Your browser doesn't support javascript.
loading
Comparación de dos métodos comerciales para la determinación de la concentración mínima inhibitoria de meropenem en Klebsiella pneumoniae productora de carbapenemasa tipo KPC / Comparison of two commercial methods for determination of the minimum inhibitory meropenem concentration in KPC carbapenemase-producing Klebsiella pneumoniae
Soria-Segarra, Claudia; Berrezueta, María de Lourdes; Calderón, Josselyn; Villacís, José E; Soria-Segarra, Carmen; Quiñones, Dianelys.
Afiliação
  • Soria-Segarra, Claudia; Instituto Nacional de Investigación en Salud Pública Leopoldo Izquieta Pérez. Departamento de investigación, desarrollo e innovación. Guayaquil. EC
  • Berrezueta, María de Lourdes; Instituto Nacional de Investigación en Salud Pública Leopoldo Izquieta Pérez. Departamento de investigación, desarrollo e innovación. Guayaquil. EC
  • Calderón, Josselyn; Instituto Nacional de Investigación en Salud Pública Leopoldo Izquieta Pérez. Departamento de investigación, desarrollo e innovación. Guayaquil. EC
  • Villacís, José E; Instituto Nacional de Investigación en Salud Pública Leopoldo Izquieta Pérez. Departamento de investigación, desarrollo e innovación. Guayaquil. EC
  • Soria-Segarra, Carmen; Universidad Católica Santiago de Guayaquil. Facultad de Ciencias Médicas. EC
  • Quiñones, Dianelys; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
Rev. cuba. med. trop ; 72(3): e516, sept.-dic. 2020. tab
Artigo em Espanhol | CUMED, LILACS | ID: biblio-1156536
Biblioteca responsável: CU1.1
RESUMEN

Introducción:

El tratamiento de las infecciones por Klebsiella pneumoniae productora de carbapenemasa tipo KPC es complicado debido a las escasas opciones terapéuticas existentes, lo cual obliga a optimizar los esquemas terapéuticos disponibles.

Objetivo:

Determinar la concordancia de la tarjeta AST-N272 del Sistema Vitek 2 Compact y las tiras M.I.C.ETM Evaluator con la dilución en agar para la determinación de la concentración mínima inhibitoria del meropenem en Klebsiella pneumoniae productora de carbapenemasa tipo KPC.

Métodos:

Se estudiaron 53 aislados de K. pneumoniae bla KPC positivas no clonales, provenientes de hisopados rectales recolectados en diferentes unidades hospitalarias de Guayaquil, Ecuador, entre enero a junio de 2016. Se determinó la concentración mínima inhibitoria de meropenem por dilución en agar (método de referencia), así como por el sistema Vitek 2 Compact (AST-N272) y las tiras M.I.C.ETM. Se determinó la CMI 50, CMI 90 y la concordancia esencial.

Resultados:

El rango de la CMI de meropenem de los aislados estudiados fue de 1 a ≥ 32 µg/mL, con una CMI50= 4 µg/mL y una CMI90= ≥ 32 µg/mL. El 86,79 por ciento (n= 46) de los aislados tuvo una CMI≤ 8 µg/mL. Se observó un 94,33 por ciento de concordancia esencial con las tiras M.I.C.ETM, mientras que la tarjeta AST-N272 mostró una concordancia esencial inferior al 50 por ciento.

Conclusiones:

Los resultados sugieren posibles implicaciones en el tratataminto del paciente, pues reduce opciones terapéuticas en contextos de difícil manejo. Además, resaltan la necesidad de la confirmación de la resistencia a carbapenémicos mediante el método de Kirby Bawer en aquellos laboratorios que tienen métodos automatizados para estudios de susceptibilidad(AU)
ABSTRACT

Introduction:

The treatment for KPC carbapenemase-producing Klebsiella pneumoniae infections is complicated, due to the scant therapeutic options available, which forces us to optimize the therapies at hand.

Objective:

Determine the agreement between the AST-N272 card of the Vitek 2 Compact system and the M.I.C.E.TM Evaluator strips, and the agar dilution method for determination of the minimum inhibitory meropenem concentration in KPC carbapenemase-producing Klebsiella pneumoniae.

Methods:

A study was conducted of 53 positive non-clonal K. pneumoniae bla KPC isolates from rectal swabs collected at several hospitals in Guayaquil, Ecuador, from January to June 2016. Minimum inhibitory meropenem concentration was determined by agar dilution (reference method), the Vitek 2 Compact system (AST-N272) and M.I.C.E.TM strips. Determination was made of MIC 50, MIC 90 and essential agreement.

Results:

The meropenem MIC range for the isolates studied was 1 to ≥ 32 µg/ml, with MIC50= 4 µg/ml and MIC90= ≥ 32 µg/ml. In 86.79 percent (n= 46) of the isolates MIC was ≤ 8 µg/ml. Essential agreement was 94.33 percent with the M.I.C.E.TM strips and under 50 percent with the AST-N272 card.

Conclusions:

The results obtained suggest potential implications for the treatment of patients, since therapeutic options are reduced in difficult management contexts. They also highlight the need for confirmation of carbapenem resistance by the Kirby-Bauer procedure in laboratories equipped with automated methods for susceptibility studies(AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Doenças Negligenciadas / Zoonoses Base de dados: CUMED / LILACS Assunto principal: Testes de Sensibilidade Microbiana / Infecções por Enterobacteriaceae / Meropeném / Klebsiella pneumoniae Limite: Humanos País/Região como assunto: América do Sul / Equador Idioma: Espanhol Revista: Rev. cuba. med. trop Assunto da revista: Medicina Tropical Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Cuba / Equador Instituição/País de afiliação: Instituto Nacional de Investigación en Salud Pública Leopoldo Izquieta Pérez/EC / Instituto de Medicina Tropical Pedro Kourí/CU / Universidad Católica Santiago de Guayaquil/EC
Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Doenças Negligenciadas / Zoonoses Base de dados: CUMED / LILACS Assunto principal: Testes de Sensibilidade Microbiana / Infecções por Enterobacteriaceae / Meropeném / Klebsiella pneumoniae Limite: Humanos País/Região como assunto: América do Sul / Equador Idioma: Espanhol Revista: Rev. cuba. med. trop Assunto da revista: Medicina Tropical Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Cuba / Equador Instituição/País de afiliação: Instituto Nacional de Investigación en Salud Pública Leopoldo Izquieta Pérez/EC / Instituto de Medicina Tropical Pedro Kourí/CU / Universidad Católica Santiago de Guayaquil/EC
...