Tratamiento mínimamente invasivo/percutáneo de fracturas de pilón tibial con asistencia artroscópica en Hospital Regional de Talca / Minimally invasive/percutaneous treatment of tibial pilon fractures with arthroscopic assistance at the Regional Hospital
Rev. méd. Maule
; 37(2): 28-36, dic. 2022. tab, ilus
Article
em Es
| LILACS
| ID: biblio-1428070
Biblioteca responsável:
CL1.1
ABSTRACT
Tibial pilon fractures are a complex injury to treat due to the great involvement of soft and bone tissues. The classic surgical treatment is based on open reduction with internal fixation (ORIF), adding morbidity to the soft tissues, increasing the risk of complications. This has motivated the development of minimally invasive and/or percutaneous techniques to reduce complications, and with the advent of arthroscopy, achieve anatomical reductions. METHODS:
A retrospective observational study of twelve patients with tibial pilon fractures who were treated in our center with minimally invasive and/ or percutaneous osteosynthesis with arthroscopic support was carried out between January 2019 and June 2021. Fractures were characterized using the AO/OTA classification for tibial pilon. Age, sex, fracture mechanism, exposure and initial management in the emergency department (cast immobilization or external fixation), definitive treatment, complications and clinical and functional evaluation twelve months after definitive osteosynthesis. For this last point, plantar flexion, dorsiflexion and the AOFAS and FAOS Score were measured.RESULTS:
The operated patients were 12, 8 were men (67%) and 4 were women (33%). The average age was 49 (17-68) years. The definitive treatment was carried out after an average of 8 days (5-12 days). Surgical treatment schemes were as follows percutaneous osteosynthesis with medial anatomical plate and arthroscopic support (OPAA), minimally invasive osteosynthesis with cannulated screws and arthroscopic support (OMIAA) and osteosynthesis with external circular guide and arthroscopic support (OTCAA). In the AOFAS Score, three patients had excellent results (≥ 90 points), 6 patients had good results (≥ 80 points) and 3 patients had acceptable results (≥ 70 points). In the FAOS Score, eight patients had over 80% (good results) and 4 patients had over 60% (accep - table results).DISCUSSION:
Historically, tibial pilon fractures have been considered non-reconstructable and with poor long-term results. Initially this paradigm changed with the principles of Rüedi for the reconstruction of the tibial pilon and improve the results. ORIF has been widely used until today, it allows achieving an anatomical joint reduction, it allows to give stability and length to the fibula, graft contribution and sta - bilization with the medial plate. Today this concept is changing again, since the emphasis is on the care of the soft tissues to allow a better recovery of the patient and reduce the complications of the classic approach, it is in this context that the appearance of minimally invasive and/or percutaneous techniques with arthroscopic assistance has allowed us to have excellent functional and clinical results with less da - mage to the soft tissues.CONCLUSION:
The proper management and care of the soft tissues in a high-energy fracture of the tibial pilon is essential to obtain favorable clinical results and thus achieve restoration of ankle function. Percutaneous and minimally invasive management has optimized management of the tibial pilon, redu - cing the rates of complications, amputation, and pri - mary arthrodesis.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Fraturas da Tíbia
/
Procedimentos Cirúrgicos Minimamente Invasivos
/
Fixação Interna de Fraturas
Tipo de estudo:
Observational_studies
/
Qualitative_research
/
Risk_factors_studies
Limite:
Adolescent
/
Adult
/
Aged
/
Female
/
Humans
/
Male
Idioma:
Es
Revista:
Rev. méd. Maule
Assunto da revista:
MEDICINA
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
Chile
País de publicação: