Métodos de avaliação da gordura corporal e análise da ferramenta de ultrassonografia em pacientes obesos / Methods for evaluating body fat and analyzing the ultrasonography tool in obese patients / Métodos para evaluar la grasa y el análisis de la herramienta ultrasonográfica en pacientes obesos
Silva, Priscila Maia Ferreira; Souza, Yan Lucas Leal de; Santos, Alisson Vinícius dos; Xemenes, Rosana Christine Cavalcanti.
Afiliação
  • Silva, Priscila Maia Ferreira; Universidade Federal de Pernambuco.
  • Souza, Yan Lucas Leal de; Centro Universitário Brasileiro.
  • Santos, Alisson Vinícius dos; Universidade Federal de Pernambuco.
  • Xemenes, Rosana Christine Cavalcanti; Universidade Federal de Pernambuco.
Arq. ciências saúde UNIPAR ; 27(8): 4742-4753, 2023.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1444695
Biblioteca responsável: BR1532.9
RESUMO

Objetivo:

Analisar a tecnologia de ultrassonografia na avaliação da gordura corporal em pacientes obesos.

Metodologia:

Tratou-se de um estudo descritivo, transversal, onde participou da pesquisa um total de 50 pacientes com IMC a partir de 25 kg/m², sendo realizada a aferição do peso e estatura, visando à definição do IMC, além da avaliação da composição corporal através dos métodos de dobras cutâneas e ultrassom, possibilitando a comparação entre os resultados.

Resultado:

Foi observada uma forte correlação entre os resultados obtidos através de ambos os métodos (r=0,942; p valor <0,001), através do teste de qui-quadrado de Pearson, representando uma equiparação acerca de suas precisões. Além disso, foi observada uma moderada correlação entre o IMC e a aferição da composição corporal pelo método do ultrassom, demonstrando a imprecisão do IMC como método de diagnóstico do estado nutricional.

Conclusão:

A utilização da tecnologia do ultrassom para avaliação da composição corporal de pacientes com sobrepeso ou obesidade é um método de grande viabilidade.
ABSTRACT

Objective:

To analyze ultrasound technology in the evaluation of body fat in obese patients.

Methodology:

This was a descriptive, cross-sectional study, where a total of 50 patients with BMI from 25 kg/m² participated in the study, and weight and height were measured, aiming at the definition of BMI, besides the evaluation of body composition through the methods of skin folds and ultrasound, allowing comparison between the results.

Result:

A strong correlation was observed between the results obtained using both methods (r=0.942; p value <0.001), using Pearson's chi-square test, representing a comparison about their accuracy. In addition, a moderate correlation between BMI and body composition was observed by the ultrasound method, demonstrating the inaccuracy of BMI as a method of diagnosing nutritional status.

Conclusion:

The use of ultrasound technology to evaluate the body composition of overweight or obese patients is a highly viable method.
RESUMEN
Propósito analizar la tecnología de ultrasonido en la evaluación de la grasa corporal en pacientes obesos.

Metodología:

Se trata de un estudio descriptivo, transversal, en el que se incluyó un total de 50 pacientes con IMC a partir de 25 kg/m², con medición de peso y altura, con el fin de definir el IMC, además de la evaluación de la composición corporal a través de los métodos de plegado de la piel y ultrasonidos, haciendo posible comparar los resultados.

Resultado:

se observó una fuerte correlación entre los resultados obtenidos por ambos métodos (r=0,942; p value <0,001) a través de la prueba qui-square Pearson, lo que representa una similitud de su exactitud. Además, se observó una correlación moderada entre el IMC y la medición de la composición corporal mediante el método de ultrasonido, demostrando la imprecisión del IMC como método para diagnosticar el estado nutricional.

Conclusión:

El uso de la tecnología de ultrasonido para evaluar la composición corporal de pacientes con sobrepeso u obesidad es un método altamente viable.
Licença


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo observacional Idioma: Português Revista: Arq. ciências saúde UNIPAR Assunto da revista: Ciˆncias da Sa£de / Medicina / Pesquisa Biom‚dica Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Brasil

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo observacional Idioma: Português Revista: Arq. ciências saúde UNIPAR Assunto da revista: Ciˆncias da Sa£de / Medicina / Pesquisa Biom‚dica Ano de publicação: 2023 Tipo de documento: Artigo País de afiliação: Brasil
...