Evaluacion diagnóstica de la dinámica cardíaca caótica fetal a partir de la evolución del sistema dinámico / Diagnostic evaluation of fetal chaotic cardiac dynamics from the evolution of the dynamic system
Prensa méd. argent
; 105(3): 110-118, may 2019. tab, fig
Article
em Es
| BINACIS, LILACS
| ID: biblio-1025204
Biblioteca responsável:
AR392.1
RESUMEN
Objetivo:
Desarrollar una nueva metodología física y matemática para diagnosticar la dinámica cardíaca caótica fetal a partir de atractores de la frecuencia cardíaca.Metodología:
Se realizó una inducción matemática con tres trazados de monitorias fetales; una reactiva sin dudas en su evaluación, una plana y una con pérdida aguda de bienestar fetal, para cada una de ellas se generó un atractor caótico a partir de las frecuencias cardíacas, se evaluaron los espacios de ocupación de cada atractor en dos rejillas, y se establacieron diferencias matemáticas entre trazados de monitorias reactivas y no reactivas. Posteriormente se analizaron otros 15 trazados de monitorias fetales, para refinar los parámetros diagnósticos.Resultados:
Los espacios evaluados para los atractores de monitorias normales presentaron valores entre 53 y 117 para la rejilla más pequeña; mientras que las monitorias anormales presentaron valores menores a 41 y mayores a 123.Conclusiones:
se desarrolló una nueva metodología de ayuda diagnóstica para evaluar la dinámica cardíaca caótica fetal, que diferencia normalidad de enfermedad de forma objetiva y reproducible (AU)ABSTRACT
Objective:
To develop a new physical and mathematical methodology to diagnose fetal chaotic cardiac dynamics from heart rate attractors.Methods:
A mathematical induction was performed with three fetal monitoring tracings;one of them, reactive without doubt in its evaluation, other plane and other with acute loss of fetal well-being, for each of them a chaotic attractor was generated from the cardiac frequencies, the spaces of occupation of each attractor in two grids were evaluated, and mathematical differences were established between reactive and non-reactive monitorin tracings. A further 15 fetal monitoring tracings were then analyzed to refine the diagnostic parameters.Results:
The spaces evaluated for the normal monitor attractors presented values between 53 and 177 for the smallest grid; while abnormal monitoring had values lower than 41 and greater than 12.3.conclusions:
a new methodology of diagnostic aid was developed to evaluate fetal chaotic cardiac dynamics, which distinguishes normality of disease in an objective and reproductible way (AU)Palavras-chave
Coleções:
01-internacional
Base de dados:
BINACIS
/
LILACS
Assunto principal:
Diagnóstico Pré-Natal
/
Dinâmica não Linear
/
Fractais
/
Metodologia como Assunto
/
Monitorização Fetal
/
Programas de Triagem Diagnóstica
Tipo de estudo:
Diagnostic_studies
Limite:
Female
/
Humans
/
Pregnancy
Idioma:
Es
Revista:
Prensa méd. argent
Assunto da revista:
MEDICINA
Ano de publicação:
2019
Tipo de documento:
Article
País de afiliação:
Colômbia
País de publicação:
Argentina