Your browser doesn't support javascript.
loading
Influence of abutment angulation on implant failure in immediately placed and restored implants in the esthetic zone: a randomized clinical trial
Fouad, Huda Fakhry; Elkhadem, Amr Hosny; Elkerdawy, Maha Wagdy; Elfar, Mahmoud Mokhtar.
Afiliação
  • Fouad, Huda Fakhry; Cairo University. Faculty of Dentistry. Prosthodontics Department. Cairo. EG
  • Elkhadem, Amr Hosny; Cairo University. Faculty of Dentistry. Prosthodontics Department. Cairo. EG
  • Elkerdawy, Maha Wagdy; Cairo University. Faculty of Dentistry. Prosthodontics Department. Cairo. EG
  • Elfar, Mahmoud Mokhtar; Cairo University. Faculty of Dentistry. Prosthodontics Department. Cairo. EG
Braz. j. oral sci ; 21: e226999, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1392965
Biblioteca responsável: BR218.1
ABSTRACT

Background:

Tooth extraction socket in the aesthetic area is a major indication for immediate implant placement greatly improving patient satisfaction and preserving the alveolar ridge. However, the effect of non-axial force on the peri-implant bone with subsequent early implant failure remains unclear.

Objective:

Evaluate the prognosis of tilted implants immediately placed and restored with angled abutments in comparison to straight implants restored with straight abutments in the esthetic area (anterior or premolars) using computer-aided surgical guides. Material and

methods:

Badly decayed non-restorable teeth in the aesthetic zone (anterior or premolars) were extracted atraumatically. Immediately after guided implant insertion, the abutments were adjusted and placed according to the allocation group (0, 15, or 25-degree angle) then a temporary crown was performed out of occlusion in centric and eccentric relation. Early implant failure was assessed at three and six months.

Results:

There was no statistically significant difference between the two groups (P=0.305). Straight and angled abutment groups showed 6 (14.3%) and 8 (20%) failed cases, respectively. The post-hoc subgroup analysis showed no statistically significant difference between angle 15 and angle 25 degree groups where (P=0.686) or between Anterior and Premolar groups (P=0.853).

Conclusion:

There was no statistically significant difference in the failure rate when comparing angled to straight immediately placed & restored implants. This applies to both anterior and premolar implants
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Prognóstico / Extração Dentária / Suporte de Carga / Falha de Restauração Dentária / Implantação Dentária / Carga Imediata em Implante Dentário Tipo de estudo: Ensaio clínico controlado / Estudo prognóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2022 Tipo de documento: Artigo País de afiliação: Egito Instituição/País de afiliação: Cairo University/EG

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Prognóstico / Extração Dentária / Suporte de Carga / Falha de Restauração Dentária / Implantação Dentária / Carga Imediata em Implante Dentário Tipo de estudo: Ensaio clínico controlado / Estudo prognóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2022 Tipo de documento: Artigo País de afiliação: Egito Instituição/País de afiliação: Cairo University/EG
...