Your browser doesn't support javascript.
loading
Accuracy of mandibular measurements of sexual dimorphism using stabilizer equipment
LOPEZ, Thais Torralbo; MICHEL-CROSATO, Edgard; BENEDICTO, Eduardo de Novaes; PAIVA, Luiz Airton Saavedra de; SILVA, Diogo Cesar Borges; BIAZEVIC, Maria Gabriela Haye.
Afiliação
  • LOPEZ, Thais Torralbo; Universidade de São Paulo. School of Dentistry. Department of Community Dentistry. São Paulo. BR
  • MICHEL-CROSATO, Edgard; Universidade de São Paulo. School of Dentistry. Department of Community Dentistry. São Paulo. BR
  • BENEDICTO, Eduardo de Novaes; Universidade de São Paulo. School of Dentistry. Department of Community Dentistry. São Paulo. BR
  • PAIVA, Luiz Airton Saavedra de; Universidade de São Paulo. School of Dentistry. Department of Community Dentistry. São Paulo. BR
  • SILVA, Diogo Cesar Borges; Universidade de São Paulo. School of Dentistry. Department of Community Dentistry. São Paulo. BR
  • BIAZEVIC, Maria Gabriela Haye; Universidade de São Paulo. School of Dentistry. Department of Community Dentistry. São Paulo. BR
Braz. oral res. (Online) ; 31: e1, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839501
Biblioteca responsável: BR1.1
ABSTRACT
Abstract The objective of this investigation was to compare the accuracy of mandibular measurements using a stabilizer (MS) with gold standard computed tomography (GS) images. Sixty mandibles were studied. Werth TomoScope HV Compact® was used to obtain CT images (GS), and the MS was also used. Analysis of the CT scans was performed using the VG Studio Max software® (Volume Graphics GmbH, Heidelberg, Germany), and MS was used after the proper positioning of the mandible. Descriptive and paired t test measures were used, and a ROC curve was calculated, as well as sensibility and specificity. MedCalc and STATA 13.0® were used (95% level of significance). Bicondylar breadth, bicoronoid breadth and minimum ramus breadth reached the highest concordance correlation coefficients at 0.99 (0.99-1.00), 0.99 (0.99–1.00) and 1.00 (0.99–1.00), respectively. Comparing observers with GS, the lowest accuracy was noted for the maximum mandibular length [0.59 (0.45–0.69), 0.64 (0.51–0.74)], the breadth of the right (0.14 (0.04–0.23), 0.14 (0.004–0.24)) and left mandibular body [0.14 (0.03–0.24), 0.16 (0.05-0.26)], and the right [0.58 (0.45–0.69), 0.63 (0.51–0.73) and left (0.59 (0.45–0.70), 0.59 (0.46–0.69)] mandibular angle. Various measurements exhibited good sensibility for males using MS: maximum mandibular length (78.12), bicondylar breadth (78.12), left mandibular notch breadth (84.37), and the left height of the mandibular body at the mental foramen (75.00). High specificity in discriminating females was observed for the left maximal ramus height (85.19), mandibular length (85.71), bicoronoid breadth (96.43), right height of the mandibular body at the mental foramen (82.19), bimental breadth (78.57), breadth right (92.86) and left (96.43) mandibular body, minimum ramus breadth (89.29), and left mandibular angle (85.71). MS was able to discriminate sexual dimorphism.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tomografia Computadorizada por Raios X / Tomógrafos Computadorizados / Caracteres Sexuais / Mandíbula Tipo de estudo: Estudo prognóstico Limite: Adolescente / Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Tomografia Computadorizada por Raios X / Tomógrafos Computadorizados / Caracteres Sexuais / Mandíbula Tipo de estudo: Estudo prognóstico Limite: Adolescente / Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2017 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR
...