Evaluación del algoritmo de la Sociedad Europea de Cardiología de dolor torácico en pacientes con diabetes mellitus / Performance of the European Society of Cardiology Algorithm for the Assessment of Chest Pain in Patients with Diabetes Mellitus
Rev. argent. cardiol
; 88(6): 502-508, nov. 2020. tab, graf
Article
em Es
|
LILACS-Express
| LILACS
| ID: biblio-1251036
Biblioteca responsável:
AR1.1
RESUMEN
RESUMEN Introducción:
Dado que los pacientes con diabetes tienen habitualmente niveles de troponina más elevados que la población general, nos propusimos evaluar el comportamiento del algoritmo de la Sociedad Europea de Cardiología que utiliza la medición de troponina de alta sensibilidad al ingreso y 1 hora después en estos pacientes. Material ymétodos:
Se evaluaron 1140 pacientes que consultaron por dolor torácico con electrocardiograma sin supradesnivel del segmento ST. El algoritmo estratifica los pacientes en tres grupos de riesgo "externar", "observar" e "internar". Se valoró el comportamiento del algoritmo para el evento infarto a 30 d.Resultados:
En total, 124 pacientes (10,8%) tenían diabetes. Ninguno de los clasificados como "externar" (40,3%) presentó infarto a 30 días. En los "internar" (23,4%), el evento se produjo en el 82,8%, mientras que en el grupo "observar" (36,3%), en el 6,8%. La sensibilidad y el valor predictivo negativo fueron similares entre pacientes con diabetes y sin esta (100% vs. 98,5% p = 0,865 y 100% vs. 99,8% p = 0,44), pero la proporción de pacientes para "externar" fue menor en diabéticos (40,3% vs. 72,1%, p <0,001). En cuanto a la precisión para "internar" pacientes, la especificidad fue menor en diabéticos, pero el valor predictivo positivo fue mayor (90,9% vs. 97,2%, p <0,001 y 83% vs. 76%, p <0,001). La proporción de pacientes para "internar" fue mayor en diabéticos (23% vs. 8,6%, p <0,001).Conclusiones:
El uso del algoritmo en pacientes con diabetes mostró una alta sensibilidad y un alto valor predictivo negativo para "externar" comparable a la población general. En cuanto al grupo "internar", presentó menor especificidad, pero alto valor predictivo positivo. Esto lo transforma en una útil herramienta para la práctica diaria.ABSTRACT
ABSTRACT Background:
Patients with diabetes usually have higher troponin levels than the general population.Objective:
The aim of our study was to evaluate the performance of the European Society of Cardiology algorithm which uses high sensitivity cardiac troponin levels on admission and after 1 hour in these patients.Methods:
A total of 1,140 patients with chest pain and ECG without ST-segment elevation were evaluated. The algorithm stratifies patients in three risk groups rule-out, observe and rule-in. We evaluated the performance of the algorithm to predict myocardial infarction at 30 days.Results:
A total of 124 patients (10.8%) had diabetes. None of the patients in the rule-out group (40.3%) presented myocardial infarction at 30 days. In the rule-in group (23.4%), the event occurred in 82.8% of cases and in 6.8% in the observe group (36.3%). Sensitivity and negative predictive value were similar in patients with and without diabetes (100% vs. 98.5%, p= 0.865 and 100% vs. 99.8%, p=0.44), but the proportion of patients in the rule-out group was lower in diabetics (40.3% vs. 72.1%, p<0.001). The accuracy of the algorithm to rule in patients was evaluated by its specificity which was lower in diabetics, but the positive predictive value was greater (90.9% vs. 97.2%, p<0.001 and 83% vs. 76%, p<0.001). The proportion of patients in the rule-in group was higher in diabetics (23% vs. 8.6%, p<0.001).Conclusion:
The use of the algorithm in patients with diabetes revealed high sensitivity and negative predictive value to rule out, which was similar to that of the general population. Regarding the rule-in group, it had lower specificity but high positive predictive value. This performance makes the algorithm a useful tool for daily practice.
Acute coronary syndrome; Algorithms; Algoritmos; Chest pain; Diabetes mellitus; Diabetes mellitus; Dolor en el pecho; Infarto del miocardio sin elevación del ST; Non-ST elevated myocardial infarction; Sensibilidad y especificidad; Sensitivity and specificity; Síndrome coronario agudo; Troponin; Troponina
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Tipo de estudo:
Prognostic_studies
Idioma:
Es
Revista:
Rev. argent. cardiol
Assunto da revista:
CARDIOLOGIA
/
Doenas Cardiovasculares
Ano de publicação:
2020
Tipo de documento:
Article
País de afiliação:
Argentina
País de publicação:
Argentina