Your browser doesn't support javascript.
loading
Corrosion resistance of Ni-Cr alloys in different mouthwashes / Resistência à corrosão de ligas de Ni-Cr em diferentes enxaguatórios bucais
Alves-Rezende, Maria Cristina Rosifini; Grandini, Carlos Roberto; Dekon, Stefan Fiúza de Carvalho; Bertoz, André Pinheiro de Maganhães; Dutra, Conceição Aparecida Matsumoto; Codaro, Eduardo Norberto; Alves-Claro, Ana Paula Rosifini.
Afiliação
  • Alves-Rezende, Maria Cristina Rosifini; s.af
  • Grandini, Carlos Roberto; s.af
  • Dekon, Stefan Fiúza de Carvalho; s.af
  • Bertoz, André Pinheiro de Maganhães; s.af
  • Dutra, Conceição Aparecida Matsumoto; s.af
  • Codaro, Eduardo Norberto; s.af
  • Alves-Claro, Ana Paula Rosifini; s.af
Rev. Odontol. Araçatuba (Impr.) ; 32(1): 22-25, jan.-jun. 2011. ilus, tab, graf
Artigo em Inglês | BBO - Odontologia | ID: biblio-856898
Biblioteca responsável: BR186.1
Localização: BR186.1
RESUMO
Várias ligas têm sido utilizadas na confecção de restaurações protéticas nos últimos anos. Essas ligas apresentam na sua composição ouro, paládio, prata, níquel, cobalto, cromo e titânio; quando na cavidade bucal são passíveis de corrosão, a qual pode empobrecer a estética e comprometer as propriedades físicas e biológicas. O objetivo deste trabalho foi avaliar a resistência a corrosão de duas ligas odontológicas, Ni-Cr e Ni-Cr-Ti em três tipos de colutórios bucais com diferentes ingredientes ativos colutório I – 0.5g/l de cloreto de cetilpiridíneo +0.05 de fluoreto de sódio; colutório II -0.05 de fluoreto de sódio + 0.03% de triclosan e colutório III – 0.12% de diclonato de clorexidina. Curvas potenciodinâmicas foram realizadas por meio de potenciostato PAR283 e célula de vidro convencional de parede dupla para termostatização. Utilizou-se eletrodo de referência Ag/ AgCl, KClsat e auxiliar espiral de platina. A microestrutura das duas ligas foi observada por meio de microscopia ótica. Análise das curvas obtidas mostraram que a liga Ni-Cr foi menos reativa na presença de digluconato de clorexida a 0.12%, enquanto a liga Ni-Cr-Ti foi mais sensível para os outros dois tipos de colutório. Isto ocorreu, provavelmente, devido a presença de titânio na composição desta liga. Análise microestrutural revelou microsestrutura dendrítica na liga Ni-Cr e eutéticos na liga Ni-Cr-Ti
ABSTRACT
Several alloys have been used for prosthodontics restorations in the last years. These alloys have a number of metals that include gold, palladium, silver, nickel, cobalt, chromium and titanium and they are used in oral cavity undergo several corrosion. Corrosion can lead to poor esthetics, compromise of physical properties, or increased biological irritation. The objective of this study was evaluated corrosion resistance of two alloys Ni-Cr and Ni-Cr-Ti in three types of mouthwashes with different active ingredients 0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride, 0.05% sodium fluoride + 0.03% triclosan (with fluor) and 0.12% chlorohexidine digluconate. The potentiodynamic curves were performed by means of an EG&G PAR 283 potentiostat/galvanostat. The counter electrode was a platinum wire and reference electrode was an Ag/AgCl, KCl saturated. Before each experiment, working electrodes were mechanically polished with 600 and 1200 grade papers, rinsed with distilled water and dried in air. All experiments were carried out at 37.0oC in conventional three-compartment double wall glass cell containing mouthwashes. The microstructures of two alloys were observed in optical microscopy. Analysis of curves showed that Ni-Cr alloy was less reactive in the presence of 0.12% chlorohexidine digluconate while Ni-Cr-Ti alloy was more sensitive for others two types of mouthwashes (0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride® and 0.05% sodium fluoride + 0.03% triclosan). This occurred probably due presence of titanium in this alloy. Microstructural analysis reveals the presence of dendritic and eutectic microstructures for NiCr and Ni-Cr-Ti, respectively
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Titânio / Corrosão / Antissépticos Bucais Idioma: Inglês Revista: Rev. Odontol. Araçatuba (Impr.) Ano de publicação: 2011 Tipo de documento: Artigo
Texto completo: Disponível Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Titânio / Corrosão / Antissépticos Bucais Idioma: Inglês Revista: Rev. Odontol. Araçatuba (Impr.) Ano de publicação: 2011 Tipo de documento: Artigo
...