Your browser doesn't support javascript.
loading
Alteração de Cor de Resinas Compostas Imersas em Diferentes Bebidas / Colors Change of Composite Resins Immersed in Different Beverages
Carvalho, Anita Cruz; Alves, Carolina Costa; Silva, Carolline Oliveira Gutierres; Palma-Dibb, Regina Guenka; Martins, Vinicius Rangel Geraldo; Lepri, Cesar Penazzo.
Afiliação
  • Carvalho, Anita Cruz; Universidade Federal de Minas Gerais, Faculdade de Odontologia. MG. Brasil. Universidade de Uberaba, Programa de Pós-Graduação Stricto Sensu em Odontologia. Minas Gerais. BR
  • Alves, Carolina Costa; Universidade de Uberaba, Programa de Pós-Graduação Stricto Sensu em Odontologia. Uberaba. BR
  • Silva, Carolline Oliveira Gutierres; Universidade de Uberaba, Programa de Pós-Graduação Stricto Sensu em Odontologia. Uberaba. BR
  • Palma-Dibb, Regina Guenka; Universidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto. SP, Brasil. Ribeirão Preto. BR
  • Martins, Vinicius Rangel Geraldo; Universidade de Uberaba, Programa de Pós-Graduação Stricto Sensu em Odontologia. Uberaba. BR
  • Lepri, Cesar Penazzo; Universidade de Uberaba, Programa de Pós-Graduação Stricto Sensu em Odontologia. Uberaba. BR
J. health sci. (Londrina) ; 19(4)30/10/2017.
Artigo em Português | LILACS | ID: biblio-877741
Biblioteca responsável: BR1896.9
RESUMO
O presente estudo analisou resinas compostas imersas em diferentes bebidas (café, vinho tinto, refrigerante a base de cola e água destilada) nos diferentes tempos de polimento. Avaliou-se também a estabilidade de cor após o repolimento. As resinas compostas utilizadas foram Resina Filtek Z350 XT e Resina Brilliant NG; as bebidas para o experimento foram café, refrigerante à base de cola, vinho tinto e água destilada, que corresponde ao grupo controle. Foram confeccionados 160 corpos de prova 80 de cada resina composta. Vinte corpos de prova receberam polimento imediato, vinte receberam polimento após 24 horas, vinte o polimento após 7 dias e os outros vinte não receberam polimento. As análises de cor foram feitas utilizando o aparelho espectrocolorímetro, que utiliza o sistema CIELab. Foi avaliado o ΔE dos grupos após 30 dias (ΔE= 30d ­ baseline). Os dados foram submetidos à ANOVA e teste de Tukey (α=5%). Os corpos-de-prova passaram por processo de repolimento com discos de Sof-Lex Pop On e, posteriormente, foram analisados em busca de identificar se houve aproximação equivalente à cor inicial. As bebidas testadas possuem capacidade de manchamento, sendo o café e o vinho tinto os grupos com maiores valores de alteração de cor, seguido do refrigerante à base de cola. As resinas compostas polidas apresentaram valores menores de alteração de cor, independentemente, do tempo de polimento. Com o repolimento, a água destilada e o refrigerante à base de cola tiveram seus valores considerados clinicamente aceitáveis ΔE<3,3. Já o café e o vinho tinto tiveram seus valores de manchamento reduzidos, porém perceptíveis ao olho humano. (AU)
ABSTRACT
The present study examined composite resins in different beverages (coffee, red wine, cola-based soda and distilled water) in the different times of polishing and after the re-polishing. The composite resins used were resin Filtek Z350 XT and resin Brilliant NG; the tested beverages were coffee, red wine, soft-drink and distilled water corresponding to the control group. 160 specimens were made, 80 of each composite. Twenty specimens were given immediate polishing, twenty were polished after 24 hours, twenty were polished after 7 days and the other twenty had no polishing. Color analysis was made using the spectrophotometer device that uses CIELab system. ΔE was evaluated after 30 days immersion period (ΔE = 30-days - baseline). The data were submitted to ANOVA and Tukey tests (α=5%). Then, specimens were re-polished with Sof- Lex Pop On and subsequently analyzed if there was approach equivalent to the initial color. All the tested beverages had ability to staining, and coffee and red wine groups showed higher values of color change, followed by soft-drink. The composite resins polished showed lower values of color change, regardless of the polishing time. After re-polishing, distilled water and soft-drink had their values considered clinically acceptable ΔE<3.3; coffee and red wine had their staining values reduced, but perceptible to the human eye. (AU)


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Português Revista: J. health sci. (Londrina) Assunto da revista: Medicina / Sa£de P£blica Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais, Faculdade de Odontologia. MG. Brasil/BR / Universidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto. SP, Brasil/BR / Universidade de Uberaba, Programa de Pós-Graduação Stricto Sensu em Odontologia/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Português Revista: J. health sci. (Londrina) Assunto da revista: Medicina / Sa£de P£blica Ano de publicação: 2017 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais, Faculdade de Odontologia. MG. Brasil/BR / Universidade de São Paulo, Faculdade de Odontologia de Ribeirão Preto. SP, Brasil/BR / Universidade de Uberaba, Programa de Pós-Graduação Stricto Sensu em Odontologia/BR
...