Your browser doesn't support javascript.
loading
Estudo in vivo e in vitro da corrosão de ligas de Co-Cr e de Ni-Cr utilizadas em estruturas protéticas de implantes orais / In vitro and in vivo studies of corrosion of Co-Cr and Ni-Cr alloys used in oral implant prosthetic superstructures
São Paulo; s.n; 2013. 166 p. ilus, tab, graf. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-866723
Biblioteca responsável: BR97.1
Localização: BR97.1; T4.846
RESUMO
Este trabalho avaliou o comportamento eletroquímico de três ligas de níquel-cromo e duas de cobalto-cromo in vitro e in vivo. Nos estudos in vitro foram fabricados eletrodos de trabalho a partir destas ligas. Estes eletrodos ficaram imersos em meio de NaCl 0,15 mol.L-1 a 36,5°C e foram submetidos às técnicas do potencial de circuito aberto, polarização potenciostática anódica e cronoamperometria. Para os estudos in vivo foram selecionados quinze pacientes com implantes já osseointegrados e aguardando a instalação das próteses. Esses pacientes foram distribuídos aleatoriamente em cinco grupos, correspondentes às cinco ligas diferentes. Deste modo, as estruturas protéticas dos implantes foram fundidas utilizando as cinco ligas. Foi utilizada a microscopia eletrônica de varredura (MEV) e a espectroscopia por dispersão de energia (EDS) como métodos de análise das superfícies linguais metálicas das próteses, antes da instalação em ambiente oral e após seis meses de permanência. Vistas por MEV, as ligas duas de cobalto-cromo Starloy C e Remanium 2001 e duas de níquel-cromo Wiron 99 e Remanium CSe apresentaram superfícies heterogêneas caracterizadas por uma fase semelhante à matriz da liga e a outra fase, composta por elementos de maior densidade atômica, correspondente à fase interdendrítica. Após seis meses, não houve sinais de corrosão e alterações significativas na composição destas ligas. As ligas de Co-Cr avaliadas, sob o ponto de vista eletroquímico, indicam comportamento catódico quando unidas ao implante sendo um fator indicativo de proteção à corrosão.
ABSTRACT
In this study, the electro-chemical behavior of three nickel-chrome and two cobalt chrome alloys was studied in vitro and in vivo. In the in vitro studies, working electrodes made of these alloys were fabricated. These electrodes were immersed in a medium of NaCl 0.15 mol.L-1 at 36.5°C and were submitted to the open circuit potential, anodic potentiostatic polarization and chronoamperometry techniques. For the in vivo studies, 15 patients whose implants had osseointegrated, and who were waiting for dental implant placement, were selected. These patients were randomly distributed into five groups, corresponding to the five different alloys. Thus the prosthetic implant superstructures were cast, using the five alloys. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used as methods to analyze the metal lingual surfaces of the prostheses, before they were placed in the oral environment, and after six months in place. Visualized by SEM, the two cobalt-chrome alloys Starloy C and Remanium 2001, and two types of nickel-chrome - Wiron 99 and Remanium Cse - presented heterogeneous surfaces characterized by a phase similar to that of the alloy matrix, and the other phase composed of elements of greater atomic density, corresponding to the interdendritic phase. After six months, there were no signs of corrosion and significant alterations in the composition of these alloys. The Co-Cr alloys evaluated, from an electrochemical point of view, indicated a cathodic behavior when united to the implant, this being a factor indicative of protection against corrosion
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Reabsorção Óssea / Implantes Dentários / Corrosão / Ligas Dentárias Tipo de estudo: Ensaio clínico controlado Limite: Feminino / Humanos / Masculino Idioma: Português Ano de publicação: 2013 Tipo de documento: Tese
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Reabsorção Óssea / Implantes Dentários / Corrosão / Ligas Dentárias Tipo de estudo: Ensaio clínico controlado Limite: Feminino / Humanos / Masculino Idioma: Português Ano de publicação: 2013 Tipo de documento: Tese
...