Your browser doesn't support javascript.
loading
Impeller geometry definition of the transventricular assist device
Andrade, Gustavo de; Horikawa, Oswaldo; Drigo, Evandro; Andrade, Aron; Cardoso, Jose.
Afiliação
  • Andrade, Gustavo de; Instituto Dante Pazzanese de Cardiologia. Polytechnic School of the University of São Paulo (EPUSP). São Paulo. BR
  • Horikawa, Oswaldo; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Drigo, Evandro; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Andrade, Aron; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Cardoso, Jose; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
Artif. organs ; 44(8): 803-810, Aug. 2020. ilus., tab., graf.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1123439
Biblioteca responsável: BR79.1
Localização: BR79.1
ABSTRACT
ABSTRACT According to the World Health Organization, cardiovascular disease is the number one cause of death worldwide, except Africa, where Acquired Immune Deficiency Syndrome is the leading cause of death. In this scenario, the ventricular assist device (VAD) remains the unique alternative to extend patient life until heart transplantation. At Dante Pazzanese Institute of Cardiology, the research and development of an axial flow VAD to be fully implantable within the heart was started. This pump, denominated Transventricular Assist Device (TVAD), can be surgically implanted through a small left intercostal incision in a minimally invasive manner. The goal of this work is to analyze the impeller geometries of the TVAD, to avoid high shear stresses in the fluid and aim for the best conditions to support the circulatory system using computational fluid dynamics and in vitro tests. Different rotor geometries were selected according to the literature; based on the results, the best rotor was elected. This rotor contains a pair of spiral blades of constant and relatively high pitch, which pumps liquid at a flow rate of 3 L/min at 73 mm Hg. It is also expected that this rotor presents a moderate hemolysis since the shear rate is acceptable.
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Brasil Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.8 Atingir a cobertura universal de saúde Base de dados: Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Bombas de Fluxo Axial Idioma: Inglês Revista: Artif. organs Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Dante Pazzanese de Cardiologia/BR

Texto completo: Disponível Coleções: Bases de dados nacionais / Brasil Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.8 Atingir a cobertura universal de saúde Base de dados: Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Bombas de Fluxo Axial Idioma: Inglês Revista: Artif. organs Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Dante Pazzanese de Cardiologia/BR
...