Análise da deformação e caracterização de mini-implantes utilizados no MARPE (miniscrew-assisted rapid palatal expander) / Analysis of deformation and characterization of miniscrews used in MARPE (miniscrew-assisted rapid palatal expander)
Mueller, Tiago Augusto; Suzuki, Selly Sayuri; Suzuki, Hideo; Mueller, Roque José; Gruendling, Cesar Augusto; Segundo, Aguinaldo Silva Garcez.
Afiliação
  • Mueller, Tiago Augusto; SL Mandic. Departamento de Ortodontia. BR
  • Suzuki, Selly Sayuri; SL Mandic. Departamento de Ortodontia. BR
  • Suzuki, Hideo; SL Mandic. Departamento de Ortodontia. BR
  • Mueller, Roque José; Faculdade Herrero. Departamento de Ortodontia. BR
  • Gruendling, Cesar Augusto; Faculdade Herrero. Departamento de Ortodontia. BR
  • Segundo, Aguinaldo Silva Garcez; SL Mandic. Departamento de Ortodontia. BR
Ortho Sci., Orthod. sci. pract ; 15(58): 92-98, 2022. tab, ilus
Artigo em Português | BBO - Odontologia | ID: biblio-1380507
Biblioteca responsável: BR243.1
RESUMO
O objetivo deste trabalho foi analisar e caracterizar alterações estruturais e/ou deformações dos mini-implantes utilizados como ancoragem no disjuntor tipo MARPE (do inglês, Miniscrew-Assisted Rapid Palatal Expander). A amostra consistiu de quarenta e quatro mini-implantes (Peclab, Belo Horizonte/MG/Brasil) ­ comprimento 7mm, pescoço 4mm e diâmetro 1,8mm) usados como ancoragem no disjuntor tipo MARPE em pacientes com constrição maxilar necessitando de tratamento para expansão rápida da maxila. Os mini-implantes analisados permaneceram em um período estimado de quatro meses na boca. Além disso, outros quatro mini-implantes novos e não usados fabricados pela mesma empresa foram usados como grupo controle. A análise e caracterização da deformação morfológica foram realizadas utilizando microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva de raios-X (EDS). Em relação à caracterização dos mini-implantes no segmento pescoço, encontrou-se uma composição média de titânio 85,99%, alumínio 5,48%, vanádio 1,72%, carbono 4,74%, cromo 0,15%, oxigênio 1,82%, Na região do terço médio, foram encontrados titânio 82,37%, alumínio 5,33%, vanádio 1,89%, carbono 6,97%, cromo 0,11%, oxigênio 3,13%, enxofre 0,02%, ferro 0,08% e molibdênio 0,02%. Quando avaliada a deformação, segundo método proposto por Fujii (2013) variando do escore 0 (mínimo) à classificação 4 (máximo), foram observados os seguintes

resultados:

terço médio 1,70, ponta 1,56, cabeça 1,40 e pescoço 1,00. Nenhuma das amostras apresentou deformação ao longo do eixo dos mini-implantes. Um grande número de elementos na composição da liga foi detectado e as principais deformações foram de amassamento e edentação, principalmente, observados nos segmentos do terço médio e da ponta. (AU)
ABSTRACT
The aim of this work was to analyze and characterize structural changes and/or deformation of miniscrews used as anchorage for Miniscrew-Assisted Rapid Palatal Expander (MARPE). The sample consisted of forty-four miniscrews (Peclab, Belo Horizonte/MG/Brazil), length 7mm, neck 4mm and diameter 1.8mm used as MARPE anchorage in patients with maxillary con- striction requiring rapid maxillary expansion treatment. The miniscrews analyzed remained an estimated period of four months in mouth. In addition, other four new and unused miniscrews manufactured by the same company were used as control group. Morphologic deformation analysis and characterization were performed using scanning electron microscopy (SEM) and energy dispersive X-Ray spectroscopy (EDS). Regarding miniscrews characterization at the neck segment, it was found an average composition of titanium 85.99%, aluminum 5.48%, vanadium 1.72%, carbon 4.74%, chrome 0.15%, oxygen 1.82%. In the middle third region it was found titanium 82.37%, aluminum 5.33%, vanadium 1.89%, carbon 6.97%, chromium 0.11%, oxygen 3.13%, sulfur 0.02%, iron 0.08% and molybdenum 0.02%. When deformation was assessed, according to the method proposed by Fujii (2013) ranging from score 0 (minimum) to 4 (maximum), the following results were observed middle third 1.70, tip 1.56, head 1.40 and neck 1.00. None of the samples showed deformation along the miniscrews axis. A large number of elements in the alloy composition were detected and the major deformations were mainly kneading and edentation, observed at the middle third and tip segments. Descriptors Palatal expansion technique, orthodontic anchorage procedures, malocclusion.(AU)
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Técnica de Expansão Palatina / Procedimentos de Ancoragem Ortodôntica / Má Oclusão Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Faculdade Herrero/BR / SL Mandic/BR
Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Técnica de Expansão Palatina / Procedimentos de Ancoragem Ortodôntica / Má Oclusão Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Faculdade Herrero/BR / SL Mandic/BR
...