Your browser doesn't support javascript.
loading
Comparative analysis of plastic deformation of NiTi and CuNiTi wires submitted to mechanical cycling / Análise da deformação plástica em fios ortodônticos de NiTi e CuNiTi submetidos à ciclagem mecânica
GARCIA, Fernando Gonçalves; BARBOSA, Jurandir Antonio; BASTING, Roberta Tarkany.
Afiliação
  • GARCIA, Fernando Gonçalves; São Leopoldo Mandic. School of Dentistry and Research Institute. Campinas. BR
  • BARBOSA, Jurandir Antonio; São Leopoldo Mandic. School of Dentistry and Research Institute. Campinas. BR
  • BASTING, Roberta Tarkany; São Leopoldo Mandic. School of Dentistry and Research Institute. Campinas. BR
Braz. dent. sci ; 20(3): 78-86, 2017. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-868091
Biblioteca responsável: BR243.1
RESUMO
Objective: O objetivo deste trabalho foi avaliar a deformação plástica em fios NiTi e CuNiTi submetidos à ciclagem mecânica. Material e Métodos: Utilizaram-se fios ortodônticos de CuNITi de cinco marcas comerciais (n=10): RMO, Orthometric, Ormco, Aditek e Eurodonto; e um grupo controle de fio NiTi: Aditek termoativado. Todos os fios, com calibre 0.016'', foram encaixados em slots de quatro bráquetes convencionais alinhados e fixados a uma placa de acrílico. O teste foi realizado com aplicação de carga de 3 N e frequência de 2 Hz entre os dois bráquetes mais centrais, limitando-se à 10.000 ciclos. Após a ciclagem, observou-se a presença ou ausência de fratura dos fios. Não havendo fratura, os fios foram analisados quanto à deformação plástica com uso de transferidor, medindo-se a angulação do fio deformado. Resultados: Os resultados mostraram que não houve fratura de nenhum dos fios analisados. O teste de Kruskal-Wallis mostrou diferenças entre as angulações dos fios ortodônticos (p=0.0009). Com exceção dos fios da Ormco, os demais apresentaram deformação plástica. A maior mediana do valor de angulação foi observada para o fio Aditek Cuper NiTi. Observou-se que as menores medianas foram observadas para os fios RMO, Eurodonto e Ormco. Os fios Aditek termoativado e Orthometric apresentaram angulação intermediária. Conclusão: Nenhum dos fios analisados apresentou fratura. Houve diferenças quanto à deformação plástica sofrida pelos fios avaliados, independentemente da presença de cobre na sua composição química, sendo que o fio Ormco foi o único que não apresentou qualquer deformação. (AU)
ABSTRACT
Objetivo: The aim of this study was to evaluate the plastic deformation of NiTi and CuNiTi archwires submitted to mechanical cycling. Material and Methods: Orthodontic archwires made of CuNiTi of five commercial brands (n=10) were used: RMO, Orthometric, Ormco, Aditek and Eurodonto; and a Control Group of NiTi archwire: Aditek thermoactivated. All the archwires, with caliber 0.016", were fitted into the slots of four conventional brackets, aligned and fixed to an acrylic plate. The test was performed by applying a load of 3 N and frequency of 2 Hz between the most central brackets, limited to 10,000 cycles. After cycling, the presence or absence of archwire fracture was observed. When there was no fracture, the archwires were analyzed relative to plastic deformation with the use of a transferer, measuring the angulation of the deformed archwire. Results: The results showed that there was no fracture in any of the wires analyzed. The Kruskal-Wallis test showed differences among the angulations of the orthodontic archwires (p=0.0009). With exception of the Ormco wires, the other types presented plastic deformation. The highest median of the angulation value was observed for the Aditek Copper NiTi archwire. The lowest median values were observed for the RMO, Eurodonto and Ormco archwires. The Aditek thermoactivated and Orthometric archwires presented intermediate angulation. Conclusion: None of the archwires analyzed presented fracture. These archwires presented differences in plastic deformation, irrespective of the presence of copper in their chemical composition. The Ormco archwire was the only type that presented no deformation whatever (AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Fios Ortodônticos / Cobre / Fraturas Ósseas Idioma: Inglês Revista: Braz. dent. sci Assunto da revista: Odontologia / Sa£de Bucal Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Leopoldo Mandic/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Fios Ortodônticos / Cobre / Fraturas Ósseas Idioma: Inglês Revista: Braz. dent. sci Assunto da revista: Odontologia / Sa£de Bucal Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Leopoldo Mandic/BR
...