Your browser doesn't support javascript.
loading
Avaliação do grau de conversão monomérica de resinas compostas ortodônticas / Degree of conversion evaluation of an orthodontics composite resins
Coelho, Ulisses; Cruz, Fernanda Zander Grande da; Grande, Christiana Zander; Hilgemberg, Sergio Paulo; Montenegro, Andres Fernando.
Afiliação
  • Coelho, Ulisses; UEPG. BR
  • Cruz, Fernanda Zander Grande da; UEPG. BR
  • Grande, Christiana Zander; UEPG. BR
  • Hilgemberg, Sergio Paulo; UEPG. BR
  • Montenegro, Andres Fernando; UEPG. BR
Ortho Sci., Orthod. sci. pract ; 11(41): 28-32, 2018. ilus, tab, graf
Artigo em Português | BBO - Odontologia | ID: biblio-882315
Biblioteca responsável: BR243.1
RESUMO
Este estudo avaliou o grau de conversão de uma resina composta utilizada em tratamentos restauradores, Filtek Z 250 - 3M ESPE (Z250), e duas resinas ortodônticas Orthocem - FGM (OC) e Transbond XT - 3M Unitek (TB) por meio da espectroscopia no infravermelho por transformada de Fourier (FTIR). Para isto, foram confeccionados quinze corpos de prova fotopolimerizados para cada resina. As medidas de grau de conversão foram realizadas imediatamente após a confecção das amostras. Os espectros de absorção no infravermelho foram obtidos num espectrofotômetro Parkin Elmer do Brasil. Os resultados das amostras tiveram sua normalidade aferida por meio do teste Kolmogorov-Smirnov e analisadas pelo teste ANOVA um critério, que demonstrou haver diferença estatística entre os grupos (p<0,05). (AU)
ABSTRACT
This study evaluated the degree of conversion of a composite resin used in restorative treatments, Filtek Z 250 - 3M ESPE (Z250), and two orthodontic resins Orthocem - FGM (OC) and Transbond XT - 3M Unitek (TB) by means of infrared spectroscopy Fourier transform (FTIR). For this, fifteen bodies of light cured specimens were fabricated for each resin. Measures of degree of conversion were performed immediately after preparation of the samples. The infrared absorption spectra were obtained on a Parkin Elmer spectrophotometer Brazil. The results of the samples were measured using normality of the Kolmogorov-Smirnov test and analyzed by ANOVA criterion, which showed no statistical difference between groups (p<0,05). (AU)
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Ortodontia / Resinas Compostas / Cimentos Dentários / Cura Luminosa de Adesivos Dentários Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: UEPG/BR
Buscar no Google
Coleções: Bases de dados nacionais Base de dados: BBO - Odontologia Assunto principal: Ortodontia / Resinas Compostas / Cimentos Dentários / Cura Luminosa de Adesivos Dentários Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: UEPG/BR
...