Your browser doesn't support javascript.
loading
Rotura aguda de prótesis valvular aórtica biológica Biocor® seis años después de su implante: reporte de un caso / Acute rupture a a Biocor® aortic valve prosthesis six years after implantation
Seguel, Enrique; Álvarez, Rodrigo; Alarcón, Emilio; Salazar, Daniela; Stockins, Aleck; González, Roberto.
Afiliação
  • Seguel, Enrique; Hospital Guillermo Grant Benavente de Concepción. Centro Cardiovascular. CL
  • Álvarez, Rodrigo; Hospital Guillermo Grant Benavente de Concepción. Centro Cardiovascular. CL
  • Alarcón, Emilio; Hospital Guillermo Grant Benavente de Concepción. Centro Cardiovascular. CL
  • Salazar, Daniela; Universidad de Concepción. CL
  • Stockins, Aleck; Hospital Guillermo Grant Benavente de Concepción. Centro Cardiovascular. CL
  • González, Roberto; Hospital Guillermo Grant Benavente de Concepción. Centro Cardiovascular. CL
Rev. chil. cardiol ; 39(3): 256-260, dic. 2020. ilus
Artigo em Espanhol | LILACS | ID: biblio-1388062
Biblioteca responsável: CL126.2
RESUMEN
Resumen Un hombre de 66 años portador de una prótesis valvular aórtica SJM Biocor® (Saint Jude Medical, St Paul, Minn), instalada 6 años antes, se presentó con disnea severa de rápida instalación. Mediante ecocardiografía de superficie y transesofágica se demostró insuficiencia aórtica masiva y el paciente fue reintervenido con éxito. En la operación se observó un desprendimiento parcial de la inserción del velo coronario izquierdo al anillo protésico. No había endocarditis. Se implantó una nueva prótesis biológica Trifecta® (Saint Jude Inc, St Paul, Minn) N°27. La evolución precoz y a 2 años de la intervención es muy satisfactoria.
ABSTRACT
Abstract A 66 year-old man with a SJM Biocor® (Saint Jude Medical, St Paul, Minn) implanted 6 years before developed unexpected severe dyspnea. Surface and transesophageal echocardiograms confirmed severe aortic regurgitation. The patient was rapidly re operated on. There was a partial detachment of the left coronary leaflet form the valve annulus. There was no evidence of endocarditis. A new valve (Trifecta® (Saint Jude Inc, St Paul, Minn) N°27). was inserted. Clinical course has been uneventful up to two years post surgery.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Insuficiência da Valva Aórtica / Ruptura Espontânea / Próteses Valvulares Cardíacas Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Rev. chil. cardiol Assunto da revista: Cardiologia Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Hospital Guillermo Grant Benavente de Concepción/CL / Universidad de Concepción/CL

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Insuficiência da Valva Aórtica / Ruptura Espontânea / Próteses Valvulares Cardíacas Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Rev. chil. cardiol Assunto da revista: Cardiologia Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Chile Instituição/País de afiliação: Hospital Guillermo Grant Benavente de Concepción/CL / Universidad de Concepción/CL
...