Resultados 1 - 20 de 24.539
Filtrar
1.
A A Pract ; 18(7): e01828, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39046154

RESUMO

The anesthesia gas scavenging system (AGSS) removes waste gases from the anesthesia machine. Within the AGSS, safety features prevent excessive pressures from affecting ventilation. Although the literature contains reports describing failures of the AGSS, we found no reports of positive-pressure relief valve (PPRV) malfunctions. We encountered 2 cases of extrinsic positive end-expiratory pressure (PEEP) resulting from a malfunctioning PPRV. Both cases suffered delayed identification intraoperatively but patients did not experience postoperative complications. These cases highlight the importance of daily scavenger system prechecks, the potential physiologic implications of AGSS malfunctions, and the importance of preplanned contingencies for machine failure.


Assuntos
Falha de Equipamento , Respiração com Pressão Positiva , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto
2.
BMC Cardiovasc Disord ; 24(1): 380, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39039491

RESUMO

INTRODUCTION: Cardiac implantable electronic device (CIED) complications present significant challenges in clinical practice, especially in elderly patients with multiple comorbidities. Common adverse events include infection, lead malfunction, and device migration. Twiddler's Syndrome, a rare but serious CIED complication characterised by patient manipulation causing lead displacement and device malfunction, is often underreported. The literature consists mainly of case reports and small series, providing limited guidance on prevention and management. As CIEDs are critical for managing cardiac arrhythmias and heart failure, understanding and addressing Twiddler's Syndrome is essential. This case report aims to contribute to the literature by detailing a case of Twiddler's Syndrome, emphasising the importance of a multidisciplinary approach for optimal management. CASE PRESENTATION: A 59-year-old male presented with discomfort around his implantable cardioverter defibrillator (ICD) site and the sternal area over the past two days. He denied pain, dyspnoea, or dizziness. Clinical examination revealed a normal heart rhythm and no peripheral pulse deficit. Ultrasound revealed a reduced left ventricular ejection fraction. The atrial lead was not visible, and the shock coil was misplaced. ICD interrogation showed inappropriate shocks due to sensing artifacts and exit block in both leads, with no arrhythmias detected. An X-ray confirmed lead dislodgement and significant entanglement in the pocket. The patient was diagnosed with Twiddler's Syndrome and scheduled for surgical revision. DISCUSSION/CONCLUSIONS: Dilated cardiomyopathy (DCM), characterised by left ventricular dilatation and dysfunction, accounts for a significant proportion of systolic heart failure cases. Despite advancements in heart failure management, DCM patients remain at high risk for sudden cardiac death (SCD), making ICD implantation crucial. However, CIED placement carries risks of complications, including Twiddler's Syndrome. This condition can lead to lead dislodgement and device malfunction, resulting in inappropriate shocks and potential patient harm. In this case, a single-session extraction and re-implantation were successfully performed using a multidisciplinary approach, emphasising the importance of comprehensive management strategies to address such complications effectively. Regular follow-up showed no adverse events, highlighting the procedure's success and the potential benefits of using advanced antimicrobial adjuncts to prevent infections. This case underscores the need for awareness and standardised protocols for managing Twiddler's Syndrome to improve patient outcomes in the growing population of CIED recipients.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Cardioversão Elétrica , Humanos , Masculino , Desfibriladores Implantáveis/efeitos adversos , Pessoa de Meia-Idade , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Resultado do Tratamento , Falha de Equipamento
3.
Biomed Phys Eng Express ; 10(5)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39013391

RESUMO

To date, a myriad of neural microelectrodes has been meticulously developed, but the focus of existing literature predominantly revolves around fabrication methodologies rather than delving into the reconditioning processes or strategies for salvaging electrodes exhibiting diminished performance due to material failure. This study aims to elucidate the underlying factors contributing to the degradation in performance of neural microelectrodes. Additionally, it introduces a comprehensive, cost-effective protocol for the reconditioning and repurposing of electrodes afflicted by material failure, tailored for a broad spectrum of electrode types. The efficacy of the proposed reconditioning protocol is substantiated through experimental validation on single-site tungsten microelectrodes. The results of neural signal recording unequivocally demonstrate the successful restoration of a substantial number of electrodes, underscoring the protocol's effectiveness.


Assuntos
Microeletrodos , Eletrodos Implantados , Encéfalo/fisiologia , Humanos , Animais , Neurônios/fisiologia , Desenho de Equipamento , Eletrofisiologia/métodos , Eletrofisiologia/instrumentação , Falha de Equipamento , Tungstênio
4.
BMC Pediatr ; 24(1): 441, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987700

RESUMO

Peripheral intravenous central catheter (PICC) is a common tool for intravenous infusion for children who need central venous access. Although it is safe for physicians and nurses to place, complications like infection, occlusion, phlebitis, and bleeding can occur. We report a 5-month-old infant who suffered respiratory failure caused by catheter malposition resulting in massive fluid infusion into the thoracic cavity. Point-of-care ultrasound (POCUS) was utilized to identify a massive pleural effusion that prompted urgent drainage. Complications related to PICC in pediatric patients are not common but difficult to immediately identify sometimes. Therefore, careful attention should be paid by physicians to identify and reduce the risk of complications associated with PICC. Thus, visual tools are strongly advised to enhance the safety of invasive procedures.


Assuntos
Cateterismo Periférico , Derrame Pleural , Atelectasia Pulmonar , Insuficiência Respiratória , Humanos , Lactente , Derrame Pleural/etiologia , Derrame Pleural/diagnóstico por imagem , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Atelectasia Pulmonar/etiologia , Atelectasia Pulmonar/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Masculino , Falha de Equipamento , Doença Aguda , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia
6.
Cochrane Database Syst Rev ; 6: CD013366, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940297

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems. OBJECTIVES: To assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH METHODS: The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS' CONCLUSIONS: There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Periférico , Desenho de Equipamento , Falha de Equipamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Tromboembolia Venosa , Humanos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Infecções Relacionadas a Cateter/prevenção & controle , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/etiologia , Obstrução do Cateter , Cateteres Venosos Centrais/efeitos adversos , Causas de Morte , Viés , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Bacteriemia/prevenção & controle , Bacteriemia/etiologia
7.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38885309

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Assuntos
Desfibriladores Implantáveis , Fontes de Energia Elétrica , Sistema de Registros , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Estados Unidos/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Europa (Continente)/epidemiologia , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Fatores de Tempo , Análise de Falha de Equipamento/estatística & dados numéricos , Adulto
8.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38861398

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Sistema de Registros , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Incidência , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Idoso , Europa (Continente)/epidemiologia , Falha de Equipamento/estatística & dados numéricos , Estados Unidos/epidemiologia , Fatores de Risco
9.
PLoS One ; 19(6): e0304652, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38941331

RESUMO

The reactor coolant pump is a key equipment in a nuclear power plant. If the leakage exceeds a certain threshold, it may cause reactor overheating and shutdown. The reactor coolant pump leakage fault usually has two problems: corrosion and scaling. Accurately and efficiently diagnosing the leakage fault mode as early as possible and predicting its remaining useful life (RUL) are important for taking timely maintenance measures. In this paper, an integrated method is proposed. First, the cross-sectional area of the first seal is extracted as a fault indicator. The motivation is that corrosion may enlarge the cross-sectional area, and scaling may reduce the cross-sectional area. Based on the fluid mechanics theory, an integrated model with several uncertain parameters is established among the cross-sectional area, temperature, and leakage at the inlet and outlet of the first seal. In the diagnosing process, a modified change-detection method is proposed to detect the starting point of degradation. Then, the unknown parameters in the previous relation are estimated, and the degrading data before the starting point of degradation are used to diagnose the leakage fault mode. Second, a time-series model of the autoregressive integrated moving average (ARIMA) is established to predict the remaining useful life based on the degrading data after the starting point of degradation. Finally, the leakage degrading data from six reactor coolant pumps of a nuclear power plant is used to perform the leakage fault mode diagnosis and life prediction with degradation point detection error rates not exceeding 4%, fault mode diagnosis correction rates 100% and practical RUL predicting results, which proves that the proposed integrated method is accurate and efficient. The proposed integrated method combines the advantages of both the physical model diagnosis and the data-driven model diagnosis and innovatively make use of the quantity of flow from the output side of the primary pump as the monitoring indicator and the cross-sectional area as the characteristic index together to diagnose the leakage fault mode happened to the seal and predict its RUL, which can meet the needs of actual operation and maintenance to ensure a healthy and stable operation of the pump and prevent unexpected shutdowns of nuclear power plants and serious accidents.


Assuntos
Centrais Nucleares , Modelos Teóricos , Reatores Nucleares , Falha de Equipamento , Análise de Falha de Equipamento
11.
Neurosurg Rev ; 47(1): 269, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864925

RESUMO

Ventriculoperitoneal shunt surgery was developed to manage excessive cerebrospinal fluid (CSF) in the brain's ventricles and is considered a mainstream treatment. Despite the development of the shunt device system, various complications still occur. In this study, we reported 307 cases and a long-term follow-up of at least five years of adult patients who underwent VP shunt surgery and analyzed various factors that may affect revision surgery. A retrospective study was conducted at Asan Medical Center, Korea, a tertiary medical center. We reviewed 307 cases from January 2012 to December 2018. The patients' neurological status, predisposing medical conditions, laboratory findings, and other operation-related factors were reviewed using electrical medical records. The normal function group comprised 272 cases (88.6%), and the overall incidence of revision group comprised 35 cases (11.4%). Of the 35 revision surgery cases, 30 (85.71%) were due to shunt malfunctions, such as obstruction, overdrainage, and valve-related errors while 5 (14.29%) were due to shunt infection. Patient demographics, mental status, and operation time did not influence revision as risk factors. Serum laboratory findings showed no statistical difference between the two groups. The white blood cell (WBC) count in the CSF profile differed significantly between the two groups. The Hakim Programmable valve (Codman, USA) is mainly used in our center. In addition, various shunt systems were used, including Strata Regulatory valve (Medtronic, USA), proGAV (Aesculap, USA), and Accu-Flo (Codman, USA). This study analyzed the factors affecting long-term outcomes. Based on these findings, efforts are needed to achieve more favorable outcomes in the future.


Assuntos
Hidrocefalia , Derivação Ventriculoperitoneal , Humanos , Derivação Ventriculoperitoneal/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Fatores de Risco , Adulto , Estudos Retrospectivos , Incidência , Idoso , Seguimentos , Hidrocefalia/cirurgia , Reoperação , Complicações Pós-Operatórias/epidemiologia , Falha de Equipamento , Adulto Jovem
12.
Neurosurg Focus ; 56(6): E12, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38823042

RESUMO

OBJECTIVE: The aim of this study was 1) to describe the rate of intrathecal baclofen (ITB)-associated complications at a large tertiary center, and 2) to evaluate the impact of patient-related factors on the likelihood of developing such complications. METHODS: A retrospective single-center study was carried out. A total of 301 eligible patients were included in the analysis. Univariate regression models were used to evaluate the impact of age, sex, diagnosis, ambulation status, modified Ashworth scale score, body mass index, diabetes status, and pain level on the likelihood of developing a device-related infection, pump malfunction, catheter malfunction, and other clinically significant complications. RESULTS: Overall, 27% of patients experienced an ITB-related complication. The most common complications included infection (6%, 18/301), pump malfunction (7.3%, 22/301), and catheter malfunction (14%, 42/301). The univariate analyses revealed that the patient's ambulatory status had a significant impact on the likelihood of developing a catheter-related malfunction. Furthermore, a trend toward significance was identified between patients' preoperative body mass index and device-related infection. Finally, the risk of suffering any ITB-related complications was statistically correlated with the number of years that had passed since the initial pump implantation. CONCLUSIONS: The authors' analysis reveals a previously underrecognized association between ambulatory status at the time of ITB pump implantation and the incidence of catheter-related complications, and confirms the impact of time since surgery on the risk of developing any ITB-related complication. The patient's age, sex, diagnosis, diabetes status, or pain level at baseline were not associated with the risk of complications. Collectively, these insights contribute novel information to the existing literature, providing practical value for physicians in guiding patient selection for ITB therapy.


Assuntos
Baclofeno , Bombas de Infusão Implantáveis , Injeções Espinhais , Relaxantes Musculares Centrais , Humanos , Baclofeno/administração & dosagem , Baclofeno/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Fatores de Risco , Bombas de Infusão Implantáveis/efeitos adversos , Relaxantes Musculares Centrais/administração & dosagem , Relaxantes Musculares Centrais/efeitos adversos , Injeções Espinhais/efeitos adversos , Idoso , Adulto Jovem , Espasticidade Muscular/tratamento farmacológico , Falha de Equipamento/estatística & dados numéricos , Adolescente
13.
Neurosurg Focus ; 56(6): E11, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38823047

RESUMO

OBJECTIVE: Intrathecal baclofen (ITB) pumps are commonly used in pediatric patients with cerebral palsy (CP) and medically refractory spasticity. However, catheter malfunction and associated risk factors are not well understood. The aim of this study was to examine potential risk factors for spinal catheter malfunction and characterize postoperative follow-up to understand the clinical consequences. METHODS: Patients who received ITB pump replacement or revision at Boston Children's Hospital between 2010 and 2023 were retrospectively reviewed. The spinal catheter revision cohort (SCRC) included patients whose spinal catheter was occluded requiring lumbar catheter revision. The second cohort included abdominal pump replacements only (APRC). Between-group comparisons and multivariable regression identified factors associated with catheter revision and postoperative outcomes. RESULTS: Forty-one (33.6%) patients underwent spinal catheter revision and were compared with 81 patients (66.4%) who underwent abdominal pump replacement only. Younger age at surgery and an elevated preoperative lower-extremity modified Ashworth scale grade were associated with spinal catheter revision (p < 0.05). Catheter model type, tip location, and history of spinal fusion were not associated with obstruction. Postoperatively, SCRC patients experienced a higher rate of infection (17.1%) relative to APRC patients (0%) within 30 days from their ITB pump replacement procedure (p < 0.05) and greater likelihood of subsequent ITB system removal compared with the APRC (24.4% vs 7.4%, p < 0.05). Although not differing preoperatively, SCRC patients had lower postoperative ITB doses when compared with the APRC group (median dose 143 vs 350 µg/day, p < 0.05) at hospital discharge and remained statistically different at the 6-month and 1-year follow-ups (p < 0.05). There were no postoperative differences in baclofen overdose, withdrawal, or median number of hospital readmissions within 30 days. Overall, 31.7% of spinal catheter revisions were unanticipated by the clinical team at time of surgery. CONCLUSIONS: Younger age at surgery and increased preoperative lower-extremity tone may be risk factors for catheter obstruction, resulting in a higher rate of postoperative infection and subsequent ITB pump removal compared with pump replacement alone. Spinal catheter occlusion can complicate revision or replacement procedures, especially when unanticipated. Routine clinical assessment may be inadequate for diagnosing insidious catheter malfunction. Catheter occlusion deserves further study, and routine assessment of catheter patency may be warranted to prevent suboptimal tone therapy.


Assuntos
Baclofeno , Paralisia Cerebral , Bombas de Infusão Implantáveis , Relaxantes Musculares Centrais , Humanos , Baclofeno/administração & dosagem , Baclofeno/efeitos adversos , Masculino , Feminino , Criança , Bombas de Infusão Implantáveis/efeitos adversos , Fatores de Risco , Relaxantes Musculares Centrais/administração & dosagem , Estudos Retrospectivos , Adolescente , Paralisia Cerebral/cirurgia , Paralisia Cerebral/complicações , Pré-Escolar , Espasticidade Muscular/tratamento farmacológico , Espasticidade Muscular/etiologia , Espasticidade Muscular/cirurgia , Reoperação/métodos , Injeções Espinhais/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Falha de Equipamento , Estudos de Coortes
14.
Radiol Cardiothorac Imaging ; 6(3): e230303, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38869431

RESUMO

Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events. Keywords: Cardiac Assist Devices, MRI, Cardiac Implantable Electronic Device Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos , Pessoa de Meia-Idade , Falha de Equipamento/estatística & dados numéricos
15.
Drug Discov Ther ; 18(3): 160-166, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38880602

RESUMO

Malnutrition is a common problem among hospitalized older patients. Peripheral parenteral nutrition (PN) can improve patient outcomes but can also lead to complications that affect future treatment. Older inpatients, in particular, are expected to be prone to these catheter-related complications. However, the impact of peripheral PN on older inpatients has been rarely investigated. In the current study, the impact of PN on short peripheral catheters (SPCs) was evaluated by comparing signs and symptoms at the time of catheter removal between 22 patients with PN and 27 without. In addition to external clinical assessment, sonographic investigations of the SPC site were performed. The prevalence of external signs and symptoms of complications was similar between the patients (all P > 0.05). However, subcutaneous edema was found by ultrasound in > 80% of patients with PN, compared with 55.6% of those without PN (P = 0.051). Unlike cases without PN, all patients with PN who presented with external signs and symptoms developed subcutaneous edema (P = 0.022). Multivariate analysis demonstrated that administration of PN was independently associated with subcutaneous edema (adjusted odds ratio = 6.88, 95% confidence interval = 1.083-75.486, P = 0.040). For several decades, phlebitis has been the primary focus of complications related to peripheral PN in clinical settings. However, our results imply that peripheral PN causes subcutaneous edema, which can lead to catheter failure in older inpatients. This study contributes to understanding the etiology of catheter failure during peripheral PN in this population.


Assuntos
Edema , Nutrição Parenteral , Humanos , Masculino , Idoso , Feminino , Edema/etiologia , Nutrição Parenteral/efeitos adversos , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Ultrassonografia , Pacientes Internados , Tela Subcutânea , Estudos Retrospectivos
16.
Ren Fail ; 46(2): 2369695, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38938162

RESUMO

BACKGROUND: This study aims to establish a simplified and effective animal model of catheter malfunction caused by omental wrapped using negative pressure suction. METHOD: The peritoneal dialysis catheter outlet was linked to a negative-pressure (0-75mmHg) suction pump to intensify the negative pressure. Different negative pressures were tested for model construction in vitro. In vivo, a model of peritoneal catheter malfunction caused by omental wrapped was constructed in five beagles after catheter placement. Catheter drainage conditions and related complications were monitored before and after the model establishment. RESULTS: In the vitro experiment, the overall success rate of constructed models was 90% (36/40). The total malfunction rate was higher in 62.5 mmHg (10/10) and 75 mmHg (10/10) than in 12.5 mmHg (8/10) and 37.5 mmHg (8/10). The outflow velocity of dialysate at 62.5 mmHg was significantly lower than that at 12.5 mmHg and 37.5 mmHg, without a statistically significant difference compared to 75 mmHg. In the in vivo experiment, catheter outflow velocity increased, and residual fluid volume decreased after omental wrapped (99.6 ± 6.7 ml/min vs. 32.6 ± 4.6 ml/min at initial five minutes, p < 0.0001; 69.2 ± 16.3 ml vs. 581.0 ± 109.4 ml, p < 0.001). And the outflow velocity was finally below 2 ml/min. No severe related complications (such as infection, organ damage, or bleeding) were observed through laparoscopic examination and dialysate tests seven days post-operation. CONCLUSION: Utilizing negative pressure suction to increase negative pressure around catheter tip is a simple, safe, and effective method for establishing an animal model of omental wrapped leading to catheter malfunction.


Assuntos
Falha de Equipamento , Omento , Diálise Peritoneal , Animais , Cães , Sucção/instrumentação , Diálise Peritoneal/instrumentação , Diálise Peritoneal/efeitos adversos , Cateteres de Demora/efeitos adversos , Modelos Animais de Doenças , Masculino , Modelos Animais
17.
J Cardiothorac Surg ; 19(1): 306, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38822410

RESUMO

Peripheral venous catheter fracture with cardiovascular embolization is a rare but potentially serious complication. Herein, we report a case of peripheral venous catheter fracture with embolization in right ventricle in a preterm infant. The catheter fragment was successfully removed by surgical procedure via median sternotomy under cardiopulmonary bypass(CPB).We hope this case will increase awareness of this rare complication and improve cannulation safety.


Assuntos
Cateterismo Periférico , Remoção de Dispositivo , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Cateterismo Periférico/métodos , Remoção de Dispositivo/métodos , Masculino , Falha de Equipamento , Ventrículos do Coração/cirurgia , Feminino
18.
Niger J Clin Pract ; 27(5): 678-681, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38842719

RESUMO

BACKGROUND: Tracheostomy is an important life-saving surgical procedure that could be used to secure the lower airway. It can however serve as a source of airway compromise when fragments from it are deposited. This condition must be diagnosed early enough, and appropriate intervention should be done to forestall potential morbidity and mortality. CASE REPORT: A 56-year-old tracheostomized patient presented to the accident and emergency department with a 4-hour history of sudden onset choking cough and labored breathing. The shaft of his tracheostomy tube (TT) was fractured and subsequently aspirated while he was attempting to remove and clean the inner tube that morning. He has used the TT for about 6 years and lost to follow-up clinic visits. The chest radiograph showed the metallic foreign body lodged within the trachea. He had an emergency rigid bronchoscopy via the tracheostomy stoma, and the object was retrieved. All respiratory symptoms subsequently resolved, and a check radiograph showed normal findings. CONCLUSION: Tracheostomy tube fracture and aspiration should be ruled out in every tracheostomized patient with sudden onset acute respiratory symptoms. Otolaryngologists must always emphasize the need for proper handling of TT, regular follow-up, and tube replacement when due.


Assuntos
Broncoscopia , Corpos Estranhos , Traqueostomia , Humanos , Corpos Estranhos/cirurgia , Corpos Estranhos/complicações , Masculino , Pessoa de Meia-Idade , Broncoscopia/métodos , Brônquios/lesões , Brônquios/diagnóstico por imagem , Falha de Equipamento , Obstrução das Vias Respiratórias/etiologia , Obstrução das Vias Respiratórias/cirurgia , Obstrução das Vias Respiratórias/diagnóstico
20.
World Neurosurg ; 187: e883-e889, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38734164

RESUMO

OBJECTIVE: This study aimed to investigate the causes of lumboperitoneal (LP) shunt failure and determine risk factors for lumbar catheter fracture. METHODS: We retrospectively investigated 149 patients who underwent LP shunting in our hospital between January 2012 and March 2023. Shunt reconstruction occurred in 22 patients (14.8%). Among these, cause of failure was lumbar catheter fracture in 5 (22.7%). Patient backgrounds, cause of LP shunt failure, surgical technique factors, and anatomical characteristics were extracted for comparative analysis and risk factors of lumbar catheter fracture were analyzed. RESULTS: Compared with the no reoperation group (n = 127), patients in the lumbar catheter fracture tended to be younger (63 ± 20 vs. 72 ± 11 years) and favorable neurologic status (modified Rankin scale score ≤2) after initial LP shunt; however, the differences were not significant. Lumbar lordosis was significantly higher in the lumbar catheter fracture group (52.7°± 14.8° vs. 37.1°± 12.3°; P = 0.0067). CONCLUSIONS: Excessive lumbar lordosis is a risk factor for lumbar catheter fracture in patients undergoing LP shunting. Younger age and higher level of postoperative activities of daily living might also be associated with lumbar catheter fracture.


Assuntos
Falha de Equipamento , Lordose , Vértebras Lombares , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Lordose/cirurgia , Estudos Retrospectivos , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Falha de Equipamento/estatística & dados numéricos , Idoso de 80 Anos ou mais , Derivações do Líquido Cefalorraquidiano/efeitos adversos , Adulto , Região Lombossacral/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia