Eficácia da escova dental convencional e de cabeça tripla na remoção do biofilme dental em crianças / The cleaning efficiency of a conventional and a triple-headed toothbrush in children
RGO (Porto Alegre)
; 59(2): 259-263, abr.-jun. 2011. ilus, tab
Artigo
em Português
| LILACS, BBO - Odontologia
| ID: biblio-874578
Biblioteca responsável:
BR1354.1
Localização: BR1354.1
RESUMO
Objetivo:
Comparar a eficácia de duas escovas na remoção de biofilme dental utilizadas por crianças de quatro anos de idade.Métodos:
As escovas dentais convencional (Bitufo® 22, Bitufo, Itupeva, Brasil) e de cabeça tripla (DenTrust®, Dental HealthWay Inc., Newport, EUA) foram utilizadas por 20 crianças previamente treinadas para realizarem a escovação pelo tempo de um minuto em cada arco. A eficácia de cada escova foi avaliada pela quantidade de biofilme dental presente nas superfícies dentárias antes e após a escovação, evidenciada com o uso do corante fluorescente (Plaque Test® Vivadent, Ivoclar Vivadent AG, Schaan, Principado de Liechtenstein) e categorizada pela utilização dos índices de Rodrigues et al.1 para superfícies lisas e de Greene & Vermillion2 para superfícies oclusais. Os dados foram submetidos à Análise de Variância, Teste de Tukey e Kruskal-Wallis (?=0,05).Resultados:
Independente da escova utilizada houve redução dos escores na quantidade de biofilme presente nas superfícies dentárias (p=0,000). Considerando somente as superfícies oclusais, não foram encontradas diferenças estatísticas significativas entre as escovas. Entretanto, a escova tripla apresentou melhor desempenho na remoção de biofilme nas superfícies lisas (p<0,05) principalmente nas faces linguais/palatinas (p<0,0001). Na região anterior do arco não houve diferença entre as escovas e na região posterior a escova tripla também proporcionou maior redução de biofilme em comparação à escova convencional (p<0,0001).Conclusão:
Com base nos resultados, concluiu-se que as duas escovas avaliadas foram efetivas na remoção de biofilme dental, contudo que a escova de cabeça tripla apresentou desempenho superior.ABSTRACT
Objective:
The objective of this study was to compare the efficacy of bacterial plaque removal with conventional (Bitufo® 22, Bitufo, Itupeva, Brazil) and triple-headed (DenTrust®, Dental HealthWay Inc., Newport, USA) toothbrushes.Methods:
Twenty children aged 4 years old participated in this crossed study, with weekly intervals. The quantity of biofilm was evaluated before and after toothbrushing by children for 1 minute each arch. A fluorescent light-cured bacterial plaque revealer (Plaque Test® Vivadent, Ivoclar Vivadent AG, Schaan, Principality of Liechtenstein) was used to report Greene and Vermillion1 index for free smooth surfaces, and Rodrigues et al.2 index for occlusal surfaces. Data were submitted to ANOVA.Results:
In spide of the employed toothbrush, there was statistically significant difference on plaque removal between smooth or occlusal surfaces (p=0.000). The triple-headed and the conventional type cleaned occlusal surfaces similarly. However, the triple-headed toothbrush removed more plaque on buccal surface than the conventional type (p<0.05). The triple-headed toothbrush removed more plaque on the buccal surface (p<0.0001). The conventional and the triple-headed promoted a similar plaque removal both in anterior buccal areas. The triple-headed toothbrush was more effective than the conventional type on the posterior area (p<0.0001).Conclusion:
It was concluded that effective plaque removal was achieved by the children with both toothbrushes; however the triple-headed toothbrush had a better performance.
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
BBO - Odontologia
/
LILACS
Assunto principal:
Escovação Dentária
/
Odontopediatria
/
Placa Dentária
Idioma:
Português
Revista:
RGO (Porto Alegre)
Assunto da revista:
Odontologia
Ano de publicação:
2011
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Faculdade São Leopoldo Mandic/BR
/
Universidade Federal de Santa Maria/BR
/
Universidade de São Paulo/BR