ABSTRACT
To determine the precision and accuracy of three-dimensional (3D) volume rendering spiral multislice computed tomography (CT)-based linear measurements of the mental foramen for dental implants, in vitro, and their precision, in vivo.

Methods:

Five cadaver heads were imaged by multislice spiral CT (Toshiba Aquilion) with 0.5mm thick axial slices (0.5 mm0.5 s of table feed) at 0.5 mm interval reconstructions. The image data sets were transferred to a networked computer workstation. Using computer graphics the data were analysed with a 3D volume rendering technique using Vitrea software. Two oral and maxillofacial radiologists, independently, made eletronic linear measurements from the superior border of the mental foramen to the crest of the alveolar process. The soft tissues were removed and physical measurements made using a 3 [Space POT. TM[ (Polhemus, Colchester, VT, USA) electromagnetic digitizer with a personal computer running Windows 98. The same linear measurements of 15 patients using the same imaging methodology were performed and the precision was analysed.

Results:

The findings showed no statistically significant inter- or intra-observer differences in vitro and in vivo, or between imaging and physical measurements in vitro (P > 0.05).

Conclusions:

3D multislice spiral CT imaging allows highly accurate measurements for dental implant placement in proximity to the mental foramen. Computer graphics software, using volume rendering is suitable for implant planning
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Implantes Dentários / Mandíbula Idioma: Português Revista: Dentomaxillofac. radiol Ano de publicação: 2002 Tipo de documento: Artigo
Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Implantes Dentários / Mandíbula Idioma: Português Revista: Dentomaxillofac. radiol Ano de publicação: 2002 Tipo de documento: Artigo
...