ABSTRACT
Aim:
The aim of this study was to compare the microtensile bond strength (µTBS) and the characteristics of the adhesive interface of Scotchbond Universal - SU etch-and-rise mode (3M ESPE) and Adper Scotchbond Multi-Purpose - MP (3M ESPE) to dentin over time.Methods:
Class I cavity preparations were performed in 60 human molars that were randomly divided according to the dentin bonding system (DBS) used (n=30) (1) Acid conditioning + SU and (2) Acid conditioning + MP. For bonding strength (BS) analysis, 30 teeth (n = 15) were sectioned into sticks and submitted to the microtensile test in a universal testing machine after 24 hours and 12 months. The adhesive interface of the others 30 teeth was analyzed in a confocal microscope after 24 hours and 12 months. The data of µTBS were analyzed by two-way repeated measures ANOVA and Tukey's HSD (α = 0.05).Results:
SU presented the lowest DBS compared to MP (p=0.000). Time did not influenced DBS for both adhesive systems (p=0.177). Confocal microscopy analysis showed no cracks between both adhesive systems tested.Conclusion:
The results indicate that MP - µTBS showed a better performance compared to SU in total-etch modePalavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
BBO
/
LILACS
Assunto principal:
Adesivos Dentinários
/
Microscopia Confocal
/
Dentina
/
Metacrilatos
Limite:
Humans
Idioma:
En
Revista:
Braz. j. oral sci
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2021
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil