Falha do teste desfibrilatório associado a posicionamento do cabo-eletrodo de choque no septo do ventrículo direito / Defibrillation test failure associated with right ventricular septum positioning of the shock electrode
Souza, Charles Rios; Mateos, José Carlos Pachón; Mateos, Juan Carlos Pachón; Vargas, Remy Nelson Albornoz.
Afiliação
  • Souza, Charles Rios; Universidade Federal de Minas Gerais. Estimulação Cardíaca Artificial. Belo Horizonte - MG. BR
  • Mateos, José Carlos Pachón; Instituto Dante Pazzanese de Cardiologia (IDPC). Serviço Médico de Estimulação Cardíaca Artificial. São Paulo - SP. BR
  • Mateos, Juan Carlos Pachón; Instituto Dante Pazzanese de Cardiologia (IDPC). Serviço Médico de Estimulação Cardíaca Artificial. São Paulo - SP. BR
  • Vargas, Remy Nelson Albornoz; Instituto Dante Pazzanese de Cardiologia (IDPC). Serviço Médico de Estimulação Cardíaca Artificial. São Paulo - SP. BR
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(3): f:114-l:116, jul.-set. 2017. ilus
Artigo em Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-877290
Biblioteca responsável: BR44.1
Localização: BR44.1 / BR79.1
RESUMO
O teste de desfibrilação, durante muitos anos, foi prática comum no momento do implante de cardiodesfibrilador. Após o estudo Shockless Implant Evaluation (SIMPLE), que não evidenciou redução da eficácia e da segurança do cardiodesfibrilador a longo prazo com a não realização do teste de desfibrilação, esse teste deixou de ser realizado na população incluída no estudo. Os autores relatam o caso de falha no teste desfibrilatório em implante de cardiodesfibrilador com cabo-eletrodo de choque implantado em septo médio. Apresentam, também, uma análise post hoc usando os pacientes do estudo SIMPLE, comparando o sucesso da desfibrilação aguda e a longo prazo entre implantes de cardiodesfibrilador com posicionamentos apical e não apical do cabo-eletrodo de choque
ABSTRACT
For many years, the defibrillation test was a common practice at the time of cardioverter defibrillator implant. After the SIMPLE (Shockless Implant Evaluation) study demonstrated there was no long-term reduction in the efficacy and safety of the cardioverter defibrillator in the absence of a defibrillation test, this test was no longer performed for the study population. The authors report a case of defibrillation test failure in a cardioverter defibrillator implant with the shock electrode implanted in the medial septum. They also report a post-hoc analysis using patients who participated in the SIMPLE study, comparing the acute and a long-term defibrillation success rates in cardioverter defibrillator implants with apical and non-apical positioning of the shock electrode
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Brasil Base de dados: LILACS / Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Choque / Desfibriladores Implantáveis / Septos Cardíacos / Ventrículos do Coração Tipo de estudo: Estudo diagnóstico / Estudo de etiologia / Fatores de risco Limite: Humanos / Masculino Idioma: Português Revista: RELAMPA, Rev. Lat.-Am. Marcapasso Arritm Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Dante Pazzanese de Cardiologia (IDPC)/BR / Universidade Federal de Minas Gerais/BR

Texto completo: Disponível Coleções: Bases de dados nacionais / Brasil Base de dados: LILACS / Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Choque / Desfibriladores Implantáveis / Septos Cardíacos / Ventrículos do Coração Tipo de estudo: Estudo diagnóstico / Estudo de etiologia / Fatores de risco Limite: Humanos / Masculino Idioma: Português Revista: RELAMPA, Rev. Lat.-Am. Marcapasso Arritm Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Dante Pazzanese de Cardiologia (IDPC)/BR / Universidade Federal de Minas Gerais/BR
...