Your browser doesn't support javascript.
loading
Assessment of influence of LED curing units used on microhardness of resin-modified glass ionomer sealants
Marques, Joyce Figueiredo de Lima; Ferraz, Laura Nobre; Lopes, Beatriz Kelly Barros; Vasconcelos, Tamires Aparecida Borges; Teixeira, Thiely Roberts; Lima, Débora Alves Nunes Leite; Aguiar, Flávio Henrique Baggio; Miranda, Diogo de Azevedo.
Afiliação
  • Marques, Joyce Figueiredo de Lima; University of Campinas. Piracicaba Dental School. Department of Restorative Dentistry. Piracicaba. BR
  • Ferraz, Laura Nobre; University of Campinas. Piracicaba Dental School. Department of Restorative Dentistry. Piracicaba. BR
  • Lopes, Beatriz Kelly Barros; Pontifical Catholic University of Minas Gerais. Department of Dentistry. Belo Horizonte. BR
  • Vasconcelos, Tamires Aparecida Borges; Pontifical Catholic University of Minas Gerais. Department of Dentistry. Belo Horizonte. BR
  • Teixeira, Thiely Roberts; Pontifical Catholic University of Minas Gerais. Department of Dentistry. Belo Horizonte. BR
  • Lima, Débora Alves Nunes Leite; University of Campinas. Piracicaba Dental School. Department of Restorative Dentistry. Piracicaba. BR
  • Aguiar, Flávio Henrique Baggio; University of Campinas. Piracicaba Dental School. Department of Restorative Dentistry. Piracicaba. BR
  • Miranda, Diogo de Azevedo; Pontifical Catholic University of Minas Gerais. Department of Dentistry. Belo Horizonte. BR
Braz. j. oral sci ; 21: e226202, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1393187
Biblioteca responsável: BR218.1
ABSTRACT

Aim:

Resin modified glass ionomer (RMGI) is class of material that can be used as sealant for preventing and arresting the progression of caries in pits and fissures. As these are hybrid materials, their properties can be affected by factors related to the polymerization process. Therefore, this study aimed to evaluate the influence of different generations of LED curing units (Elipar DeepCure-L and VALO Grand) on Knoop microhardness values (KHN) of RMGI sealants (Clinpro XT and Vitremer).

Methods:

Forty cylindrical specimens (6mm ø x 1 mm high) were prepared according to the manufacturer's instructions and divided into four groups (n=10) according to the type of RMGI and LED used. The KHN of the top surface of each sample was calculated 7 days after light-curing. Data were submitted to two-way ANOVA (α = 0.05).

Results:

Vitremer had higher KHN values than Clinpro XT after using both LEDs (p<0.0001), but especially when light-cured with the use of VALO Grand (p<0.0001). Whereas the KHN value of Clinpro was not influenced by the LED device (p>0.05).

Conclusions:

Top surface microhardness values of RGMI sealants were affected by both material composition and generations of LED curing units used. Third generation LED curing units seemed to be more efficient for the polymerization of RMGI-based sealants
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Selantes de Fossas e Fissuras / Luzes de Cura Dentária / Polimerização / Dureza Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2022 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Pontifical Catholic University of Minas Gerais/BR / University of Campinas/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Selantes de Fossas e Fissuras / Luzes de Cura Dentária / Polimerização / Dureza Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2022 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Pontifical Catholic University of Minas Gerais/BR / University of Campinas/BR
...