Caracterización de los derrames pleurales y ascíticos mediante la concentración de proteínas, comparación con los criterios actuales / Characterization of pleural and ascites effusions using concentration of their proteins and their comparison with current criteria
Rev. cuba. reumatol
; 24(4)dic. 2022.
Article
em Es
| LILACS, CUMED
| ID: biblio-1530169
Biblioteca responsável:
CU1.1
RESUMEN
Introducción:
Los líquidos serosos se clasifican tradicionalmente en exudados/trasudados según la concentración de proteínas y otros criterios que presentan un gran margen de error. Posteriormente se ensayan criterios por separado en 1972 Light y otros para los líquidos pleurales y en 1992 el criterio de Runyon para los líquidos ascíticos, con sensibilidades respectivas del 98 % y 97 %. Hoy se sigue aplicando el criterio primario con un error hasta del 40 %.Objetivo:
Identificar el margen de error en la clasificación de los líquidos pleurales y ascíticos cuando se emplea el criterio clásico (Starling), respecto a los criterios actuales de Light y Runyon utilizando reactivos de producción nacional.Métodos:
Se estudiaron 185 muestras de líquidos (121 pleurales y 64 ascíticos) en el periodo de los años 2017-2022 en el Hospital Clínico Quirúrgico Docente Miguel Enríquez de La Habana.Resultados:
Se encontraron discordancias en la clasificación de exudados/trasudados de los líquidos empleando los diferentes métodos de diferenciación, importantes en la clínica. Empleando el criterio clásico de las proteínas de Starling, el 9,1 % y el 17,2 % de los derrames pleurales y ascíticos, respectivamente, tuvo errores en su clasificación como exudado o trasudado.Conclusión:
El margen de error en la clasificación de los líquidos pleurales y ascíticos osciló entre un 9-17 % cuando se emplea el criterio clásico de las proteínas (Starling), respecto a los criterios actuales de Light y Runyon.ABSTRACT
Introduction:
Serous fluids are classified as exudates/ transudates based on protein concentration and other criteria that have a large margin of error. Subsequently, criteria were tested separately for pleural fluids in 1972 by Light et al and for ascitic fluids in 1992 the Runyon criteria with respective sensitivities of 98 % for the first and 97 % for the second. Currently, the primary criterion continues to be applied with an error of up to 40 %.Objective:
To identify the margin of error in the classification of pleural and ascitic fluids when using the classical criteria (Starling) with respect to the current criteria of Light and Runyon using nationally produced reagents.Methods:
185 fluid samples were studied - 121 pleural and 64 ascitic - in the period 2017/2022 at the Miguel Enriquez Clinical Surgical Teaching Hospital in Havana.Results:
Discordances were found in the classification of exudates / transudates of liquids using the different differentiation methods, important in the clinical diagnosis, concluding that using the classic criterion of Starling proteins, 9,1 % and 17,2 % of the pleural and ascitic effusions had errors in their classification as exudate and/or transudate.Conclusion:
The margin of error in the classification of pleural and ascitic fluids ranged from 9-17% when the classical criteria of proteins (Starling) is used with respect to the current criteria of Light and Runyon.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
CUMED
/
LILACS
Tipo de estudo:
Prognostic_studies
Limite:
Humans
Idioma:
Es
Revista:
Rev. cuba. reumatol
Assunto da revista:
MEDICINA
Ano de publicação:
2022
Tipo de documento:
Article
País de publicação:
Cuba