Your browser doesn't support javascript.
loading
Effect of Thermocycling on the Colour Stability of Aesthetic Restorative Materials: An in-vitro Spectrophotometric Analysis
Bhattacharya, Swastika; Purayil, Tina Puthen; Ginjupalli, Kishore; Kini, Sandya; Pai, Swathi.
Afiliação
  • Bhattacharya, Swastika; Manipal Academy of Higher Education. Manipal College of Dental Sciences. Department of Conservative Dentistry and Endodontics. Manipal. IN
  • Purayil, Tina Puthen; Manipal Academy of Higher Education. Manipal College of Dental Sciences. Department of Conservative Dentistry and Endodontics. Manipal. IN
  • Ginjupalli, Kishore; Manipal Academy of Higher Education. Manipal College of Dental Sciences. Department of Dental Materials. Manipal. IN
  • Kini, Sandya; Manipal Academy of Higher Education. Manipal College of Dental Sciences. Department of Conservative Dentistry and Endodontics. Manipal. IN
  • Pai, Swathi; Manipal Academy of Higher Education. Manipal College of Dental Sciences. Department of Conservative Dentistry and Endodontics. Manipal. IN
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1056885
Biblioteca responsável: BR1264.1
ABSTRACT
Abstract

Objective:

To compare the color stability of Cention N, Fuji IX GP Extra, and Fuji IX GP after thermocycling. Material and

Methods:

Ten discs of each material of dimension 10 x 1 mm were prepared using a split mold. The preparations of the specimens were done according to the powder/liquid ratio as recommended by the manufacturers [4.61, 3.41 and 3.61 for the groups I, II, and III, respectively]. After setting, the samples were retrieved, and the thickness of each specimen was measured using a micrometer at five different locations. The specimens with variations in thickness, porosity or cracks were discarded and thus not included in the study. The selected specimens were stored in distilled water for 24 hours prior to testing. The prepared specimens were thermocycled at 5°C and 55°C, with a dwell time of 15 seconds for 250 or 500 cycles. Subsequently, the color parameters of the discs were measured using a spectrophotometer. The data were analyzed using two way ANOVA test, and a p-value <0.001 was considered.

Results:

Thermocycling resulted in changes in the color of both Glass Ionomer cement and Cention N (p<0.001). Among the materials tested, Cention N showed superior color stability.

Conclusion:

Cention N exhibited better color stability compared to Glass ionomer cements.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Espectrofotometria / Materiais Dentários / Estética Dentária / Cimentos de Ionômeros de Vidro País/Região como assunto: Ásia Idioma: Inglês Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Índia Instituição/País de afiliação: Manipal Academy of Higher Education/IN

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Espectrofotometria / Materiais Dentários / Estética Dentária / Cimentos de Ionômeros de Vidro País/Região como assunto: Ásia Idioma: Inglês Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Índia Instituição/País de afiliação: Manipal Academy of Higher Education/IN
...