed for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included cup implantation accuracy and precision (variance). Implantation accuracy was calculated as the absolute value of the difference between pre-operative target cup angles (inclination and anteversion) and the same post-operative angles. Percentage placement in the Lewinnek safe zone was also measured for both cohorts. The FL-RTHA and CT-RTHA cohorts demonstrated a 1.2° difference in absolute values for cup inclination accuracy (4.6° ± 3.6 vs. 3.4 ± 2.7; p = 0.005), and no difference in absolute values for cup anteversion accuracy (4.7° ± 4.1 vs. 4.6 ± 3.4; p = 0.991). Cohorts demonstrated similar precision for cup inclination and anteversion placement parameters, as well as equivalent Lewinnek safe zone placement. The use of a fluoroscopy-based robotic assistance platform for primary DAA THA resulted in similar accuracy and precision of acetabular cup placement when compared to a CT-based robotic assistance system.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Fluoroscopia/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Prótese de Quadril , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos
5.
J Robot Surg ; 18(1): 282, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38972955

RESUMO

Eighty consecutive complex spinal robotic cases utilizing intraoperative 3D CT imaging (E3D, Group 2) were compared to 80 age-matched controls using the Excelsius robot alone with C-arm Fluoroscopic registration (Robot Only, Group 1). The demographics between the two groups were similar-severity of deformity, ASA Score for general anesthesia, patient age, gender, number of spinal levels instrumented, number of patients with prior spinal surgery, and amount of neurologic compression. The intraoperative CT scanning added several objective factors improving patient safety. There were significantly fewer complications in the E3D group with only 3 of 80 (4%) patients requiring a return to the operating room compared to 11 of 80 (14%) patients in the Robot Only Group requiring repeat surgery for implant related problems (Chi squared analysis = 5.00, p = 0.025). There was a significant reduction the amount of fluoroscopy time in the E3D Group (36 s, range 4-102 s) compared to Robot only group (51 s, range 15-160 s) (p = 0.0001). There was also shorter mean operative time in the E3D group (257 ± 59.5 min) compared to the robot only group (306 ± 73.8 min) due to much faster registration time (45 s). A longer registration time was required in the Robot only group to register each vertebral level with AP and Lateral fluoroscopy shots. The estimated blood loss was also significantly lower in Group 2 (mean 345 ± 225 ml) vs Group 1 (474 ± 397 ml) (p = 0.012). The mean hospital length of stay was also significantly shorter for Group 2 (3.77 ± 1.86 days) compared to Group 1 (5.16 ± 3.40) (p = 0.022). There was no significant difference in the number of interbody implants nor corrective osteotomies in both groups-Robot only 52 cases vs. 42 cases in E3D group.Level of evidence: IV, Retrospective review.


Assuntos
Imageamento Tridimensional , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos , Fusão Vertebral , Tomografia Computadorizada por Raios X , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Feminino , Masculino , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Pessoa de Meia-Idade , Adulto , Imageamento Tridimensional/métodos , Idoso , Fluoroscopia/métodos , Tomografia Computadorizada por Raios X/métodos , Cirurgia Assistida por Computador/métodos , Adulto Jovem , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia
6.
Med Sci Monit ; 30: e944724, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38990791

RESUMO

BACKGROUND The BrainLab VectorVision neuronavigation system is an image-guided, frameless localization system used intraoperatively, which includes a computer workstation for viewing and analyzing operative microscopic images. This retrospective study aimed to evaluate the use of the BrainLab VectorVision infrared-based neuronavigation imaging system in 80 patients with intracranial meningioma removed surgically between 2013 and 2023. MATERIAL AND METHODS Data were retrospectively collected from 36 patients with convexity meningioma and 44 patients with parasagittal meningioma between 2013 and 2023. The surgical operation of 40 of these patients was performed with the help of neuronavigation, while the other 40 were performed without neuronavigation. Demographic data, preoperative and postoperative radiologic images, craniotomy measurements, surgical complications, and operative times of patients with and without neuronavigation were analyzed. RESULTS Using neuronavigation significantly increased surgery duration (P=0.023). In 6 patients without the use of neuronavigation, the craniotomy had to be enlarged and this resulted in superior sagittal sinus (SSS) damage (P=0.77, P=0.107). Patients for whom neuronavigation was used did not experience any sinus damage and did not require craniotomy enlargement. Postoperative epidural hematoma (EH) developed in 9 patients without navigation, whereas it developed in only 1 patient with navigation (P=0.104). Residual tumors were less common in patients using navigation (P=0.237). CONCLUSIONS The use of neuronavigation allows the incision and craniotomy to be reduced in size. Intraoperatively, it allows the surgeon to master the boundaries of the tumor and surrounding vascular structures, reducing the risk of complications. These results suggest that neuronavigation systems are an effective ancillary in meningioma surgery.


Assuntos
Neoplasias Meníngeas , Meningioma , Neuronavegação , Humanos , Meningioma/cirurgia , Meningioma/patologia , Meningioma/diagnóstico por imagem , Neuronavegação/métodos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Neoplasias Meníngeas/cirurgia , Adulto , Idoso , Resultado do Tratamento , Craniotomia/métodos , Cirurgia Assistida por Computador/métodos , Procedimentos Neurocirúrgicos/métodos , Complicações Pós-Operatórias/etiologia
7.
Int J Med Robot ; 20(4): e2664, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38994900

RESUMO

BACKGROUND: This study aimed to develop a novel deep convolutional neural network called Dual-path Double Attention Transformer (DDA-Transformer) designed to achieve precise and fast knee joint CT image segmentation and to validate it in robotic-assisted total knee arthroplasty (TKA). METHODS: The femoral, tibial, patellar, and fibular segmentation performance and speed were evaluated and the accuracy of component sizing, bone resection and alignment of the robotic-assisted TKA system constructed using this deep learning network was clinically validated. RESULTS: Overall, DDA-Transformer outperformed six other networks in terms of the Dice coefficient, intersection over union, average surface distance, and Hausdorff distance. DDA-Transformer exhibited significantly faster segmentation speeds than nnUnet, TransUnet and 3D-Unet (p < 0.01). Furthermore, the robotic-assisted TKA system outperforms the manual group in surgical accuracy. CONCLUSIONS: DDA-Transformer exhibited significantly improved accuracy and robustness in knee joint segmentation, and this convenient and stable knee joint CT image segmentation network significantly improved the accuracy of the TKA procedure.


Assuntos
Artroplastia do Joelho , Aprendizado Profundo , Articulação do Joelho , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Tomografia Computadorizada por Raios X/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Masculino , Redes Neurais de Computação , Feminino , Processamento de Imagem Assistida por Computador/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Tíbia/cirurgia , Tíbia/diagnóstico por imagem , Algoritmos , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Imageamento Tridimensional/métodos
8.
Langenbecks Arch Surg ; 409(1): 213, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995411

RESUMO

PURPOSE: Laparoscopic distal gastrectomy (LDG) is a difficult procedure for early career surgeons. Artificial intelligence (AI)-based surgical step recognition is crucial for establishing context-aware computer-aided surgery systems. In this study, we aimed to develop an automatic recognition model for LDG using AI and evaluate its performance. METHODS: Patients who underwent LDG at our institution in 2019 were included in this study. Surgical video data were classified into the following nine steps: (1) Port insertion; (2) Lymphadenectomy on the left side of the greater curvature; (3) Lymphadenectomy on the right side of the greater curvature; (4) Division of the duodenum; (5) Lymphadenectomy of the suprapancreatic area; (6) Lymphadenectomy on the lesser curvature; (7) Division of the stomach; (8) Reconstruction; and (9) From reconstruction to completion of surgery. Two gastric surgeons manually assigned all annotation labels. Convolutional neural network (CNN)-based image classification was further employed to identify surgical steps. RESULTS: The dataset comprised 40 LDG videos. Over 1,000,000 frames with annotated labels of the LDG steps were used to train the deep-learning model, with 30 and 10 surgical videos for training and validation, respectively. The classification accuracies of the developed models were precision, 0.88; recall, 0.87; F1 score, 0.88; and overall accuracy, 0.89. The inference speed of the proposed model was 32 ps. CONCLUSION: The developed CNN model automatically recognized the LDG surgical process with relatively high accuracy. Adding more data to this model could provide a fundamental technology that could be used in the development of future surgical instruments.


Assuntos
Inteligência Artificial , Gastrectomia , Laparoscopia , Estudo de Prova de Conceito , Neoplasias Gástricas , Humanos , Gastrectomia/métodos , Laparoscopia/métodos , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/patologia , Feminino , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador/métodos , Idoso , Excisão de Linfonodo
9.
Int J Med Robot ; 20(4): e2663, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39004951

RESUMO

BACKGROUND: Blood accumulation often occurs during bleeding in surgery. Simulating the blood accumulation in surgical simulation system not only enhances the realism and immersion of surgical training, but also helps researchers better understand the physical properties of blood flow. METHODS: To realistically simulate the blood accumulation during the bleeding, this paper proposes a novel kernel function with non-negative second derivatives to improve the SPH method. Meanwhile, a simple form of boundary force equation is constructed to impose the solid boundary condition. RESULTS: We simulate the blood accumulation during liver bleeding and vessel bleeding respectively in the surgical simulation system. The simulation results show that there is no occurrence of blood physically penetrating the boundary. CONCLUSIONS: Applying the solid boundary condition to the blood by using the method proposed in this paper is not only convenient but can also eliminate compression instability in the blood accumulation simulation.


Assuntos
Simulação por Computador , Hidrodinâmica , Fígado , Humanos , Fígado/cirurgia , Algoritmos , Perda Sanguínea Cirúrgica/prevenção & controle , Cirurgia Assistida por Computador/métodos , Hemorragia/prevenção & controle
11.
Int J Implant Dent ; 10(1): 36, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39012381

RESUMO

PURPOSE: This study aims to evaluate the amount of distortion using computer-guided implant surgery with 3D printed surgical guides in limited edentulous spaces. MATERIALS AND METHODS: 25 bone level self-tapping implants (Straumann® BL and BLT) were randomly inserted in either distal or intercalary posterior mandibular edentulism using a fully digital protocol and 3D printed surgical guides. Amount of inaccuracy was evaluated after superimposing the 3 coordinates of virtually planned and final implant images, which were obtained using intra-oral scans and scan bodies. Four evaluation parameters were considered: origo-displacement, error depth, apical displacement and angle between the planned and the placed implant. RESULTS: The average of distortion was 0.71 mm for the origo-displacement, 0.36 mm for the error depth, 0.52 mm for the horizontal displacement and 3.34º for the error angle. CONCLUSION: The major reason of exclusion was CBCT artifacts. Results of this study were aligned with the results of previous studies concerning partially edentulous spaces. CAD/CAM manufacturing process did not result in significant distortion whilst the biggest part of distortions originated from the surgical process. The learning curve in computer-guided implant surgery presented an important source of inaccuracy.


Assuntos
Arcada Parcialmente Edêntula , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Estudos Prospectivos , Arcada Parcialmente Edêntula/cirurgia , Arcada Parcialmente Edêntula/diagnóstico por imagem , Implantação Dentária Endóssea/métodos , Implantação Dentária Endóssea/instrumentação , Feminino , Masculino , Pessoa de Meia-Idade , Impressão Tridimensional , Implantes Dentários , Tomografia Computadorizada de Feixe Cônico
12.
BMC Musculoskelet Disord ; 25(1): 562, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39030596

RESUMO

BACKGROUND: The aim of this retrospective study was to evaluate the effectiveness and accuracy of the AIKNEE system in preoperative planning and intraoperative alignment for total knee arthroplasty (TKA). METHODS: A total of 64 patients were planned preoperatively by the AIKNEE system, including the measurement of mechanical femorotibial angle (mFTA), lateral distal femoral angle (LDFA), and medial proximal tibial angle (MPTA) using three-dimensional reconstructed images. Intraoperatively, the actual prosthesis size and alignment were compared to the planned parameters. Postoperative outcomes, including pain levels, range of motion (ROM), and Knee Scoring System (KSS) scores, were assessed after surgery. Statistical analyses were performed to evaluate the correlation between alignment deviations and postoperative function. RESULTS: The AIKNEE system accurately predicted the prosthesis size in thirty-one of femoral cases (48%) and forty-seven of tibial cases (73%). Deviations of mFTA, LDFA, and MPTA from the target value were within 3° in 88%, 92%, and 95% of cases, respectively. A significant improvement was observed in postoperative pain, ROM, and KSS scores (p < 0.001). Correlation analysis revealed that greater deviations in mFTA and LDFA were associated with increased pain (p = 0.004, 0.047) and lower KSS scores (p = 0.027). CONCLUSION: The AIKNEE system demonstrated promising results in predicting prosthesis size and achieved alignment within the desired range in a majority of cases. Postoperative outcomes, including pain levels and functional improvement, were favorable.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Feminino , Estudos Retrospectivos , Masculino , Idoso , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Prótese do Joelho , Idoso de 80 Anos ou mais , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Cuidados Pré-Operatórios/métodos , Resultado do Tratamento , Cirurgia Assistida por Computador/métodos
13.
J Craniofac Surg ; 35(5): 1422-1424, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39042068

RESUMO

PURPOSE: Conventional orthognathic surgical planning has limitations in accurately transferring the relationship between soft tissue and bone. Virtual planning offers enhanced accuracy and visualization through computer simulation. This study aimed to compare the need for reoperation between patients who underwent conventional and virtual surgical planning for orthognathic surgery. MATERIAL AND METHODS: The study included 352 patients who underwent orthognathic surgery. Reoperation rates and reasons for reoperation were evaluated in patients with conventional model surgery planning (143 patients) and virtual planning (209 patients). RESULTS: The reoperation rate was 7.69% for conventional surgery patients and 3.82% for virtual planning patients. Malocclusion was the most common reason for reoperation in both groups. Bilateral sagittal split ramus osteotomies (BSSO) and genioplasty were the most frequently performed revision procedures. CONCLUSION: Virtual planning in orthognathic surgery may lead to a reduced reoperation rate compared with conventional planning methods. The accuracy, visualization, and interdisciplinary collaboration offered by virtual planning can improve surgical outcomes.


Assuntos
Procedimentos Cirúrgicos Ortognáticos , Reoperação , Cirurgia Assistida por Computador , Humanos , Reoperação/estatística & dados numéricos , Feminino , Masculino , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Ortognáticos/métodos , Adulto , Mentoplastia/métodos , Planejamento de Assistência ao Paciente , Osteotomia Sagital do Ramo Mandibular/métodos , Simulação por Computador , Má Oclusão/cirurgia , Má Oclusão/diagnóstico por imagem , Adolescente , Adulto Jovem
15.
Transl Vis Sci Technol ; 13(7): 8, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38980260

RESUMO

Purpose: To describe optical coherence tomography angiography (OCTA)-guided navigated laser photocoagulation (LP) using the Navilas Laser System for treating retinal hemangioblastomas (RHs) associated with von Hippel-Lindau disease (VHLD). Methods: Patients with VHLD were screened using ophthalmoscopy and widefield OCTA. Detected RHs were classified with regard to tumor morphology (endophytic, sessile, exophytic, recurrent) and size. Then, 6 × 6- or 3 × 3-mm2 en face OCTA scans of the RHs were uploaded to the Navilas system, generating a merged image combining the scan and Navilas fundus photography. LP was planned by placing laser spots in the OCTA scan and executed with the Navilas system. Treatment efficacy was assessed by conducting OCTA scans immediately after LP and at follow-up visits. Results: Fifteen RHs were detected in 10 patients (median, one RH; range, one to four). Twelve RHs were treatment naive (exophytic [3], sessile [3], and endophytic [6]), and there were three recurrent RHs in pretreated areas. Total applied energy per tumor correlated with tumor size (P < 0.001). After a mean first follow-up of 3.6 ± 1.5 months (range, 0.9-5.3), nine RHs exhibited complete regression (60%), five partial regression (33.3%), and one no regression (6.7%). No correlation between tumor morphology and treatment success was observed (P = 0.32). However, a correlation between treatment success and tumor size trended toward significance (P = 0.08), with a 100% success rate observed for small RHs. Conclusions: OCTA-guided LP via the Navilas Laser System is a promising technique, especially beneficial for targeting small RHs. Combining OCTA and ophthalmoscopy improves tumor detection, underscoring the utility of this approach. Translational Relevance: OCTA-guided LP enables highly precise and safe treatment of early-stage RHs, minimizing possible complications caused by LP or the tumor itself.


Assuntos
Hemangioblastoma , Fotocoagulação a Laser , Neoplasias da Retina , Tomografia de Coerência Óptica , Doença de von Hippel-Lindau , Humanos , Hemangioblastoma/cirurgia , Hemangioblastoma/diagnóstico por imagem , Masculino , Feminino , Doença de von Hippel-Lindau/complicações , Doença de von Hippel-Lindau/cirurgia , Fotocoagulação a Laser/métodos , Adulto , Tomografia de Coerência Óptica/métodos , Neoplasias da Retina/cirurgia , Neoplasias da Retina/diagnóstico por imagem , Neoplasias da Retina/patologia , Pessoa de Meia-Idade , Angiofluoresceinografia/métodos , Adulto Jovem , Resultado do Tratamento , Cirurgia Assistida por Computador/métodos
16.
Biomater Sci ; 12(15): 3765-3804, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-38961718

RESUMO

Surgery is one of the most important paradigms for tumor therapy, while fluorescence imaging (FI) offers real-time intraoperative guidance, greatly boosting treatment prognosis. The imaging fidelity heavily relies on not only imaging facilities but also probes for imaging-guided surgery (IGS). So far, a great number of IGS probes with emission in visible (400-700 nm) and near-infrared (NIR 700-1700 nm) windows have been developed for pinpointing disease margins intraoperatively. Herein, the state-of-the-art fluorescent probes for IGS are timely updated, with a special focus on the fluorescent probes under clinical examination. For a better demonstration of the superiority of NIR FI over visible FI, both imaging modalities are critically compared regarding signal-to-background ratio, penetration depth, resolution, tissue autofluorescence, photostability, and biocompatibility. Various types of fluorescence IGS have been summarized to demonstrate its importance in the medical field. Furthermore, the most recent progress of fluorescent probes in NIR-I and NIR-II windows is summarized. Finally, an outlook on multimodal imaging, FI beyond NIR-II, efficient tumor targeting, automated IGS, the use of AI and machine learning for designing fluorescent probes, and the fluorescence-guided da Vinci surgical system is given. We hope this review will stimulate interest among researchers in different areas and expedite the translation of fluorescent probes from bench to bedside.


Assuntos
Corantes Fluorescentes , Neoplasias , Imagem Óptica , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Corantes Fluorescentes/química , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Animais
17.
J Cardiothorac Surg ; 19(1): 454, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014445

RESUMO

BACKGROUND: The feasibility of percutaneous intramyocardial septal radiofrequency ablation (PIMSRA) for the treatment of hypertrophic obstructive cardiomyopathy (HOCM) has been previously reported. However, limited investigation has been conducted regarding the complications associated with this procedure. OBJECTIVE: This study aims to analyze the risk factors affecting the occurrence of complications during PIMSRA, such as pericardial effusion, ventricular premature beats, and interventricular septal perforation. In this study, the optimal cut-off values for these risk factors are also explored, and corresponding strategies for prevention are proposed. METHODS: A total of 101 patients diagnosed with HOCM who underwent the PIMSRA procedure from 2021 to 2022 were included in this retrospective analysis. Patients were classified into subgroups with or without complications based on procedural records. Univariate and multivariate regression analyses were conducted to identify independent risk factors for complications during the PIMSRA procedure. RESULTS: There were 48 patients with complications and 53 patients without complications. The heart rate at the start of the procedure and the maximum left ventricular outflow tract gradient (LVOTG) were independent risk factors related to PIMSRA complications. The optimal cut-off values for predicting complication occurrence were a heart rate > 49 bpm at the start of the procedure (OR: 3.79, 95% CI: 1.64-8.78, p = 0.002) and a maximum LVOTG > 92 mmHg (OR: 2.57, 95% CI: 1.15-5.75, p = 0.022), respectively. CONCLUSIONS: The occurrence of PIMSRA complications is primarily associated with the heart rate at the start of the procedure and the maximum LVOTG. It is recommended to establish a comprehensive control plan to minimize the risk of complications during PIMSRA procedures.


Assuntos
Cardiomiopatia Hipertrófica , Ecocardiografia , Humanos , Masculino , Feminino , Cardiomiopatia Hipertrófica/cirurgia , Estudos Retrospectivos , Pessoa de Meia-Idade , Fatores de Risco , Ecocardiografia/métodos , Septos Cardíacos/cirurgia , Septos Cardíacos/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Idoso , Ablação por Radiofrequência/efeitos adversos , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador/métodos
18.
Clin Oral Investig ; 28(8): 417, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38972945

RESUMO

OBJECTIVES: The treatment of fractures prioritizes the restoration of functionality through the realignment of fractured segments. Conventional methods, such as titanium plates, have been employed for this purpose; however, certain limitations have been observed, leading to the development of patient-specific plates. Furthermore, recent advancements in digital technology in dentistry enable the creation of virtual models and simulations of surgical procedures. The aim was to assess the clinical effectiveness of patient-specific plates utilizing digital technology in treating mandibular fractures compared to conventional titanium plates. MATERIALS AND METHODS: Twenty patients diagnosed with mandibular fractures were included and randomly assigned to either the study or control groups. The surgical procedure comprised reduction and internal fixation utilizing patient-specific plates generated through virtual surgery planning with digital models for the study group, while the control group underwent the same procedure with conventional titanium plates. Assessment criteria included the presence of malunion, infection, sensory disturbance, subjective occlusal disturbance and occlusal force in functional maximum intercuspation (MICP). Statistical analysis involved using the Chi-square test and one-way repeated measures analysis of variance. RESULTS: All parameters showed no statistically significant differences between the study and control groups, except for the enhancement in occlusal force in functional MICP, where a statistically significant difference was observed (p = 0.000). CONCLUSION: Using patient-specific plates using digital technology has demonstrated clinical effectiveness in treating mandibular fractures, offering advantages of time efficiency and benefits for less experienced surgeons. CLINICAL RELEVANCE: Patient-specific plates combined with digital technology can be clinically effective in mandibular fracture treatment.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas Mandibulares , Titânio , Humanos , Fraturas Mandibulares/cirurgia , Titânio/química , Masculino , Feminino , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Adulto , Resultado do Tratamento , Pessoa de Meia-Idade , Desenho Assistido por Computador , Cirurgia Assistida por Computador/métodos
19.
Nat Commun ; 15(1): 5832, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992020

RESUMO

While second near-infrared (NIR-II) fluorescence imaging is a promising tool for real-time surveillance of surgical operations, the previously reported organic NIR-II luminescent materials for in vivo imaging are predominantly activated by expensive lasers or X-ray with high power and poor illumination homogeneity, which significantly limits their clinical applications. Here we report a white-light activatable NIR-II organic imaging agent by taking advantages of the strong intramolecular/intermolecular D-A interactions of conjugated Y6CT molecules in nanoparticles (Y6CT-NPs), with the brightness of as high as 13315.1, which is over two times that of the brightest laser-activated NIR-II organic contrast agents reported thus far. Upon white-light activation, Y6CT-NPs can achieve not only in vivo imaging of hepatic ischemia reperfusion, but also real-time monitoring of kidney transplantation surgery. During the surgery, identification of the renal vasculature, post-reconstruction assessment of renal allograft vascular integrity, and blood supply analysis of the ureter can be vividly depicted by using Y6CT-NPs with high signal-to-noise ratios upon clinical laparoscopic LED white-light activation. Our work provides efficient molecular design guidelines towards white-light activatable imaging agent and highlights an opportunity for precision imaging theranostics.


Assuntos
Imagem Óptica , Cirurgia Assistida por Computador , Animais , Cirurgia Assistida por Computador/métodos , Camundongos , Imagem Óptica/métodos , Luz , Nanoestruturas/química , Transplante de Rim/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Nanopartículas/química , Raios Infravermelhos , Luminescência , Rim/diagnóstico por imagem , Rim/cirurgia , Masculino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Meios de Contraste/química
20.
Theranostics ; 14(9): 3634-3652, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38948059

RESUMO

Rationale: Molecular imaging of microenvironment by hypoxia-activatable fluorescence probes has emerged as an attractive approach to tumor diagnosis and image-guided treatment. Difficulties remain in its translational applications due to hypoxia heterogeneity in tumor microenvironments, making it challenging to image hypoxia as a reliable proxy of tumor distribution. Methods: We report a modularized theranostics platform to fluorescently visualize hypoxia via light-modulated signal compensation to overcome tumor heterogeneity, thereby serving as a diagnostic tool for image-guided surgical resection and photodynamic therapy. Specifically, the platform integrating dual modules of fluorescence indicator and photodynamic moderator using supramolecular host-guest self-assembly, which operates cooperatively as a cascaded "AND" logic gate. First, tumor enrichment and specific fluorescence turn-on in hypoxic regions were accessible via tumor receptors and cascaded microenvironment signals as simultaneous inputs of the "AND" gate. Second, image guidance by a lighted fluorescence module and light-mediated endogenous oxygen consumption of a photodynamic module as dual inputs of "AND" gate collaboratively enabled light-modulated signal compensation in situ, indicating homogeneity of enhanced hypoxia-related fluorescence signals throughout a tumor. Results: In in vitro and in vivo analyses, the biocompatible platform demonstrated several strengths including a capacity for dual tumor targeting to progressively facilitate specific fluorescence turn-on, selective signal compensation, imaging-time window extension conducive to precise normalized image-guided treatment, and the functionality of tumor glutathione depletion to improve photodynamic efficacy. Conclusion: The hypoxia-activatable, image-guided theranostic platform demonstrated excellent potential for overcoming hypoxia heterogeneity in tumors.


Assuntos
Imagem Óptica , Nanomedicina Teranóstica , Animais , Nanomedicina Teranóstica/métodos , Humanos , Imagem Óptica/métodos , Camundongos , Microambiente Tumoral , Linhagem Celular Tumoral , Corantes Fluorescentes/química , Fotoquimioterapia/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Camundongos Nus , Cirurgia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA