Concentração de íons flúor em águas minerais envasadas no Rio Grande do Sul / Concentration of fluoride ions in mineral water bottled in the state of Rio Grande do Sul
RFO UPF
; 23(2): 156-160, 24/10/2018. tab
Artigo
em Português
| LILACS, BBO - Odontologia
| ID: biblio-947639
Biblioteca responsável:
BR1.1
RESUMO
Objetivo:
avaliar o nível de flúor presente nas águas minerais carbogasosas e não carbogasosas envasadas no estado do Rio Grande do Sul, comparando os dados com as informações descritas nos rótulos das embalagens. Materiais emétodo:
foram analisadas cinco marcas comerciais de água mineral. Os valores de padrão/ amostra e tampão Tisab foram utilizados em uma relação de 11, e as amostras foram lidas em duplicata. As amostras carbogasosas foram agitadas com bastão magnético para eliminação do gás carbônico. Para determinação de flúor, foram utilizados analisador específico de íons, eletrodo seletivo para íon flúor, eletrodo de referência Ag/AgCl de junção simples.Resultados:
foram encontradas concentrações de flúor variando entre 0,13 mg F-/L e 1,31 mg F-/L, com diferenças entre os valores estipulados nos rótulos das marcas de água mineral avaliadas e as análises laboratoriais na presente investigação. Os valores de duas marcas de água mineral com flúor analisadas no estudo mostraram-se acima, considerando os valores de referência (0,6-0,8 mg F-/L), e uma marca não apresentou valores de ação preventiva contra a cárie dentária (valores abaixo de 0,6 mg F-/ L).Conclusão:
conclui-se que há divergência entre os valores de íons flúor encontrados nas medições e os informados nos rótulos, sendo necessário um sistema de melhor vigilância para o controle dos níveis de flúor nas águas minerais disponibilizadas à população do estado do Rio Grande do Sul, considerando os benefícios do consumo de águas minerais para prevenção dos níveis de cárie na população. (AU)ABSTRACT
Objective:
quantify the fluoride level in carbogaseous and non-carbogaseous mineral waters bottled in the state of Rio Grande do Sul, Brazil, as well as to compare the data with the information described on the package labels. Materials andmethod:
five brands of mineral water were analyzed. Standard/sample values and Tisab buffer were used in a ratio of 11, and the samples were read in duplicates. The carbogaseous samples were shaken with a magnetic rod to eliminate the carbon dioxide. For fluoride determination, a specific ion analyzer was used, as well as a fluoride ion-selective electrode, single-junction Ag/AgCl reference electrode.Results:
fluoride concentrations ranging from 0.13 mg F-/L to 1.31 mg F-/L were found, with differences between the values specified in the labels of the mineral water brands evaluated and the laboratory analyses of the present investigation. The values of two brands of mineral water with fluoride analyzed in the study were high, considering the reference values (0.6-0.8 mg F-/L), and one brand did not present values of preventive action against dental caries (below 0.6 mg F-/L).Conclusion:
there is a divergence between the values of fluoride ions measured and those reported on the labels, which requires a better surveillance system for controlling fluoride levels in the mineral waters offered to the population of the state of Rio Grande do Sul, Brazil, considering the benefits of mineral water consumption to prevent caries levels in the population. (AU)
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
BBO - Odontologia
/
LILACS
Assunto principal:
Flúor
/
Íons
/
Águas Minerais
País/Região como assunto:
América do Sul
/
Brasil
Idioma:
Português
Revista:
RFO UPF
Assunto da revista:
Odontologia
Ano de publicação:
2018
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Fundação de Ciência e Tecnologia do RS/BR
/
Universidade Federal de Pelotas/BR
/
Universidade Luterana do Brasil/BR