Your browser doesn't support javascript.
loading
Dexamethasone intravitreal implant for macular edema: a pilot study in a public health center
Crespo, Maria Júlia Izzo; Carbajo, Cristina Nery; Veiga, Glaucia Luciano da; Fonseca, Fernando Luiz Affonso; Lima, Vagner Loduca; Abucham Neto, Júlio Zaki.
Afiliação
  • Crespo, Maria Júlia Izzo; Centro Universitário FMABC. Discipline of Ophthalmology. Santo André. BR
  • Carbajo, Cristina Nery; Centro Universitário FMABC. Discipline of Ophthalmology. Santo André. BR
  • Veiga, Glaucia Luciano da; Centro Universitário FMABC. Discipline of Ophthalmology. Clinical Analysis Laboratory. Santo André. BR
  • Fonseca, Fernando Luiz Affonso; Universidade Federal de São Paulo. Department of Pharmaceutical Sciences. Diadema. BR
  • Lima, Vagner Loduca; Centro Universitário FMABC. Discipline of Ophthalmology. Santo André. BR
  • Abucham Neto, Júlio Zaki; Centro Universitário FMABC. Discipline of Ophthalmology. Santo André. BR
ABCS health sci ; 45(Supl. 3): e020104, 10 June 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1252373
Biblioteca responsável: BR1342.1
Localização: BR1342.1
ABSTRACT

INTRODUCTION:

Macula edema consists in one of the most common causes of visual impairment.

OBJECTIVE:

To evaluate the safety and efficacy of continuous release of 0.7 mg dexamethasone (using implantable device) for treatment of macular edema.

METHODS:

Cross-sectional observational study of 16 patients treated with 0.7 mg dexamethasone intraocular implant. Visual acuity, intraocular pressure and central macular thickness were recorded at baseline, 1-month and 3-month follow-up.

RESULTS:

15 eyes of 13 patients were included. Most eyes (n=9) improve visual acuity from baseline at 1-month follow-up; this improvement persisted through 3-monyh follow-up in six eyes. The central macular thickness decreased in the majority of the subjects at 1-month (n=12) and at 3-month (n=10) follow-up. Three eyes presented with elevated intraocular pressure.

CONCLUSION:

Dexamethasone implant can both reduce the risk of vision loss and improve anatomical features of macular edema due to several pathologies studied. This implant may be used safely and should be considered a therapeutic option to Brazilian Public Health System.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Dexametasona / Edema Macular / Injeções Intravítreas Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Inglês Revista: ABCS health sci Assunto da revista: Medicina / Saúde Pública Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário FMABC/BR / Universidade Federal de São Paulo/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Dexametasona / Edema Macular / Injeções Intravítreas Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Inglês Revista: ABCS health sci Assunto da revista: Medicina / Saúde Pública Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário FMABC/BR / Universidade Federal de São Paulo/BR
...