Your browser doesn't support javascript.
loading
Relación entre la medición sonográfica de los músculos recto femoral y vasto intermedio y los parámetros bioquímicos convencionales para valorar el estado nutricional en la unidad de cuidados intensivos / Relationship between the sonographic measurement of the rectus femoris and vastus intermedius muscles and the conventional biochemical parameters used to assess the nutritional status in the intensive care unit / Relação entre a medida ultrassonográfica dos músculos reto femoral e vasto intermédio com parâmetros bioquímicos convencionais para avaliação do estado nutricional na Unidade de Terapia Intensiva
Unidad Médica de Alta EspecialidadHernández Plata, Alma Erika; Unidad Médica de Alta EspecialidadGómez González, María Natalia; Unidad Médica de Alta EspecialidadSoriano Orozco, Raúl; Unidad Médica de Alta EspecialidadHernández, Martha Alicia; Unidad Médica de Alta EspecialidadGonzález Carrillo, Pedro Luis.
Afiliação
  • Unidad Médica de Alta EspecialidadHernández Plata, Alma Erika; Instituto Mexicano del Seguro Social. Centro Médico Nacional Bajío Núm. 1. Unidad Médica de Alta EspecialidadHernández Plata, Alma Erika. León. MX
  • Unidad Médica de Alta EspecialidadGómez González, María Natalia; Instituto Mexicano del Seguro Social. Centro Médico Nacional Bajío Núm. 1. Unidad Médica de Alta EspecialidadGómez González, María Natalia. León. MX
  • Unidad Médica de Alta EspecialidadSoriano Orozco, Raúl; Instituto Mexicano del Seguro Social. Centro Médico Nacional Bajío Núm. 1. Unidad Médica de Alta EspecialidadSoriano Orozco, Raúl. León. MX
  • Unidad Médica de Alta EspecialidadHernández, Martha Alicia; Instituto Mexicano del Seguro Social. Centro Médico Nacional Bajío Núm. 1. Unidad Médica de Alta EspecialidadHernández, Martha Alicia. León. MX
  • Unidad Médica de Alta EspecialidadGonzález Carrillo, Pedro Luis; Instituto Mexicano del Seguro Social. Centro Médico Nacional Bajío Núm. 1. Unidad Médica de Alta EspecialidadGonzález Carrillo, Pedro Luis. León. MX
Med. crít. (Col. Mex. Med. Crít.) ; 32(6): 351-358, nov.-dic. 2018. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1115002
Biblioteca responsável: MX1.1
RESUMEN
Resumen

Introducción:

La desnutrición en el paciente crítico se relaciona con mal pronóstico. Las pérdidas proteicas se identifican de manera convencional mediante parámetros bioquímicos. La masa muscular puede reflejar la reserva corporal de proteínas, su medición por medio de sonografía ha evidenciado una fuerte correlación para detección de alteraciones.

Objetivo:

Determinar la correlación de la medición sonográfica de los músculos Recto Femoral (RF) y Vasto Intermedio (VI), con los parámetros bioquímicos convencionales de valoración nutricional.

Métodos:

Se estudiaron 12 pacientes mayores de 18 años, que recibieron dieta enteral temprana. Se midieron los parámetros bioquímicos, simultáneamente con parámetros sonográficos a nivel de RF y VI en los días uno y siete. Se estableció correlación entre los parámetros bioquímicos y sonográficos significativos.

Resultados:

El parámetro bioquímico con mayor significancia estadística fue el Balance Nitrogenado Urinario (BNU) en muestra de orina de 24 horas (p=0.001). En mediciones sonográficas, el porcentaje de reducción muscular para RF y VI mostró mayor diferencia (p=0.001). En análisis de correlación, se obtuvo fuerte correlación entre BNU y RF (r=0.77) así como BNU y VI (r=0.76).

Conclusión:

Existe correlación entre las pérdidas proteicas medidas por BNU y el porcentaje de reducción de los músculos RF y VI medidos por sonografía.
ABSTRACT
Abstract

Introduction:

Malnutrition in critically ill patients is associated with poor prognosis. Protein losses are identified conventionally by biochemical parameters. The muscle mass can reflect the body protein reserve, its measurement by means of sonography has shown a strong correlation for the detection of alterations.

Objective:

To determine the correlation of the sonographic measurement of the Rectus Femoris (RF) and Vastus Intermedius (VI) muscles, with the conventional biochemical parameters of nutritional assessment.

Methods:

We studied 12 patients older than 18 years who received an early enteral diet. The biochemical parameters were measured, simultaneously with sonographic parameters at the level of RF and VI on days one and seven. Correlation was established between the significant biochemical and sonographic parameters.

Results:

The biochemical parameter with the greatest statistical significance was the Urinary Nitrogen Balance (UNB) in a 24-hour urine sample (p = 0.001). In sonographic measurements, the percentage of muscle reduction for RF and VI showed greater difference (p = 0.001). In correlation analysis, strong correlation was obtained between UNB and RF (r = 0.77) as UNB and VI (r = 0.76).

Conclusion:

There is a correlation between the protein losses measured by UNB and the percentage reduction of RF and VI muscles measured by sonography.
RESUMO
Resumo

Introdução:

A desnutrição em pacientes críticos está associada a um mau prognóstico. As perdas de proteína são identificadas convencionalmente por parâmetros bioquímicos. A massa muscular pode refletir a reserva protéica corporal, sua medida por meio da ultrassonografia tem mostrado uma forte correlação para a detecção de alterações.

Objetivo:

Determinar a correlação da medida ultrassonográfica dos músculos Reto Femoral (RF) e Vasto Intermediário (VI), com os parâmetros bioquímicos convencionais de avaliação nutricional.

Métodos:

Foram estudados 12 pacientes com mais de 18 anos que receberam dieta enteral precocemente. Os parâmetros bioquímicos foram mensurados simultaneamente com parâmetros ultrassonográficos ao nível de FR e VI nos dias um e sete. Foi estabelecida correlação entre os parâmetros bioquímicos e ultrassonográficos significativos.

Resultados:

O parâmetro bioquímico com maior significância estatística foi o Balanço de Nitrogênio Urinário (NBU) em uma amostra de urina de 24 horas (p = 0,001). Nas medidas ultrassonográficas, a porcentagem de redução muscular para FR e VI mostrou maior diferença (p = 0,001). Na análise de correlação, obteve-se forte correlação entre o BNU e FR (r = 0,77) e NBU e VI (r = 0,76).

Conclusão:

Existe uma correlação entre as perdas protéicas medidas pelo NBU e a redução percentual dos músculos RF e VI medida pela ultra-sonografia.

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Espanhol Revista: Med. crít. (Col. Mex. Med. Crít.) Assunto da revista: Cirurgia Geral / Oftalmologia / Ortopedia Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: México Instituição/País de afiliação: Instituto Mexicano del Seguro Social/MX
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Espanhol Revista: Med. crít. (Col. Mex. Med. Crít.) Assunto da revista: Cirurgia Geral / Oftalmologia / Ortopedia Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: México Instituição/País de afiliação: Instituto Mexicano del Seguro Social/MX
...